342 resultados para CT scan


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A 75-year-old man, with no significant symptoms, was referred after the incidental finding of a left hilar pulmonary mass of 30 × 30 × 50 mm on a chest CT. F-18 fluorodeoxyglucose (FDG) PET/CT demonstrated a heterogeneous, moderate radiotracer uptake in the mass (SUV 3.5 g/mL). Bronchoscopy revealed a discrete extrinsic compression of the superior bronchus without endobronchial lesion. Endobronchial fine-needle biopsies could not deliver a final diagnosis. The patient underwent upper lobectomy by thoracotomy. Histopathology revealed a benign intrapulmonary schwannoma. Although rare, intermediate FDG uptake in the settings of a pulmonary mass should include schwannoma in the differential diagnosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

0 Abstract L'incidence du mélanome est en nette augmentation en Europe et aux Etats-Unis. La Chirurgie peut être curative au stade précoce de la maladie,la radiothérapie se pratique À visée palliative, les chimiothérapies n'ont montré que peu d'effet. Les progress actuels se font via l'immunothérapie. Des traitements par l'interleukine-2 et l'interféron-α se sont montrés efficaces chez certains patients, mais leur utilisation est limitée par leur forte toxicité. Depuis 2011, en Suisse, une nouvelle molécule a été mise sur le marché, l'ipilimumab (Yervoy®). Il s'agit d'un anticorps! monoclonal humain dirigé contre le CTLA4. Il en résulte une activation non spécifique du système immunitaire. Une étude randomisée de phase IIIa été conduite au Etats-Unis. Elle démontre une augmentation de la survie chez les patients atteints de melanoma métastatique traits par ipilimumab, sans traitement préalable des métastases. Le but de cette etude est de determiner s'il est possible, par le biais de l'imagerie PET-CTau 18F-FDG, de prédire la réponse individuelle au traitement par ipilimumab, afin d'optimiser la prise en charge de ces patients. 0.1 Méthode Les patients atteints de mélanome métastatique sont exposés au traitement d'ipilimumab selon les recommandations de Bristol-Myers Squibb. Puis ils effectuent des PET-CT au F-18-FDG selon! le! protocole (CER 400/11, annexé) de l'étude. Les images sont!analysées selon les critères PERCIST (PETResponse Criterias In Solid Tumors) et le TLG (Total Lesion Glycolysis) est calculé. Parallèlement, des prises de sang sont effectuées et les échantillons sont analysés à l'institut Ludwig (LICR, Unil) selon les critères imRC qui determinant la réponse immunologique au traitement. 0.2 Résultats Nous notons une discrépance dans les résultats. Lorsque nous observons une maladie stable avec les critères immunologiques imRC, nous observons une maladie progressive avec lescritères PERCIST. 0.3 Discussion - Conclusion Nous n'avons pu faire entrer que cinq patients dans l'étude, dont trois étaient vivants à trois mois, ce qui a restreint le nombre de données analysables. Les discrépances que nous observons dans nos résultats pourraient être dues au fait que le PET-CT au 18FDG ne nous permet pas de différencier l'activité tumorale de l'activité inflammatoire péri-tumorale. Ce biais pourrait être à l'avenir prévenu en utilisant du 18FLT, un marqueur plus sélectif des cellules tumorales.L'analyse desimages avec les critères de total-lesion glycolysis a été impossible au vu du nombre de lésions que présentaient certains patients. Les critères PERCIST exigent un protocole d'acquisition très strict. La corrélation entre les images, les données immunologiques et la clinique mérite d'être suivie sur le long terme, car il pourrait y avoir une réponse positive plus tardive du traitement par ipilimumab.