26 resultados para liquid phase epitaxy


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Oxygen isotope measurements using SIMS and laser-fluorination methods confirm the presence of concentric and sector zoning in low-temperature (200 degrees C to < 400 degrees C) hydrothermal quartz from Alpine veins. While concentric zoning is most readily explained by changes in the chemical composition of the fluid or temperature of crystallization, the reasons for sector zoning are more difficult to explain. Relative enrichment in (18)O for crystallographically different sectors of quartz corresponds to m > r > z. Sector zoning is, however, largely limited to the exterior zones of crystals and/or to crystals with large Al (> 1000 ppm) and trace element contents, probably formed at temperatures < 250 degrees C. Differences in delta(18)O between the prismatic (m) relative to the rhombohedral (r and z) growth sectors of up to 2 parts per thousand can be explained by a combination of a face-related crystallographic and/or a growth rate control. In contrast, isotopic sector zoning of up to about 1.5 parts per thousand amongst the different rhombohedral faces increases in parallel with the trace element content and is likely to represent disequilibrium growth. This is indicated by non-systematic, up to 2 parts per thousand, differences within single growth zones and the irregular, larger or smaller, delta(18)O values (of several permil) of the exterior compared to the inner zones of the same crystals. Disequilibrium growth may be related to the large trace element content incorporated into the growing quartz at lower temperatures (< 250 degrees C) and/or be related to fluid-vapour separation, allowing crystal growth from both a vapour as well as a liquid phase.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Le but essentiel de notre travail a été d?étudier la capacité du foie, premier organe de métabolisation des xénobiotiques, à dégrader la cocaïne en présence d?éthanol, à l?aide de deux modèles expérimentaux, à savoir un modèle cellulaire (les hépatocytes de rat en suspension) et un modèle acellulaire (modèle reconstitué in vitro à partir d?enzymes purifiées de foie humain). La première partie a pour objectifs de rechercher les voies de métabolisation de la cocaïne qui sont inhibées et / ou stimulées en présence d?éthanol, sur hépatocytes isolés de rat. Dans ce but, une méthode originale permettant de séparer et de quantifier simultanément la cocaïne, le cocaéthylène et huit de leurs métabolites respectifs a été développée par Chromatographie Phase Gazeuse couplée à la Spectrométrie de Masse (CPG / SM). Nos résultats préliminaires indiquent que l?éthanol aux trois concentrations testées (20, 40 et 80 mM) n?a aucun effet sur la cinétique de métabolisation de la cocaïne. Notre étude confirme que l?addition d?éthanol à des cellules hépatiques de rat en suspension supplémentées en cocaïne résulte en la formation précoce de benzoylecgonine et de cocaéthylène. L?apparition retardée d?ecgonine méthyl ester démontre l?activation d?une deuxième voie de détoxification. La production tardive d?ecgonine indique une dégradation de la benzoylecgonine et de l?ecgonine méthyl ester. De plus, la voie d?oxydation intervenant dans l?induction du stress oxydant en produisant de la norcocaïne est tardivement stimulée. Enfin, notre étude montre une métabolisation complète de la concentration initiale en éthanol par les hépatocytes de rat en suspension. La deuxième partie a pour but de déterminer s?il existe d?autres enzymes que les carboxylesterases formes 1 et 2 humaines ayant une capacité à métaboliser la cocaïne seule ou associée à de l?éthanol. Pour ce faire, une méthode de micropurification par chromatographie liquide (Smart System®) a été mise au point. Dans le cadre de nos dosages in situ de la cocaïne, du cocaéthylène, de la benzoylecgonine, de l?acide benzoïque et de la lidocaïne, une technique par Chromatographie Liquide Haute Performance couplée à une Détection par Barrette de Diode (CLHP / DBD) et une méthode de dosage de l?éthanol par Chromatographie Phase Gazeuse couplée à une Détection par Ionisation de Flamme équipée d?un injecteur à espace de tête (espace de tête CPG / DIF) ont été développées. La procédure de purification nous a permis de suspecter la présence d?autres enzymes que les carboxylesterases formes 1 et 2 de foie humain impliquées dans le métabolisme de la cocaïne et déjà isolées. A partir d?un modèle enzymatique reconstitué in vitro, nos résultats préliminaires indiquent que d?autres esterases que les formes 1 et 2 de foie humain sont impliquées dans l?élimination de la cocaïne, produisant benzoylecgonine et ecgonine méthyl ester. De plus, nous avons montré que les sensibilités de ces enzymes à l?éthanol sont variables.