295 resultados para Venous reflux


Relevância:

70.00% 70.00%

Publicador:

Resumo:

Background: Chronic venous insufficiency (CVI) represents a major global health problem with increasing prevalence and morbidity. CVI is due to an incompetence of the venous valves, which causes venous reflux and distal venous hypertension. Several studies have focused on the replacement of diseased venous valves using xeno- and allogenic transplants, so far with moderate success due to immunologic and thromboembolic complications. Autologous cell-derived tissue-engineered venous valves (TEVVs) based on fully biodegradable scaffolds could overcome these limitations by providing non-immunogenic, non-thrombogenic constructs with remodeling and growth potential. Methods: Tri- and bicuspid venous valves (n=27) based on polyglycolic acid-poly-4-hydroxybutyrate composite scaffolds, integrated into self-expandable nitinol stents, were engineered from autologous ovine bone-marrow-derived mesenchymal stem cells (BM-MSCs) and endothelialized. After in vitro conditioning in a (flow) pulse duplicator system, the TEVVs were crimped (n=18) and experimentally delivered (n=7). The effects of crimping on the tissue-engineered constructs were investigated using histology, immunohistochemistry, scanning electron microscopy, grating interferometry (GI), and planar fluorescence reflectance imaging. Results: The generated TEVVs showed layered tissue formation with increasing collagen and glycosaminoglycan levels dependent on the duration of in vitro conditioning. After crimping no effects were found on the MSC level in scanning electron microscopy analysis, GI, histology, and extracellular matrix analysis. However, substantial endothelial cell loss was detected after the crimping procedure, which could be reduced by increasing the static conditioning phase. Conclusions: Autologous living small-diameter TEVVs can be successfully fabricated from ovine BM-MSCs using a (flow) pulse duplicator conditioning approach. These constructs hold the potential to overcome the limitations of currently used non-autologous replacement materials and may open new therapeutic concepts for the treatment of CVI in the future.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate a diagnostic strategy for pulmonary embolism that combined clinical assessment, plasma D-dimer measurement, lower limb venous ultrasonography, and helical computed tomography (CT). METHODS: A cohort of 965 consecutive patients presenting to the emergency departments of three general and teaching hospitals with clinically suspected pulmonary embolism underwent sequential noninvasive testing. Clinical probability was assessed by a prediction rule combined with implicit judgment. All patients were followed for 3 months. RESULTS: A normal D-dimer level (<500 microg/L by a rapid enzyme-linked immunosorbent assay) ruled out venous thromboembolism in 280 patients (29%), and finding a deep vein thrombosis by ultrasonography established the diagnosis in 92 patients (9.5%). Helical CT was required in only 593 patients (61%) and showed pulmonary embolism in 124 patients (12.8%). Pulmonary embolism was considered ruled out in the 450 patients (46.6%) with a negative ultrasound and CT scan and a low-to-intermediate clinical probability. The 8 patients with a negative ultrasound and CT scan despite a high clinical probability proceeded to pulmonary angiography (positive: 2; negative: 6). Helical CT was inconclusive in 11 patients (pulmonary embolism: 4; no pulmonary embolism: 7). The overall prevalence of pulmonary embolism was 23%. Patients classified as not having pulmonary embolism were not anticoagulated during follow-up and had a 3-month thromboembolic risk of 1.0% (95% confidence interval: 0.5% to 2.1%). CONCLUSION: A noninvasive diagnostic strategy combining clinical assessment, D-dimer measurement, ultrasonography, and helical CT yielded a diagnosis in 99% of outpatients suspected of pulmonary embolism, and appeared to be safe, provided that CT was combined with ultrasonography to rule out the disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE. The purpose of this study was to evaluate the prevalence of mesenteric venous thrombosis (MVT) in the Swiss Inflammatory Bowel Disease Cohort Study and to correlate MVT with clinical outcome. MATERIALS AND METHODS. Abdominal portal phase CT was used to examine patients with inflammatory bowel disease (IBD). Two experienced abdominal radiologists retrospectively analyzed the images, focusing on the superior and inferior mesenteric vein branches and looking for signs of acute or chronic thrombosis. The location of abnormalities was registered. The presence of MVT was correlated with IBD-related radiologic signs and complications. RESULTS. The cases of 160 patients with IBD (89 women, 71 men; Crohn disease [CD], 121 patients; ulcerative colitis [UC], 39 patients; median age at diagnosis, 27 years for patients with CD, 32 years for patients with UC) were analyzed. MVT was detected in 43 