297 resultados para CT colonography (virtual colonoscopy)


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Colonoscopy is generally performed with the patient sedated and receiving analgesics. However, the benefit of the most often used combination of intravenous midazolam and pethidine on patient tolerance and pain and its cardiorespiratory risk have not been fully defined. METHODS: In this double-blind prospective study, 150 outpatients undergoing routine colonoscopy were randomly assigned to receive either (1) low-dose midazolam (35 micrograms/kg) and pethidine (700 micrograms/kg in 48 patients, 500 micrograms/kg in 102 patients), (2) midazolam and placebo pethidine, or (3) pethidine and placebo midazolam. RESULTS: Tolerance (visual analog scale, 0 to 100 points: 0 = excellent; 100 = unbearable) did not improve significantly more in group 1 compared with group 2 (7 points; 95% confidence interval [-2-17]) and group 3 (2 points; 95% confidence interval [-7-12]). Similarly, pain was not significantly improved in group 1 as compared with the other groups. Male gender (p < 0.001) and shorter duration of the procedure (p = 0.004), but not amnesia, were associated with better patient tolerance and less pain. Patient satisfaction was similar in all groups. Oxygen desaturation and hypotension occurred in 33% and 11%, respectively, with a similar frequency in all three groups. CONCLUSIONS: In this study, the combination of low-dose midazolam and pethidine does not improve patient tolerance and lessen pain during colonoscopy as compared with either drug given alone. When applying low-dose midazolam, oxygen desaturation and hypotension do not occur more often after combined use of both drugs. For the individual patient, sedation and analgesia should be based on the endoscopist's clinical judgement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Combined positron emission tomography and computed tomography (PET/CT) scanners play a major role in medicine for in vivo imaging in an increasing number of diseases in oncology, cardiology, neurology, and psychiatry. With the advent of short-lived radioisotopes other than 18F and newer scanners, there is a need to optimize radioisotope activity and acquisition protocols, as well as to compare scanner performances on an objective basis. The Discovery-LS (D-LS) was among the first clinical PET/CT scanners to be developed and has been extensively characterized with older National Electrical Manufacturer Association (NEMA) NU 2-1994 standards. At the time of publication of the latest version of the standards (NU 2-2001) that have been adapted for whole-body imaging under clinical conditions, more recent models from the same manufacturer, i.e., Discovery-ST (D-ST) and Discovery-STE (D-STE), were commercially available. We report on the full characterization both in the two- and three-dimensional acquisition mode of the D-LS according to latest NEMA NU 2-2001 standards (spatial resolution, sensitivity, count rate performance, accuracy of count losses, and random coincidence correction and image quality), as well as a detailed comparison with the newer D-ST widely used and whose characteristics are already published.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Evidence-based information on travel associated mortality is scarce. Perception, intuition and the availability of interventions such as vaccinations and chemoprophylaxis often guide pre-travel advice. Important risks including accidents and cardiovascular events are not routinely included in pre-travel consultations although they cause more fatalities and costs than infectious diseases. The increased risk of sustaining a road accident in poor economy countries should always be mentioned. The general practitioner is further best placed to discuss possible problems of travellers with chronic diseases before travel.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Previous published studies have shown significant variations in colonoscopy performance, even when medical factors are taken into account. This study aimed to examine the role of nonmedical factors (ie, embodied in health care system design) as possible contributors to variations in colonoscopy performance. METHODS: Patient data from a multicenter observational study conducted between 2000 and 2002 in 21 centers in 11 western countries were used. Variability was captured through 2 performance outcomes (diagnostic yield and colonoscopy withdrawal time), jointly studied as dependent variables, using a multilevel 2-equation system. RESULTS: Results showed that open-access systems and high-volume colonoscopy centers were independently associated with a higher likelihood of detecting significant lesions and longer withdrawal durations. Fee for service (FFS) payment was associated with shorter withdrawal durations, and so had an indirect negative impact on the diagnostic yield. Teaching centers exhibited lower detection rates and longer withdrawal times. CONCLUSIONS: Our results suggest that gatekeeping colonoscopy is likely to miss patients with significant lesions and that developing specialized colonoscopy units is important to improve performance. Results also suggest that FFS may result in a lower quality of care in colonoscopy practice and highlight the fact that longer withdrawal times do not necessarily indicate higher quality in teaching centers.