419 resultados para Diagnostic Algorithms
Resumo:
INTRODUCTION: In November 2009, the "3rd Summit on Osteoporosis-Central and Eastern Europe (CEE)" was held in Budapest, Hungary. The conference aimed to tackle issues regarding osteoporosis management in CEE identified during the second CEE summit in 2008 and to agree on approaches that allow most efficient and cost-effective diagnosis and therapy of osteoporosis in CEE countries in the future. DISCUSSION: The following topics were covered: past year experience from FRAX® implementation into local diagnostic algorithms; causes of secondary osteoporosis as a FRAX® risk factor; bone turnover markers to estimate bone loss, fracture risk, or monitor therapies; role of quantitative ultrasound in osteoporosis management; compliance and economical aspects of osteoporosis; and osteoporosis and genetics. Consensus and recommendations developed on these topics are summarised in the present progress report. CONCLUSION: Lectures on up-to-date data of topical interest, the distinct regional provenances of the participants, a special focus on practical aspects, intense mutual exchange of individual experiences, strong interest in cross-border cooperations, as well as the readiness to learn from each other considerably contributed to the establishment of these recommendations. The "4th Summit on Osteoporosis-CEE" held in Prague, Czech Republic, in December 2010 will reveal whether these recommendations prove of value when implemented in the clinical routine or whether further improvements are still required.
Resumo:
The unresolved issue of false-positive D-dimer results in the diagnostic workup of pulmonary embolism Pulmonary embolism (PE) remains a difficult diagnosis as it lacks specific symptoms and clinical signs. After the determination of the pretest PE probability by a validated clinical score, D-dimers (DD) is the initial blood test in the majority of patients whose probability is low or intermediate. The low specificity of DD results in a high number of false-positives that then require thoracic angio-CT. A new clinical decision rule, called the Pulmonary Embolism Rule-out criteria (PERC), identifies patients at such low risk that PE can be safely ruled-out without a DD test. Its safety has been confirmed in US emergency departments, but retrospective European studies showed that it would lead to 5-7% of undiagnosed PE. Alternative strategies are needed to reduce the proportion of false-positive DD results.
Resumo:
The McIsaac scoring system is a tool designed to predict the probability of streptococcal pharyngitis in children aged 3 to 17 years with a sore throat. Although it does not allow the physician to make the diagnosis of streptococcal pharyngitis, it enables to identify those children with a sore throat in whom rapid antigen detection tests have a good predictive value.
Resumo:
BACKGROUND: Tests for recent infections (TRIs) are important for HIV surveillance. We have shown that a patient's antibody pattern in a confirmatory line immunoassay (Inno-Lia) also yields information on time since infection. We have published algorithms which, with a certain sensitivity and specificity, distinguish between incident (< = 12 months) and older infection. In order to use these algorithms like other TRIs, i.e., based on their windows, we now determined their window periods. METHODS: We classified Inno-Lia results of 527 treatment-naïve patients with HIV-1 infection < = 12 months according to incidence by 25 algorithms. The time after which all infections were ruled older, i.e. the algorithm's window, was determined by linear regression of the proportion ruled incident in dependence of time since infection. Window-based incident infection rates (IIR) were determined utilizing the relationship 'Prevalence = Incidence x Duration' in four annual cohorts of HIV-1 notifications. Results were compared to performance-based IIR also derived from Inno-Lia results, but utilizing the relationship 'incident = true incident + false incident' and also to the IIR derived from the BED incidence assay. RESULTS: Window periods varied between 45.8 and 130.1 days and correlated well with the algorithms' diagnostic sensitivity (R(2) = 0.962; P<0.0001). Among the 25 algorithms, the mean window-based IIR among the 748 notifications of 2005/06 was 0.457 compared to 0.453 obtained for performance-based IIR with a model not correcting for selection bias. Evaluation of BED results using a window of 153 days yielded an IIR of 0.669. Window-based IIR and performance-based IIR increased by 22.4% and respectively 30.6% in 2008, while 2009 and 2010 showed a return to baseline for both methods. CONCLUSIONS: IIR estimations by window- and performance-based evaluations of Inno-Lia algorithm results were similar and can be used together to assess IIR changes between annual HIV notification cohorts.
