350 resultados para Body sensitivity
Resumo:
OBJECTIVE: To evaluate the effect of a 4-day carbohydrate overfeeding on whole body net de novo lipogenesis and on markers of de novo lipogenesis in subcutaneous adipose tissue of healthy lean humans. RESEARCH METHODS AND PROCEDURES: Nine healthy lean volunteers (five men and four women) were studied after 4 days of either isocaloric feeding or carbohydrate overfeeding. On each occasion, they underwent a metabolic study during which their energy expenditure and net substrate oxidation rates (indirect calorimetry), and the fractional activity of the pentose-phosphate pathway in subcutaneous adipose tissue (subcutaneous microdialysis with 1,6(13)C2,6,6(2)H2 glucose) were assessed before and after administration of glucose. Adipose tissue biopsies were obtained at the end of the experiments to monitor mRNAs of key lipogenic enzymes. RESULTS: Carbohydrate overfeeding increased basal and postglucose energy expenditure and net carbohydrate oxidation. Whole body net de novo lipogenesis after glucose loading was markedly increased at the expense of glycogen synthesis. Carbohydrate overfeeding also increased mRNA levels for the key lipogenic enzymes sterol regulatory element-binding protein-1c, acetyl-CoA carboxylase, and fatty acid synthase. The fractional activity of adipose tissue pentose-phosphate pathway was 17% to 22% and was not altered by carbohydrate overfeeding. DISCUSSION: Carbohydrate overfeeding markedly increased net de novo lipogenesis at the expense of glycogen synthesis. An increase in mRNAs coding for key lipogenic enzymes suggests that de novo lipogenesis occurred, at least in part, in adipose tissue. The pentose-phosphate pathway is active in adipose tissue of healthy humans, consistent with an active role of this tissue in de novo lipogenesis.
Resumo:
Current research on sleep using experimental animals is limited by the expense and time-consuming nature of traditional EEG/EMG recordings. We present here an alternative, noninvasive approach utilizing piezoelectric films configured as highly sensitive motion detectors. These film strips attached to the floor of the rodent cage produce an electrical output in direct proportion to the distortion of the material. During sleep, movement associated with breathing is the predominant gross body movement and, thus, output from the piezoelectric transducer provided an accurate respiratory trace during sleep. During wake, respiratory movements are masked by other motor activities. An automatic pattern recognition system was developed to identify periods of sleep and wake using the piezoelectric generated signal. Due to the complex and highly variable waveforms that result from subtle postural adjustments in the animals, traditional signal analysis techniques were not sufficient for accurate classification of sleep versus wake. Therefore, a novel pattern recognition algorithm was developed that successfully distinguished sleep from wake in approximately 95% of all epochs. This algorithm may have general utility for a variety of signals in biomedical and engineering applications. This automated system for monitoring sleep is noninvasive, inexpensive, and may be useful for large-scale sleep studies including genetic approaches towards understanding sleep and sleep disorders, and the rapid screening of the efficacy of sleep or wake promoting drugs.
Resumo:
BACKGROUND/OBJECTIVES: (1) To cross-validate tetra- (4-BIA) and octopolar (8-BIA) bioelectrical impedance analysis vs dual-energy X-ray absorptiometry (DXA) for the assessment of total and appendicular body composition and (2) to evaluate the accuracy of external 4-BIA algorithms for the prediction of total body composition, in a representative sample of Swiss children. SUBJECTS/METHODS: A representative sample of 333 Swiss children aged 6-13 years from the Kinder-Sportstudie (KISS) (ISRCTN15360785). Whole-body fat-free mass (FFM) and appendicular lean tissue mass were measured with DXA. Body resistance (R) was measured at 50 kHz with 4-BIA and segmental body resistance at 5, 50, 250 and 500 kHz with 8-BIA. The resistance index (RI) was calculated as height(2)/R. Selection of predictors (gender, age, weight, RI4 and RI8) for BIA algorithms was performed using bootstrapped stepwise linear regression on 1000 samples. We calculated 95% confidence intervals (CI) of regression coefficients and measures of model fit using bootstrap analysis. Limits of agreement were used as measures of interchangeability of BIA with DXA. RESULTS: 8-BIA was more accurate than 4-BIA for the assessment of FFM (root mean square error (RMSE)=0.90 (95% CI 0.82-0.98) vs 1.12 kg (1.01-1.24); limits of agreement 1.80 to -1.80 kg vs 2.24 to -2.24 kg). 8-BIA also gave accurate estimates of appendicular body composition, with RMSE < or = 0.10 kg for arms and < or = 0.24 kg for legs. All external 4-BIA algorithms performed poorly with substantial negative proportional bias (r> or = 0.48, P<0.001). CONCLUSIONS: In a representative sample of young Swiss children (1) 8-BIA was superior to 4-BIA for the prediction of FFM, (2) external 4-BIA algorithms gave biased predictions of FFM and (3) 8-BIA was an accurate predictor of segmental body composition.
