21 resultados para Wire-on-tube condenser


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To examine the efficacy and safety of Baerveldt shunt (BS) implantation compared to combined phacoemulsification and Baerveldt shunt implantation (PBS). This study was designed to detect a difference in IOP reduction of 20% (~4mmHg) between groups with 90% power. Methods: Sixty patients with medically uncontrolled glaucoma, prospectively underwent either or BS implantation with phacoemulsification (Group PBS; n=30) or BS implantation alone (group BS; n=30, pseudophakic eyes only). Groups were matched for age, glaucoma subtype and length of follow-up. Pre and post-operative measures recorded included patient demographics, visual acuity, IOP, number of glaucoma medications (GMs) and all complications. Success was defined as IOP≤21mmHg and 20% reduction in IOP from baseline with or without GMs. Results: Age of PBS and BS groups was 61 vs 62 years respectively (p=0.72*). There were no significant differences in preoperative baseline characteristics: PBS vs PB, mean IOP =25.5mmHg (standard deviation (SD); ±10.3mmHg) vs 26.1mmHg (SD ±10.6mmHg), p=0.81*; mean GMs=3.0 (SD ±1.1) vs 3.1 (SD ±1.0), p=0.83*; mean VA=0.3 vs 0.3, p=0.89*. At year one there were no significant differences observed between groups in post-operative IOP, GMs or VA, mean IOP =14.1mmHg (SD ±5.4mmHg) vs 11.5 mmHg (SD ±4.2mmHg), p=0.12*; mean GMs=1.6 (SD ±1.4) vs 1.1 (SD ±1.1), p=0.23*; mean VA=0.5 vs 0.4, p=0.46*. Complication rates were similar between the two groups (7% vs 14%). Success rate was lower in eyes with PBS (71%) than with BS (88%), however this did not reach statistical significance (p=0.95, log-rank test). * two-sample t-test Conclusions: There were no significant differences at year one in success or complication rates between PBS and BS groups suggesting that simultaneous phacoemulsification does not have a marked (difference of >4mmHg) effect on tube function. IOP reduction and success were less in the PBS group, a larger sample (n=120) would be required to investigate if there is a 10% difference in IOP reduction between groups, however it is unclear if this would be a clinically significant difference to justify separate surgeries.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE: This study was designed to analyze the duration of chest tube drainage on pain intensity and distribution after cardiac surgery. METHODS: Two groups of 80 cardiac surgery adult patients, operated on in two different hospitals, by the same group of cardiac surgeons, and with similar postoperative strategies, were compared. However, in one hospital (long drainage group), a conservative policy was adopted with the removal the chest tubes by postoperative day (POD) 2 or 3, while in the second hospital (short drainage group), all the drains were usually removed on POD 1. RESULTS: There was a trend toward less pain in the short drainage group, with a statistically significant difference on POD 2 (P=0.047). There were less patients without pain on POD 3 in the long drainage group (P=0. 01). The areas corresponding to the tract of the pleural tube, namely the epigastric area, the left basis of the thorax, and the left shoulder were more often involved in the long drainage group. There were three pneumonias in each group and no patient required repeated drainage. CONCLUSIONS: A policy of early chest drain ablation limits pain sensation and simplifies nursing care, without increasing the need for repeated pleural puncture. Therefore, a policy of short drainage after cardiac surgery should be recommended.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

OBJECTIVE: To 'map' the current (2004) state of prenatal screening in Europe. DESIGN: (i) Survey of country policies and (ii) analysis of data from EUROCAT (European Surveillance of Congenital Anomalies) population-based congenital anomaly registers. SETTING: Europe. POPULATION: Survey of prenatal screening policies in 18 countries and 1.13 million births in 12 countries in 2002-04. METHODS: (i) Questionnaire on national screening policies and termination of pregnancy for fetal anomaly (TOPFA) laws in 2004. (ii) Analysis of data on prenatal detection and termination for Down's syndrome and neural tube defects (NTDs) using the EUROCAT database. MAIN OUTCOME MEASURES: Existence of national prenatal screening policies, legal gestation limit for TOPFA, prenatal detection and termination rates for Down's syndrome and NTD. RESULTS: Ten of the 18 countries had a national country-wide policy for Down's syndrome screening and 14/18 for structural anomaly scanning. Sixty-eight percent of Down's syndrome cases (range 0-95%) were detected prenatally, of which 88% resulted in termination of pregnancy. Eighty-eight percent (range 25-94%) of cases of NTD were prenatally detected, of which 88% resulted in termination. Countries with a first-trimester screening policy had the highest proportion of prenatally diagnosed Down's syndrome cases. Countries with no official national Down's syndrome screening or structural anomaly scan policy had the lowest proportion of prenatally diagnosed Down's syndrome and NTD cases. Six of the 18 countries had a legal gestational age limit for TOPFA, and in two countries, termination of pregnancy was illegal at any gestation. CONCLUSIONS: There are large differences in screening policies between countries in Europe. These, as well as organisational and cultural factors, are associated with wide country variation in prenatal detection rates for Down's syndrome and NTD.