24 resultados para MRI CONTRAST AGENTS


Relevância:

40.00% 40.00%

Publicador:

Resumo:

The application of contrast media in post-mortem radiology differs from clinical approaches in living patients. Post-mortem changes in the vascular system and the absence of blood flow lead to specific problems that have to be considered for the performance of post-mortem angiography. In addition, interpreting the images is challenging due to technique-related and post-mortem artefacts that have to be known and that are specific for each applied technique. Although the idea of injecting contrast media is old, classic methods are not simply transferable to modern radiological techniques in forensic medicine, as they are mostly dedicated to single-organ studies or applicable only shortly after death. With the introduction of modern imaging techniques, such as post-mortem computed tomography (PMCT) and post-mortem magnetic resonance (PMMR), to forensic death investigations, intensive research started to explore their advantages and limitations compared to conventional autopsy. PMCT has already become a routine investigation in several centres, and different techniques have been developed to better visualise the vascular system and organ parenchyma in PMCT. In contrast, the use of PMMR is still limited due to practical issues, and research is now starting in the field of PMMR angiography. This article gives an overview of the problems in post-mortem contrast media application, the various classic and modern techniques, and the issues to consider by using different media.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

BACKGROUND: The presence of cognitive and structural deficits in euthymic elderly depressed patients remains a matter of debate. Integrative aetiological models assessing concomitantly these parameters as well as markers of psychological vulnerability such as persistent personality traits, are still lacking for this age group. METHODS: Cross-sectional comparisons of 38 elderly remitted patients with early-onset depression (EOD) and 62 healthy controls included detailed neuropsychological assessment, estimates of brain volumes in limbic areas and white matter hyperintensities, as well as evaluation of the Five-Factor personality dimensions. RESULTS: Both cognitive performances and brain volumes were preserved in euthymic EOD patients. No significant group differences were observed in white matter hyperintensity scores between the two groups. In contrast, EOD was associated with significant increase of Neuroticism and decrease of Extraversion facet scores. LIMITATIONS: Results concern the restricted portion of EOD patients without psychiatric and physical comorbidities. Future longitudinal studies are necessary to determine the temporal relationship between the occurrence of depression and personality dimensions. CONCLUSIONS: After remission from acute depressive symptoms, cognitive performances remain intact in elderly patients with EOD. In contrast to previous observations, these patients display neither significant brain volume loss in limbic areas nor increased vascular burden compared to healthy controls. Further clinical investigations on EOD patterns of vulnerability in old age will gain from focusing on psychological features such as personality traits rather than neurocognitive clues.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: To report the diffusion-weighted MRI findings in alveolar echinococcosis (AE) of the liver and evaluate the potential role of apparent diffusion coefficients (ADCs) in the characterisation of lesions. MATERIALS AND METHODS: We retrospectively included 22 patients with 63 AE liver lesions (≥1cm), examined with 3-T liver MRI, including a free-breathing diffusion-weighted single-shot echo-planar imaging sequence (b-values=50, 300 and 600s/mm(2)). Two radiologists jointly assessed the following lesion features: size, location, presence of cystic and/or solid components (according to Kodama's classification system), relative contrast enhancement, and calcifications (on CT). The ADCtotal, ADCmin and ADCmax were measured in each lesion and the surrounding liver parenchyma. RESULTS: Three type 1, 19 type 2, 17 type 3, three type 4 and 21 type 5 lesions were identified. The mean (±SD) ADCtotal, ADCmin and ADCmax for all lesions were 1.73±0.50, 0.76±0.38 and 2.63±0.76×10(-3)mm(2)/s, respectively. The mean ADCtotal for type 1, type 2, type 3, type 4 and type 5 lesions were 1.97±1.01, 1.76±0.53, 1.73±0.41, 1.15±0.42 and 1.76±0.44×10(-3)mm(2)/s, respectively. No significant differences were found between the five lesion types, except for type 4 (p=0.0363). There was a significant correlation between the presence of a solid component and low ADCmin (r=0.39, p=0.0016), whereas an inverse correlation was found between the relative contrast enhancement and ADCtotal (r=-0.34, p=0.0072). CONCLUSION: The ADCs of AE lesions are relatively low compared to other cystic liver lesions, which may help in the differential diagnosis. Although ADCs are of little use to distinguish between the five lesion types, their low value reflects the underlying solid component.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

