46 resultados para Tubo em "T" de silicone
Resumo:
The radicality of wound debridement is an important feature of the surgical treatment of pressure sores. Several methods such as injection of methylene blue or hydrogen peroxide have been proposed to facilitate and optimise the surgical debridement technique, but none of them proved to be sufficient. We present an innovative modification of the pseudo-tumour technique consisting in the injection of fluid silicone. Vulcanisation of the silicone leads to pressure-sore moulding, permitting a more radical and sterile excision. In a series of 10 paraplegic patients presenting with ischial pressure sores, silicone moulding was used to facilitate debridement. Radical en bloc debridement was achieved in all patients. After a minimal follow-up of 2 years, no complications and recurrences occurred. A three-dimensional (3D) analysis of the silicone prints objectified the pyramidal shape of ischial pressure sores. Our study showed that complete resection without capsular lesion can be easily achieved. Further, it allows the surgeon to analyse the shape and size of the resected defect, which might be helpful to select the appropriate defect coverage technique.
Resumo:
We report a tubo-ovarian abscess due to Pasteurella multocida. This zoonotic infection was likely of ascending origin, as Pasteurella was also isolated from vaginal swabs.
Resumo:
One aim of this study is to determine the impact of water velocity on the uptake of indicator polychlorinated biphenyls (iPCBs) by silicone rubber (SR) and low-density polyethylene (LDPE) passive samplers. A second aim is to assess the efficiency of performance reference compounds (PRCs) to correct for the impact of water velocity. SR and LDPE samplers were spiked with 11 or 12 PRCs and exposed for 6 weeks to four different velocities (in the range of 1.6 to 37.7 cm s−1) in river-like flow conditions using a channel system supplied with river water. A relationship between velocity and the uptakewas found for each iPCB and enables to determine expected changes in the uptake due to velocity variations. For both samplers, velocity increases from 2 to 10 cm s−1, 30 cm s−1 (interpolated data) and 100 cm s−1 (extrapolated data) lead to increases of the uptake which do not exceed a factor of 2, 3 and 4.5, respectively. Results also showed that the influence of velocity decreased with increasing the octanol-water coefficient partition (log Kow) of iPCBs when SR is used whereas the opposite effect was observed for LDPE. Time-weighted average (TWA) concentrations of iPCBs in water were calculated from iPCB uptake and PRC release. These calculations were performed using either a single PRC or all the PRCs. The efficiency of PRCs to correct the impact of velocity was assessed by comparing the TWA concentrations obtained at the four tested velocities. For SR, a good agreement was found among the four TWA concentrations with both methods (average RSD b 10%). Also for LDPE, PRCs offered a good correction of the impact of water velocity (average RSD of about 10 to 20%). These results contribute to the process of acceptance of passive sampling in routine regulatory monitoring programs.
Resumo:
Over the past decade, various implantable devices have been developed to treat diseases that were previously difficult to manage such diabetes, chronic pain, and neurodegenerative disorders. However, translation of these novel technologies into clinical practice is often difficult because fibrotic encapsulation and/or rejection impairs device function after body implantation. Ideally, cells of the host tissue should perceive the surface of the implant being similar to the normal extracellular matrix. Here, we developed an innovative approach to provide implant surfaces with adhesive protein micropatterns. The patterns were designed to promote adhesion of fibroblasts and macrophages by simultaneously suppressing fibrogenic activation of both cell types. In a rat model, subcutaneously implanted silicone pads provided with the novel micropatterns caused 6-fold lower formation of inflammatory giant cells compared with clinical grade, uncoated, or collagen-coated silicone implants. We further show that micropatterning of implants resulted in 2-3-fold reduced numbers of pro-fibrotic myofibroblast by inhibiting their mechanical activation. Our novel approach allows controlled cell attachment to implant surfaces, representing a critical advance for enhanced biointegration of implantable medical devices.