Resumo:
The irritable bowel syndrome has been considered a diagnosis of exclusion and multiple diagnostic procedures were often performed in order to exclude an organic disorder. Nowadays, studies show that in young patients, who match the clinical criteria of irritable bowel syndrome and show no alarm features, the prevalence of underlying organic disorders is low, or at least not higher than in the general population. Based on these findings, current recommendations suggest that no extra diagnostic tests have to be performed in those patients, apart from the serological tests in search of celiac disease, which are recommended for patients presenting an irritable bowel syndrome with diarrhea or a mixed-type irritable bowel syndrome.
Resumo:
Atherosclerotic renal artery disease represents a cause of which little is known but not a cause to be neglected for hypertension and renal insufficiency. Even though its occurrence remains badly defined, atherosclerotic renal artery disease is constantly on the rise due to the aging population, the never prevailing hypertension and diabetes mellitus. This review aims to give a clinical profile of patients presenting with atherosclerotic renal artery disease and to discuss, in the light of study results, which diagnostic evaluation should be used considering the sequence and the benefit and risk of each in order to initiate a personalized treatment. Patients affected by atherosclerotic renal artery disease are likely to have more complications and more extensive target-organ damage than patients without renal artery stenosis. The evolution of the atherosclerotic renal artery disease is in general slow and progressive. Nevertheless, certain clinical cases manifest themselves with the onset of acute renal failure bought upon by the administration of blockers of the rennin-angiotensin-aldosterone system, or by some other causes responsible for a sudden drop in renal plasma flow (e.g., thrombosis of the renal artery). The relationship between atherosclerotic renal artery disease and atherosclerosis is complex, and mediators implicated in the pathophysiology of renovascular disease may also contribute to the progression of cardiovascular damage. An early assumption of the atherosclerotic renal artery stenosis is warranted to determine the adapted treatment (i.e., medical treatment, revascularisation...) just as the assumption and the correction of the more general cardiovascular risk factors.
Resumo:
The effective dose delivered to the patient was determined, by modeling, for 257 types of examinations covering the different modalities of diagnostic and interventional radiology. The basic operational dosimetric quantities considered were obtained from the parameters of the examinations on the basis of dosimetric models. These models required a precise characterization of each examination. The operational dosimetric quantities were converted into doses to organs and effective doses using appropriate conversion factors. The determination of the collective effective dose to the Swiss population requires a number of corrections to account for the variability of several parameters: sensitivity of the detection system, age, gender, and build of the patient. The use of various dosimetric models is illustrated in this paper for a limited number of examination types covering the different radiological modalities, for which the established typical effective doses are given. With regard to individual doses, the study indicated that the average effective doses per type of examination can be classified into three levels: (a) the weakly irradiating examinations (less than 0.1 mSv), which represent 78% of the examinations and 4% of the collective dose, (b) the moderately irradiating examinations (between 0.1 mSv and 10 mSv), which represent 21% of the examinations and 72% of the collective dose, (c) the strongly irradiating examinations (more than 10 mSv), which represent 1% of the examinations and 24% of the collective dose.