INTRODUCTION: Gamma Knife surgery (GKS) is a non-invasive neurosurgical stereotactic procedure, increasingly used as an alternative to open functional procedures. This includes targeting of the ventro-intermediate nucleus of the thalamus (e.g. Vim) for tremor. We currently perform an indirect targeting, as the Vim is not visible on current 3Tesla MRI acquisitions. Our objective was to enhance anatomic imaging (aiming at refining the precision of anatomic target selection by direct visualisation) in patients treated for tremor with Vim GKS, by using high field 7T MRI. MATERIALS AND METHODSH: Five young healthy subjects were scanned on 3 (T1-w and diffusion tensor imaging) and 7T (high-resolution susceptibility weighted images (SWI)) MRI in Lausanne. All images were further integrated for the first time into the Gamma Plan Software(®) (Elekta Instruments, AB, Sweden) and co-registered (with T1 was a reference). A simulation of targeting of the Vim was done using various methods on the 3T images. Furthermore, a correlation with the position of the found target with the 7T SWI was performed. The atlas of Morel et al. (Zurich, CH) was used to confirm the findings on a detailed analysis inside/outside the Gamma Plan. RESULTS: The use of SWI provided us with a superior resolution and an improved image contrast within the basal ganglia. This allowed visualization and direct delineation of some subgroups of thalamic nuclei in vivo, including the Vim. The position of the target, as assessed on 3T, perfectly matched with the supposed one of the Vim on the SWI. Furthermore, a 3-dimensional model of the Vim-target area was created on the basis of the obtained images. CONCLUSION: This is the first report of the integration of SWI high field MRI into the LGP, aiming at the improvement of targeting validation of the Vim in tremor. The anatomical correlation between the direct visualization on 7T and the current targeting methods on 3T (e.g. quadrilatere of Guyot, histological atlases) seems to show a very good anatomical matching. Further studies are needed to validate this technique, both by improving the accuracy of the targeting of the Vim (potentially also other thalamic nuclei) and to perform clinical assessment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

OBJECTIVES: Due to the high prevalence of renal failure in transcatheter aortic valve replacement (TAVR) candidates, a non-contrast MR technique is desirable for pre-procedural planning. We sought to evaluate the feasibility of a novel, non-contrast, free-breathing, self-navigated three-dimensional (SN3D) MR sequence for imaging the aorta from its root to the iliofemoral run-off in comparison to non-contrast two-dimensional-balanced steady-state free-precession (2D-bSSFP) imaging. METHODS: SN3D [field of view (FOV), 220-370 mm(3); slice thickness, 1.15 mm; repetition/echo time (TR/TE), 3.1/1.5 ms; and flip angle, 115°] and 2D-bSSFP acquisitions (FOV, 340 mm; slice thickness, 6 mm; TR/TE, 2.3/1.1 ms; flip angle, 77°) were performed in 10 healthy subjects (all male; mean age, 30.3 ± 4.3 yrs) using a 1.5-T MRI system. Aortic root measurements and qualitative image ratings (four-point Likert-scale) were compared. RESULTS: The mean effective aortic annulus diameter was similar for 2D-bSSFP and SN3D (26.7 ± 0.7 vs. 26.1 ± 0.9 mm, p = 0.23). The mean image quality of 2D-bSSFP (4; IQR 3-4) was rated slightly higher (p = 0.03) than SN3D (3; IQR 2-4). The mean total acquisition time for SN3D imaging was 12.8 ± 2.4 min. CONCLUSIONS: Our results suggest that a novel SN3D sequence allows rapid, free-breathing assessment of the aortic root and the aortoiliofemoral system without administration of contrast medium. KEY POINTS: • The prevalence of renal failure is high among TAVR candidates. • Non-contrast 3D MR angiography allows for TAVR procedure planning. • The