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Experimental evidence indicates a role of the N-methyl-D-aspartate receptor in the pathogenesis of brain injury occurring during cardiac surgery with cardiopulmonary bypass (CPB). Dextromethorphan is a noncompetitive antagonist of this receptor with a favorable safety profile. Thirteen children age 3-36 months undergoing cardiac surgery with expected CPB of 60 minutes or more were randomly assigned to treatment with dextromethorphan (36-38 mg/kg/day) or placebo administered by naso-gastric tube. Dextromethorphan was absorbed well and reached putative therapeutic levels in blood and cerebrospinal fluid. Adverse effects were not observed. Mild hemiparesis developed after operation in one child of each group, and severe encephalopathy in one of the placebo group. Sharp waves were recorded in postoperative continuous electroencephalography in all placebo (n = 7) but only in 2/6 dextromethorphan treated children (p = 0.02). Pre- and postoperative cranial magnetic resonance imaging (MRI) revealed less pronounced ventricular enlargement in the dextromethorphan group (not significant). An increase of periventricular white matter lesions was visible in two placebo-treated children only. No elevations of cerebrospinal fluid enzymes were observed in either group. Although children with dextromethorphan showed less abnormalities in electroencephalography and MRI, dissimilarities of the treatment groups by chance diminished conclusions to possible protective effects of dextromethorphan at this time.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIMS/HYPOTHESIS: Excess glucose transport to embryos during diabetic pregnancy causes congenital malformations. The early postimplantation embryo expresses the gene encoding the high-Km GLUT2 (also known as SLC2A2) glucose transporter. The hypothesis tested here is that high-Km glucose transport by GLUT2 causes malformations resulting from maternal hyperglycaemia during diabetic pregnancy. MATERIALS AND METHODS: Glut2 mRNA was assayed by RT-PCR. The Km of embryo glucose transport was determined by measuring 0.5-20 mmol/l 2-deoxy[3H]glucose transport. To test whether the GLUT2 transporter is required for neural tube defects resulting from maternal hyperglycaemia, Glut2+/- mice were crossed and transient hyperglycaemia was induced by glucose injection on day 7.5 of pregnancy. Embryos were recovered on day 10.5, and the incidence of neural tube defects in wild-type, Glut2+/- and Glut2-/- embryos was scored. RESULTS: Early postimplantation embryos expressed Glut2, and expression was unaffected by maternal diabetes. Moreover, glucose transport by these embryos showed Michaelis-Menten kinetics of 16.19 mmol/l, consistent with transport mediated by GLUT2. In pregnancies made hyperglycaemic on day 7.5, neural tube defects were significantly increased in wild-type embryos, but Glut2+/- embryos were partially protected from neural tube defects, and Glut2-/- embryos were completely protected from these defects. The frequency of occurrence of wild-type, Glut2+/- and Glut2-/- embryos suggests that the presence of Glut2 alleles confers a survival advantage in embryos before day 10.5. CONCLUSIONS/INTERPRETATIONS: High-Km glucose transport by the GLUT2 glucose transporter during organogenesis is responsible for the embryopathic effects of maternal diabetes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Near infrared spectroscopy (NIRS) is a non-invasive method of estimating the haemoglobin concentration changes in certain tissues. It is frequently used to monitor oxygenation of the brain in neonates. At present it is not clear whether near infrared spectroscopy of other organs (e.g. the liver as a corresponding site in the splanchnic region, which reacts very sensitively to haemodynamic instability) provides reliable values on their tissue oxygenation. The aim of the study was to test near infrared spectroscopy by measuring known physiologic changes in tissue oxygenation of the liver in newborn infants during and after feeding via a naso-gastric tube. The test-retest variability of such measurements was also determined. On 28 occasions in 25 infants we measured the tissue oxygenation index (TOI) of the liver and the brain continuously before, during and 30 minutes after feeding via a gastric tube. Simultaneously we measured arterial