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction: Intraoperative EMG based neurophysiological monitoring is increasingly used to assist pedicle screw insertion. We carried out a study comparing the final screw position in the pedicle measured on CT images in relation to its corresponding intraoperative muscle compound action potential (CMAP) values. Material and methods: A total of 189 screws were inserted in thoracolumbar spines of 31 patients during instrumented fusion under EMG control. An observer, blinded to the CMAP value, assessed the horizontal and vertical 'screw edge to pedicle edge' distance perpendicular to the longitudinal axis of the screw on reformatted CT reconstructions using OsiriX software. These distances were analysed with their corresponding CMAP values. Data from 62 thoracic and 127 lumbar screws were processed separately. Interobserver reliability of distance measurements was assessed. Results: No patient suffered neurological injury secondary to screw insertion. Distance measurements were reliable (paired t-test, P = 0.13/0.98 horizontal/vertical). Two screws had their position altered due to low CMAP values suggesting close proximity of nerve tissue. Seventy five percent of screws had CMAP results above 10mA and had an average distance of 0.35cm (SD 0.23) horizontally and 0.46cm (SD 0.26) vertically from the pedicle edge. Additional 12% had a distance from the edge of the pedicle less than 0mm indicating cortical breach but had CMAP values above 10mA. A poor correlation between CMAP values and screw position was found. Discussion: In this study CMAP values above 10mA indicated correct screw position in the majority of cases. The zone of 10-20mA CMAP carries highest risk of a misplaced screw despite high CMAP value (17% of screws this CMAP range). In order to improve accuracy of EMG predictive value further research is warranted including improvement of probing techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Patients with unknown stroke onset are generally excluded from acute recanalisation treatments. We designed a pilot study to assess feasibility of a trial of perfusion computed tomography (PCT)-guided thrombolysis in patients with ischemic tissue at risk of infarction and unknown stroke onset. METHODS: Patients with a supratentorial stroke of unknown onset in the middle cerebral artery territory and significant volume of at-risk tissue on PCT were randomized to intravenous thrombolysis with alteplase (0.9 mg/kg) or placebo. Feasibility endpoints were randomization and blinded treatment of patients within 2 h after hospital arrival, and the correct application (estimation) of the perfusion imaging criteria. RESULTS: At baseline, there was a trend towards older age [69.5 (57-78) vs. 49 (44-78) years] in the thrombolysis group (n = 6) compared to placebo (n = 6). Regarding feasibility, hospital arrival to treatment delay was above the allowed 2 h in three patients (25%). There were two protocol violations (17%) regarding PCT, both underestimating the predicted infarct in patients randomized in the placebo group. No symptomatic hemorrhage or death occurred during the first 7 days. Three of the four (75%) and one of the five (20%) patients were recanalized in the thrombolysis and placebo group respectively. The volume of non-infarcted at-risk tissue was 84 (44-206) cm(3) in the treatment arm and 29 (8-105) cm(3) in the placebo arm. CONCLUSIONS: This pilot study shows that a randomized PCT-guided thrombolysis trial in patients with stroke of unknown onset may be feasible if issues such as treatment delays and reliable identification of tissue at risk of infarction tissue are resolved. Safety and efficiency of such an approach need to be established.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the effects of recent advances in magnetic resonance imaging (MRI) radiofrequency (RF) coil and parallel imaging technology on brain volume measurement consistency. MATERIALS AND METHODS: In all, 103 whole-brain MRI volumes were acquired at a clinical 3T MRI, equipped with a 12- and 32-channel head coil, using the T1-weighted protocol as employed in the Alzheimer's Disease Neuroimaging Initiative study with parallel imaging accelerations ranging from 1 to 5. An experienced reader performed qualitative ratings of the images. For quantitative analysis, differences in composite width (CW, a measure of image similarity) and boundary shift integral (BSI, a measure of whole-brain atrophy) were calculated. RESULTS: Intra- and intersession comparisons of CW and BSI measures from scans with equal acceleration demonstrated excellent scan-rescan accuracy, even at the highest acceleration applied. Pairs-of-scans acquired with different accelerations exhibited poor scan-rescan consistency only when differences in the acceleration factor were maximized. A change in the coil hardware between compared scans was found to bias the BSI measure. CONCLUSION: The most important findings are that the accelerated acquisitions appear to be compatible with the assessment of high-quality quantitative information and that for highest scan-rescan accuracy in serial scans the acquisition protocol should be kept as consistent as possible over time. J. Magn. Reson. Imaging 2012;36:1234-1240. ©2012 Wiley Periodicals, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