<br/><br/>The main purpose of our work was to study the ability of the liver, as the first organ to metabolise xenobiotic substances, to degrade cocaine in the presence of ethanol. In order to do this, we used two experimental models, namely a cellular model (rat liver cells in suspension) and an a-cellular model (model reconstructed in vitro from purified human liver enzymes). The purpose of the first part of our study was to look for cocaine metabolising processes which were inhibited and / or stimulated by the presence of ethanol, in isolated rat liver cells. With this aim in mind, an original method for simultaneously separating and quantifying cocaine, cocaethylene and eight of their respective metabolites was developed by Vapour Phase Chromatography coupled with Mass Spectrometry (VPC / MS). Our preliminary results point out that ethanol at three tested concentrations (20, 40 et 80 mM) have no effect on the kinetic of metabolisation of cocaine. Our study confirms that the addition of alcohol to rat liver cells in suspension, supplemented with cocaine, results in the premature formation of ecgonine benzoyl ester and cocaethylene. The delayed appearance of ecgonine methyl ester shows that a second detoxification process is activated. The delayed production of ecgonine indicates a degradation of the ecgonine benzoyl ester and the ecgonine methyl ester. Moreover, the oxidising process which occurs during the induction of the oxidising stress, producing norcocaine, is stimulated at a late stage. Finally, our study shows the complete metabolisation of the initial alcohol concentration by the rat liver cells in suspension. The second part consisted in determining if enzymes other than human carboxylesterases 1 and 2, able to metabolise cocaine on its own or with alcohol, existed. To do this, a micropurification method us ing liquid phase chromatography (Smart System®) was developed. A technique based on High Performance Liquid Chromatography coupled with a Diode Array Detection (HPLC / DAD) in the in situ proportioning of cocaine, cocaethylene, ecgonine benzoyl ester, benzoic acid and lidocaine, and a method for proportioning alcohol by quantifying the head space using Vapour Phase Chromatography coupled with a Flame Ionisation Detection (head space VPC / FID) were used. The purification procedure pointed to the presence of enzymes other than the human liver carboxylesterases, forms 1 and 2, involved in the metabolism of cocaine and already isolated. The preliminary results drawn from an enzymatic model reconstructed in vitro indicate that human liver carboxylesterases, other than forms 1 and 2, are involved in the elimination of cocaine, producing ecgonine benzoyl ester and ecgonine methyl ester. Moreover, we have shown that the sensitivity of these enzymes to alcohol is variable.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Solid-phase extraction (SPE) in tandem with dispersive liquid-liquid microextraction (DLLME) has been developed for the determination of mononitrotoluenes (MNTs) in several aquatic samples using gas chromatography-flame ionization (GC-FID) detection system. In the hyphenated SPE-DLLME, initially MNTs were extracted from a large volume of aqueous samples (100 mL) into a 500-mg octadecyl silane (C(18) ) sorbent. After the elution of analytes from the sorbent with acetonitrile, the obtained solution was put under the DLLME procedure, so that the extra preconcentration factors could be achieved. The parameters influencing the extraction efficiency such as breakthrough volume, type and volume of the elution solvent (disperser solvent) and extracting solvent, as well as the salt addition, were studied and optimized. The calibration curves were linear in the range of 0.5-500 μg/L and the limit of detection for all analytes was found to be 0.2 μg/L. The relative standard deviations (for 0.75 μg/L of MNTs) without internal standard varied from 2.0 to 6.4% (n=5). The relative recoveries of the well, river and sea water samples, spiked at the concentration level of 0.75 μg/L of the analytes, were in the range of 85-118%.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Plasma catecholamines provide a reliable biomarker of sympathetic activity. The low circulating concentrations of catecholamines and analytical interferences require tedious sample preparation and long chromatographic runs to ensure their accurate quantification by HPLC with electrochemical detection. Published or commercially available methods relying on solid phase extraction technology lack sensitivity or require derivatization of catecholamine by hazardous reagents prior to tandem mass spectrometry (MS) analysis. Here, we manufactured a novel 96-well microplate device specifically designed to extract plasma catecholamines prior to their quantification by a new and highly sensitive ultraperformance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method. Processing time, which included sample purification on activated aluminum oxide and elution, is less than 1 h per 96-well microplate. The UPLC-MS/MS analysis run time is 2.0 min per sample. This UPLC-MS/MS method does not require a derivatization step, reduces the turnaround time by 10-fold compared to conventional methods used for routine application, and allows catecholamine quantification in reduced plasma sample volumes (50-250 μL, e.g., from children and mice).

