207 resultados para Blood Gas Monitoring, Transcutaneous


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Nonadherence to treatment is a common problem in the clinical management of hypercholesterolemic patients. This study was carried out with the aim of monitoring the daily compliance to a 6-month course of lipid-lowering therapy, using a microelectronic device, the Medication Event Monitoring System (MEMS), versus pill count. Forty men with primary hypercholesterolemia were prescribed fluvastatin 1 x 40 mg daily, provided in a MEMS package to record the date and time of each opening of the pillbox. Thirty-nine of 40 patients (98%) completed the study. Total cholesterol and LDL cholesterol levels decreased significantly (18% and 25%, p < 0.001) during the 6-month therapy period. A high mean rate of compliance was achieved by MEMS using the following three indexes--compliance to total prescribed dose (88.8% +/- 13.5%), compliance to prescribed days (82.4% +/- 19.5%), and compliance to prescribed time of day (81.86% +/- 19.5%)--and by pill count (93.4% +/- 9.5%). In addition, the MEMS provided some patterns of nonadherence to medication, undetectable by pill count alone, such as a drug holiday in 38% of cases, a drug omission for more than 7 consecutive days in 9% of cases, and, conversely, use of more than the one prescribed daily dose in 47% of cases. A significant correlation between the rate of compliance and the decrease in LDL cholesterol was observed only when the compliance was assessed by MEMS. The results indicate that MEMS is a useful tool for monitoring compliance in clinical practice and may possibly increase adherence to long-term lipid-lowering therapy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Peri-insular hemispherotomy is a surgical technique used in the treatment of drug-resistant epilepsy of hemispheric origin. It is based on the exposure of insula and semi-circular sulci, providing access to the lateral ventricle through a supra- and infra-insular window. From inside the ventricle, a parasagittal callosotomy is performed. The basal and medial portion of the frontal lobe is isolated. Projections to the anterior commissure are interrupted at the time of amygdala resection. The hippocampal tail and fimbria-fornix are disrupted posteriorly. We report our experience of 18 cases treated with this approach. More than half of them presented with congenital epilepsy. Neuronavigation was useful in precisely determining the center and extent of the craniotomy, as well as the direction of tractotomies and callosotomy, allowing minimal exposure and blood loss. Intra-operative monitoring by scalp EEG on the contralateral hemisphere was used to follow the progression of the number of interictal spikes during the disconnection procedure. Approximately 90% of patients were in Engel's Class I. We observed one case who presented with transient postoperative neurological deterioration probably due to CSF overdrainage and documented one case of incomplete disconnection in a patient presenting with hemimegalencephaly who needed a second operation. We observed a good correlation between a significant decrease in the number of spikes at the end of the procedure and seizure outcome. Peri-insular hemispherotomy provides a functional disconnection of the hemisphere with minimal resection of cerebral tissue. It is an efficient technique with a low complication rate. Intra-operative EEG monitoring might be used as a predictive factor of completeness of the disconnection and consequently, seizure outcome.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A gas chromatographic-mass spectrometric method is presented which allows the determination of chlorzoxazone and 6-hydroxychlorzoxazone after derivatization with the reagent N-tert.-butyldimethylsilyl-N-methyltrifluoroacetamide. No interference was observed from endogenous compounds following the extraction of plasma samples from six different human subjects. The standard curves were linear over a working range of 20 to 4000 ng/ml and of 20 to 1000 ng/ml for chlorzoxazone and 6-hydroxychlorzoxazone, respectively. Recoveries ranged from 65 to 97% for the two compounds and intra- and inter-day coefficients of variation were always less than 9%. The limit of quantitation of the method was found to be 5 ng/ml for the two compounds, hence allowing its use for single low dose pharmacokinetics.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECT: Cerebrovascular pressure reactivity is the ability of cerebral vessels to respond to changes in transmural pressure. A cerebrovascular pressure reactivity index (PRx) can be determined as the moving correlation coefficient between mean intracranial pressure (ICP) and mean arterial blood pressure. METHODS: The authors analyzed a database consisting of 398 patients with head injuries who underwent continuous monitoring of cerebrovascular pressure reactivity. In 298 patients, the PRx was compared with a transcranial Doppler ultrasonography assessment of cerebrovascular autoregulation (the mean index [Mx]), in 17 patients with the PET-assessed static rate of autoregulation, and in 22 patients with the cerebral metabolic rate for O(2). Patient outcome was assessed 6 months after injury. RESULTS: There was a positive and significant association between the PRx and Mx (R(2) = 0.36, p < 0.001) and with the static rate of autoregulation (R(2) = 0.31, p = 0.02). A PRx > 0.35 was associated