patients with IBD (26.8%). One of these patients had acute MVT; 38, chronic MVT; and four, both. The prevalence of MVT did not differ between CD (35/121 [28.9%]) and UC (8/39 [20.5%]) (p = 0.303). The location of thrombosis was different between CD and UC (CD, jejunal or ileal veins only [p = 0.005]; UC, rectocolic veins only [p = 0.001]). Almost all (41/43) cases of thrombosis were peripheral. MVT in CD patients was more frequently associated with bowel wall thickening (p = 0.013), mesenteric fat hypertrophy (p = 0.005), ascites (p = 0.002), and mesenteric lymph node enlargement (p = 0.036) and was associated with higher rate of bowel stenosis (p < 0.001) and more intestinal IBD-related surgery (p = 0.016) in the outcome. Statistical analyses for patients with UC were not relevant because of the limited population (n = 8). CONCLUSION. MVT is frequently found in patients with IBD. Among patients with CD, MVT is associated with bowel stenosis and CD-related intestinal surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although extended secondary prophylaxis with low-molecular-weight heparin was recently shown to be more effective than warfarin for cancer-related venous thromboembolism, its cost-effectiveness compared to traditional prophylaxis with warfarin is uncertain. We built a decision analytic model to evaluate the clinical and economic outcomes of a 6-month course of low-molecular-weight heparin or warfarin therapy in 65-year-old patients with cancer-related venous thromboembolism. We used probability estimates and utilities reported in the literature and published cost data. Using a US societal perspective, we compared strategies based on quality-adjusted life-years (QALYs) and lifetime costs. The incremental cost-effectiveness ratio of low-molecular-weight heparin compared with warfarin was 149,865 dollars/QALY. Low-molecular-weight heparin yielded a quality-adjusted life expectancy of 1.097 QALYs at the cost of 15,329 dollars. Overall, 46% (7108 dollars) of the total costs associated with low-molecular-weight heparin were attributable to pharmacy costs. Although the low-molecular-weigh heparin strategy achieved a higher incremental quality-adjusted life expectancy than the warfarin strategy (difference of 0.051 QALYs), this clinical benefit was offset by a substantial cost increment of 7,609 dollars. Cost-effectiveness results were sensitive to variation of the early mortality risks associated with low-molecular-weight heparin and warfarin and the pharmacy costs for low-molecular-weight heparin. Based on the best available evidence, secondary prophylaxis with low-molecular-weight heparin is more effective than warfarin for cancer-related venous thromboembolism. However, because of the substantial pharmacy costs of extended low-molecular-weight heparin prophylaxis in the US, this treatment is relatively expensive compared with warfarin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Smart canula concept allows for collapsed cannula insertion, and self-expansion within a vein of the body. (A) Computational fluid dynamics, and (B) bovine experiments (76+/-3.8 kg) were performed for comparative analyses, prior to (C) the first clinical application. For an 18F access, a given flow of 4 l/min (A) resulted in a pressure drop of 49 mmHg for smart cannula versus 140 mmHg for control. The corresponding Reynolds numbers are 680 versus 1170, respectively. (B) For an access of 28F, the maximal flow for smart cannula was 5.8+/-0.5 l/min versus 4.0+/-0.1 l/min for standard (P<0.0001), for 24F 5.5+/-0.6 l/min versus 3.2+/-0.4 l/min (P<0.0001), and for 20F 4.1+/-0.3 l/min versus 1.6+/-0.3 l/min (P<0.0001). The flow obtained with the smart cannula was 270+/-45% (20F), 172+/-26% (24F), and 134+/-13% (28F) of standard (one-way ANOVA, P=0.014). (C) First clinical application (1.42 m2) with a smart cannula showed 3.55 l/min (100% predicted) without additional fluids. All three assessment steps confirm the superior performance of the smart cannula design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Leg ulcers are a major health and economic problem especially in elderly. More than 70% are associated with venous disease. Compressive therapy is the most effective treatment but bandages are often poorly tolerated and well trained nurses are required to apply them effectively. In recent years, the VAC system (vacuum assisted closure) has profoundly changed the wound healing approach. The objective is now to regenerate the tissues and not to replace them with skin grafts which give uncertain results. The other important challenge is to prevent recurrences. New pharmacologic treatments acting on microcirculation and hemostasis would probably appear in the near future opening new therapeutic perspectives.