self-navigated sequence provides a significantly reduced scanning time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pharmacogenetics of antimalarial agents are poorly known, although the application of pharmacogenetics might be critical in optimizing treatment. This population pharmacokinetic-pharmacogenetic study aimed at assessing the effects of single nucleotide polymorphisms (SNPs) in cytochrome P450 isoenzyme genes (CYP, namely, CYP2A6, CYP2B6, CYP2C8, CYP2C9, CYP2C19, CYP2D6, CYP3A4, and CYP3A5) and the N-acetyltransferase 2 gene (NAT2) on the pharmacokinetics of artemisinin-based combination therapies in 150 Tanzanian patients treated with artemether-lumefantrine, 64 Cambodian patients treated with artesunate-mefloquine, and 61 Cambodian patients treated with dihydroartemisinin-piperaquine. The frequency of SNPs varied with the enzyme and the population. Higher frequencies of mutant alleles were found in Cambodians than Tanzanians for CYP2C9*3, CYP2D6*10 (100C → T), CYP3A5*3, NAT2*6, and NAT2*7. In contrast, higher frequencies of mutant alleles were found in Tanzanians for CYP2D6*17 (1023C → T and 2850C → T), CYP3A4*1B, NAT2*5, and NAT2*14. For 8 SNPs, no significant differences in frequencies were observed. In the genetic-based population pharmacokinetic analyses, none of the SNPs improved model fit. This suggests that pharmacogenetic data need not be included in appropriate first-line treatments with the current artemisinin derivatives and quinolines for uncomplicated malaria in specific populations. However, it cannot be ruled out that our results represent isolated findings, and therefore more studies in different populations, ideally with the same artemisinin-based combination therapies, are needed to evaluate the influence of pharmacogenetic factors on the clearance of antimalarials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The photosensitizing properties of m-tetrahydroxyphenylchlorin (mTHPC) and polyethylene glycol-derivatized mTHPC (pegylated mTHPC) were compared in nude mice bearing human malignant mesothelioma, squamous cell carcinoma and adenocarcinoma xenografts. Laser light (20 J/cm2) at 652 nm was delivered to the tumour (surface irradiance) and to an equal-sized area of the hind leg of the animals after i.p. administration of 0.1 mg/kg body weight mTHPC and an equimolar dose of pegylated mTHPC, respectively. The extent of tumour necrosis and normal tissue injury was assessed by histology. Both mTHPC and pegylated mTHPC catalyse photosensitized necrosis in mesothelioma xenografts at drug-light intervals of 1-4 days. The onset of action of pegylated mTHPC seemed slower but significantly exceeds that of mTHPC by days 3 and 4 with the greatest difference being noted at day 4. Pegylated mTHPC also induced significantly larger photonecrosis than mTHPC in squamous cell xenografts but not in adenocarcinoma at day 4, where mTHPC showed greatest activity. The degree of necrosis induced by pegylated mTHPC was the same for all three xenografts. mTHPC led to necrosis of skin and underlying muscle at a drug-light interval of 1 day but minor histological changes only at drug-light intervals from 2-4 days. In contrast, pegylated mTHPC did not result in histologically detectable changes in normal tissues under the same treatment conditions at any drug-light interval assessed. In this study, pegylated mTHPC had advantages as a photosensitizer compared to mTHPC. Tissue concentrations of mTHPC and pegylated mTHPC were measured by high-performance liquid chromatography in non-irradiated animals 4 days after administration. There was no significant difference in tumour uptake between the two sensitizers in mesothelioma, adenocarcinoma and squamous cell carcinoma xenografts. Tissue concentration measurements were of limited use for predicting photosensitization in this model.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The potential and applicability of UHPSFC-MS/MS for anti-doping screening in urine samples were tested for the first time. For this purpose, a group of 110 doping agents with diverse physicochemical properties was analyzed using two separation techniques, namely UHPLC-MS/MS and UHPSFC-MS/MS in both ESI+ and ESI- modes. The two approaches were compared in terms of selectivity, sensitivity, linearity and matrix effects. As expected, very diverse retentions and selectivities were obtained in UHPLC and UHPSFC, proving a good complementarity of these analytical strategies. In both conditions, acceptable peak shapes and MS detection capabilities