36 resultados para Electronic monitoring of youth--South Carolina--Richland County
Resumo:
Nonadherence to treatment is a common problem in the clinical management of hypercholesterolemic patients. This study was carried out with the aim of monitoring the daily compliance to a 6-month course of lipid-lowering therapy, using a microelectronic device, the Medication Event Monitoring System (MEMS), versus pill count. Forty men with primary hypercholesterolemia were prescribed fluvastatin 1 x 40 mg daily, provided in a MEMS package to record the date and time of each opening of the pillbox. Thirty-nine of 40 patients (98%) completed the study. Total cholesterol and LDL cholesterol levels decreased significantly (18% and 25%, p < 0.001) during the 6-month therapy period. A high mean rate of compliance was achieved by MEMS using the following three indexes--compliance to total prescribed dose (88.8% +/- 13.5%), compliance to prescribed days (82.4% +/- 19.5%), and compliance to prescribed time of day (81.86% +/- 19.5%)--and by pill count (93.4% +/- 9.5%). In addition, the MEMS provided some patterns of nonadherence to medication, undetectable by pill count alone, such as a drug holiday in 38% of cases, a drug omission for more than 7 consecutive days in 9% of cases, and, conversely, use of more than the one prescribed daily dose in 47% of cases. A significant correlation between the rate of compliance and the decrease in LDL cholesterol was observed only when the compliance was assessed by MEMS. The results indicate that MEMS is a useful tool for monitoring compliance in clinical practice and may possibly increase adherence to long-term lipid-lowering therapy.
Resumo:
BACKGROUND: Poor long-term adherence is an important cause of uncontrolled hypertension. We examined whether monitoring drug adherence with an electronic system improves long-term blood pressure (BP) control in hypertensive patients followed by general practitioners (GPs). METHODS: A pragmatic cluster randomised controlled study was conducted over one year in community pharmacists/GPs' networks randomly assigned either to usual care (UC) where drugs were dispensed as usual, or to intervention (INT) group where drug adherence could be monitored with an electronic system (Medication Event Monitoring System). No therapy change was allowed during the first 2 months in both groups. Thereafter, GPs could modify therapy and use electronic monitors freely in the INT group. The primary outcome was a target office BP<140/90 mmHg. RESULTS: Sixty-eight treated uncontrolled hypertensive patients (UC: 34; INT: 34) were enrolled. Over the 12-month period, the likelihood of reaching the target BP was higher in the INT group compared to the UC group (p<0.05). At 4 months, 38% in the INT group reached the target BP vs. 12% in the UC group (p<0.05), and 21% vs. 9% at 12 months (p: ns). Multivariate analyses, taking account of baseline characteristics, therapy modification during follow-up, and clustering effects by network, indicate that being allocated to the INT group was associated with a greater odds of reaching the target BP at 4 months (p<0.01) and at 12 months (p=0.051). CONCLUSION: GPs monitoring drug adherence in collaboration with pharmacists achieved a better BP control in hypertensive patients, although the impact of monitoring decreased with time.
Resumo:
Hypertensive patients often experience poor adherence to treatment, a frequent cause of uncontrolled blood pressure. In this study, we have evaluated whether or not the use of electronic monitoring for drug adherence is a useful approach to identify and correct compliance problems in hypertensive patients, which may ultimately enhance the effect of antihypertensive therapy. Sixty-nine treated patients with an office blood pressure greater than 140/90 mm Hg were enrolled in this study. With patient consent, current antihypertensive therapy was dispensed in electronic pillboxes that record the time and date of each opening without changing the drug regimen. The intention was to provide physicians with objective measurements of drug compliance. The monitoring of compliance per se without any other intervention induced a marked decrease of blood pressure in the whole group (from 159/104Â+/-23/12 mm Hg to 143/92Â+/-20/15, meansÂ+/-standard deviation, p less than 0.001). A complete normalization of blood pressure (less than 140/90 mm Hg) was obtained in one third of the patients (group 1, n=23) during the monitoring period. A significant improvement of blood pressure control was found in another third (group 2, n=23), whereas in the remaining patients (group 3, n=23) no change in blood pressure was observed. The distribution of individual compliance values, as well as the mean compliances was comparable in the three subgroups. Conversely, the compliance reports have identified several potentially overtreated patients in group 1, a large number of patients with a poor adherence to the prescribed therapy in all groups, and patients who clearly needed a change in pharmacotherapy mainly in group 3. Thus, our results suggest that electronic monitoring of compliance can considerably enhance the efficacy of antihypertensive therapy in patients with uncontrolled hypertension. This procedure should be used more extensively in clinical practice whenever the blood pressure response to therapy appears insufficient. (c)2000 by Le Jacq Communications, Inc.