with a high mortality rate (> 50%). The PRx showed significant deterioration in refractory intracranial hypertension, was correlated with outcome, and was able to differentiate patients with good outcome, moderate disability, severe disability, and death. The graph of PRx compared with cerebral perfusion pressure (CPP) indicated a U-shaped curve, suggesting that too low and too high CPP was associated with a disturbance in pressure reactivity. Such an optimal CPP was confirmed in individual cases and a greater difference between current and optimal CPP was associated with worse outcome (for patients who, on average, were treated below optimal CPP [R(2) = 0.53, p < 0.001] and for patients whose mean CPP was above optimal CPP [R(2) = -0.40, p < 0.05]). Following decompressive craniectomy, pressure reactivity initially worsened (median -0.03 [interquartile range -0.13 to 0.06] to 0.14 [interquartile range 0.12-0.22]; p < 0.01) and improved in the later postoperative course. After therapeutic hypothermia, in 17 (70.8%) of 24 patients in whom rewarming exceeded the brain temperature threshold of 37 degrees C, ICP remained stable, but the average PRx increased to 0.32 (p < 0.0001), indicating significant derangement in cerebrovascular reactivity. CONCLUSIONS: The PRx is a secondary index derived from changes in ICP and arterial blood pressure and can be used as a surrogate marker of cerebrovascular impairment. In view of an autoregulation-guided CPP therapy, a continuous determination of a PRx is feasible, but its value has to be evaluated in a prospective controlled trial.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Ethylglucuronide (EtG) is a direct and specific metabolite of ethanol. Its determination in hair is of increasing interest for detecting and monitoring alcohol abuse. The quantification of EtG in hair requires analytical methods showing highest sensitivity and specificity. We present a fully validated method based on gas chromatography-negative chemical ionization tandem mass spectrometry (GC-NCI-MS/MS). The method was validated using French Society of Pharmaceutical Sciences and Techniques (SFSTP) guidelines which are based on the determination of the total measurement error and accuracy profiles. Methods: Washed and powdered hair is extracted in water using an ultrasonic incubation. After purification by Oasis MAX solid phase extraction, the derivatized EtG is detected and quantified by GC-NCI-MS/MS method in the selected reaction monitoring mode. The transitions m/z 347 / 163 and m/z 347 / 119 were used for the quantification and identification of EtG. Four quality controls (QC) prepared with hair samples taken post mortem from 2 subjects with a known history of alcoholism were used. A proficiency test with 7 participating laboratories was first run to validate the EtG concentration of each QC sample. Considering the results of this test, these samples were then used as internal controls for validation of the method. Results: The mean EtG concentrations measured in the 4 QC were 259.4, 130.4, 40.8, and 8.4 pg/mg hair. Method validation has shown linearity between 8.4 and 259.4 pg/mg hair (r2 > 0.999). The lower limit of quantification was set up at 8.4 pg/mg. Repeatability and intermediate precision were found less than 13.2% for all concentrations tested. Conclusion: The method proved to be suitable for routine analysis of EtG in hair. GC-NCI-MS/MS method was then successfully applied to the analysis of EtG in hair samples collected from different alcohol consumers.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: We investigated the incidence and distribution of post-mortem gas detected with multidetector computed tomography (MDCT) to identify factors that could distinguish artifactual gas from cardiac air embolism. MATERIAL AND METHODS: MDCT data of 119 cadavers were retrospectively examined. Gas was semiquantitatively assessed in selected blood vessels, organs, and body spaces (82 total sites). RESULTS: Seventy-four of the 119 cadavers displayed gas (62.2%; CI 95% 52.8-70.9), and 56 (75.7%) displayed gas in the heart. Most gas was detected in the hepatic parenchyma (40%), right heart (38% ventricle, 35% atrium), inferior vena cava (30% infrarenally, 26% suprarenally), hepatic veins (26% left, 29% middle, 22% right), and portal spaces (29%). Male cadavers displayed gas more frequently than female cadavers. Gas was detected 5-84 hours after death; therefore, the post-mortem interval could not reliably predict gas distribution (rho = 0.719, p < 0.0001). We found that a large amount of putrefaction-generated gas in the right heart was associated with aggregated gas bubbles in the hepatic parenchyma (sensitivity = 100%, specificity = 89.7%). In contrast, gas in the left heart (sensitivity = 41.7%, specificity = 100%) or in periumbilical subcutaneous tissues (sensitivity = 50%, specificity = 96.3%) could not predict gas due to putrefaction. CONCLUSION: This study is the first to show that the appearance of post-mortem gas follows a specific distribution pattern. An association between intracardiac gas and hepatic parenchymal gas could distinguish between post-mortem-generated gas and vital air embolism. We propose that this finding provides a key for diagnosing death due to cardiac air embolism.