Comparison of three commercially available radio frequency coils for human brain imaging at 3 Tesla.
Resumo:
OBJECTIVE: To evaluate a transverse electromagnetic (TEM), a circularly polarized (CP) (birdcage), and a 12-channel phased array head coil at the clinical field strength of B0 = 3T in terms of signal-to-noise ratio (SNR), signal homogeneity, and maps of the effective flip angle alpha. MATERIALS AND METHODS: SNR measurements were performed on low flip angle gradient echo images. In addition, flip angle maps were generated for alpha(nominal) = 30 degrees using the double angle method. These evaluation steps were performed on phantom and human brain data acquired with each coil. Moreover, the signal intensity variation was computed for phantom data using five different regions of interest. RESULTS: In terms of SNR, the TEM coil performs slightly better than the CP coil, but is second to the smaller 12-channel coil for human data. As expected, both the TEM and the CP coils show superior image intensity homogeneity than the 12-channel coil, and achieve larger mean effective flip angles than the combination of body and 12-channel coil with reduced radio frequency power deposition. CONCLUSION: At 3T the benefits of TEM coil design over conventional lumped element(s) coil design start to emerge, though the phased array coil retains an advantage with respect to SNR performance.
Resumo:
BACKGROUND: The factors that contribute to increasing obesity rates in human immunodeficiency virus (HIV)-positive persons and to body mass index (BMI) increase that typically occurs after starting antiretroviral therapy (ART) are incompletely characterized. METHODS: We describe BMI trends in the entire Swiss HIV Cohort Study (SHCS) population and investigate the effects of demographics, HIV-related factors, and ART on BMI change in participants with data available before and 4 years after first starting ART. RESULTS: In the SHCS, overweight/obesity prevalence increased from 13% in 1990 (n = 1641) to 38% in 2012 (n = 8150). In the participants starting ART (n = 1601), mean BMI increase was 0.92 kg/m(2) per year (95% confidence interval, .83-1.0) during year 0-1 and 0.31 kg/m(2) per year (0.29-0.34) during years 1-4. In multivariable analyses, annualized BMI change during year 0-1 was associated with older age (0.15 [0.06-0.24] kg/m(2)) and CD4 nadir <199 cells/µL compared to nadir >350 (P < .001). Annualized BMI change during years 1-4 was associated with CD4 nadir <100 cells/µL compared to nadir >350 (P = .001) and black compared to white ethnicity (0.28 [0.16-0.37] kg/m(2)). Individual ART combinations differed little in their contribution to BMI change. CONCLUSIONS: Increasing obesity rates in the SHCS over time occurred at the same time as aging of the SHCS population, demographic changes, earlier ART start, and increasingly widespread ART coverage. Body mass index increase after ART start was typically biphasic, the BMI increase in year 0-1 being as large as the increase in years 1-4 combined. The effect of ART regimen on BMI change was limited.
Resumo:
Our objective was a prospective comparison of MR enteroclysis (MRE) with multidetector spiral-CT enteroclysis (MSCTE). Fifty patients with various suspected small bowel diseases were investigated by MSCTE and MRE. The MSCTE was performed using slices of 2.5 mm, immediately followed by MRE, obtaining T1- and T2-weighted sequences, including gadolinium-enhanced acquisition with fat saturation. Three radiologists independently evaluated MSCTE and MRE searching for 12 pathological signs. Interobserver agreement was calculated. Sensitivities and specificities resulted from comparison with pathological results ( n=29) and patient's clinical evolution ( n=21). Most pathological signs, such as bowel wall thickening (BWT), bowel wall enhancement (BWE) and lymphadenopathy (ADP), showed better interobserver agreement on MSCTE than on MRE (BWT: 0.65 vs 0.48; BWE: 0.51 vs 0.37; ADP: 0.52 vs 0.15). Sensitivity of MSCTE was higher than that of MRE in detecting BWT (88.9 vs 60%), BWE (78.6 vs 55.5%) and ADP (63.8 vs 14.3%). Wilcoxon signed-rank test revealed significantly better sensitivity of MSCTE than that of MRE for each observer ( p=0.028, p=0.046, p=0.028, respectively). Taking the given study design into account, MSCTE provides better sensitivity in detecting lesions of the small bowel than MRE, with higher interobserver agreement.
