93 resultados para Modified algorithms


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The algorithmic approach to data modelling has developed rapidly these last years, in particular methods based on data mining and machine learning have been used in a growing number of applications. These methods follow a data-driven methodology, aiming at providing the best possible generalization and predictive abilities instead of concentrating on the properties of the data model. One of the most successful groups of such methods is known as Support Vector algorithms. Following the fruitful developments in applying Support Vector algorithms to spatial data, this paper introduces a new extension of the traditional support vector regression (SVR) algorithm. This extension allows for the simultaneous modelling of environmental data at several spatial scales. The joint influence of environmental processes presenting different patterns at different scales is here learned automatically from data, providing the optimum mixture of short and large-scale models. The method is adaptive to the spatial scale of the data. With this advantage, it can provide efficient means to model local anomalies that may typically arise in situations at an early phase of an environmental emergency. However, the proposed approach still requires some prior knowledge on the possible existence of such short-scale patterns. This is a possible limitation of the method for its implementation in early warning systems. The purpose of this paper is to present the multi-scale SVR model and to illustrate its use with an application to the mapping of Cs137 activity given the measurements taken in the region of Briansk following the Chernobyl accident.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intraoperative cardiac imaging plays a key role during transcatheter aortic valve replacement. In recent years, new techniques and new tools for improved image quality and virtual navigation have been proposed, in order to simplify and standardize stent valve positioning and implantation. But routine performance of the new techniques may require major economic investments or specific knowledge and skills and, for this reason, they may not be accessible to the majority of cardiac centres involved in transcatheter valve replacement projects. Additionally, they still require injections of contrast medium to obtain computed images. Therefore, we have developed and describe here a very simple and intuitive method of positioning balloon-expandable stent valves, which represents the evolution of the 'dumbbell' technique for echocardiography-guided transcatheter valve replacement without angiography. This method, based on the partial inflation of the balloon catheter during positioning, traps the crimped valve in the aortic valve orifice and, consequently, very near to the ideal landing zone. It does not require specific echocardiographic knowledge; it does not require angiographies that increase the risk of postoperative kidney failure in elderly patients, and it can be also performed in centres not equipped with a hybrid operating room.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Matrix effects, which represent an important issue in liquid chromatography coupled to mass spectrometry or tandem mass spectrometry detection, should be closely assessed during method development. In the case of quantitative analysis, the use of stable isotope-labelled internal standard with physico-chemical properties and ionization behaviour similar to the analyte is recommended. In this paper, an example of the choice of a co-eluting deuterated internal standard to compensate for short-term and long-term matrix effect in the case of chiral (R,S)-methadone plasma quantification is reported. The method was fully validated over a concentration range of 5-800 ng/mL for each methadone enantiomer with satisfactory relative bias (-1.0 to 1.0%), repeatability (0.9-4.9%) and intermediate precision (1.4-12.0%). From the results obtained during validation, a control chart process during 52 series of routine analysis was established using both intermediate precision standard deviation and FDA acceptance criteria. The results of routine quality control samples were generally included in the +/-15% variability around the target value and mainly in the two standard deviation interval illustrating the long-term stability of the method. The intermediate precision variability estimated in method validation was found to be coherent with the routine use of the method. During this period, 257 trough concentration and 54 peak concentration plasma samples of patients undergoing (R,S)-methadone treatment were successfully analysed for routine therapeutic drug monitoring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Defining an efficient training set is one of the most delicate phases for the success of remote sensing image classification routines. The complexity of the problem, the limited temporal and financial resources, as well as the high intraclass variance can make an algorithm fail if it is trained with a suboptimal dataset. Active learning aims at building efficient training sets by iteratively improving the model performance through sampling. A user-defined heuristic ranks the unlabeled pixels according to a function of the uncertainty of their class membership and then the user is asked to provide labels for the most uncertain pixels. This paper reviews and tests the main families of active learning algorithms: committee, large margin, and posterior probability-based. For each of them, the most recent advances in the remote sensing community are discussed and some heuristics are detailed and tested. Several challenging remote sensing scenarios are considered, including very high spatial resolution and hyperspectral image classification. Finally, guidelines for choosing the good architecture are provided for new and/or unexperienced user.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: Tissue engineering methods can be applied to regenerate diseased, or congenitally missing, urinary tract tissues. Urinary tract tissue cell cultures must be established in vitro and adequate matrices, acting as cell carriers, must be developed. Although degradable and nondegradable polymer matrices offer adequate mechanical stability, they are not optimal for cell adherence and growth. To overcome this problem, extracellular matrix proteins, permitting cell adhesion and regulation of cell proliferation and differentiation, can be adsorbed to the surface-modified polymer. METHODS: In this study, nondegradable polymer films, poly(ethylene terephthalate), were used as an experimental model. Films were modified by graft polymerization of acrylic acid to subsequently allow collagen type I and III immobilization. The following adhesion, proliferation of human urothelial cells, and induction of their stratification were analyzed. RESULTS: Collagen adsorption on 0.2 microg/cm2 poly(acrylic acid)-grafted polymer films rendered the matrix apt for human urothelial cell adhesion and proliferation. Furthermore, stratification of urothelial cells was demonstrated on these surface-modified matrices. CONCLUSIONS: These results have shown that surface-modified polymer matrices can be used to act as cell carriers for cultured human urothelial cells. Such a cell-matrix construct could be applied in reparative surgery of the urinary tract.