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A new analytical approach for measuring methane in tissues is presented. For the first time, the use of in situ-produced, stably labelled CDH(3) provides a reliable and precise methane quantification. This method was applied to postmortem samples obtained from two victims to help determine the explosion origin. There was evidence of methane in the adipose tissue (82 nmol/g) and cardiac blood (1.3 nmol/g) of one victim, which corresponded to a lethal methane outburst. These results are discussed in the context of the available literature to define an analysis protocol for application in the event of a gas explosion.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Although platelet cytosolic calcium has been shown to decrease during pharmacological treatment of hypertension, there is no evidence that cytosolic calcium also falls during a nonpharmacological reduction in blood pressure. To provide such evidence, we examined prospectively the relation between platelet cytosolic calcium and ambulatory blood pressure during weight reduction in moderately overweight (body mass index [BMI] greater than 25), mildly hypertensive individuals. The experimental group (responders: BMI reduction greater than 5%) consisted of 19 patients who lost 8.5 +/- 2.9 kg (mean +/- SD, p less than 0.05) during a 10-week hypocaloric diet, whereas the control group (nonresponders: BMI reduction less than 5%) consisted of 12 patients who showed no relevant change in body weight (-2.0 +/- 1.3 kg) during the same period of time. The moderate weight loss of the responders decreased blood pressure by 14/5 mm Hg (p less than 0.05), as measured by ambulatory monitoring, which renders a placebo effect unlikely. This nonpharmacological reduction in blood pressure was accompanied by a proportional 11% decrease (p less than 0.05) in platelet cytosolic calcium and also by significant (p less than 0.05) decreases in plasma catecholamines and serum cholesterol. These findings establish the concept of a nonpharmacological reduction in free cytosolic platelet calcium in humans and add further evidence suggesting a link between intracellular calcium homeostasis and blood pressure regulation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: A lipidomic approach was employed in a clinically well-defined cohort of healthy obese women to explore blood lipidome phenotype ascribed to body fat deposition, with emphasis on epicardial adipose tissue (EAT). METHODS: The present investigation delivered a lipidomics signature of epicardial adiposity under healthy clinical conditions using a cohort of 40 obese females (age: 25-45 years, BMI: 28-40 kg/m(2) ) not showing any metabolic disease traits. Lipidomics analysis of blood plasma was employed in combination with in vivo quantitation of mediastinal fat depots by computerized tomography. RESULTS: All cardiac fat depots correlated to indicators of hepatic dysfunctions (ALAT and ASAT), which describe physiological connections between hepatic and cardiac steatosis. Plasma lipidomics encompassed overall levels of lipid classes, fatty acid profiles, and individual lipid species. EAT and visceral fat associated with diacylglycerols (DAG), triglycerides, and distinct phospholipid and sphingolipid species. A pattern of DAG and phosphoglycerols was specific to EAT. CONCLUSIONS: Human blood plasma lipidomics appears to be a promising clinical and potentially diagnostic readout for patient stratification and monitoring. Association of blood lipidomics signature to regio-specific mediastinal and visceral adiposity under healthy clinical conditions may help provide more biological insights into obese patient stratification for cardiovascular disease risks.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

When requesting a blood level measurement in the context of "Therapeutic drug monitoring" (TDM), numerous aspects have to be considered in the pre-analytical and analytical area, as in the integration of associated clinical data. This review presents therapeutic classes for which a clinical benefit of TDM is established or suggested, at least in some settings. For each class of drugs, the main pharmacokinetic, pre-analytical, analytical and clinical aspects are evaluated in the scope of such a monitoring. Each step of the TDM process is important and none should be neglected. Additional clinical trials are however warranted to better establish the exact conditions of use for such a monitoring.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Saffaj et al. recently criticized our method of monitoring carbon dioxide in human postmortem cardiac gas samples using Headspace-Gas Chromatography-Mass Spectrometry. According to the authors, their demonstration, based on the latest SFSTP guidelines (established after 2007 [1,2]) fitted for the validation of drug monitoring bioanalytical methods, has put in evidence potential errors. However, our validation approach was built using SFSTP guidelines established before 2007 [3-6]. We justify the use of these guidelines because of the post-mortem context of the study (and not clinical) and the gaseous state of the sample (and not solid or liquid). Using these guidelines, our validation remains correct.