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Reversed phase liquid chromatography (RPLC) coupled to mass spectrometry (MS) is the gold standard technique in bioanalysis. However, hydrophilic interaction chromatography (HILIC) could represent a viable alternative to RPLC for the analysis of polar and/or ionizable compounds, as it often provides higher MS sensitivity and alternative selectivity. Nevertheless, this technique can be also prone to matrix effects (ME). ME are one of the major issues in quantitative LC-MS bioanalysis. To ensure acceptable method performance (i.e., trueness and precision), a careful evaluation and minimization of ME is required. In the present study, the incidence of ME in HILIC-MS/MS and RPLC-MS/MS was compared for plasma and urine samples using two representative sets of 38 pharmaceutical compounds and 40 doping agents, respectively. The optimal generic chromatographic conditions in terms of selectivity with respect to interfering compounds were established in both chromatographic modes by testing three different stationary phases in each mode with different mobile phase pH. A second step involved the assessment of ME in RPLC and HILIC under the best generic conditions, using the post-extraction addition method. Biological samples were prepared using two different sample pre-treatments, i.e., a non-selective sample clean-up procedure (protein precipitation and simple dilution for plasma and urine samples, respectively) and a selective sample preparation, i.e., solid phase extraction for both matrices. The non-selective pretreatments led to significantly less ME in RPLC vs. HILIC conditions regardless of the matrix. On the contrary, HILIC appeared as a valuable alternative to RPLC for plasma and urine samples treated by a selective sample preparation. Indeed, in the case of selective sample preparation, the compounds influenced by ME were different in HILIC and RPLC, and lower and similar ME occurrence was generally observed in RPLC vs. HILIC for urine and plasma samples, respectively. The complementary of both chromatographic modes was also demonstrated, as ME was observed only scarcely for urine and plasma samples when selecting the most appropriate chromatographic mode.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Captan and folpet are fungicides largely used in agriculture. They have similar chemical structures, except that folpet has an aromatic ring unlike captan. Their half-lives in blood are very short, given that they are readily broken down to tetrahydrophthalimide (THPI) and phthalimide (PI), respectively. Few authors measured these biomarkers in plasma or urine, and analysis was conducted either by gas chromatography coupled to mass spectrometry or liquid chromatography with UV detection. The objective of this study was thus to develop simple, sensitive and specific liquid chromatography-atmospheric pressure chemical ionization-tandem mass spectrometry (LC/APCI-MS/MS) methods to quantify both THPI and PI in human plasma and urine. Briefly, deuterated THPI was added as an internal standard and purification was performed by solid-phase extraction followed by LC/APCI-MS/MS analysis in negative ion mode for both compounds. Validation of the methods was conducted using spiked blank plasma and urine samples at concentrations ranging from 1 to 250 μg/L and 1 to 50 μg/L, respectively, along with samples of volunteers and workers exposed to captan or folpet. The methods showed a good linearity (R (2) > 0.99), recovery (on average 90% for THPI and 75% for PI), intra- and inter-day precision (RSD, <15%) and accuracy (<20%), and stability. The limit of detection was 0.58 μg/L in urine and 1.47 μg/L in plasma for THPI and 1.14 and 2.17 μg/L, respectively, for PI. The described methods proved to be accurate and suitable to determine the toxicokinetics of both metabolites in human plasma and urine.