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND STUDY AIMS: To summarize the published literature on assessment of appropriateness of colonoscopy for investigation of chronic diarrhea, management of patients with known inflammatory bowel disease (IBD), and for colorectal cancer (CRC) surveillance in such patients, and to report report appropriateness criteria developed by an expert panel, the 2008 European Panel on the Appropriateness of Gastrointestinal Endoscopy, EPAGE II. METHODS: A systematic search of guidelines, systematic reviews, and primary studies regarding the evaluation of chronic diarrhea, the management of IBD, and colorectal cancer surveillance in IBD was performed. The RAND/UCLA Appropriateness Method was applied to develop appropriateness criteria for colonoscopy for these conditions. RESULTS: According to the literature, colonoscopic evaluation may be justified for patients aged > 50 years with recent-onset chronic diarrhea or with alarm symptoms. Surveillance colonoscopy for CRC should be offered to all patients with extensive ulcerative colitis or colonic Crohn's disease of 8 years' duration, and to all patients with less extensive disease of 15 years' duration. Intervals for surveillance colonoscopy depend on duration of evolution, initial diagnosis, and histological findings. The EPAGE II criteria also confirmed the appropriateness of diagnostic colonoscopy for diarrhea of > 4 weeks' duration. They also suggest that, in addition to assessing extent of IBD by colonoscopy, further colonoscopic examination is appropriate in the face of persistent or worsening symptoms. Surveillance colonoscopy in IBD patients was generally appropriate after a lapse of 2 years. In the presence of dysplasia at previous colonoscopy, it was not only appropriate but necessary. CONCLUSIONS: Despite or perhaps because of the limitations of the available published studies, the panel-based EPAGE II (http://www.epage.ch) criteria can help guide appropriate colonoscopy use in the absence of strong evidence from the literature.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Prospective data describing the appropriateness of use of colonoscopy based on detailed panel-based clinical criteria are not available. METHODS: In a cohort of 553 consecutive patients referred for colonoscopy to two university-based Swiss outpatient clinics, the percentage of patients who underwent colonoscopy for appropriate, equivocal, and inappropriate indications and the relationship between appropriateness of use and the presence of relevant endoscopic lesions was prospectively assessed. This assessment was based on criteria of the American Society for Gastrointestinal Endoscopy and explicit American and Swiss criteria developed in 1994 by a formal panel process using the RAND/UCLA appropriateness method. RESULTS: The procedures were rated appropriate or equivocal in 72.2% by criteria of the American Society for Gastrointestinal Endoscopy, in 68.5% by explicit American criteria, and in 74.4% by explicit Swiss criteria (not statistically significant, NS). Inappropriate use (overuse) of colonoscopy was found in 27.8%, 31.5%, and 25.6%, respectively (NS). The proportion of appropriate procedures was higher with increasing age. Almost all reasons for using colonoscopy could be assessed by the two explicit criteria sets, whereas 28.4% of reasons for using colonoscopy could not be evaluated by the criteria of the American Society for Gastrointestinal Endoscopy (p < 0.0001). The probability of finding a relevant endoscopic lesion was distinctly higher in the procedures rated appropriate or equivocal than in procedures judged inappropriate. CONCLUSIONS: The rate of inappropriate use of colonoscopy is substantial in Switzerland. Explicit criteria allow assessment of almost all indications encountered in clinical practice. In this study, all sets of appropriateness criteria significantly enhanced the probability of finding a relevant endoscopic lesion during colonoscopy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Partial splenectomy in children is a good surgical option for hematological diseases and focal splenic tumors because it allows the preservation of the spleen's immunological function. Furthermore, it can be performed by laparoscopy in children as it is a safe procedure, offering the benefits of a minimally invasive approach. MATERIALS AND METHODS: The software VR-render LE version 0.81 is a system that enables the visualization of bidimentional 3D images with magnification of anatomical details. We have applied this system to five cases of non-parasitic splenic cysts before laparoscopic partial splenectomy. RESULTS: The images obtained with VR rendering software permitted the preoperative reconstruction of the vascularization of the splenic hilum, allowing the surgeon safe vessel control during laparoscopic procedures. All five partial splenectomies were carried out with no complications or major blood loss. CONCLUSIONS: Laparoscopic partial splenectomy should be a first choice procedure because it is feasible, reproducible, and safe for children; furthermore, it preserves enough splenic tissue thereby preventing post-splenectomy infections. Volume rendering provides high anatomical resolution and can be useful in guiding the surgical procedure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The objective of our study was to establish a standardized procedure for postmortem whole-body CT-based angiography with lipophilic and hydrophilic contrast media solutions and to compare the results of these two methods. MATERIALS AND METHODS: Minimally invasive postmortem CT angiography was performed on 10 human cadavers via access to the femoral blood vessels. Separate perfusion of the arterial and venous systems was established with a modified heart-lung machine using a mixture of an oily contrast medium and paraffin (five cases) and a mixture of a water-soluble contrast medium with polyethylene glycol (PEG) 200 in the other five cases. Imaging was executed with an MDCT scanner. RESULTS: The minimally invasive femoral approach to the vascular system provided a good depiction of lesions of the complete vascular system down to the level of the small supplying vessels. Because of the enhancement of well-vascularized tissues, angiography with the PEG-mixed contrast medium allowed the detection of tissue lesions and the depiction of vascular abnormalities such as pulmonary embolisms or ruptures of the vessel wall. CONCLUSION: The angiographic method with a water-soluble contrast medium and PEG as a contrast-agent dissolver showed a clearly superior quality due to the lack of extravasation through the gastrointestinal vascular bed and the enhancement of soft tissues (cerebral cortex, myocardium, and parenchymal abdominal organs). The diagnostic possibilities of these findings in cases of antemortem ischemia of these tissues are not yet fully understood.