With the advances in terms of perfusion imaging, the "time is brain" approach used for acute reperfusion therapy in ischemic stroke patients is slowly being replaced by a "penumbra is brain" or "imaging is brain" approach. But the concept of penumbra-guided reperfusion therapy has not been validated. The lack of standardization in penumbral imaging is one of the main contributing factors for this absence of validation. This article reviews the issues underlying the lack of standardization of perfusion-CT for penumbra imaging, and offers avenues to remedy this situation

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Despite use in clinical practice and trials of thrombolysis, a non-contrast CT is not sensitive for identifying penumbral tissue in acute stroke. This study evaluated how it compares with physiological imaging using CT perfusion.Methods 40 imaging datasets with non-contrast CT (NCCT) and perfusion CT (CTP) were retrospectively identified. 2 sets of observers (n¼6) and a neuroradiologist made a blind evaluation of the images. Inter-observer agreement was calculated for identifying ischaemic change on NCCT, and abnormalities on cerebral blood flow, time to peak and cerebral blood volume maps. A prospective cohort of 73 patients with anterior circulation cortical strokes were thrombolysed based on qualitative assessment of penumbral tissue on CTP within 3 h of stroke onset. Functional outcome was assessed at 3 months.Results Inter-rater agreement was moderate (k¼0.54) for early ischaemic change on NCCT. Perfusion maps improved this to substantial for deficit in cerebral blood volume (k¼0.67) and almost perfect for time to peak and cerebral blood flow (both k¼0.87). In the prospective arm, 58.9% of patients with cortical strokes were thrombolysed. There was no significant difference in attainment of complete recovery (p¼0.184) between the thrombolysed and nonthrombolysed group.Conclusions We demonstrate how perfusion CT aids clinical decision- making in acute stroke. Good functional outcomes from thrombolysis can be safely achieved using this physiologically informed approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RATIONALE AND OBJECTIVES: Dose reduction may compromise patients because of a decrease of image quality. Therefore, the amount of dose savings in new dose-reduction techniques needs to be thoroughly assessed. To avoid repeated studies in one patient, chest computed tomography (CT) scans with different dose levels were performed in corpses comparing model-based iterative reconstruction (MBIR) as a tool to enhance image quality with current standard full-dose imaging. MATERIALS AND METHODS: Twenty-five human cadavers were scanned (CT HD750) after contrast medium injection at different, decreasing dose levels D0-D5 and respectively reconstructed with MBIR. The data at full-dose level, D0, have been additionally reconstructed with standard adaptive statistical iterative reconstruction (ASIR), which represented the full-dose baseline reference (FDBR). Two radiologists independently compared image quality (IQ) in 3-mm multiplanar reformations for soft-tissue evaluation of D0-D5 to FDBR (-2, diagnostically inferior; -1, inferior; 0, equal; +1, superior; and +2, diagnostically superior). For statistical analysis, the intraclass correlation coefficient (ICC) and the Wilcoxon test were used. RESULTS: Mean CT dose index values (mGy) were as follows: D0/FDBR = 10.1 ± 1.7, D1 = 6.2 ± 2.8, D2 = 5.7 ± 2.7, D3 = 3.5 ± 1.9, D4 = 1.8 ± 1.0, and D5 = 0.9 ± 0.5. Mean IQ ratings were as follows: D0 = +1.8 ± 0.2, D1 = +1.5 ± 0.3, D2 = +1.1 ± 0.3, D3 = +0.7 ± 0.5, D4 = +0.1 ± 0.5, and D5 = -1.2 ± 0.5. All values demonstrated a significant difference to baseline (P < .05), except mean IQ for D4 (P = .61). ICC was 0.91. CONCLUSIONS: Compared to ASIR, MBIR allowed for a significant dose reduction of 82% without impairment of IQ. This resulted in a calculated mean effective dose below 1 mSv.