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Therapeutic drug monitoring (TDM) may contribute to optimizing the efficacy and safety of antifungal therapy because of the large variability in drug pharmacokinetics. Rapid, sensitive, and selective laboratory methods are needed for efficient TDM. Quantification of several antifungals in a single analytical run may best fulfill these requirements. We therefore developed a multiplex ultra-performance liquid chromatography-tandem mass spectrometry (UPLC-MS/MS) method requiring 100 μl of plasma for simultaneous quantification within 7 min of fluconazole, itraconazole, hydroxyitraconazole, posaconazole, voriconazole, voriconazole-N-oxide, caspofungin, and anidulafungin. Protein precipitation with acetonitrile was used in a single extraction procedure for eight analytes. After reverse-phase chromatographic separation, antifungals were quantified by electrospray ionization-triple-quadrupole mass spectrometry by selected reaction monitoring detection using the positive mode. Deuterated isotopic compounds of azole antifungals were used as internal standards. The method was validated based on FDA recommendations, including assessment of extraction yields, matrix effect variability (<9.2%), and analytical recovery (80.1 to 107%). The method is sensitive (lower limits of azole quantification, 0.01 to 0.1 μg/ml; those of echinocandin quantification, 0.06 to 0.1 μg/ml), accurate (intra- and interassay biases of -9.9 to +5% and -4.0 to +8.8%, respectively), and precise (intra- and interassay coefficients of variation of 1.2 to 11.1% and 1.2 to 8.9%, respectively) over clinical concentration ranges (upper limits of quantification, 5 to 50 μg/ml). Thus, we developed a simple, rapid, and robust multiplex UPLC-MS/MS assay for simultaneous quantification of plasma concentrations of six antifungals and two metabolites. This offers, by optimized and cost-effective lab resource utilization, an efficient tool for daily routine TDM aimed at maximizing the real-time efficacy and safety of different recommended single-drug antifungal regimens and combination salvage therapies, as well as a tool for clinical research.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Different interferometric techniques were developed last decade to obtain full field, quantitative, and absolute phase imaging, such as phase-shifting, Fourier phase microscopy, Hilbert phase microscopy or digital holographic microscopy (DHM). Although, these techniques are very similar, DHM combines several advantages. In contrast, to phase shifting, DHM is indeed capable of single-shot hologram recording allowing a real-time absolute phase imaging. On the other hand, unlike to Fourier phase or Hilbert phase microscopy, DHM does not require to record in focus images of the specimen on the digital detector (CCD or CMOS camera), because a numerical focalization adjustment can be performed by a numerical wavefront propagation. Consequently, the depth of view of high NA microscope objectives is numerically extended. For example, two different biological cells, floating at different depths in a liquid, can be focalized numerically from the same digital hologram. Moreover, the numerical propagation associated to digital optics and automatic fitting procedures, permits vibrations insensitive full- field phase imaging and the complete compensation for a priori any image distortion or/and phase aberrations introduced for example by imperfections of holders or perfusion chamber. Examples of real-time full-field phase images of biological cells have been demonstrated. ©2008 COPYRIGHT SPIE

Relevância:

30.00% 30.00%

Publicador:

Resumo:

For doping control, analyses of samples are generally achieved in two steps: a rapid screening and, in the case of a positive result, a confirmatory analysis. A two-step methodology based on ultra-high-pressure liquid chromatography coupled to a quadrupole time-of-flight mass spectrometry (UHPLC-QTOF-MS) was developed to screen and confirm 103 doping agents from various classes (e.g., beta-blockers, stimulants, diuretics, and narcotics). The screening method was presented in a previous article as part I (i.e., Fast analysis of doping agents in urine by ultra-high-pressure liquid chromatography-quadrupole time-of-flight mass spectrometry. Part I: screening analysis). For the confirmatory method, basic, neutral and acidic compounds were extracted by a dedicated solid-phase extraction (SPE) in a 96-well plate format and detected by MS in the tandem mode to obtain precursor and characteristic product ions. The mass accuracy and the elemental composition of precursor and product ions were used for compound identification. After validation including matrix effect determination, the method was considered reliable to confirm suspect results without ambiguity according to the positivity criteria established by the World Anti-Doping Agency (WADA). Moreover, an isocratic method was developed to separate ephedrine from its isomer pseudoephedrine and cathine from phenylpropanolamine in a single run, what allowed their direct quantification in urine.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