Resumo:
Body mass and body condition are often tightly linked to animal health and fitness in the wild and thus are key measures for ecophysiologists and behavioral ecologists. In some animals, such as large seabird species, obtaining indexes of structural size is relatively easy, whereas measuring body mass under specific field circumstances may be more of a challenge. Here, we suggest an alternative, easily measurable, and reliable surrogate of body mass in field studies, that is, body girth. Using 234 free-living king penguins (Aptenodytes patagonicus) at various stages of molt and breeding, we measured body girth under the flippers, body mass, and bill and flipper length. We found that body girth was strongly and positively related to body mass in both molting (R(2) = 0.91) and breeding (R(2) = 0.73) birds, with the mean error around our predictions being 6.4%. Body girth appeared to be a reliable proxy measure of body mass because the relationship did not vary according to year and experimenter, bird sex, or stage within breeding groups. Body girth was, however, a weak proxy of body mass in birds at the end of molt, probably because most of those birds had reached a critical depletion of energy stores. Body condition indexes established from ordinary least squares regressions of either body girth or body mass on structural size were highly correlated (r(s) = 0.91), suggesting that body girth was as good as body mass in establishing body condition indexes in king penguins. Body girth may prove a useful proxy to body mass for estimating body condition in field investigations and could likely provide similar information in other penguins and large animals that may be complicated to weigh in the wild.
Resumo:
Objective: to assess the between and within-device reproducibility, as well as within-day variability of body fat measurements. Methods: body fat percentage (%BF) was measured twice on seventeen female students aged between 18 and 20 with a body mass index of 21.9 22.6 kg/m2 (mean SD) using seven bipolar bioelectrical impedance devices (BF-306) according to the manufacturer's recommendations. Each student was also measured each hour between 7:00 and 22:00. Statistical analysis was conducted using a general linear model for repeated measurements. Results: the correlation between first and second measurements was very high (Pearson r between 0.985 and 1.000, p<0.001), as well as the correlation between devices (Pearson r between 0.986 and 0.999, all p<0.001). Repeated measurements analysis showed no differences were between devices (F test=0.83, p=0.59) or readings (first vs. second: F test=0.12, p=0.74). Conversely, significant differences were found between assessment periods throughout the day, measurements made in the morning being lower than those made in the afternoon. Assuming an overall daily average of 100 (based on all measurements), the values were 95.8 3.2 (mean SD) at 8:00 versus 101.3 3.0 at 20:00, corresponding to a mean change of 2.2 1.1 in %BF (F test for repeated values=6.58, p<0.001). Conclusions: the between and within-device reproducibility for measuring body fat is high, enabling the use of multiple devices in a single study. Conversely, small but significant changes in body fat measurements occur during the day, urging body fat measurements to be performed at fixed times.
Resumo:
The slow vacuolar (SV) channel, a Ca2+-regulated vacuolar cation conductance channel, in Arabidopsis thaliana is encoded by the single-copy gene AtTPC1. Although loss-of-function tpc1 mutants were reported to exhibit a stoma phenotype, knowledge about the underlying guard cell-specific features of SV/TPC1 channels is still lacking. Here we demonstrate that TPC1 transcripts and SV current density in guard cells were much more pronounced than in mesophyll cells. Furthermore, the SV channel in motor cells exhibited a higher cytosolic Ca2+ sensitivity than in mesophyll cells. These distinct features of the guard cell SV channel therefore probably account for the published stomatal phenotype of tpc1-2.
Resumo:
OBJECTIVE: Low and high body mass index (BMI) values have been shown to increase health risks and mortality and result in variations in fat-free mass (FFM) and body fat mass (BF). Currently, there are no published ranges for a fat-free mass index (FFMI; kg/m(2)), a body fat mass index (BFMI; kg/m(2)), and percentage of body fat (%BF). The purpose of this population study was to determine predicted FFMI and BFMI values in subjects with low, normal, overweight, and obese BMI. METHODS: FFM and BF were determined in 2986 healthy white men and 2649 white women, age 15 to 98 y, by a previously validated 50-kHz bioelectrical impedance analysis equation. FFMI, BFMI, and %BF were calculated. RESULTS: FFMI values were 16.7 to 19.8 kg/m(2) for men and 14.6 to 16.8 kg/m(2) for women within the normal BMI ranges. BFMI values were 1.8 to 5.2 kg/m(2) for men and 3.9 to 8.2 kg/m(2) for women within the normal BMI ranges. BFMI values were 8.3 and 11.8 kg/m(2) in men and women, respectively, for obese BMI (>30 kg/m(2)). Normal ranges for %BF were 13.4 to 21.7 and 24.6 to 33.2 for men and women, respectively. CONCLUSION: BMI alone cannot provide information about the respective contribution of FFM or fat mass to body weight. This study presents FFMI and BFMI values that correspond to low, normal, overweight, and obese BMIs. FFMI and BFMI provide information about body compartments, regardless of height.