Resumo:
After peripheral nerve injury in adult mammals, reestablishment of functional connections depends on several parameters including neurotrophic factors, the extracellular matrix, and hormones. However, little is known about the contribution of hormones to peripheral nerve regeneration. Thyroid hormones, which are required for the development and maturation of the central nervous system, are also important for the development of peripheral nerves. The action of triiodothyronine (T3) on responsive cells is mediated through nuclear thyroid hormone receptors (TRs) which modulate the expression of specific genes in target cells. Thus, to study the effect of T3, it is first necessary to know whether the target tissues possess TRs. The fact that sciatic nerve cells possess functional TRs suggests that these cells can respond to T3 and, as a consequence, that thyroid hormone may be involved in peripheral nerve regeneration. The silicone nerve guide model provides an excellent system to study the action of local administration of T3. Evidence from such studies demonstrate that animals treated locally with T3 at the level of transection have more complete regeneration of sciatic nerve and better functional recovery. Among the possible regulatory mechanisms by which T3 enhances peripheral nerve regeneration is rapid action on both axotomized neurons and Schwann cells which, in turn, produce a lasting and stimulatory effect on peripheral nerve regeneration. It is probable that T3 up- or down-regulates gene expression of one or more growth factors, extracellular matrix, or cell adhesion molecules, all of which stimulate peripheral nerve regeneration. This could explain the greater effect of T3 on nerve regeneration compared with the effect of any one growth factor or adhesion molecule.
Resumo:
Improvement of nerve regeneration and functional recovery following nerve injury is a challenging problem in clinical research. We have already shown that following rat sciatic nerve transection, the local administration of triiodothyronine (T3) significantly increased the number and the myelination of regenerated axons. Functional recovery is a sum of the number of regenerated axons and reinnervation of denervated peripheral targets. In the present study, we investigated whether the increased number of regenerated axons by T3-treatment is linked to improved reinnervation of hind limb muscles. After transection of rat sciatic nerves, silicone or biodegradable nerve guides were implanted and filled with either T3 or phosphate buffer solution (PBS). Neuromuscular junctions (NMJs) were analyzed on gastrocnemius and plantar muscle sections stained with rhodamine alpha-bungarotoxin and neurofilament antibody. Four weeks after surgery, most end-plates (EPs) of operated limbs were still denervated and no effect of T3 on muscle reinnervation was detected at this stage of nerve repair. In contrast, after 14 weeks of nerve regeneration, T3 clearly enhanced the reinnervation of gastrocnemius and plantar EPs, demonstrated by significantly higher recovery of size and shape complexity of reinnervated EPs and also by increased acetylcholine receptor (AChRs) density on post synaptic membranes compared to PBS-treated EPs. The stimulating effect of T3 on EP reinnervation is confirmed by a higher index of compound muscle action potentials recorded in gastrocnemius muscles. In conclusion, our results provide for the first time strong evidence that T3 enhances the restoration of NMJ structure and improves synaptic transmission.
Resumo:
PURPOSE: To assess the role of vitreoretinal surgery in maximizing treatment outcome following complications after proton therapy for uveal melanoma and to evaluate its safety. METHODS: Retrospective chart study on 21 patients (2% of a total of 1,005 treated by proton therapy between January 2003 and August 2007) who had developed a complication requiring vitreoretinal surgery. Mean/median total follow-up after irradiation was 43/43 months (range, 12-70 months). RESULTS: Indications for surgery included vitreous hemorrhage (n = 13), epimacular membrane (n = 5), rhegmatogenous retinal detachment (n = 1), combined vitreous hemorrhage with total serous retinal detachment (n = 1), and vitritis (n = 1). Mean/median interval for vitreoretinal surgery after irradiation was 21/20 months (range, 4-45 months), and mean/median follow-up after pars plana vitrectomy was 22/23 months (range, 2-56 months). Pars plana vitrectomy was combined with retinal photocoagulation (n = 5), air/gas (n = 5), or silicone oil tamponade (n = 1). Mean Snellen visual acuity was 20/200 (0-20/40) before and 20/100 (0-20/25) after pars plana vitrectomy. A transient postoperative rise in intraocular pressure was measured in seven patients. Four patients developed phthisis bulbi. CONCLUSION: Vitreoretinal surgery was efficient in maximizing treatment outcome after proton therapy, as it allowed a better oncologic follow-up. Pars plana vitrectomy permitted panretinal photocoagulation to avoid neovascular glaucoma or retinal detachment repair. Macular surgery improved visual acuity, especially in anterior melanoma, whereas repeated surgery may increase the risk of enucleation.