Resumo:
ABSTRACT: BACKGROUND: Serologic testing algorithms for recent HIV seroconversion (STARHS) provide important information for HIV surveillance. We have shown that a patient's antibody reaction in a confirmatory line immunoassay (INNO-LIATM HIV I/II Score, Innogenetics) provides information on the duration of infection. Here, we sought to further investigate the diagnostic specificity of various Inno-Lia algorithms and to identify factors affecting it. METHODS: Plasma samples of 714 selected patients of the Swiss HIV Cohort Study infected for longer than 12 months and representing all viral clades and stages of chronic HIV-1 infection were tested blindly by Inno-Lia and classified as either incident (up to 12 m) or older infection by 24 different algorithms. Of the total, 524 patients received HAART, 308 had HIV-1 RNA below 50 copies/mL, and 620 were infected by a HIV-1 non-B clade. Using logistic regression analysis we evaluated factors that might affect the specificity of these algorithms. RESULTS: HIV-1 RNA <50 copies/mL was associated with significantly lower reactivity to all five HIV-1 antigens of the Inno-Lia and impaired specificity of most algorithms. Among 412 patients either untreated or with HIV-1 RNA ≥50 copies/mL despite HAART, the median specificity of the algorithms was 96.5% (range 92.0-100%). The only factor that significantly promoted false-incident results in this group was age, with false-incident results increasing by a few percent per additional year. HIV-1 clade, HIV-1 RNA, CD4 percentage, sex, disease stage, and testing modalities exhibited no significance. Results were similar among 190 untreated patients. CONCLUSIONS: The specificity of most Inno-Lia algorithms was high and not affected by HIV-1 variability, advanced disease and other factors promoting false-recent results in other STARHS. Specificity should be good in any group of untreated HIV-1 patients.
Resumo:
PURPOSE: To determine the lower limit of dose reduction with hybrid and fully iterative reconstruction algorithms in detection of endoleaks and in-stent thrombus of thoracic aorta with computed tomographic (CT) angiography by applying protocols with different tube energies and automated tube current modulation. MATERIALS AND METHODS: The calcification insert of an anthropomorphic cardiac phantom was replaced with an aortic aneurysm model containing a stent, simulated endoleaks, and an intraluminal thrombus. CT was performed at tube energies of 120, 100, and 80 kVp with incrementally increasing noise indexes (NIs) of 16, 25, 34, 43, 52, 61, and 70 and a 2.5-mm section thickness. NI directly controls radiation exposure; a higher NI allows for greater image noise and decreases radiation. Images were reconstructed with filtered back projection (FBP) and hybrid and fully iterative algorithms. Five radiologists independently analyzed lesion conspicuity to assess sensitivity and specificity. Mean attenuation (in Hounsfield units) and standard deviation were measured in the aorta to calculate signal-to-noise ratio (SNR). Attenuation and SNR of different protocols and algorithms were analyzed with analysis of variance or Welch test depending on data distribution. RESULTS: Both sensitivity and specificity were 100% for simulated lesions on images with 2.5-mm section thickness and an NI of 25 (3.45 mGy), 34 (1.83 mGy), or 43 (1.16 mGy) at 120 kVp; an NI of 34 (1.98 mGy), 43 (1.23 mGy), or 61 (0.61 mGy) at 100 kVp; and an NI of 43 (1.46 mGy) or 70 (0.54 mGy) at 80 kVp. SNR values showed similar results. With the fully iterative algorithm, mean attenuation of the aorta decreased significantly in reduced-dose protocols in comparison with control protocols at 100 kVp (311 HU at 16 NI vs 290 HU at 70 NI, P ≤ .0011) and 80 kVp (400 HU at 16 NI vs 369 HU at 70 NI, P ≤ .0007). CONCLUSION: Endoleaks and in-stent thrombus of thoracic aorta were detectable to 1.46 mGy (80 kVp) with FBP, 1.23 mGy (100 kVp) with the hybrid algorithm, and 0.54 mGy (80 kVp) with the fully iterative algorithm.
Resumo:
PURPOSE: To assess how different diagnostic decision aids perform in terms of sensitivity, specificity, and harm. METHODS: Four diagnostic decision aids were compared, as applied to a simulated patient population: a findings-based algorithm following a linear or branched pathway, a serial threshold-based strategy, and a parallel threshold-based strategy. Headache in immune-compromised HIV patients in a developing country was used as an example. Diagnoses included cryptococcal meningitis, cerebral toxoplasmosis, tuberculous meningitis, bacterial meningitis, and malaria. Data were derived from literature and expert opinion. Diagnostic strategies' validity was assessed in terms of sensitivity, specificity, and harm related to mortality and morbidity. Sensitivity analyses and Monte Carlo simulation were performed. RESULTS: The parallel threshold-based approach led to a sensitivity of 92% and a specificity of 65%. Sensitivities of the serial threshold-based approach and the branched and linear algorithms were 47%, 47%, and 74%, respectively, and the specificities were 85%, 95%, and 96%. The parallel threshold-based approach resulted in the least harm, with the serial threshold-based approach, the branched algorithm, and the linear algorithm being associated with 1.56-, 1.44-, and 1.17-times higher harm, respectively. Findings were corroborated by sensitivity and Monte Carlo analyses. CONCLUSION: A threshold-based diagnostic approach is designed to find the optimal trade-off that minimizes expected harm, enhancing sensitivity and lowering specificity when appropriate, as in the given example of a symptom pointing to several life-threatening diseases. Findings-based algorithms, in contrast, solely consider clinical observations. A parallel workup, as opposed to a serial workup, additionally allows for all potential diseases to be reviewed, further reducing false negatives. The parallel threshold-based approach might, however, not be as good in other disease settings.