Resumo:
Total body irradiation (TBI) has an established role as preparative regimen for bone-marrow transplantation in the treatment of hematological malignancies. Many randomized trials demonstrated that the clinical outcomes obtained from the association of TBI and cyclophosphamide are equivalent, or, sometimes, better than those based on chemotherapeutic agents. Despite the therapeutic progress of the last years, and the consequent improvement in the overall survival, this preparative regimen remains always associated with a relatively high rate of acute and late toxicity. In this article, we review the actual indications of TBI in clinical practice, and analyze the technological progress in this domain. We focus on the hypothesis that a selective irradiation of the hematopoietic or lymphoid organs is actually possible with intensity-modulated radiotherapy. Technical limits and preliminary results in terms of acute and late toxicities of intensity-modulated TBI are analyzed. With these new technologies, treatment-related toxicity is not anymore a major limiting factor in the preparative regimens for bone-marrow transplantation, allowing for a larger spectrum of TBI indications, a possible extension to patients older than 50 years, or a dose escalation. Preliminary results warrant, however, further evaluation in clinical trials to better assess the impact of this new approach on disease control and the long-term toxicity.
Resumo:
We report a novel technique for computing diet-induced thermogenesis using data from 24-h respiration chamber measurements of 76 subjects. Physical activity (PA) was determined using a radar system to assess its duration and an accelerometer to evaluate its intensity. The regression line relating PA and energy expenditure facilitated calculation of the integrated thermogenic response to the total energy ingested (11.4% ± 3.8%), which is consistent with the values classically reported in the literature (10%) at the group level.
Resumo:
Purpose: To develop and evaluate a practical method for the quantification of signal-to-noise ratio (SNR) on coronary MR angiograms (MRA) acquired with parallel imaging.Materials and Methods: To quantify the spatially varying noise due to parallel imaging reconstruction, a new method has been implemented incorporating image data acquisition followed by a fast noise scan during which radio-frequency pulses, cardiac triggering and navigator gating are disabled. The performance of this method was evaluated in a phantom study where SNR measurements were compared with those of a reference standard (multiple repetitions). Subsequently, SNR of myocardium and posterior skeletal muscle was determined on in vivo human coronary MRA.Results: In a phantom, the SNR measured using the proposed method deviated less than 10.1% from the reference method for small geometry factors (<= 2). In vivo, the noise scan for a 10 min coronary MRA acquisition was acquired in 30 s. Higher signal and lower SNR, due to spatially varying noise, were found in myocardium compared with posterior skeletal muscle.Conclusion: SNR quantification based on a fast noise scan is a validated and easy-to-use method when applied to three-dimensional coronary MRA obtained with parallel imaging as long as the geometry factor remains low.
Resumo:
RP 59500 is a new injectable streptogramin composed of two synergistic components (quinupristin and dalfopristin) which are active against a number of erythromycin-susceptible and -resistant gram-positive bacteria. The following experiments investigate the ability of RP 59500 to prevent experimental endocarditis due to either of two erythromycin-susceptible streptococcal isolates or their constitutively erythromycin-resistant Tn916 delta E transconjugants. RP 59500 had low MICs (0.125 to 0.5 mg/liter) for all four test organisms and was substantially bactericidal in vitro. Rats with catheter-induced aortic vegetations were given single-dose antibiotic prophylaxis 30 to 60 min before bacterial inoculation through a computerized pump system which permitted the simulation of drug kinetics for humans produced by either 7 mg of RP 59500 per kg of body weight or 1 g of vancomycin. Single-dose RP 59500 prophylaxis successfully prevented endocarditis due to both the erythromycin-susceptible parent strains and their erythromycin-resistant derivatives in rats challenged with the minimal inoculum infecting 90% of controls. In addition, RP 59500 also prevented infection in animals challenged with fivefold-larger inocula of the erythromycin-susceptible parent strains. Vancomycin successfully prevented endocarditis due to any of the four test organisms. These results underline the in vivo efficacy of RP 59500 against both erythromycin-susceptible and -resistant streptococci. Such good results against the resistant strains would not be expected with erythromycin or clindamycin, which are the standard macrolidelincosamide-streptogramin antibiotics used for endocarditis prophylaxis in humans. An oral form of RP 59500 which might advantageously replace some of the older prophylactic regimens is currently being developed.