were obtained within 7min analysis time, enabling the application of these two methods for screening purposes. Method sensitivity was found comparable for 46% of tested compounds, while higher sensitivity was observed for 21% of tested compounds in UHPLC-MS/MS and for 32% in UHPSFC-MS/MS. The latter demonstrated a lower susceptibility to matrix effects, which were mostly observed as signal suppression. In the case of UHPLC-MS/MS, more serious matrix effects were observed, leading typically to signal enhancement and the matrix effect was also concentration dependent, i.e., more significant matrix effects occurred at the lowest concentrations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: Bicuspid aortic valve (BAV) causes complex flow patterns in the ascending aorta (AAo), which may compromise the accuracy of flow measurement by phase-contrast magnetic resonance (PC-MR). Therefore, we aimed to assess and compare the accuracy of forward flow measurement in the AAo, where complex flow is more dominant in BAV patients, with flow quantification in the left ventricular outflow tract (LVOT) and the aortic valve orifice (AV), where complex flow is less important, in BAV patients and controls. METHODS AND RESULTS: Flow was measured by PC-MR in 22 BAV patients and 20 controls at the following positions: (i) LVOT, (ii) AV, and (iii) AAo, and compared with the left ventricular stroke volume (LVSV). The correlation between the LVSV and the forward flow in the LVOT, the AV, and the AAo was good in BAV patients (r = 0.97/0.96/0.93; P < 0.01) and controls (r = 0.96/0.93/0.93; P < 0.01). However, in relation with the LVSV, the forward flow in the AAo was mildly underestimated in controls and much more in BAV patients [median (inter-quartile range): 9% (4%/15%) vs. 22% (8%/30%); P < 0.01]. This was not the case in the LVOT and the AV. The severity of flow underestimation in the AAo was associated with flow eccentricity. CONCLUSION: Flow measurement in the AAo leads to an underestimation of the forward flow in BAV patients. Measurement in the LVOT or the AV, where complex flow is less prominent, is an alternative means for quantifying the systolic forward flow in BAV patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract Part I : Background : Isolated lung perfusion (ILP) was designed for the treatment of loco-regional malignancies of the lung. In contrast to intravenous (IV) drug application, ILP allows for a selective administration of cytostatic agents such as doxorubicin to the lung while sparing non-affected tissues. However, the clinical results with ILP were disappointing. Doxorubicinbased ILP on sarcoma rodent lungs suggested high overall doxorubicin concentrations within the perfused lung but a poor penetration of the cytostatic agent into tumors. The same holds true for liposomal-encapsulated macromolecular doxorubicin (LiporubicinTM) In specific conditions, low-dose photodynamic therapy (PDT) can enhance the distribution of macromolecules across the endothelial bamer in solid tumors. It was recently postulated that tumor neovessels were more responsive to PDT than the normal vasculature. We therefore hypothesized that Visudyne®-mediated PDT could selectively increase liposomal doxorubicin (LiporubicinTM) uptake in sarcoma tumors to rodent lungs during intravenous (IV) drug administration and isolated lung perfusion (ILP). Material and Methods : A sarcoma tumor was generated in the left lung of Fisher rats by subpleural injection of a sarcoma cell ,suspension via thoracotomy. Ten days later, LiporubicinTM is administered IV or by single pass antegrade ILP, with or without Visudyne® -mediated low-dose PDT pre-treatment of the sarcoma bearing lung. The drug concentration and distribution were assessed separately in tumors and lung tissues by high pressure liquid chromatography (HPLC) and fluorescence microscopy (FNI~, respectively. Results : PDT pretreatment before IV LiporubicinTM administration resulted in a significantly higher tumor drug uptake and tumor to lung drug ratio compared to IV drug injection alone without affecting the blood flow and drug distribution in the lung. PDT pre-treatment before LiporubicinTM-based ILP also resulted in a higher tumor drug uptake and a higher tumor to lung drug ratio compared to ILP alone, however, these differences were not significant due to a heterogeneous blood flow drug distribution during ILP which was further accentuated by PDT. Conclusions : Low-dose Visudyne®-mediated PDT pre-treatment has the potential to selectively