293 resultados para Comparison of nucleotide sequences


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The aim of this study was to evaluate and compare organ doses delivered to patients in wrist and petrous bone examinations using a multislice spiral computed tomography (CT) and a C-arm cone-beam CT equipped with a flat-panel detector (XperCT). For this purpose, doses to the target organ, i.e. wrist or petrous bone, together with those to the most radiosensitive nearby organs, i.e. thyroid and eye lens, were measured and compared. Furthermore, image quality was compared for both imaging systems and different acquisition modes using a Catphan phantom. Results show that both systems guarantee adequate accuracy for diagnostic purposes for wrist and petrous bone examinations. Compared with the CT scanner, the XperCT system slightly reduces the dose to target organs and shortens the overall duration of the wrist examination. In addition, using the XperCT enables a reduction of the dose to the eye lens during head scans (skull base and ear examinations).

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Efficacy and tumour selectivity of photodynamic therapy with two clinically approved sensitizers (mTHPC, verteporfin) were assessed for focal intracavitary photodynamic therapy (PDT) in rodents with malignant pleural mesothelioma (MPM) at recommended drug-light conditions and at escalating sensitizer dosages. MPM tumours were generated in 15 Fischer rats by subpleural mediastinal tumour cell injection followed after 5 days by intracavitary PDT with light delivery monitored by in situ dosimetry. Animals were intravenously sensitized either with mTHPC (0.1 mg/kg, n = 3; 0.2 mg/kg, n = 3) followed after 4 days by illumination with 20 J/cm(2) at 652 nm, or with verteporfin (0.6 mg/kg, n = 3; 1.2 mg/kg, n = 3) followed after 20 min by illumination with 100 J/cm(2) at 689 nm. Three untreated tumour-bearing animals served as controls. Histological evaluation of the treated tumour and of adjacent normal organs was performed 10 days after tumour implantation. The extent of PDT-induced tumour necrosis was compared to the non-necrosed area and expressed in percentage. A locally invasive growing MPM tumour (3.1 +/- 1 mm diameter) without spontaneous necrosis diameter was found in all animals. For both sensitizers, focal intracavitary PDT was well tolerated at drug-light conditions recommended for clinical applications. Mediastinal organs were spared for both sensitizers but verteporfin resulted in a higher extent of tumour necrosis (80%) than mTHPC (50%). Drug dose escalation revealed a higher extent of PDT-related tumour necrosis for both sensitizers (mTHPC 55%, verteporfin 88%), however, verteporfin-PDT was associated with a higher toxicity than mTHPC-PDT.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

PURPOSE: Few studies compare the variabilities that characterize environmental (EM) and biological monitoring (BM) data. Indeed, comparing their respective variabilities can help to identify the best strategy for evaluating occupational exposure. The objective of this study is to quantify the biological variability associated with 18 bio-indicators currently used in work environments. METHOD: Intra-individual (BV(intra)), inter-individual (BV(inter)), and total biological variability (BV(total)) were quantified using validated physiologically based toxicokinetic (PBTK) models coupled with Monte Carlo simulations. Two environmental exposure profiles with different levels of variability were considered (GSD of 1.5 and 2.0). RESULTS: PBTK models coupled with Monte Carlo simulations were successfully used to predict the biological variability of biological exposure indicators. The predicted values follow a lognormal distribution, characterized by GSD ranging from 1.1 to 2.3. Our results show that there is a link between biological variability and the half-life of bio-indicators, since BV(intra) and BV(total) both decrease as the biological indicator half-lives increase. BV(intra) is always lower than the variability in the air concentrations. On an individual basis, this means that the variability associated with the measurement of biological indicators is always lower than the variability characterizing airborne levels of contaminants. For a group of workers, BM is less variable than EM for bio-indicators with half-lives longer than 10-15 h. CONCLUSION: The variability data obtained in the present study can be useful in the development of BM strategies for exposure assessment and can be used to calculate the number of samples required for guiding industrial hygienists or medical doctors in decision-making.