Resumo:
En 1981, le gouvernement de l'Alberta a amélioré la surveillance de la pointe sud « South Peak » de la montagne Turtle, sur la frontière sud du glissement Frank de 1903. Le programme de surveillance vise à comprendre les taux de déformation des fissures larges et profondes sur « South Peak », et à prédire une seconde avalanche rocheuse sur la montagne. Le programme de surveillance consiste à installer un complément de points statiques et de stations suivies à distance, qui sont mesurés périodiquement. Des données climatiques, microsismiques et de déformation sont recueillies automatiquement à intervalles journaliers, et sont archivées. À la fin des années 1980, le financement pour le développement du programme de surveillance a cessé et quelques installations se sont détériorées. Entre mai 2004 et septembre 2006, des lectures sur les points de surveillance encore fonctionnels ont été compilées et interprétées. De plus, les lectures prélevées auparavant ont été réinterprétées à partir des connaissances récentes sur les modèles de mouvement à court terme et les influences climatiques. Ces observations ont été comparées à des récentes observations aériennes d'un modèle digital d'élévation, provenant de « light detection and ranging (LiDAR) », et des photos de terrain, afin d'estimer plus précisément les taux, l'étendue et la distribution des mouvements pour les derniers 25 ans.
Resumo:
OBJECTIVE: Incomplete compliance is one of several possible causes of uncontrolled hypertension. Yet, non-compliance remains largely unrecognized and is falsely interpreted as treatment resistance, because it is difficult to confirm or exclude objectively. The goal of this study was to evaluate the potential benefits of electronic monitoring of drug compliance in the management of patients with resistant hypertension. METHODS: Forty-one hypertensive patients resistant to a three-drug regimen (average blood pressure 156/ 106 +/- 23/11 mmHg, mean +/- SD) were studied prospectively. They were informed that for the next 2 months, their presently prescribed drugs would be provided in electronic monitors, without any change in treatment, so as to provide the treating physician with a measure of their compliance. Thereafter, patients were offered the possibility of prolonging the monitoring of compliance for another 2 month period, during which treatment was adapted if necessary. RESULTS: Monitoring of compliance alone was associated with a significant improvement of blood pressure at 2 months (145/97 +/- 20/15 mmHg, P < 0.01). During monitoring, blood pressure was normalized (systolic < 140 mmHg or diastolic < 90 mmHg) in one-third of the patients and insufficient compliance was unmasked in another 20%. When analysed according to tertiles of compliance, patients with the lowest compliance exhibited significantly higher achieved diastolic blood pressures (P = 0.04). In 30 patients, compliance was monitored up to 4 months and drug therapy was adapted whenever necessary. In these patients, a further significant decrease in blood pressure was obtained (from 150/100 +/- 18/15 to 143/94 +/- 22/11 mmHg, P = 0.04/0.02). CONCLUSIONS: These results suggest that objective monitoring of compliance using electronic devices may be a useful step in the management of patients with refractory hypertension, as it enables physicians to take rational decisions based on reliable and objective data of drug compliance and hence to improve blood pressure control.