Resumo:
Treatment of retinal detachment frequently uses biocompatible materials to obtain scleral buckling. These materials are not devoid of consequences on surrounding tissues. In 3 eyes enucleated for failure of surgical treatment using scleral buckling materials, the changes prompted by episcleral implants could be observed. The sclera underwent both an inversion of its curvature and a reduction of its thickness under the material, as well as an encapsulation of the material was observed. While a silicone sponge was used in part to encircle one of these eyes, its capsular inner surface was regular and smooth. In contrast, hydrogel implants used in the three eyes showed a peripheral fragmentation prompting in two of them a typical foreign body giant cell granulomatous reaction. Changes in scleral curvature and scleral thinning were observed reflecting the consequences of the buckling procedure. The capsule formation occurred as it does for any nonabsorbable matérial implanted in tissues. Degradation and fragmentation of the hydrogel material suscitated a granuloma in response to fragments. These hydrogel specific changes should be recognized on microscopic examination of slides of either capsule or eyes previously in contact with this implanted material. They attested of the instability of hydrogel after implantation.
Resumo:
Ventricular assist devices (VADs) are used in treatment for terminal heart failure or as a bridge to transplantation. We created biVAD using the artificial muscles (AMs) that supports both ventricles at the same time. We developed the test bench (TB) as the in vitro evaluating system to enable the measurement of performance. The biVAD exerts different pressure between left and right ventricle like the heart physiologically does. The heart model based on child's heart was constructed in silicone. This model was fitted with the biVAD. Two pipettes containing water with an ultrasonic sensor placed on top of each and attached to ventricles reproduced the preload and the after load of each ventricle by the real-time measurement of the fluid height variation proportionally to the exerted pressure. The LabVIEW software extrapolated the displaced volume and the pressure generated by each side of our biVAD. The development of a standardized protocol permitted the validation of the TB for in vitro evaluation, measurement of the performances of the AM biVAD herein, and reproducibility of data.
Resumo:
Cannula design is of prime importance for venous drainage during cardiopulmonary bypass (CPB). To evaluate cannulas intended for CPB, an in vitro circuit was set up with silicone tubing between the test cannula encased in a movable preload reservoir and another static reservoir. The pressure-drop (DeltaP) value (P-drainage - P-preload) was measured using Millar pressure transducers. Flow rate (Q) was measured using an ultrasound flowmeter. Data display and data recording were controlled using a LabView application, custom made particularly for our experiments. Our results demonstrated that DeltaP, Q, and cannula resistance (DeltaP/Q) values were significantly decreased when the cannula diameter was increased for Smart and Medtronic cannulas. Smartcanula showed 36% and 43% less resistance compared to Medtronic venous and Medtronic femoral cannulas, respectively. The cannula shape (straight- or curved-tips) did not affect the DLP cannula resistance. Out of five cannulas tested, the Smartcanula outperforms the other commercially available cannulas. The mean (DeltaP/Q) values were 3.3 +/- 0.08, 4.07 +/- 0.08, 5.58 +/- 0.10, 5.74 +/- 0.15, and 6.45 +/- 0.15 for Smart, Medtronic, Edwards, Sarns, and Gambro cannulas, respectively (two-way ANOVA, p < 0.0001). In conclusion, the present assay allows discrimination between different forms of cannula with high or low lumen resistance.