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We prospectively compared the diagnostic value of C-reactive protein (CRP) and white blood cell counts for detection of neonatal septicaemia. Sensitivity and specifity in receiver operating characteristics, and positive and negative predictive value of CRP and white blood cell count were compared in 195 critically ill preterm and term newborns clinically suspected of infection. Blood cultures were positive in 33 cases. During the first 3 days after birth CRP elevation (sensitivity 75%, specifity 86%), leukopenia (67%/90%), neutropenia (78%/80%) and immature to total neutrophil count (I/T) ratio (78%/73%) were good diagnostic parameters, as opposed to band forms with absolute count (84%/66%) or percentage (79%/71%), thrombocytopenia (65%/57%) and toxic granulations (44%/94%). Beyond 3 days of age elevated CRP (88%/87%) was the best parameter. Increased total (84%/66%) or percentage band count (79%/71%) were also useful. Leukocytosis (74%/56%), increased neutrophils (67%/65%), I/T ratio (79%/47%), thrombocytopenia (65%/57%) and toxic granulations had a low specifity. The positive predictive value of CRP was 32% before and 37% after 3 days of age, that of leukopenia was 37% in the first 3 days. CONCLUSION: During the first 3 days of life CRP, leukopenia and neutropenia were comparably good tests while after 3 days of life CRP was the best single test in early detection of neonatal septicaemia. Serial CRP estimations confirm the diagnosis, monitor the course of infection and the efficacy of antibiotic treatment.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The most widely used formula for estimating glomerular filtration rate (eGFR) in children is the Schwartz formula. It was revised in 2009 using iohexol clearances with measured GFR (mGFR) ranging between 15 and 75 ml/min × 1.73 m(2). Here we assessed the accuracy of the Schwartz formula using the inulin clearance (iGFR) method to evaluate its accuracy for children with less renal impairment comparing 551 iGFRs of 392 children with their Schwartz eGFRs. Serum creatinine was measured using the compensated Jaffe method. In order to find the best relationship between iGFR and eGFR, a linear quadratic regression model was fitted and a more accurate formula was derived. This quadratic formula was: 0.68 × (Height (cm)/serum creatinine (mg/dl))-0.0008 × (height (cm)/serum creatinine (mg/dl))(2)+0.48 × age (years)-(21.53 in males or 25.68 in females). This formula was validated using a split-half cross-validation technique and also externally validated with a new cohort of 127 children. Results show that the Schwartz formula is accurate until a height (Ht)/serum creatinine value of 251, corresponding to an iGFR of 103 ml/min × 1.73 m(2), but significantly unreliable for higher values. For an accuracy of 20 percent, the quadratic formula was significantly better than the Schwartz formula for all patients and for patients with a Ht/serum creatinine of 251 or greater. Thus, the new quadratic formula could replace the revised Schwartz formula, which is accurate for children with moderate renal failure but not for those with less renal impairment or hyperfiltration.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Combined positron emission tomography and computed tomography (PET/CT) scanners play a major role in medicine for in vivo imaging in an increasing number of diseases in oncology, cardiology, neurology, and psychiatry. With the advent of short-lived radioisotopes other than 18F and newer scanners, there is a need to optimize radioisotope activity and acquisition protocols, as well as to compare scanner performances on an objective basis. The Discovery-LS (D-LS) was among the first clinical PET/CT scanners to be developed and has been extensively characterized with older National Electrical Manufacturer Association (NEMA) NU 2-1994 standards. At the time of publication of the latest version of the standards (NU 2-2001) that have been adapted for whole-body imaging under clinical conditions, more recent models from the same manufacturer, i.e., Discovery-ST (D-ST) and Discovery-STE (D-STE), were commercially available. We report on the full characterization both in the two- and three-dimensional acquisition mode of the D-LS according to latest NEMA NU 2-2001 standards (spatial resolution, sensitivity, count rate performance, accuracy of count losses, and random coincidence correction and image quality), as well as a detailed comparison with the newer D-ST widely used and whose characteristics are already published.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Protein-energy malnutrition is highly prevalent in aged populations. Associated clinical, economic, and social burden is important. A valid screening method that would be robust and precise, but also easy, simple, and rapid to apply, is essential for adequate therapeutic management. OBJECTIVES: To compare the interobserver variability of 2 methods measuring food intake: semiquantitative visual estimations made by nurses versus calorie measurements performed by dieticians on the basis of standardized color digital photographs of servings before and after consumption. DESIGN: Observational monocentric pilot study. SETTING/PARTICIPANTS: A geriatric ward. The meals were randomly chosen from the meal tray. The choice was anonymous with respect to the patients who consumed them. MEASUREMENTS: The test method consisted of the estimation of calorie consumption by dieticians on the basis of standardized color digital photographs of servings before and after consumption. The reference method was based on direct visual estimations of the meals by nurses. Food intake was expressed in the form of a percentage of the serving consumed and calorie intake was then calculated by a dietician based on these percentages. The methods were applied with no previous training of the observers. Analysis of variance was performed to compare their interobserver variability. RESULTS: Of 15 meals consumed and initially examined, 6 were assessed with each method. Servings not consumed at all (0% consumption) or entirely consumed by the patient (100% consumption) were not included in the analysis so as to avoid systematic error. The digital photography method showed higher interobserver variability in calorie intake estimations. The difference between the compared methods was statistically significant (P < .03). CONCLUSIONS: Calorie intake measures for geriatric patients are more concordant when estimated in a semiquantitative way. Digital photography for food intake estimation without previous specific training of dieticians should not be considered as a reference method in geriatric settings, as it shows no advantages in terms of interobserver variability.