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this study was to evaluate the prevalence of mesenteric venous thrombosis (MVT) in the Swiss Inflammatory Bowel Disease Cohort Study and to correlate MVT with clinical outcome. MATERIALS AND METHODS: Abdominal portal phase CT was used to examine patients with inflammatory bowel disease (IBD). Two experienced abdominal radiologists retrospectively analyzed the images, focusing on the superior and inferior mesenteric vein branches and looking for signs of acute or chronic thrombosis. The location of abnormalities was registered. The presence of MVT was correlated with IBD-related radiologic signs and complications. RESULTS: The cases of 160 patients with IBD (89 women, 71 men; Crohn disease [CD], 121 patients; ulcerative colitis [UC], 39 patients; median age at diagnosis, 27 years for patients with CD, 32 years for patients with UC) were analyzed. MVT was detected in 43 patients with IBD (26.8%). One of these patients had acute MVT; 38, chronic MVT; and four, both. The prevalence of MVT did not differ between CD (35/121 [28.9%]) and UC (8/39 [20.5%]) (p = 0.303). The location of thrombosis was different between CD and UC (CD, jejunal or ileal veins only [p = 0.005]; UC, rectocolic veins only [p = 0.001]). Almost all (41/43) cases of thrombosis were peripheral. MVT in CD patients was more frequently associated with bowel wall thickening (p = 0.013), mesenteric fat hypertrophy (p = 0.005), ascites (p = 0.002), and mesenteric lymph node enlargement (p = 0.036) and was associated with higher rate of bowel stenosis (p < 0.001) and more intestinal IBD-related surgery (p = 0.016) in the outcome. Statistical analyses for patients with UC were not relevant because of the limited population (n = 8). CONCLUSION: MVT is frequently found in patients with IBD. Among patients with CD, MVT is associated with bowel stenosis and CD-related intestinal surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Despite a common disorder population-based data on gastro-esophageal reflux disease (GERD) in Bangladesh is lacking. This epidemiological study was designed to determine the prevalence of GERD and its association with lifestyle factors. This population-based cross-sectional study was done by door to door interview of randomly selected persons in both urban and rural areas of North Eastern part of Bangladesh by using a validated questionnaire. A cutoff point 3 was chosen as a valid and reliable scale to confirm GERD. Statistical analysis was done by SPSS-12 version and the level of significance was set at P < or = 0.05. A total of 2000 persons with an age range of 15 to 85 years were interviewed; 1000 subjects from urban area and 1000 from rural area. Among the study subjects 1064 were male and 936 were female. A total of 110 persons (5.5%) were found to have GERD symptoms and among them 47 were men and 67 were women. The monthly, weekly and daily prevalence of heart-burn and or acid regurgitation was 5.5%, 5.25% and 2.5% respectively. Female sex, increased age and lower level of education were significantly associated with GERD symptoms. Prevalence was found more among city dwellers (approximately 6.0% versus 4.8%), married (6.23%, n = 86), widowed/widowers (16.83%, n = 17) and day labourer (8.78%). Level of education inversely influenced the prevalence. No significant association of GERD was found with body mass index (BMI) and smoking. Prevalence of GERD in North-Eastern part of Bangladesh was lower than that of western world. Prevalence was found higher in urban population, women, married, widowed/widowers and in poor an dilliterate persons. BMI and smoking had no significant association with GERD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The relationship between platelet count and outcome in patients with acute venous thromboembolism (VTE) has not been consistently explored. RIETE is an ongoing registry of consecutive patients with acute VTE. We categorised patients as having very low- (<80,000/µl), low- (80,000/µl to 150,000/µl), normal- (150,000/µl to 300,000/µl), high- (300,000/µl to 450,000/µl), or very high (>450,000/µl) platelet count at baseline, and compared their three-month outcome. As of October 2012, 43,078 patients had been enrolled in RIETE: 21,319 presenting with pulmonary embolism and 21,759 with deep-vein thrombosis. In all, 502 patients (1.2%) had very low-; 5,472 (13%) low-; 28,386 (66%) normal-; 7,157 (17%) high-; and 1,561 (3.6%) very high platelet count. During the three-month study period, the recurrence rate was: 2.8%, 2.2%, 1.8%, 2.1% and 2.2%, respectively; the rate of major bleeding: 5.8%, 2.6%, 1.7%, 2.3% and 4.6%, respectively; the rate of fatal bleeding: 2.0%, 0.9%, 0.3%, 0.5% and 1.2%, respectively; and the mortality rate: 29%, 11%, 6.5%, 8.8% and 14%, respectively. On multivariate analysis, patients with very low-, low-, high- or very high platelet count had an increased risk for major bleeding (odds ratio [OR]: 2.70, 95% confidence interval [CI]: 1.85-3.95; 1.43 [1.18-1.72]; 1.23 [1.03-1.47]; and 2.13 [1.65-2.75]) and fatal bleeding (OR: 3.70 [1.92-7.16], 2.10 [1.48-2.97], 1.29 [0.88-1.90] and 2.49 [1.49-4.15]) compared with those with normal count. In conclusion, we found a U-shaped relationship between