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The purpose of this study was to compare in the individual hypertensive patient the blood pressure lowering effect of a beta-blocking agent i.e. betaxolol with that of a calcium entry blocker, i.e. verapamil. The antihypertensive efficacy of the drugs was evaluated both at the physician's office and by monitoring ambulatory daytime blood pressure using a portable blood pressure recorder (Remler M2000). Seventeen patients with uncomplicated essential hypertension (aged 35-67 years) were treated for two consecutive 6-week periods with either betaxolol, 20 mg/day or a slow-release formulation of verapamil, 240-480 mg/day. The sequence of treatment phases was randomly allocated and a 2-week wash-out period preceded each treatment. Both betaxolol and verapamil had a significant blood pressure lowering effect when assessed at the physician's office. However, ambulatory recorded blood pressures were significantly reduced only with betaxolol. In the presence of a physician, the best responders to betaxolol tended to be also the best responders to verapamil, whereas there was no relationship between the fall in ambulatory recorded blood pressure observed during betaxolol and the corresponding fall during verapamil administration. The blood pressure response to both betaxolol and verapamil was not related to age.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Requesting a blood level measurement of a drug is part of the global approach known as "Therapeutic Drug Monitoring". Diverse situations require this monitoring approach, such as inadequate response to treatment or organ failure. Every drug however does not possess all the characteristics for a TDM program. The therapeutic range of a TDM drug has indeed to be narrow and its interindividual pharmacokinetic variability to be wide. As the development of new drugs is currently slowing down, the precise management of existing treatments certainly deserves progress, but needs however to be applied rationally, starting from a valid indication to blood sampling, and ending with a sound dosage adaptation decision.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Poor compliance with antihypertensive drug regimens is one recognized cause of inadequate blood pressure control. Compliance is difficult to measure, so poor adherence to treatment remains largely undiagnosed in clinical practice. When the therapeutic response to a drug is not the one expected, it is a major challenge for many physicians to decide whether the patient is a non-responder or a non-complier. Poor compliance is therefore often incorrectly interpreted as a lack of response to treatment. Not detecting non-compliance can lead to the wrong measures being taken. Electronic monitoring of compliance provides important longitudinal information about drug-intake behaviour that cannot be obtained in the clinic. Such monitoring can improve both compliance and blood pressure control, and help physicians to make more rational therapeutic decisions. A reliable assessment of compliance could have a great impact on medical costs by preventing unnecessary investigations or dose adaptations in patients who are not taking their drugs adequately, or potentially reducing the number of hospitalizations. Side-effects and lack of effectiveness are two frequent causes of poor compliance. The right choice of antihypertensive drug can therefore contribute to compliance. In this respect, it is important to find a drug regimen that is effective, long-acting and well tolerated. Long-acting antihypertensive drugs that provide good blood pressure control beyond the 24-h dosing period should perhaps be considered as drugs of choice in non-compliant patients with hypertension because they help to prevent the consequences of occasional drug omissions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The clinical demand for a device to monitor Blood Pressure (BP) in ambulatory scenarios with minimal use of inflation cuffs is increasing. Based on the so-called Pulse Wave Velocity (PWV) principle, this paper introduces and evaluates a novel concept of BP monitor that can be fully integrated within a chest sensor. After a preliminary calibration, the sensor provides non-occlusive beat-by-beat estimations of Mean Arterial Pressure (MAP) by measuring the Pulse Transit Time (PTT) of arterial pressure pulses travelling from the ascending aorta towards the subcutaneous vasculature of the chest. In a cohort of 15 healthy male subjects, a total of 462 simultaneous readings consisting of reference MAP and chest PTT were acquired. Each subject was recorded at three different days: D, D+3 and D+14. Overall, the implemented protocol induced MAP values to range from 80 ± 6 mmHg in baseline, to 107 ± 9 mmHg during isometric handgrip maneuvers. Agreement between reference and chest-sensor MAP values was tested by using intraclass correlation coefficient (ICC = 0.78) and Bland-Altman analysis (mean error = 0.7 mmHg, standard deviation = 5.1 mmHg). The cumulative percentage of MAP values provided by the chest sensor falling within a range of ±5 mmHg compared to reference MAP readings was of 70%, within ±10 mmHg was of 91%, and within ±15mmHg was of 98%. These results point at the fact that the chest sensor complies with the British Hypertension Society (BHS) requirements of Grade A BP monitors, when applied to MAP readings. Grade A performance was maintained even two weeks after having performed the initial subject-dependent calibration. In conclusion, this paper introduces a sensor and a calibration strategy to perform MAP measurements at the chest. The encouraging performance of the presented technique paves the way towards an ambulatory-compliant, continuous and non-occlusive BP monitoring system.