oxygen saturation (SaO2), heart rate (HR) and mean arterial blood pressure (MAP). In 10 other newborn infants we performed a test-retest analysis of the liver tissue oxygenation index to estimate the variability in repeated intra-individual measurements. The tissue oxygenation index of the liver increased significantly from 56.7 +/- 7.5% before to 60.3 +/- 5.6% after feeding (p < 0.005), and remained unchanged for the next 30 minutes. The tissue oxygenation index of the brain (62.1 +/- 9.7%), SaO2 (94.4 +/- 7.1%), heart rate (145 +/- 17.3 min-1) and mean arterial blood pressure (52.8 +/- 10.2 mm Hg) did not change significantly. The test-retest variability for intra-individual measurements was 2.7 +/- 2.1%. After bolus feeding the tissue oxygenation index of the liver increased as expected. This indicates that near infrared spectroscopy is suitable for monitoring changes in tissue oxygenation of the liver in newborn infants.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effect of copper (Cu) filtration on image quality and dose in different digital X-ray systems was investigated. Two computed radiography systems and one digital radiography detector were used. Three different polymethylmethacrylate blocks simulated the pediatric body. The effect of Cu filters of 0.1, 0.2, and 0.3 mm thickness on the entrance surface dose (ESD) and the corresponding effective doses (EDs) were measured at tube voltages of 60, 66, and 73 kV. Image quality was evaluated in a contrast-detail phantom with an automated analyzer software. Cu filters of 0.1, 0.2, and 0.3 mm thickness decreased the ESD by 25-32%, 32-39%, and 40-44%, respectively, the ranges depending on the respective tube voltages. There was no consistent decline in image quality due to increasing Cu filtration. The estimated ED of anterior-posterior (AP) chest projections was reduced by up to 23%. No relevant reduction in the ED was noted in AP radiographs of the abdomen and pelvis or in posterior-anterior radiographs of the chest. Cu filtration reduces the ESD, but generally does not reduce the effective dose. Cu filters can help protect radiosensitive superficial organs, such as the mammary glands in AP chest projections.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVE: To assess the change in non-compliant items in prescription orders following the implementation of a computerized physician order entry (CPOE) system named PreDiMed. SETTING: The department of internal medicine (39 and 38 beds) in two regional hospitals in Canton Vaud, Switzerland. METHOD: The prescription lines in 100 pre- and 100 post-implementation patients' files were classified according to three modes of administration (medicines for oral or other non-parenteral uses; medicines administered parenterally or via nasogastric tube; pro re nata (PRN), as needed) and analyzed for a number of relevant variables constitutive of medical prescriptions. MAIN OUTCOME MEASURE: The monitored variables depended on the pharmaceutical category and included mainly name of medicine, pharmaceutical form, posology and route of administration, diluting solution, flow rate and identification of prescriber. RESULTS: In 2,099 prescription lines, the total number of non-compliant items was 2,265 before CPOE implementation, or 1.079 non-compliant items per line. Two-thirds of these were due to missing information, and the remaining third to incomplete information. In 2,074 prescription lines post-CPOE implementation, the number of non-compliant items had decreased to 221, or 0.107 non-compliant item per line, a dramatic 10-fold decrease (chi(2) = 4615; P < 10(-6)). Limitations of the computerized system were the risk for erroneous items in some non-prefilled fields and ambiguity due to a field with doses shown on commercial products. CONCLUSION: The deployment of PreDiMed in two departments of internal medicine has led to a major improvement in formal aspects of physicians' prescriptions. Some limitations of the first version of PreDiMed were unveiled and are being corrected.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: To study the filtering site using ultrasound biomicroscopy. (UBM) after posterior deep sclerectomy with Ex-PRESS? X-50 implant in patients undergoing filtering surgery.¦Methods: Twenty-six patients that participated in this prospective, non comparative study underwent a posterior deep sclerectomy and an Ex- PRESS? X-50 tube implantation. Clinical outcome factors recorded include: intraocular pressure, number of antiglaucoma medications, best corrected visual acuity (BCVA), frequency and types of complications. Six months postoperatively, an ultrasound biomicroscopy examination was performed.¦Results: Mean follow up was 12.0±3.4 months. Mean IOP decreased from 21 ±5.7 mmHg to 12.4±3 mmHg. At last follow-up examination, 65% of eyes had a complete success and 30% a qualified success. The mean number of antiglaucoma medications decreased from 2.5±1.2 preoperatively to 0.7±1 at the last follow-up postoperatively. BCVA was not changed. 