RATIONALE: The aim of the work was to develop and validate a method for the quantification of vitamin D metabolites in serum using ultra-high-pressure liquid chromatography coupled to mass spectrometry (LC/MS), and to validate a high-resolution mass spectrometry (LC/HRMS) approach against a tandem mass spectrometry (LC/MS/MS) approach using a large clinical sample set. METHODS: A fast, accurate and reliable method for the quantification of the vitamin D metabolites, 25-hydroxyvitamin D2 (25OH-D2) and 25-hydroxyvitamin D3 (25OH-D3), in human serum was developed and validated. The C3 epimer of 25OH-D3 (3-epi-25OH-D3) was also separated from 25OH-D3. The samples were rapidly prepared via a protein precipitation step followed by solid-phase extraction (SPE) using an HLB μelution plate. Quantification was performed using both LC/MS/MS and LC/HRMS systems. RESULTS: Recovery, matrix effect, inter- and intra-day reproducibility were assessed. Lower limits of quantification (LLOQs) were determined for both 25OH-D2 and 25OH-D3 for the LC/MS/MS approach (6.2 and 3.4 µg/L, respectively) and the LC/HRMS approach (2.1 and 1.7 µg/L, respectively). A Passing & Bablok fit was determined between both approaches for 25OH-D3 on 662 clinical samples (1.11 + 1.06x). It was also shown that results can be affected by the inclusion of the isomer 3-epi-25OH-D3. CONCLUSIONS: Quantification of the relevant vitamin D metabolites was successfully developed and validated here. It was shown that LC/HRMS is an accurate, powerful and easy to use approach for quantification within clinical laboratories. Finally, the results here suggest that it is important to separate 3-epi-25OH-D3 from 25OH-D3. Copyright © 2012 John Wiley & Sons, Ltd.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Voriconazole (VRC) is a broad-spectrum antifungal triazole with nonlinear pharmacokinetics. The utility of measurement of voriconazole blood levels for optimizing therapy is a matter of debate. Available high-performance liquid chromatography (HPLC) and bioassay methods are technically complex, time-consuming, or have a narrow analytical range. Objectives of the present study were to develop new, simple analytical methods and to assess variability of voriconazole blood levels in patients with invasive mycoses. Acetonitrile precipitation, reverse-phase separation, and UV detection were used for HPLC. A voriconazole-hypersusceptible Candida albicans mutant lacking multidrug efflux transporters (cdr1Delta/cdr1Delta, cdr2Delta/cdr2Delta, flu1Delta/flu1Delta, and mdr1Delta/mdr1Delta) and calcineurin subunit A (cnaDelta/cnaDelta) was used for bioassay. Mean intra-/interrun accuracies over the VRC concentration range from 0.25 to 16 mg/liter were 93.7% +/- 5.0%/96.5% +/- 2.4% (HPLC) and 94.9% +/- 6.1%/94.7% +/- 3.3% (bioassay). Mean intra-/interrun coefficients of variation were 5.2% +/- 1.5%/5.4% +/- 0.9% and 6.5% +/- 2.5%/4.0% +/- 1.6% for HPLC and bioassay, respectively. The coefficient of concordance between HPLC and bioassay was 0.96. Sequential measurements in 10 patients with invasive mycoses showed important inter- and intraindividual variations of estimated voriconazole area under the concentration-time curve (AUC): median, 43.9 mg x h/liter (range, 12.9 to 71.1) on the first and 27.4 mg x h/liter (range, 2.9 to 93.1) on the last day of therapy. During therapy, AUC decreased in five patients, increased in three, and remained unchanged in two. A toxic encephalopathy probably related to the increase of the VRC AUC (from 71.1 to 93.1 mg x h/liter) was observed. The VRC AUC decreased (from 12.9 to 2.9 mg x h/liter) in a patient with persistent signs of invasive aspergillosis. These preliminary observations suggest that voriconazole over- or underexposure resulting from variability of blood levels might have clinical implications. Simple HPLC and bioassay methods offer new tools for monitoring voriconazole therapy.