Resumo:
Most anticancer drugs are characterised by a steep dose-response relationship and narrow therapeutic window. Inter-individual pharmacokinetic (PK) variability is often substantial. The most relevant PK parameter for cytotoxic drugs is the area under the plasma concentration versus time curve (AUC). Thus it is somewhat surprising that therapeutic drug monitoring (TDM) is still uncommon for the majority of agents. Goals of the review were to assess the rationale for more widely used TDM of cytotoxics in oncology. There are several reasons why TDM has never been fully implemented into daily oncology practice. These include difficulties in establishing appropriate concentration target ranges, common use of combination chemotherapies for many tumour types, analytical challenges with prodrugs, intracellular compounds, the paucity of published data from pharmacological trials and 'Day1=Day21' administration schedules. There are some specific situations for which these limitations are overcome, including high dose methotrexate, 5-fluorouracil infusion, mitotane and some high dose chemotherapy regimens. TDM in paediatric oncology represents an important challenge. Established TDM approaches includes the widely used anticancer agents carboplatin, busulfan and methotrexate, with 13-cis-retinoic acid also recently of interest. Considerable effort should be made to better define concentration-effect relationships and to utilise tools such as population PK/PD models and comparative randomised trials of classic dosing versus pharmacokinetically guided adaptive dosing. There is an important heterogeneity among clinical practices and a strong need to promote TDM guidelines among the oncological community.
Resumo:
Tobacco consumption is a global epidemic responsible for a vast burden of disease. With pharmacological properties sought-after by consumers and responsible for addiction issues, nicotine is the main reason of this phenomenon. Accordingly, smokeless tobacco products are of growing popularity in sport owing to potential performance enhancing properties and absence of adverse effects on the respiratory system. Nevertheless, nicotine does not appear on the 2011 World Anti-Doping Agency (WADA) Prohibited List or Monitoring Program by lack of a comprehensive large-scale prevalence survey. Thus, this work describes a one-year monitoring study on urine specimens from professional athletes of different disciplines covering 2010 and 2011. A method for the detection and quantification of nicotine, its major metabolites (cotinine, trans-3-hydroxycotinine, nicotine-N'-oxide and cotinine-N-oxide) and minor tobacco alkaloids (anabasine, anatabine and nornicotine) was developed, relying on ultra-high pressure liquid chromatography coupled to triple quadrupole mass spectrometry (UHPLC-TQ-MS/MS). A simple and fast dilute-and-shoot sample treatment was performed, followed by hydrophilic interaction chromatography-tandem mass spectrometry (HILIC-MS/MS) operated in positive electrospray ionization (ESI) mode with multiple reaction monitoring (MRM) data acquisition. After method validation, assessing the prevalence of nicotine consumption in sport involved analysis of 2185 urine samples, accounting for 43 different sports. Concentrations distribution of major nicotine metabolites, minor nicotine metabolites and tobacco alkaloids ranged from 10 (LLOQ) to 32,223, 6670 and 538 ng/mL, respectively. Compounds of interest were detected in trace levels in 23.0% of urine specimens, with concentration levels corresponding to an exposure within the last three days for 18.3% of samples. Likewise, hypothesizing conservative concentration limits for active nicotine consumption prior and/or during sport practice (50 ng/mL for nicotine, cotinine and trans-3-hydroxycotinine and 25 ng/mL for nicotine-N'-oxide, cotinine-N-oxide, anabasine, anatabine and nornicotine) revealed a prevalence of 15.3% amongst athletes. While this number may appear lower than the worldwide smoking prevalence of around 25%, focusing the study on selected sports highlighted more alarming findings. Indeed, active nicotine consumption in ice hockey, skiing, biathlon, bobsleigh, skating, football, basketball, volleyball, rugby, American football, wrestling and gymnastics was found to range between 19.0 and 55.6%. Therefore, considering the adverse effects of smoking on the respiratory tract and numerous health threats detrimental to sport practice at top level, likelihood of smokeless tobacco consumption for performance enhancement is greatly supported.