27 complications were observed. On the UBM images, the mean intrascleral space volume was 0.25±0.27 mm3 and no relationship was found between volume and intraocular pressure reduction. We noted in 5/26 (19%) eyes a suprachoroïdal hypoechoic. Low-reflective blebs (L-type) were the most common: 15/26 (58%). No correlation between UBM findings and surgical success was evident.¦Conclusions: Deep sclerectomy with Ex-PRESS? X-50 tube implantation seems an efficient glaucoma surgery. It allows satisfactory IOP reduction with a low number of post operative complications. The advantages of deep sclerectomy with collagen implant are maintained with this modified technique. In both, the same reflective types of filtering blebs are present (high, low, encapsulated and flat). The UBM underlines the three mechanisms of aqueous humor resorption previously identified but no correlation with surgical success can be proved.¦-¦Ce travail de thèse est une analyse par ultrasonographic biomicroscopique (UBM) du site de filtration après sclérectomie profonde postérieure modifiée avec implantation d'un tube Ex- PRESS? X-50.¦Vingt six patients atteints d'un glaucome à angle ouvert, ont participé à cette étude prospective et non-comparative. Le critère d'inclusion est un glaucome à angle ouvert non contrôlé malgré un traitement topique maximal.¦Différents types de chirurgie filtrante sont effectués dans la chirurgie du glaucome dont la trabéculectomie et la sclérectomie profonde.¦L'intervention chirurgicale pratiquée dans cette étude consiste en l'implantation d'un tube Ex-PRESS? X-50 de format défini (3 mm de longueur et 50 μπι de diamètre interne) dans la chambre antérieure,au niveau du trabeculum, sous un volet scléral, ce qui permet le drainage de l'humeur aqueuse vers les espaces sous-conjonctivaux, avec diminution de la pression intraoculaire.¦Cette technique implique uniquement une dissection d'un volet scléral superficiel , sans volet scléral profond comme d'une sclérectomie profonde classique.¦Les modes de fonctionnement de cette sclérectomie profonde modifiée sont explorés par UBM, qui donne des images à haute résolution, semblables à des coupes anatomiques. Le volume de l'espace intrascléral créé artificiellement peut en effet être mesuré et mis en corrélation avec la pression intraoculaire et donc avec le taux de succès. Les différents types d'échogénécité de la bulle de filtration sous-conjonctivale provoquée par la dérivation de l'humeur aqueuse sont également observés. La présence éventuelle d'une filtration supplémentaire au niveau choroïdien est aussi détectée.¦De février 2007 à juin 2008, nous avons suivi chez les vingt six yeux des vingt six patients le volume intrascléral, la filtration sous-conjonctivale et la filtration choroïdienne le cas échéant, de même que l'acuité visuelle, la pression intraoculaire, le nombre de traitement antihypertenseur topique et les complications.¦Les résultats démontrent une réduction de 41 % par rapport à la pression intraoculaire préopératoire, ce qui est statistiquement significatif (p<0.0005). En ce qui concerne l'acuité visuelle, les valeurs demeurent stables. Par ailleurs, le nombre de médicaments antiglaucomateux diminue de façon significative de 2.5 ± 1.2 en préopératoire à 0.7 ± 1.0 au dernier examen (p<0.0005). Le volume de l'espace intrascléral, apparaissant toujours en échographie d'aspect fusiforme, n'est pas corrélé de façon significative avec un meilleur succès chirurgical bien que l'on aperçoive une tendance à une corrélation entre un plus grand volume et une pression intraoculaire plus basse.¦La classification la bulle de filtration se fait selon les 4 catégories de bulle de filtration décrites dans la littérature. La répartition révèle une majorité de type L soit hypoéchogène: 15/26 (58%) et une proportion identique, soit, 4/26 (16%), de bulles hyperéchogènes (type H) et encapsulées (type E); les bulles de filtration plates et hyperéchogènes (type F) sont les moins nombreuses 3/26 (11 %).¦La ligne hyporéflective visible dans 19 % des cas entre la sclère et la choroïde représentant potentiellement un drainage suprachoroïdien, n'est pas associée statistiquement à une meilleure filtration et une pression intraoculaire plus basse mais demeure une troisième voie de filtration, en plus de la filtration sous-conjonctivale et intrasclérale.¦En conclusion, cette technique différente, offrant une plus grande sécurité et des résultats satisfaisants sur l'abaissement de la pression intraoculaire, peut être, dans certains cas, une alternative à la sclérectomie profonde classique ,dont elle partage les mécanismes de filtration objectivés par ultrasonographic biomicrioscopique.