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The anti-diuretic neurohypophysial hormone Vasopressin (Vp) and its synthetic analogue Desmopressin (Dp, 1-desamino-vasopressin) have received considerable attention from doping control authorities due to their impact on physiological blood parameters. Accordingly, the illicit use of Desmopressin in elite sport is sanctioned by the World Anti-Doping Agency (WADA) and the drug is classified as masking agent. Vp and Dp are small (8-9 amino acids) peptides administered orally as well as intranasally. Within the present study a method to determine Dp and Vp in urinary doping control samples by means of liquid chromatography coupled to quadrupole high resolution time-of-flight mass spectrometry was developed. After addition of Lys-Vasopressin as internal standard and efficient sample clean up with a mixed mode solid phase extraction (weak cation exchange), the samples were directly injected into the LC-MS system. The method was validated considering the parameters specificity, linearity, recovery (80-100%), accuracy, robustness, limit of detection/quantification (20/50 pg mL(-1)), precision (inter/intra-day<10%), ion suppression and stability. The analysis of administration study urine samples collected after a single intranasal or oral application of Dp yielded in detection windows for the unchanged target analyte for up to 20 h at concentrations between 50 and 600 pg mL(-1). Endogenous Vp was detected in concentrations of approximately 20-200 pg mL(-1) in spontaneous urine samples obtained from healthy volunteers. The general requirements of the developed method provide the characteristics for an easy transfer to other anti-doping laboratories and support closing another potential gap for cheating athletes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

There is increasing evidence that the clinical efficacy of tamoxifen, the first and most widely used targeted therapy for estrogen-sensitive breast cancer, depends on the formation of the active metabolites 4-hydroxy-tamoxifen and 4-hydroxy-N-desmethyl-tamoxifen (endoxifen). Large inter-individual variability in endoxifen plasma concentrations has been observed and related both to genetic and environmental (i.e. drug-induced) factors altering CYP450s metabolizing enzymes activity. In this context, we have developed an ultra performance liquid chromatography-tandem mass spectrometry method (UPLC-MS/MS) requiring 100 μL of plasma for the quantification of tamoxifen and three of its major metabolites in breast cancer patients. Plasma is purified by a combination of protein precipitation, evaporation at room temperature under nitrogen, and reconstitution in methanol/20 mM ammonium formate 1:1 (v/v), adjusted to pH 2.9 with formic acid. Reverse-phase chromatographic separation of tamoxifen, N-desmethyl-tamoxifen, 4-hydroxy-tamoxifen and 4-hydroxy-N-desmethyl-tamoxifen is performed within 13 min using elution with a gradient of 10 mM ammonium formate and acetonitrile, both containing 0.1% formic acid. Analytes quantification, using matrix-matched calibration samples spiked with their respective deuterated internal standards, is performed by electrospray ionization-triple quadrupole mass spectrometry using selected reaction monitoring detection in the positive mode. The method was validated according to FDA recommendations, including assessment of relative matrix effects variability, as well as tamoxifen and metabolites short-term stability in plasma and whole blood. The method is precise (inter-day CV%: 2.5-7.8%), accurate (-1.4 to +5.8%) and sensitive (lower limits of quantification comprised between 0.4 and 2.0 ng/mL). Application of this method to patients' samples has made possible the identification of two further metabolites, 4'-hydroxy-tamoxifen and 4'-hydroxy-N-desmethyl-tamoxifen, described for the first time in breast cancer patients. This UPLC-MS/MS assay is currently applied for monitoring plasma levels of tamoxifen and its metabolites in breast cancer patients within the frame of a clinical trial aiming to assess the impact of dose increase on tamoxifen