Resumo:
OBJECT: Cerebrovascular pressure reactivity is the ability of cerebral vessels to respond to changes in transmural pressure. A cerebrovascular pressure reactivity index (PRx) can be determined as the moving correlation coefficient between mean intracranial pressure (ICP) and mean arterial blood pressure. METHODS: The authors analyzed a database consisting of 398 patients with head injuries who underwent continuous monitoring of cerebrovascular pressure reactivity. In 298 patients, the PRx was compared with a transcranial Doppler ultrasonography assessment of cerebrovascular autoregulation (the mean index [Mx]), in 17 patients with the PET-assessed static rate of autoregulation, and in 22 patients with the cerebral metabolic rate for O(2). Patient outcome was assessed 6 months after injury. RESULTS: There was a positive and significant association between the PRx and Mx (R(2) = 0.36, p < 0.001) and with the static rate of autoregulation (R(2) = 0.31, p = 0.02). A PRx > 0.35 was associated with a high mortality rate (> 50%). The PRx showed significant deterioration in refractory intracranial hypertension, was correlated with outcome, and was able to differentiate patients with good outcome, moderate disability, severe disability, and death. The graph of PRx compared with cerebral perfusion pressure (CPP) indicated a U-shaped curve, suggesting that too low and too high CPP was associated with a disturbance in pressure reactivity. Such an optimal CPP was confirmed in individual cases and a greater difference between current and optimal CPP was associated with worse outcome (for patients who, on average, were treated below optimal CPP [R(2) = 0.53, p < 0.001] and for patients whose mean CPP was above optimal CPP [R(2) = -0.40, p < 0.05]). Following decompressive craniectomy, pressure reactivity initially worsened (median -0.03 [interquartile range -0.13 to 0.06] to 0.14 [interquartile range 0.12-0.22]; p < 0.01) and improved in the later postoperative course. After therapeutic hypothermia, in 17 (70.8%) of 24 patients in whom rewarming exceeded the brain temperature threshold of 37 degrees C, ICP remained stable, but the average PRx increased to 0.32 (p < 0.0001), indicating significant derangement in cerebrovascular reactivity. CONCLUSIONS: The PRx is a secondary index derived from changes in ICP and arterial blood pressure and can be used as a surrogate marker of cerebrovascular impairment. In view of an autoregulation-guided CPP therapy, a continuous determination of a PRx is feasible, but its value has to be evaluated in a prospective controlled trial.
Resumo:
Monitoring of internal exposure for nuclear medicine workers requires frequent measurements due to the short physical half-lives of most radionuclides used in this field. The aim of this study was to develop screening measurements performed at the workplace by local staff using standard laboratory instrumentation, to detect whether potential intake has occurred. Such measurements do not enable to determine the committed effective dose, but are adequate to verify that a given threshold is not exceeded. For radioiodine, i.e. (123)I, (124)I, (125)I and (131)I, a calibrated surface contamination monitor is placed in front of the thyroid to detect whether the activity threshold has been exceeded. For radionuclides with very short physical half-lives (≤6 h), such as (99m)Tc and those used in positron emission tomography imaging, i.e. (11)C, (15)O, (18)F and (68)Ga, screening procedures consist in performing daily measurements of the ambient dose rate in front of the abdomen. Other gamma emitters used for imaging, i.e. (67)Ga, (111)In and (201)Tl, are measured with a scintillation detector located in front of the thorax. For pure beta emitters, i.e. (90)Y and (169)Er, as well as beta emitters with low-intensity gamma rays, i.e. (153)Sm, (177)Lu, (186)Re and (188)Re, the procedure consists in measuring hand contamination immediately after use. In Switzerland, screening procedures have been adopted by most nuclear medicine services since such measurements enable an acceptable monitoring while taking into account practical and economic considerations.