enhance liposomal encapsulated doxorubicin uptake in tumors but not in normal lung tissue after IV drug application in a rat model of sarcoma tumors to the lung which opens new perspectives for the treatment of superficially spreading chemoresistant tumors of the chest cavity such as mesothelioma or malignant effusion. However, the impact of PDT on macromolecular drug uptake during ILP is limited since its therapeutic advantage is circumvented by ILP-induced heterogeneicity of blood flow and drug distribution Abstract Part II Background : Photodynamic therapy (PDT) with Visudyne® acts by direct cellular phototoxicity and/or by an indirect vascular-mediated effect. Here, we demonstrate that the vessel integrity interruption by PDT can promote the extravasation of a macromolecular agent in normal tissue. To obtain extravasation in normal tissue PDT conditions were one order of magnitude more intensive than the ones in tissue containing neovessels reported in the literature. Material and Methods : Fluorescein isothiocyanate dextran (FITC-D, 2000kDa), a macromolecular agent, was intravenously injected 10 minutes before (LKO group, n=14) or 2 hours (LK2 group, n=16) after Visudyne® mediated PDT in nude mice bearing a dorsal skin fold chamber. Control animals had no PDT (CTRL group, n=8). The extravasation of FITC-D from blood vessels in striated muscle tissue was observed in both groups in real-time for up to 2500 seconds after injection. We also monitored PDT-induced leukocyte rolling in-vivo and assessed, by histology, the corresponding inflammatory reaction score in the dorsal skin fold chambers. Results : In all animals, at the applied PDT conditions, FITC-D extravasation was significantly enhanced in the PDT treated areas as compared to the surrounding non-treated areas (p<0.0001). There was no FITC-D leakage in the control animals. Animals from the LKO group had significantly less FITC-D extravasation than those from the LK2 group (p = 0.0002). In the LKO group FITC-D leakage correlated significantly with the inflammation (p < 0.001). Conclusions: At the selected conditions, Visudyne-mediated PDT promotes vascular leakage and FITC-D extravasation into the interstitial space of normal tissue. The intensity of vascular leakage depends on the time interval between PDT and FITC-D injection. This concept could be used to locally modulate the delivery of macromolecules in vivo. Résumé : La perfusion cytostatique isolée du poumon permet une administration sélective des agents cytostatiques sans implication de la circulation systémique avec une forte accumulation au niveau du poumon mais une faible pénétration dans les tumeurs. La thérapie photodynamique (PDT) qui consiste en l'application d'un sensibilisateur activé par lumière laser non- thermique d'une longueur d'onde définie permet dans certaines conditions, une augmentation de la pénétration des agents cytostatiques macromoléculaires à travers la barrière endothéliale tumorale. Nous avons exploré cet avantage thérapeutique de la PDT dans un modèle expérimental afin d'augmenter d'une manière sélective la pénétration tumorale de la doxorubicin pegylée, liposomal- encapsulée macromoléculaire (Liporubicin). Une tumeur sarcomateuse a été générée au niveau du poumon de rongeur suivie d'administration de Liporubicin, soit par voie intraveineuse soit par perfusion isolée du poumon (ILP). Une partie des animaux ont reçus un prétraitement de la tumeur et du poumon sous jacent par PDT avec Visudyne comme photosensibilisateur. Les résultats ont démontrés que la PDT permet, sous certaines conditions, une augmentation sélective de Liporubicin dans les tumeurs mais pas dans le parenchyme pulmonaire sous jacent. Après administration intraveineuse de Liporubicin et prétraitement par PDT, l'accumulation dans les tumeurs était significative par rapport au poumon, et aux tumeurs sans PDT. Le même phénomène est observé après ILP du poumon. Cependant, les différences avec ou sans PDT n'étaient pas significatives lié à und distribution hétérogène de Liporubicin dans le poumon perfusé après ILP. Dans une deuxième partie de l'expérimentation, nous avons exploré la microscopie intra-vitale pour déterminer l'extravasion des substances macromoléculaires (FITS) à travers la barrière endothéliale avec ou sans Visudyne-PDT au niveau des chambres dorsales des souris nues. Les résultats montrent qu'après PDT, l'extravasion de FITS a été augmentée de manière significative par rapport au tissu non traité. L'intensité de l'extravasion de FITS dépendait également de l'intervalle entre PDT et injection de FITS. En conclusion, les expérimentations montrent que la PDT est capable, sous certaines conditions, d'augmenter de manière significative l'extravasion des macromolécules à travers la barrière endothéliale et leur accumulation dans des tumeurs mais pas dans le parenchyme pulmonaire. Ces résultats permettent une nouvelle perspective de traitement pour des tumeurs superficielles intrathoraciques chimio-résistent comme l'épanchement pleural malin ou le mésothéliome pleural.