and endoxifen exposure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Oseltamivir phosphate (OP), the prodrug of oseltamivir carboxylate (OC; active metabolite), is marketed since 10 years for the treatment of seasonal influenza flu. It has recently received renewed attention because of the threat of avian flu H5N1 in 2006-7 and the 2009-10 A/H1N1 pandemic. However, relatively few studies have been published on OP and OC clinical pharmacokinetics. The disposition of OC and the dosage adaptation of OP in specific populations, such as young children or patients undergoing extrarenal epuration, have also received poor attention. An analytical method was thus developed to assess OP and OC plasma concentrations in patients receiving OP and presenting with comorbidities or requiring intensive care. Methods: A high performance liquid chromatography coupled to tandem mass spectrometry method (HPLC-MS/MS) requiring 100-µL aliquot of plasma for quantification within 6 min of OP and OC was developed. A combination of protein precipitation with acetonitrile, followed by dilution of supernant in suitable buffered solvent was used as an extraction procedure. After reverse phase chromatographic separation, quantification was performed by electro-spray ionization-triple quadrupole mass spectrometry. Deuterated isotopic compounds of OP and OC were used as internal standards. Results: The method is sensitive (lower limit of quantification: 5 ng/mL for OP and OC), accurate (intra-/inter-assay bias for OP and OC: 8.5%/5.5% and 3.7/0.7%, respectively) and precise (intra-/inter-assay CV%: 5.2%/6.5% and 6.3%/9.2%, respectively) over the clinically relevant concentration range (upper limits of quantification 5000 ng/mL). Of importance, OP, as in other previous reports, was found not to be stable ex vivo in plasma on standard anticoagulants (i.e. EDTA, heparin or citrate). This poor stability of OP has been prevented by collecting blood samples on commercial fluoride/oxalate tubes. Conclusions: This new simple, rapid and robust HPLC-MS/MS assay for quantification of OP and OC plasma concentrations offers an efficient tool for concentration monitoring of OC. Its exposure can probably be controlled with sufficient accuracy by thorough dosage adjustment according to patient characteristics (e.g. renal clearance). The usefulness of systematic therapeutic drug monitoring in patients appears therefore questionable. However, pharmacokinetic studies are still needed to extend knowledge to particular subgroups of patients or dosage regimens.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The urinary steroid profile is constituted by anabolic androgenic steroids, including testosterone and its relatives, that are extensively metabolized into phase II sulfated or glucuronidated steroids. The use of liquid chromatography coupled to mass spectrometry (LC-MS) is an issue for the direct analysis of conjugated steroids, which can be used as urinary markers of exogenous steroid administration in doping analysis, without hydrolysis of the conjugated moiety. In this study, a sensitive and selective ultra high-pressure liquid chromatography coupled to quadrupole time-of-flight mass spectrometer (UHPLC-QTOF-MS) method was developed to quantify major urinary metabolites simultaneously after testosterone intake. The sample preparation of the urine (1 mL) was performed by solid-phase extraction on Oasis HLB sorbent using a 96-well plate format. The conjugated steroids were analyzed by UHPLC-QTOF-MS(E) with a single-gradient elution of 36 min (including re-equilibration time) in the negative electrospray ionization mode. MS(E) analysis involved parallel alternating acquisitions of both low- and high-collision energy functions. The method was validated and applied to samples collected from a clinical study performed with a group of healthy human volunteers who had taken testosterone, which were compared with samples from a placebo group. Quantitative results were also compared to GC-MS and LC-MS/MS measurements, and the correlations between data were found appropriate. The acquisition of full mass spectra over the entire mass range with QTOF mass analyzers gives promise of the opportunity to extend the steroid profile to a higher number of conjugated steroids.