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: Finding genes that are differentially expressed between conditions is an integral part of understanding the molecular basis of phenotypic variation. In the past decades, DNA microarrays have been used extensively to quantify the abundance of mRNA corresponding to different genes, and more recently high-throughput sequencing of cDNA (RNA-seq) has emerged as a powerful competitor. As the cost of sequencing decreases, it is conceivable that the use of RNA-seq for differential expression analysis will increase rapidly. To exploit the possibilities and address the challenges posed by this relatively new type of data, a number of software packages have been developed especially for differential expression analysis of RNA-seq data. RESULTS: We conducted an extensive comparison of eleven methods for differential expression analysis of RNA-seq data. All methods are freely available within the R framework and take as input a matrix of counts, i.e. the number of reads mapping to each genomic feature of interest in each of a number of samples. We evaluate the methods based on both simulated data and real RNA-seq data. CONCLUSIONS: Very small sample sizes, which are still common in RNA-seq experiments, impose problems for all evaluated methods and any results obtained under such conditions should be interpreted with caution. For larger sample sizes, the methods combining a variance-stabilizing transformation with the 'limma' method for differential expression analysis perform well under many different conditions, as does the nonparametric SAMseq method.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Background: The type of anesthesia to be used for total hip arthroplasty (THA) is still a matter of debate. We compared the occurrence of per- and post-anesthesia incidents in patients receiving either general (GA) or regional anesthesia (RA). Methods: We used data from 29 hospitals, routinely collected in the Anaesthesia Databank Switzerland register between January 2001 and December 2003. We used multi-level logistic regression models. Results: There were more per- and post-anesthesia incidents under GA compared to RA (35.1% vs 32.7 %, n = 3191, and 23.1% vs 19.4%, n = 3258, respectively). In multi-level logistic regression analysis, RA was significantly associated with a lower incidence of per-anesthetic problems, especially hypertension, compared with GA. During the post-anesthetic period, RA was also less associated with pain. Conversely, RA was more associated with post-anesthetic hypotension, especially for epidural technique. In addition, age and ASA were more associated with incidents under GA compared to RA. Men were more associated with per-anesthetic problems under RA compared to GA. Whereas increased age (>67), gender (male), and ASA were linked with the choice of RA, we noticed that this choice depended also on hospital practices after we adjusted for the other variables. Conclusions: Compared to RA, GA was associated with an increased proportion of per- and post-anesthesia incidents. Although this study is only observational, it is rooted in daily practice. Whereas RA might be routinely proposed, GA might be indicated because of contraindications to RA, patients' preferences or other surgical or anaesthesiology related reasons. Finally, the choice of a type of anesthesia seems to depend on local practices that may differ between hospitals.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A statistical methodology for the objective comparison of LDI-MS mass spectra of blue gel pen inks was evaluated. Thirty-three blue gel pen inks previously studied by RAMAN were analyzed directly on the paper using both positive and negative mode. The obtained mass spectra were first compared using relative areas of selected peaks using the Pearson correlation coefficient and the Euclidean distance. Intra-variability among results from one ink and inter-variability between results from different inks were compared in order to choose a differentiation threshold minimizing the rate of false negative (i.e. avoiding false differentiation of the inks). This yielded a discriminating power of up to 77% for analysis made in the negative mode. The whole mass spectra were then compared using the same methodology, allowing for a better DP in the negative mode of 92% using the Pearson correlation on standardized data. The positive mode results generally yielded a lower differential power (DP) than the negative mode due to a higher intra-variability compared to the inter-variability in the mass spectra of the ink samples.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