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A test kit based on living, lyophilized bacterial bioreporters emitting bioluminescence as a response to arsenite and arsenate was applied during a field campaign in six villages across Bangladesh. Bioreporter field measurements of arsenic in groundwater from tube wells were in satisfying agreement with the results of spectroscopic analyses of the same samples conducted in the lab. The practicability of the bioreporter test in terms of logistics and material requirements, suitability for high sample throughput, and waste disposal was much better than that of two commercial chemical test kits that were included as references. The campaigns furthermore demonstrated large local heterogeneity of arsenic in groundwater, underscoring the use of well switching as an effective remedy to avoid high arsenic exposure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Les muqueuses sont les membranes tapissant les cavités du corps, tel que le tube digestif, et sont en contact direct avec l'environnement extérieur. Ces surfaces subissent de nombreuses agressions pouvant être provoquées par des agents pathogènes (bactéries, toxines ou virus). Cela étant, les muqueuses sont munies de divers mécanismes de protection dont notamment deux protéines-clés permettant de neutraliser les agents pathogènes : les anticorps ou immunoglobulines sécrétoires A (SIgA) et M (SIgM). Ces anticorps sont, d'une part, fabriqués au niveau de la muqueuse sous forme d'IgA et IgM. Lorsqu'ils sont sécrétés dans l'intestin, ils se lient à une protéine appelée pièce sécrétoire et deviennent ainsi SIgA et SïgM. La présence de la pièce sécrétoire est essentielle pour que les anticorps puissent fonctionner au niveau de la muqueuse. D'autre part, ces anticorps sont également fabriqués dans d'autres parties du corps en général et se retrouvent dans le sang sous forme d'IgA et IgM Chez l'homme, des thérapies basées sur l'injection d'anticorps donnent de bons résultats depuis de nombreuses années notamment dans le traitement des infections. Bien qu'un certain nombre d'études ont montré le rôle protecteur des anticorps de type IgA et IgM, ceux-ci ne sont que rarement utilisés dans les thérapies actuelles. La principale raison de cette faible utilisation réside dans la production ou la purification des IgA/IgM ou SIgA/SIgM (la forme active au niveau des muqueuses) qui est difficile à réaliser à large échelle. Ainsi, le but de la thèse était (1) d'étudier la possibilité d'employer des IgA et des IgM provenant du sang humain pour générer des SIgA et SIgM et (2) de voir si ces anticorps reconstitués pouvaient neutraliser certains agents pathogènes au niveau des muqueuses. Tout d'abord, une analyse biochimique des IgA et des IgM issues du sang a été effectuée. Nous avons observé que ces anticorps avaient des caractéristiques similaires aux anticorps naturellement présents au niveau des muqueuses. De plus, nous avons confirmé que ces anticorps pouvaient être associés à une pièce sécrétoire produite en laboratoire pour ainsi donner des SIgA et SIgM reconstituées. Ensuite, la fonctionnalité des anticorps reconstitués a été testée grâce à un modèle de couche unique de cellules intestinales différenciées (monocouches) en laboratoire imitant la paroi de l'intestin. Ces monocouches ont été infectées par une bactérie pathogène, Shigella flexneri, responsable de la shigellose, une maladie qui provoque des diarrhées sanglantes chez l'homme. L'infection des monocouches par les bactéries seules ou combinées aux SIgA et SIgM reconstituées a été analysée. Nous avons observé que les dommages des cellules étaient moins importants lorsque les SIgA étaient présentes. Il apparaît que les SIgA neutralisent les bactéries en se fixant dessus, ce qui provoque leur agrégation, et diminuent l'inflammation des cellules. La protection s'est montrée encore plus efficace avec les SIgM. De plus, nous avons vu que les SIgA et SIgM pouvaient diminuer la sécrétion de facteurs nocifs produits par les bactéries. Utilisant le même modèle des monocouches, la fonctionnalité des IgA issues du sang humain a aussi été testée contre une toxine sécrétée par une bactérie appelée Clostridium diffìcile. Cette bactérie peut être présente naturellement dans l'intestin de personnes saines, cependant elle peut devenir pathogène dans certaines conditions et être à l'origine de diarrhées et d'inflammations de l'intestin via la sécrétion de toxines. Des préparations d'anticorps contenant une certaine proportion de SIgA reconstituées ont amené à une diminution des dommages et de l'inflammation des monocouches causés par la toxine. L'ensemble de ces résultats prometteurs, montrant que des SIgA et SIgM reconstituées peuvent protéger la paroi de l'intestin des infections bactériennes, nous conduisent à approfondir la recherche sur ces anticorps dans des modèles animaux. L'aboutissement de ce type de recherche permettrait de tester, par la suite, l'efficacité sur l'homme de traitements des infections des muqueuses par injection d'anticorps de type SIgA et SIgM reconstituées. Les muqueuses, telle que la muqueuse gastrointestinale, sont des surfaces constamment exposées à l'environnement