Resumo:
Background and objectives In humans, circulating CD4(+)CD25(high) T cells contain mainly regulatory T cells (Treg; FoxP3(+)IL-7R alpha(low)), but a small subset is represented by activated effector T cells (Tact; FoxP3(-)IL-7R alpha(high)). The balance between Tact and Treg may be important after transplantation. The aim of this study was first to analyze and correlate CD4(+)CD25(high) Tact and Treg with the clinical status of kidney transplant recipients and second to study prospectively the effect of two immunosuppressive regimens on Tact/Treg during the first year after transplantation.Design, setting, participants, & measurements CD4(+)CD25(high) Tact and Treg were analyzed by flow cytometry, either retrospectively in 90 patients greater than 1 year after kidney transplantation (cross-sectional analysis) or prospectively in 35 patients receiving two immunosuppressive regimens after kidney transplantation (prospective analysis).Results A higher proportion of Tact and a lower proportion of Treg were found in the majority of kidney recipients. In chronic Immoral rejection, a strikingly higher proportion of Tact was present. A subgroup of stable recipients receiving calcineurin inhibitor-free immunosuppression (mycophenolate mofetil, azathioprine, or sirolimus) had Tact values that were similar to healthy individuals. In the prospective analysis, the proportion of Tact significantly increased in both immunosuppression groups during the first year after transplantation.Conclusions These data highlight distinct patterns in the proportion of circulating Tact depending on the clinical status of kidney recipients. Moreover, the prospective analysis demonstrated an increase in the proportion of Tact, regardless of the immunosuppressive regimen. The measurement of Tact, in addition to Treg, may become a useful immune monitoring tool after kidney transplantation. Clin J Am Soc Nephrol 6: 2025-2033, 2011. doi: 10.2215/CJN.09611010
Resumo:
PURPOSE: To review the literature on young people's perspectives on health care with a view to defining domains and indicators of youth-friendly care. METHODS: Three bibliographic databases were searched to identify studies that purportedly measured young people's perspectives on health care. Each study was assessed to identify the constructs, domains, and indicators of adolescent-friendly health care. RESULTS: Twenty-two studies were identified: 15 used quantitative methods, six used qualitative methods and one used mixed methodology. Eight domains stood out as central to young people's positive experience of care. These were: accessibility of health care; staff attitude; communication; medical competency; guideline-driven care; age appropriate environments; youth involvement in health care; and health outcomes. Staff attitudes, which included notions of respect and friendliness, appeared universally applicable, whereas other domains, such as an appropriate environment including cleanliness, were more specific to particular contexts. CONCLUSION: These eight domains provide a practical framework for assessing how well services are engaging young people. Measures of youth-friendly health care should address universally applicable indicators of youth-friendly care and may benefit from additional questions that are specific to the local health setting.
Resumo:
Background:Amplitude-integrated electroencephalogram (aEEG) is increasingly used for neuromonitoring in preterms. We aimed to quantify the effects of gestational age (GA), postnatal age (PNA), and other perinatal factors on the development of aEEG early after birth in very preterm newborns with normal cerebral ultrasounds.Methods:Continuous aEEG was prospectively performed in 96 newborns (mean GA: 29.5 (range: 24.4-31.9) wk, birth weight 1,260 (580-2,120) g) during the first 96 h of life. aEEG tracings were qualitatively (maturity scores) and quantitatively (amplitudes) evaluated using preestablished criteria.Results:A significant increase in all aEEG measures was observed between day 1 and day 4 and for increasing GA (P < 0.001). The effect of PNA on aEEG development was 6.4- to 11.3-fold higher than that of GA. In multivariate regression, GA and PNA were associated with increased qualitative and quantitative aEEG measures, whereas small-for-GA status was independently associated with increased maximum aEEG amplitude (P = 0.003). Morphine administration negatively affected all aEEG measures (P < .05), and caffeine administration negatively affected qualitative aEEG measures (P = 0.02).Conclusion:During the first few days after birth, aEEG activity in very preterm infants significantly develops and is strongly subjected to the effect of PNA. Perinatal factors may alter the early aEEG tracing and interfere with its interpretation.