On 1 January 2012 Swiss Diagnosis Related Groups (DRG), a new uniform payment system for in-patients was introduced in Switzerland with the intention to replace a "cost-based" with a "case-based" reimbursement system to increase efficiency. With the introduction of the new payment system we aim to answer questions raised regarding length of stay as well as patients' outcome and satisfaction. This is a prospective, two-centre observational cohort study with data from University Hospital Basel and the Cantonal Hospital Aarau, Switzerland, from January to June 2011 and 2012, respectively. Consecutive in-patients with the main diagnosis of either community-acquired pneumonia, exacerbation of COPD, acute heart failure or hip fracture were included. A questionnaire survey was sent out after discharge investigating changes before and after SwissDRG implementation. Our primary endpoint was LOS. Of 1,983 eligible patients 841 returned the questionnaire and were included into the analysis (429 in 2011, 412 in 2012). The median age was 76.7 years (50.8% male). Patients in the two years were well balanced in regard to main diagnoses and co-morbidities. Mean LOS in the overall patient population was 10.0 days and comparable between the 2011 cohort and the 2012 cohort (9.7 vs 10.3; p = 0.43). Overall satisfaction with care changed only slightly after introduction of SwissDRG and remained high (89.0% vs 87.8%; p = 0.429). Investigating the influence of the implementation of SwissDRG in 2012 regarding LOS patients' outcome and satisfaction, we found no significant changes. However, we observed some noteworthy trends, which should be monitored closely.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To investigate the differences between Fundus Camera (Topcon TRC-50X) and Confocal Scanning Laser Ophthalmoscope (Heidelberg retina angiogram (HRA)) on the fundus autofluorescence (FAF) imaging (resolution and FAF characteristics). Methods: 105 eyes of 56 patients with various retinal diseases underwent FAF imaging with HRA (488nm exciter/500nm barrier filter) before fluorescein angiography (FFA) and Topcon Fundus Camera (580nm exciter/695nm barrier filter) before and after FFA. The quality of the FAF images was compared for their resolution and analysed for the influence of fixation stability and cataracts. Hypo-and hyper-FAF behaviour was analysed for the healthy disc, healthy fovea, and a variety of pathological features. Results: HRA images were found to be of superior resolution in 18, while Topcon images were estimated superior in 29 eyes. No difference was found in 58 eyes. Both poor fixation (p=0.009) and more advanced cataract (p=0.013) were found associated with better image quality by Topcon. Images acquired by Topcon before and after FFA were identical (100%). The healthy disc was usually dark on HRA (72%), but showed mild autofluorescence on Topcon (85%). The healthy fovea showed in 100% Hypo-FAF on HRA, while Topcon showed in 53% Iso-FAF, in 43% mild Hypo-FAF, and in 4% Hypo-FAF as on HRA. No difference of FAF was found for geographic atrophy, pigment changes, and drusen, although Topcon images were often more detailed. Hyper-FAF due to serous exudation showed better on HRA. Cystic edema was visible only on HRA in a petaloid hyper-FAF pattern in 83%, while only two eyes (17%) showed similar behavior in both HRA- and Topcon images. Hard exudates caused Hypo-FAF only on HRA, hardly visible on Topcon. Blockage phenomenon by blood however was identical. Conclusions: The filter set of Topcon and the single image acquisition appear to be an advantage for patients with cataract and poor fixation respectively. Preceding FFA does not alter the Topcon FAF image. Regarding the FAF behavior, there are differences between the 2 systems which need to be taken into account when interpreting the images.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

OBJECTIVES Little is known about the stent deformability required for optimal stented heart valve bioprosthesis design. Therefore, two bioprosthetic valves with known good long-term clinical results were tested. The strain in the radial direction of the stent posts of these valves was compared with contemporary bioprosthetic valves and a native porcine aortic root. METHODS Medtronic Intact and Carpentier-Edwards Standard (CES), and four contemporary bioprostheses, including one self-expanding prosthesis, were tested with three sonomicrometry probes per valve fixed at commissure attachment points. The mean values from 2400 data points from three measurements of the interprobe distances were used to calculate the radius of the circle circumscribed around the three probes. Changes in the radius of the aortic root at pressures 70-90 and 120-140 mmHg (pressure during diastole and systole) and that of the stent posts at 70-90 and 0-10 mmHg (transvalvular pressure gradient during diastole and systole) were compared. RESULTS An increase in radius by 7.3 ± 2.6, 8.7 ± 0.0 and 3.9 ± 0.0% for the porcine aortic root, CES and Intact valves, respectively, was observed during transition from diastolic to systolic pressure and less for contemporary bioprostheses-mean 2.5 ± 0.9%, lowest 1.2 ± 0.0. CONCLUSIONS The results indicate that the radial deformability of bioprosthetic valve stent posts can be as low as 1.2% for xenoaortic and 3.0% for xenopericardial prostheses with no compromise of valve durability. Although these results suggest that valve stent post-deformability might not be of critical importance, a concrete answer to the question of the significance of stent deformability for valve durability can be obtained only by acquiring long-term follow-up results for valve prostheses with rigid stents.