platelet count and the three-month rate of major bleeding and fatal bleeding in patients with VTE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The only available score to assess the risk for fatal bleeding in patients with venous thromboembolism (VTE) has not been validated yet. METHODS: We used the RIETE database to validate the risk-score for fatal bleeding within the first 3 months of anticoagulation in a new cohort of patients recruited after the end of the former study. Accuracy was measured using the ROC curve analysis. RESULTS: As of December 2011, 39,284 patients were recruited in RIETE. Of these, 15,206 had not been included in the former study, and were considered to validate the score. Within the first 3 months of anticoagulation, 52 patients (0.34%; 95% CI: 0.27-0.45) died of bleeding. Patients with a risk score of <1.5 points (64.1% of the cohort) had a 0.10% rate of fatal bleeding, those with a score of 1.5-4.0 (33.6%) a rate of 0.72%, and those with a score of >4 points had a rate of 1.44%. The c-statistic for fatal bleeding was 0.775 (95% CI 0.720-0.830). The score performed better for predicting gastrointestinal (c-statistic, 0.869; 95% CI: 0.810-0.928) than intracranial (c-statistic, 0.687; 95% CI: 0.568-0.806) fatal bleeding. The score value with highest combined sensitivity and specificity was 1.75. The risk for fatal bleeding was significantly increased (odds ratio: 7.6; 95% CI 3.7-16.2) above this cut-off value. CONCLUSIONS: The accuracy of the score in this validation cohort was similar to the accuracy found in the index study. Interestingly, it performed better for predicting gastrointestinal than intracranial fatal bleeding.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Assess the benefit of temporary caval stenting for remote venous drainage during cardiopulmonary bypass (CPB). METHODS: Temporary caval stenting was realized in bovine experiments (65+/-6 kg) by the means of self-expanding (18F for insertion, 36F in situ) venous cannulas (Smartcanula LLC, Lausanne, Switzerland) with various lengths: 43 cm, 53 cm, 63 cm vs. a standard 28F wire armed cannula in trans-jugular fashion. Maximal blood flows were assessed for 20, 25 and 30 mmHg of driving pressure with a motorized table height adjustment system. In addition, the inferior caval diameters (just above its bifurcation) were measured in real time with intra-vascular ultrasound (IVUS). RESULTS: Venous drainage (flow in l/min) at 20 mmHg, 25 mmHg, and 30 mmHg drainage load was 3.5+/-0.5, 3.7+/-0.7 and 4.0+/-0.6 for the 28F standard vs. 4.1+/-0.7, 4.0+/-1.3 and 3.9+/-1.1 for the 36F smart 43 cm, vs. 5.0+/-0.7, 5.3+/-1.3 and 5.4+/-1.4 for the 36F smart 53 cm, vs. 5.2+/-0.5*, 5.6+/-1.1* and 5.8+/-1.0* for the 36F smart 63 cm. The inferior vena caval diameters at 30 mmHg were 13.5+/-4.8 mm for 28F standard, 11.1+/-3.6 for 36F smart 43 cm, 11.3+/-3.2 for 36F 53 cm, and 17.0+/-0.1* for 36F 63 cm (*P<0.05 for 28F standard vs. 36F smart 63 cm long) CONCLUSIONS: The 43 cm self-expanding 36F smartcanula outperforms the 28F standard wire armed cannula at low drainage pressures and without augmentation. Temporary caval stenting with long self-expanding venous cannulas provides even better drainage (+51%).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A venous ulcer is the end result of a long pathological process where venous hypertension represents the principal cause of a number of complications. The physiotherapist by adapting various different therapeutic approaches improves the vascular, joint and respiratory problems of these patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cannula design is of prime importance for venous drainage during cardiopulmonary bypass (CPB). To evaluate cannulas intended for CPB, an in vitro circuit was set up with silicone tubing between the test cannula encased in a movable preload reservoir and another static reservoir. The pressure-drop (DeltaP) value (P-drainage - P-preload) was measured using Millar pressure transducers. Flow rate (Q) was measured using an ultrasound flowmeter. Data display and data recording were controlled using a LabView application, custom made particularly for our experiments. Our results demonstrated that DeltaP, Q, and cannula resistance (DeltaP/Q) values were significantly decreased when the cannula diameter was increased for Smart and Medtronic cannulas. Smartcanula showed 36% and 43% less resistance compared to Medtronic venous and Medtronic femoral cannulas, respectively. The cannula shape (straight- or curved-tips) did not affect the DLP cannula resistance. Out of five cannulas tested, the Smartcanula outperforms the other commercially available cannulas. The mean (DeltaP/Q) values were 3.3 +/- 0.08, 4.07 +/- 0.08, 5.58 +/- 0.10, 5.74 +/- 0.15, and 6.45 +/- 0.15 for Smart, Medtronic, Edwards, Sarns, and Gambro cannulas, respectively (two-way ANOVA, p < 0.0001). In conclusion, the present assay allows discrimination between different forms of cannula with high or low lumen resistance.