et leur protection est garantie par une combinaison de barrières mécaniques, physicochimiques et immunologiques. Parmi les divers mécanismes de protection immunologiques, la réponse humorale spécifique joue un rôle prépondérant et est assurée par les immunoglobulines sécrétoires de type A (SIgA) et M (SIgM). Les thérapies basées sur l'administration d'IgG apportent d'importants bénéfices dans le domaine de la santé. Bien que des études sur les animaux aient montré que l'administration par voie muqueuse d'IgA polymérique (plgA) ou SIgA pouvaient protéger des infections, des IgA/SIgA n'ont été utilisées qu'occasionnellement dans les thérapies. De plus, des études précliniques et cliniques ont démontré que l'administration par voie systémique de préparations enrichies en IgM pouvait aussi protéger des infections. Cependant, l'administration par voie muqueuse d'IgM/SIgM purifiées n'a pas été examinée jusqu'à présent. La principale raison est que la purification ou là production des IgA/SIgA et IgM/SIgM est difficile à réaliser à large échelle. Le but de ce travail de thèse était d'examiner la possibilité d'associer des IgA et IgM polyclonals purifiées à partir du plasma humain avec une pièce sécrétoire recombinante humaine afin de générer des SIgA et SIgM reconstituées fonctionnelles. Tout d'abord, une analyse biochimique des IgA et IgM issues du plasma humain a été effectuée par buvardage de western et Chromatographie. Ces molécules avaient des caractéristiques biochimiques similaires à celles des immunoglobulines issues de la muqueuse. L'association entre plgA ou IgM issues du plasma humain et la pièce sécrétoire recombinante humaine a été confirmée, ainsi que la stoechiométrie 1:1 de l'association. Comme dans les conditions physiologiques, cette association permettait de retarder la dégradation des SIgA et SIgM reconstituées exposées à des protéases intestinales. Ensuite, la fonctionnalité et le mode d'action des IgA et IgM issues du plasma humain, ainsi que des SIgA et SIgM reconstituées, ont été explorés grâce à un modèle in vitro de monocouches de cellules intestinales épithéliales polarisées de type Caco-2, qui imite l'épithélium intestinal. Les monocouches ont été infectées par un pathogène entérique, Shigella flexneri, seul ou combiné aux immunoglobulines issues du plasma humain ou aux immunoglobulines sécrétoires reconstituées. Bien que les dommages des monocouches aient été retardés par les plgA et SIgA reconstituées, les IgM et SIgM reconstituées se sont montrées supérieures dans le maintien de l'intégrité des cellules. Une agrégation bactérienne et une diminution de l'inflammation des monocouches ont été observées avec les plgA et SIgA reconstituées. Ces effets étaient augmentés avec les IgM et SIgM reconstituées. De plus, il s'est révélé que les deux types d'immunoglobulines de type sécrétoire reconstituées agissaient directement sur la virulence des bactéries en réduisant leur sécrétion de facteurs de virulence. La fonctionnalité des IgA issues du plasma humain a aussi été testée contre la toxine A de Clostridium difficile grâce au même modèle de monocouches de cellules épithéliales. Nous avons démontré que des préparations enrichies en IgA provenant du plasma humain pouvaient diminuer les dommages et l'inflammation des monocouches induits par la toxine. L'ensemble de ces résultats démontrent que des IgA et IgM de type sécrétoire peuvent être générées à partir d'IgA et IgM issues du plasma humain en les associant à la pièce sécrétoire et que ces molécules protègent l'épithélium intestinal contre des bactéries pathogènes. Ces molécules pourraient dès lors être testées dans des modèles in vivo. Le but final serait de les utiliser chez l'homme à des fins d'immunisation passive dans le traitement de pathologies associées à la muqueuse telles que les infections. - Mucosal surfaces, such as gastrointestinal mucosa, are constantly exposed to the external environment and their protection is ensured by a combination of mechanical, physicochemical and immunological barriers. Among the various immunological defense mechanisms, specific humoral mucosal response plays a crucial role and is mediated by secretory immunoglobulins A (SIgA) and M (SIgM). Immunoglobulin therapy based on the administration of IgG molecules leads important health benefits. Even though animal studies have shown that mucosal application of polymeric IgA (plgA) or SIgA provided protection against infections, IgA/SIgA have been only used occasionally for therapeutic application. Moreover, preclinical and clinical studies have demonstrated that systemic administration of IgM-enriched preparations could also afford protection against infections. Nevertheless, mucosal application of purified IgM/SIgM has not been examined. The main reason is that the purification or production of IgA/SIgA and IgM/SIgM at large scale is difficult to achieve. The aim of this PhD project was to examine the possibility to associate polyclonal