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: First, to report ECU subsheath's normal MRI appearance and the findings in athletic injuries. Second, to determine the best MRI sequence for diagnosis. Methods and materials: Sixteen patients (13 males, 3 females, mean age 30.3 years) with ECU subsheath's athletic injuries sustained between January 2003 and June 2009 were retrospectively reviewed. Wrist MRI studies were performed on 1.5-T units and consisted of at least transverse T1 and STIR sequences in pronation, and FS Gd T1 in pronation and supination. Two radiologists assessed the following items, in consensus: injury type (A to C according to Inoue), ECU tendon stability, and associated lesions (ulnar head oedema, extensor retinaculum injury, ECU tendinosis and tenosynovitis). Then, each reader independently rated the sequences' diagnostic value: 0 = questionable, 1 = suggestive, 2 = certain. Follow-up studies were present in 8 patients. ECU subsheath's normal visibility (medial, central and lateral parts) was retrospectively evaluated in 30 consecutive control MRI studies. Results: FS Gd T1 sequences in supination (1.63) and pronation (1.59) were the most valuable for diagnosis, compared to STIR (1.22) and T1 (1). The study group included 9 type A, 1 type B and 6 type C injuries. There were trends towards diminution in pouches' size, signal intensity and enhancement in follow-up studies, along with tendon stabilization within the ulnar groove. In control studies, ECU subsheath's visibility in medial, central and lateral parts were noted in 66.7-80%, 63.3-80% and 30-50% respectively. Conclusion: ECU subsheath's athletic injuries are visible on 1.5-T MRI studies. FS Gd T1 sequences in supination and pronation are the most valuable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Digital holographic microscopy (DHM) allows optical-path-difference (OPD) measurements with nanometric accuracy. OPD induced by transparent cells depends on both the refractive index (RI) of cells and their morphology. This Letter presents a dual-wavelength DHM that allows us to separately measure both the RI and the cellular thickness by exploiting an enhanced dispersion of the perfusion medium achieved by the utilization of an extracellular dye. The two wavelengths are chosen in the vicinity of the absorption peak of the dye, where the absorption is accompanied by a significant variation of the RI as a function of the wavelength.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate the effects of recent advances in magnetic resonance imaging (MRI) radiofrequency (RF) coil and parallel imaging technology on brain volume measurement consistency. MATERIALS AND METHODS: In all, 103 whole-brain MRI volumes were acquired at a clinical 3T MRI, equipped with a 12- and 32-channel head coil, using the T1-weighted protocol as employed in the Alzheimer's Disease Neuroimaging Initiative study with parallel imaging accelerations ranging from 1 to 5. An experienced reader performed qualitative ratings of the images. For quantitative analysis, differences in composite width (CW, a measure of image similarity) and boundary shift integral (BSI, a measure of whole-brain atrophy) were calculated. RESULTS: Intra- and intersession comparisons of CW and BSI measures from scans with equal acceleration demonstrated excellent scan-rescan accuracy, even at the highest acceleration applied. Pairs-of-scans acquired with different accelerations exhibited poor scan-rescan consistency only when differences in the acceleration factor were maximized. A change in the coil hardware between compared scans was found to bias the BSI measure. CONCLUSION: The most important findings are that the accelerated acquisitions appear to be compatible with the assessment of high-quality quantitative information and that for highest scan-rescan accuracy in serial scans the acquisition protocol should be kept as consistent as possible over time. J. Magn. Reson. Imaging 2012;36:1234-1240. ©2012 Wiley Periodicals, Inc.