Resumo:
The presence of chronic diarrhea requires a prompt diagnostic strategy in order to avoid risks of malnutrition and electrolytic disturbances. Two different clinical situations, i.e. collagen colitis and secretory diarrhea, exemplify the diagnostic evaluation of a single symptom. This non exhaustive review should lead to a diagnostic strategy of chronic diarrhea.
Resumo:
Pyogenic liver abscess is a severe condition and a therapeutic challenge. Treatment failure may be due to an unrecognized ingested foreign body that migrated from the gastrointestinal tract. There has recently been a marked increase in the number of reported cases of this condition, but initial misdiagnosis as cryptogenic liver abscess still occurs in the majority of cases. We conducted the current study to characterize this entity and provide a diagnostic strategy applicable worldwide. To this end, data were collected from our case and from a systematic review that identified 59 well-described cases. Another systematic review identified series of cryptogenic-and Asian Klebsiella-liver abscess; these data were pooled and compared with the data from the cases of migrated foreign body liver abscess. The review points out the low diagnostic accuracy of history taking, modern imaging, and even surgical exploration. A fistula found through imaging procedures or endoscopy warrants surgical exploration. Findings suggestive of foreign body migration are symptoms of gastrointestinal perforation, computed tomography demonstration of a thickened gastrointestinal wall in continuity with the abscess, and adhesions seen during surgery. Treatment failure, left lobe location, unique location (that is, only 1 abscess location within the liver), and absence of underlying conditions also point to the diagnosis, as shown by comparison with the cryptogenic liver abscess series. This study demonstrates that migrated foreign body liver abscess is a specific entity, increasingly reported. It usually is not cured when unrecognized, and diagnosis is mainly delayed. This study provides what we consider the best available evidence for timely diagnosis with worldwide applicability. Increased awareness is required to treat this underestimated condition effectively, and further studies are needed.
Resumo:
Charcot neuropathic osteoarthropathy (CNO) is a destructive process affecting the bone and joint structure of diabetic patients and resulting from peripheral neuropathy. It is a limb threatening condition resulting in dramatic deformities associated with severe morbi-mortality. The diagnosis is mostly made by the observation of inflammatory signs and higlight the importance of prompt foot evaluation. Imaging studies may help confirm the diagnosis and the severity of the condition but lack of specificity. The goal of the treatment is to maintain or achieve structural stability of the foot and ankle to prevent further deformity and plantar dislocation. The scientific evidences aren't strong enough to recommend bisphosphonates or acute surgical treatment. Surgery is unanimusly recommended to prevent secondary ulceration.
Resumo:
Since January 2008-de facto 2012-medical physics experts (MPEs) are, by law, to be involved in the optimisation process of radiological diagnostic procedures in Switzerland. Computed tomography, fluoroscopy and nuclear medicine imaging units have been assessed for patient exposure and image quality. Large spreads in clinical practice have been observed. For example, the number of scans per abdominal CT examination went from 1 to 9. Fluoroscopy units showed, for the same device settings, dose rate variations up to a factor of 3 to 7. Quantitative image quality for positron emission tomography (PET)/CT examinations varied significantly depending on the local image reconstruction algorithms. Future work will be focused on promoting team cooperation between MPEs, radiologists and radiographers and on implementing task-oriented objective image quality indicators.