human plasma-derived IgA and IgM with recombinant human secretory component (SC) to generate functional secretoiy-like IgA and IgM. First, biochemical analysis of human plasma IgA and IgM was performed by western blotting and chromatography. These molecules exhibited the same biochemical features as mucosa-derived antibodies (Abs). The association between human plasma plgA or IgM and recombinant human SC was confirmed, as well as the 1:1 stoichiometry of association. Similarly to physiological conditions, this association delayed the degradation of secretory-like IgA or IgM by intestinal proteases. Secondly, the function activity and the mode of action of human plasma IgA and IgM, as well as secretory-like IgA and IgM were explored using an in vitro model of polarized intestinal epithelial Caco-2 cell monolayers mimicking intestinal epithelium. Cell monolayers were infected with an enteropathogen, Shigella flexneri, alone or in combination to plasma Abs or secretory-like Abs. Even though plasma plgA and secretoiy-like IgA resulted in a delay of bacteria-induced damages of cell monolayers, plasma IgM and secretory-like IgM were shown to be superior in maintenance of cell integrity. Polymeric IgA and secretory-like IgA induced bacterial aggregation and decreased cell monolayer inflammation, effects further amplified with IgM and secretory-like IgM. In addition, both secretory-like Abs directly impacted on bacterial virulence leading to a reduction in secretion of virulence factors by bacteria. The functionality of human plasma IgA was also tested against Clostridium difficile toxin A using Caco-2 cell monolayers. Human plasma IgA- enriched preparations led to a diminution of cell monolayer damages and a decrease of cellular inflammation induced by the toxin. The sum of these results demonstrates that secretory-like IgA and IgM can be generated from purified human plasma IgA and IgM associated to SC and that these molecules are functional to protect intestinal epithelium from bacterial infections. These molecules could be now tested using in vivo models. The final goal would be to use them by passive immunization in the treatment of mucosa-associated pathologies like infections in humans.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Pollination syndromes involve convergent evolution towards phenotypes composed of specific scents, colours or floral morphologies that attract or restrict pollinator access to reward. How these traits might influence the distributions of plant species in interaction with pollinators has rarely been investigated. We sampled 870 vegetation plots in the western Swiss Alps and classified the plant species into seven blossom types according to their floral morphology (wind, disk, funnel, tube, bilabiate, head or brush). We investigated the environmental features of plots with functional diversity (FD) lower than expected by chance alone to detect potential pollination filtering and related the proportions of the seven blossom types to a combination of environmental descriptors. From these results, we inferred the potential effect of the pollinator on the spatial distribution of plant species. The vegetation plots with significantly lower FD of blossom types than expected by chance were found at higher altitudes, and the proportions of blossom types were strongly patterned along the same gradient. These results support a biotic filtering effect on plant species assemblages through pollination: disk blossoms became dominant at higher altitudes, resulting in a lower FD. In harsh conditions at high altitudes, pollinators usually decrease in activity, and the openness of the disk blossom grants access to any available pollinator. Inversely, bilabiate blossoms, which are mostly pollinated by bees, were more abundant at lower elevations, which are characterised by greater abundance and diversity of bees. Generalisation through openness of the blossom could be advantageous at high elevations, while specialisation could be a successful alternative strategy at lower elevations. The approach used in this study is purely correlative, and further investigations should be conducted to infer the nature of the causal relationship between plant and pollinator distributions.