Resumo:
BACKGROUND: Large intrathoracic airway defects may be closed using a pedicled latissimus dorsi (LD) flap, with rewarding results. This study addresses the question of whether this holds true for extrathoracic non-circumferential tracheal defects. METHODS: A cervical segment of the trachea of 4 x 1 cm was resected in 9 white male pigs. The defect was stented with a silicone stent for 3 months and closed either by an LD flap alone (group a, n = 3), an LD flap with an attached rib segment covered by pleura (group b, n = 3), or an LD flap reinforced by a perforated polylactide (MacroPore) plate (group c, n = 3). The trachea was assessed by rigid endoscopy at 3 and 4 months and histologically at 4 months postoperatively. RESULTS: The degree of stenosis at the level of the reconstruction at 4 months was 25, 50 and 75% in group a, 15, 50 and 60% in group b, and 20, 95 and 95% in group c, respectively. The percentage of the defect covered by columnar epithelium was 100% in all animals of group a, 60, 100 and 100% in group b, and 10, 0 and 0% in group c. Resorption of the rib was seen in all animals of group b and obstructive inflammatory polyps were found in 2 animals of group c. CONCLUSION: Pedicled LD flaps provided less satisfactory results for closure of large non-circumferential extrathoracic airway defects than observed after intrathoracic reconstruction. A pedicled rib segment added to the LD flap did not improve the results obtained from LD flap repair alone, and an embedded MacroPore prosthesis may result in severe airway stenosis due to plate migration and intense inflammatory reaction protruding into the tracheal lumen.
Resumo:
OBJECTIVE: To investigate the prefabrication of vascularized mucosa-lined composite grafts intended to replace circumferential tracheal defects. DESIGN: Plane grafts composed of ear cartilage and full-thickness oral mucosa were revascularized by the laterothoracic fascia. The use of meshed vs nonmeshed mucosa to improve the epithelial coverage was examined. We also investigated the creation of a vascular bed over the cartilage and the subsequent application of meshed mucosa. Macroscopic aspects, viability, and degree of mucosal lining were analyzed. SUBJECTS: Twenty male New Zealand white rabbits. INTERVENTIONS: Ten animals underwent placement of auricular cartilage under the laterothoracic fascia. Intact (group 1) or meshed mucosa (group 2) was applied over the fascia and protected by a silicone sheet. After 3 weeks, prefabricated grafts were removed for comparison. In 10 other animals, a sheet of perforated cartilage was placed under the laterothoracic fascia. Two weeks later, 5 grafts (group 3) were harvested. The remaining 5 grafts were reopened for mucosal application over the cartilage and revascularized for 3 additional weeks (group 4). RESULTS: Vascularized plane grafts were obtained in all groups. Mucosal lining increased significantly with meshed mucosa (14%-68%; mean, 40%) compared with nonmeshed mucosa (3%-15%; mean, 10%) (P = .008). Induction of a vascular bed over perforated cartilage was achieved, but survival of secondary implanted mucosa was variable. CONCLUSIONS: A reliable technique to prefabricate composite grafts with cartilaginous support and mucosal lining is presented. The use of meshed mucosa significantly improves epithelial coverage.
Resumo:
BACKGROUND: There is concern that surgically-induced weight loss in obese subjects is associated with a disproportionate decrease in lean body mass (LBM) and in skeletal muscle mass (SMM), a major constituent of LBM. To address this issue, 1) we measured total and regional body composition following gastric banding in a group of obese subjects, and 2) we compared these data to those of a non-surgical control group of similar age and body size. METHODS: Body composition was assessed by dual-energy X-ray absorptiometry (DEXA) before and after laparoscopic adjustable silicone gastric banding (LAGB) in 32 women (after 1 year: age 43.7+/-8.4 years, BMI 36.4+/-5.9 kg/m2, mean+/-SD), and in 117 control women (age 44.5+/-7.5 years; BMI 36.7+/-5.5 kg/m2) referred for non-surgical weight management, prior to weight loss. SMM was estimated using a published equation based on LBM of the extremities (appendicular LBM). RESULTS: 1 year after LAGB, body weight loss (-23.7+/-11.6 kg, P<10(-6)) was mainly due to decreased fat mass (-21.2+/-11.2 kg, P<10(-6)), and total LBM was modestly, although significantly, decreased (-2.1+/-4.2 kg, P=0.01). Appendicular LBM (-0.7+/-2.7 kg) and total SMM (-0.9+/-3.0 kg) were not significantly modified. None of the body composition variables was significantly decreased in weight-reduced subjects compared to the control group, especially appendicular LBM and total SMM. CONCLUSIONS: Results provide no evidence for a decrease in appendicular LBM and total SMM with weight loss following LAGB. Follow-up of these obese patients revealed a very favorable pattern of change in total and regional body composition, with preservation of muscle mass.