Resumo:
Most of oral targeted therapies are tyrosine kinase inhibitors (TKIs). Oral administration generates a complex step in the pharmacokinetics (PK) of these drugs. Inter-individual PK variability is often large and variability observed in response is influenced not only by the genetic heterogeneity of drug targets, but also by the pharmacogenetic background of the patient (e.g. cytochome P450 and ABC transporter polymorphisms), patient characteristics such as adherence to treatment and environmental factors (drug-drug interactions). Retrospective studies have shown that targeted drug exposure, reflected in the area under the plasma concentration-time curve (AUC) correlates with treatment response (efficacy/toxicity) in various cancers. Nevertheless levels of evidence for therapeutic drug monitoring (TDM) are however heterogeneous among these agents and TDM is still uncommon for the majority of them. Evidence for imatinib currently exists, others are emerging for compounds including nilotinib, dasatinib, erlotinib, sunitinib, sorafenib and mammalian target of rapamycin (mTOR) inhibitors. Applications for TDM during oral targeted therapies may best be reserved for particular situations including lack of therapeutic response, severe or unexpected toxicities, anticipated drug-drug interactions and/or concerns over adherence treatment. Interpatient PK variability observed with monoclonal antibodies (mAbs) is comparable or slightly lower to that observed with TKIs. There are still few data with these agents in favour of TDM approaches, even if data showed encouraging results with rituximab, cetuximab and bevacizumab. At this time, TDM of mAbs is not yet supported by scientific evidence. Considerable effort should be made for targeted therapies to better define concentration-effect relationships and to perform comparative randomised trials of classic dosing versus pharmacokinetically-guided adaptive dosing.
Resumo:
Monitoring of posture allocations and activities enables accurate estimation of energy expenditure and may aid in obesity prevention and treatment. At present, accurate devices rely on multiple sensors distributed on the body and thus may be too obtrusive for everyday use. This paper presents a novel wearable sensor, which is capable of very accurate recognition of common postures and activities. The patterns of heel acceleration and plantar pressure uniquely characterize postures and typical activities while requiring minimal preprocessing and no feature extraction. The shoe sensor was tested in nine adults performing sitting and standing postures and while walking, running, stair ascent/descent and cycling. Support vector machines (SVMs) were used for classification. A fourfold validation of a six-class subject-independent group model showed 95.2% average accuracy of posture/activity classification on full sensor set and over 98% on optimized sensor set. Using a combination of acceleration/pressure also enabled a pronounced reduction of the sampling frequency (25 to 1 Hz) without significant loss of accuracy (98% versus 93%). Subjects had shoe sizes (US) M9.5-11 and W7-9 and body mass index from 18.1 to 39.4 kg/m2 and thus suggesting that the device can be used by individuals with varying anthropometric characteristics.
Resumo:
Bisphosphonates are known for their strong inhibitory effect on bone resorption. Their influence on bone formation however is less clear. In this study we investigated the spatio-temporal effect of locally delivered Zoledronate on peri-implant bone formation and resorption in an ovariectomized rat femoral model. A cross-linked hyaluronic acid hydrogel was loaded with the drug and applied bilaterally in predrilled holes before inserting polymer screws. Static and dynamic bone parameters were analyzed based on in vivo microCT scans performed first weekly and then biweekly. The results showed that the locally released Zoledronate boosted bone formation rate up to 100% during the first 17 days after implantation and reduced the bone resorption rate up to 1000% later on. This shift in bone remodeling resulted in an increase in bone volume fraction (BV/TV) by 300% close to the screw and 100% further away. The double effect on bone formation and resorption indicates a great potential of Zoledronate-loaded hydrogel for enhancement of peri-implant bone volume which is directly linked to improved implant fixation.