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: Elevated plasma levels of the elastase alpha 1-proteinase inhibitor complex (E-alpha 1 PI) have been proposed as a marker of bacterial infection and neutrophil activation. Liberation of elastase from neutrophils after collection of blood may cause falsely elevated results. Collection methods have not been validated for critically ill neonates and children. We evaluated the influence of preanalytical methods on E-alpha 1 PI results including the recommended collection into EDTA tubes. DESIGN AND METHODS: First, we compared varying acceleration speeds and centrifugation times. Centrifugation at 1550 g for 3 min resulted in reliable preparation of leukocyte free plasma. Second, we evaluated all collection tubes under consideration for absorption of E-alpha 1 PI. Finally, 12 sets of samples from healthy adults and 42 sets obtained from critically ill neonates and children were distributed into the various sampling tubes. Samples were centrifuged within 15 min of collection and analyzed with a new turbidimetric assay adapted to routine laboratory analyzers. RESULTS: One of the two tubes containing a plasma-cell separation gel absorbed 22.1% of the E-alpha 1 PI content. In the remaining tubes without absorption of E-alpha 1 PI no differences were observed for samples from healthy adult patients. However, in samples from critically ill neonates or children, significantly higher results were obtained for plain Li-heparin tubes (mean = 183 micrograms/L), EDTA tubes (mean = 93 micrograms/L), and citrate tubes (mean = 88.5 micrograms/L) than for the Li-hep tube with cell-plasma separation gel and no absorption of E-alpha 1 PI (mean = 62.4 micrograms/L, p < 0.01). CONCLUSION: Contrary to healthy adults, E-alpha 1 PI results in plasma samples from critically ill neonates and children depend on the type of collection tube.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To determine the lower limit of dose reduction with hybrid and fully iterative reconstruction algorithms in detection of endoleaks and in-stent thrombus of thoracic aorta with computed tomographic (CT) angiography by applying protocols with different tube energies and automated tube current modulation. MATERIALS AND METHODS: The calcification insert of an anthropomorphic cardiac phantom was replaced with an aortic aneurysm model containing a stent, simulated endoleaks, and an intraluminal thrombus. CT was performed at tube energies of 120, 100, and 80 kVp with incrementally increasing noise indexes (NIs) of 16, 25, 34, 43, 52, 61, and 70 and a 2.5-mm section thickness. NI directly controls radiation exposure; a higher NI allows for greater image noise and decreases radiation. Images were reconstructed with filtered back projection (FBP) and hybrid and fully iterative algorithms. Five radiologists independently analyzed lesion conspicuity to assess sensitivity and specificity. Mean attenuation (in Hounsfield units) and standard deviation were measured in the aorta to calculate signal-to-noise ratio (SNR). Attenuation and SNR of different protocols and algorithms were analyzed with analysis of variance or Welch test depending on data distribution. RESULTS: Both sensitivity and specificity were 100% for simulated lesions on images with 2.5-mm section thickness and an NI of 25 (3.45 mGy), 34 (1.83 mGy), or 43 (1.16 mGy) at 120 kVp; an NI of 34 (1.98 mGy), 43 (1.23 mGy), or 61 (0.61 mGy) at 100 kVp; and an NI of 43 (1.46 mGy) or 70 (0.54 mGy) at 80 kVp. SNR values showed similar results. With the fully iterative algorithm, mean attenuation of the aorta decreased significantly in reduced-dose protocols in comparison with control protocols at 100 kVp (311 HU at 16 NI vs 290 HU at 70 NI, P ≤ .0011) and 80 kVp (400 HU at 16 NI vs 369 HU at 70 NI, P ≤ .0007). CONCLUSION: Endoleaks and in-stent thrombus of thoracic aorta were detectable to 1.46 mGy (80 kVp) with FBP, 1.23 mGy (100 kVp) with the hybrid algorithm, and 0.54 mGy (80 kVp) with the fully iterative algorithm.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: Auscultatory nonmercury manual devices seem good alternatives for the mercury sphygmomanometers in the clinic and for research settings, but individual internal validation of each device is time-consuming. The aim of this study was to validate a new technique capable of testing two devices simultaneously, based on the International protocol of the European Society of Hypertension. METHODS: The concept of the new technique is to measure blood pressure alternatively by two observers using a mercury sphygmomanometer and by two observers using the A&D UM-101 and Accoson Greenlight 300 devices, connected by Y-tube to obtain simultaneous readings with both nonmercury devices. Thirty-three participants were enrolled (mean age 47.2±14.0 years). Nine sequential blood pressure measurements were performed for each participant. RESULTS: Both devices passed phase 1 using 15 participants. In phase 2.1 (n=33), on a maximum of 99 measurements, the Accoson device produced 81/95/99 measurements within 5/10/15 mmHg for systolic blood pressure (SBP) and 87/98/99 for diastolic blood pressure (DBP). The A&D device produced 86/96/99 for SBP and 94/99/99 for DBP. In phase 2.2 (n=33), 30 participants had at least 2 out of 3 SBP obtained with Accoson device within 5 mmHg of the mercury device, as compared with 29 of 33 participants with the A&D device. For DBP, this was 33 of 33 participants for both devices. CONCLUSION: Both the nonmercury devices passed the International protocol. The new technique of simultaneous device testing using a Y-tube represents a time saving application of the International protocol.