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The quantitative assessment of the age-dependent number of neuritic plaques is essential for the diagnosis of Alzheimer type dementia. This study reports the superiority of a modified Hortega-Globus stain compared to Bielschowsky and Bodian stains applied to samples obtained from ten brains of patients with a clinical history of progressive dementia. In two of ten cases only the modified Hortega-Globus stain allowed confirmation of the diagnosis of senile dementia of the Alzheimer type (SDAT). The counts of neuritic plaques in sections stained by other methods were not sufficient to establish the histological diagnosis of SDAT. These results indicate that the choice of the most sensitive staining method is critical for the correct histopathologic diagnosis of the Alzheimer type dementia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An ab initio structure prediction approach adapted to the peptide-major histocompatibility complex (MHC) class I system is presented. Based on structure comparisons of a large set of peptide-MHC class I complexes, a molecular dynamics protocol is proposed using simulated annealing (SA) cycles to sample the conformational space of the peptide in its fixed MHC environment. A set of 14 peptide-human leukocyte antigen (HLA) A0201 and 27 peptide-non-HLA A0201 complexes for which X-ray structures are available is used to test the accuracy of the prediction method. For each complex, 1000 peptide conformers are obtained from the SA sampling. A graph theory clustering algorithm based on heavy atom root-mean-square deviation (RMSD) values is applied to the sampled conformers. The clusters are ranked using cluster size, mean effective or conformational free energies, with solvation free energies computed using Generalized Born MV 2 (GB-MV2) and Poisson-Boltzmann (PB) continuum models. The final conformation is chosen as the center of the best-ranked cluster. With conformational free energies, the overall prediction success is 83% using a 1.00 Angstroms crystal RMSD criterion for main-chain atoms, and 76% using a 1.50 Angstroms RMSD criterion for heavy atoms. The prediction success is even higher for the set of 14 peptide-HLA A0201 complexes: 100% of the peptides have main-chain RMSD values < or =1.00 Angstroms and 93% of the peptides have heavy atom RMSD values < or =1.50 Angstroms. This structure prediction method can be applied to complexes of natural or modified antigenic peptides in their MHC environment with the aim to perform rational structure-based optimizations of tumor vaccines.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RAPPORT DE SYNTHESEBUTLe but de cette étude est de suivre prospectivement les résultats d'une sclérectomie profonde (SP) modifiée en utilisant le tube Ex-PRJESS LR-50, associée à une phacoémulsification avec implantation d'une lentille intraoculaire (LIO), dans la chirurgie combinée du glaucome et de la cataracte.METHODENous avons inclus dans l'étude 24 yeux de 24 patients présentant un glaucome médicalement non contrôlé et une cataracte justifiant son ablation.Une phacoémulsification avec implantation d'une LIO est effectuée. Puis le tube Ex-PRESS LR-50 est inséré au niveau du canal de Schlemm, dans la chambre antérieure, sous un volet scléral. Une SP postérieure partielle est ensuite pratiquée afin de créer une bulle de filtration intrasclérale.Le taux de succès complet a été défini par une pression intraoculaire (PIO) <18 mmHg sans traitement et le taux de succès relatif par une PIO <18 mmHg avec ou sans traitement. En cas de fibrose ou de kyste de la bulle de filtration, une injection sous-conjonctivale d'une solution de Mitomycin C à 0.02% est réalisée, avec ou sans needling.RESULTATSLe suivi moyen était de 40.1±10.8 [moyenne±DS] mois. En préopératoire, la PIO se situait à 18.1 ±5.3 mmHg; la meilleure acuité visuelle corrigée (MAVC) était mesurée à 0.6±0.3 (échelle de Snellen) et le nombre de médicaments hypotenseurs oculaires était de 2.3±1.1. La PIO a diminué de 25.4% à 24 mois et de 27.0% à 48 mois. A 24 mois, 19 patients (86.3%) avaient une MAVC supérieure ou égal à 0.5, et à 48 mois la MAVC était mesurée à 0.7±0.3. Lors de la dernière visite, le nombre moyen de médicaments se situait à 0.6±0.8 (p<0.05). Des injections sous conjonctivales d'une solution de Mitomycin C à 0.02% ont été nécessaires dans 5 yeux. Aucune érosion conjonctivale n'a été constatée. Deux complications majeures ont été observées. Une endophtalmie, deux jours après l'intervention chirurgicale avec phtisis secondaire du globe oculaire. Une obstruction du tube Ex-PRESS LR-50 par de la fibrine, ayant justifié son ablation avec SP classique en un autre site.CONCLUSIONLe tube Ex-PRESS LR-50 inséré dans la chambre antérieure avec une SP modifiée réduit efficacement la PIO dans la chirurgie combinée du glaucome et prévient l'érosion conjonctivale, une complication importante lorsque l'implant n'est pas couvert par un volet scléral.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coronary artery calcification (CAC) is quantified based on a computed tomography (CT) scan image. A calcified region is identified. Modified expectation maximization (MEM) of a statistical model for the calcified and background material is used to estimate the partial calcium content of the voxels. The algorithm limits the region over which MEM is performed. By using MEM, the statistical properties of the model are iteratively updated based on the calculated resultant calcium distribution from the previous iteration. The estimated statistical properties are used to generate a map of the partial calcium content in the calcified region. The volume of calcium in the calcified region is determined based on the map. The experimental results on a cardiac phantom, scanned 90 times using 15 different protocols, demonstrate that the proposed method is less sensitive to partial volume effect and noise, with average error of 9.5% (standard deviation (SD) of 5-7mm(3)) compared with 67% (SD of 3-20mm(3)) for conventional techniques. The high reproducibility of the proposed method for 35 patients, scanned twice using the same protocol at a minimum interval of 10 min, shows that the method provides 2-3 times lower interscan variation than conventional techniques.