324 resultados para Arteries Radiography
Resumo:
PURPOSE: To report our results of endovascular aneurysm repair (EVAR) over a 10-year period using systematic preoperative collateral artery embolization. METHODS: From 1999 until 2009, 124 patients (117 men; mean age 70.8 years) with abdominal aortic aneurysm (AAA) underwent embolization of patent lumbar and/or inferior mesenteric arteries prior to elective EVAR procedures. Embolization was systematically attempted and, whenever possible, performed using microcoils and a coaxial technique. Follow-up included computed tomography and/or magnetic resonance imaging and abdominal radiography. RESULTS: The technical success for EVAR was 96% (119/124), with 4 patients dying within 30 days (3.2% perioperative mortality) and 1 type III endoleak accounting for the failures. Collateral arteries were occluded spontaneously or by embolization in 60 (48%) of 124 patients. The endoleak rate was 50.9% (74 in 61 patients), most of which were type II (19%). Over a mean clinical follow-up of 60.5±34.1 months (range 1-144), aneurysm sac dimensions decreased in 66 patients, increased in 19 patients, and were stable in 35. The endoleak rate was significantly higher in the patients with increasing sac diameter (p<0.001). Among the patients with patent collateral arteries, 38/64 (59.3%) developed 46 leaks, while 28 leaks appeared in 23 (41%) of 56 patients with collateral artery occlusion (p=0.069). The type II endoleak rate significantly differed between these two groups (47.8% vs. 3.6%, p<0.001). CONCLUSION: Preoperative collateral embolization seems to be a valid method of reducing the incidence of type II endoleak, improving the long-term outcome.
Resumo:
OBJECTIVES: Long occlusions in calcified crural arteries are a major cause of endovascular technical failure in patients with critical limb ischaemia. Therefore, distal bypasses are mainly performed in patients with heavily calcified arteries and with consequently delicate clamping. A new reverse thermosensitive polymer (RTP) is an alternative option to occlude target vessels. The aim of the study is to report our technical experience with RTP and to assess its safety and efficiency to temporarily occlude small calcified arteries during anastomosis time. METHODS: Between July 2010 and December 2011, we used RTP to occlude crural arteries in 20 consecutive patients with 20 venous distal bypasses. We recorded several operative parameters, such as volume of injected RTP, duration of occlusion and anastomotic time. Quality of occlusion was subjectively evaluated. Routine on-table angiography was performed to search for plug emboli. Primary patency, limb salvage and survival rates were reported at 6 months. RESULTS: In all patients, crural artery occlusion was achieved with the RTP without the use of an adjunct occlusion device. Mean volume of RTP used was 0.3 ml proximally and 0.25 ml distally. Mean duration of occlusion was 14.4 ± 4.5 min, while completion of the distal anastomosis lasted 13.4 ± 4.3 min. Quality of occlusion was judged as excellent in eight cases and good in 12 cases. Residual plugs were observed in two patients and removed with an embolectomy catheter, before we amended the technique for dissolution of RTP. At 6 months, primary patency rate was 75% but limb salvage rate was 87.5%. The 30-day mortality rate was 10%. CONCLUSIONS: This study shows that RTP is safe when properly dissolved and effective to occlude small calcified arteries for completion of distal anastomosis.
Resumo:
All patients having undergone a coronarography during 1984 have been surveyed in Switzerland. This retrospective study has used existing data in the 13 centers practicing this diagnostic procedure. 4921 coronarographies were carried out in 1984, amongst 4359 patients. In terms of population-based rates, the national figures are 77 procedures/100,000 residents, and 68 patients/100,000 residents. Female rates are one fourth of the male rates (27/100,000 versus 112/100,000). For both sexes, the highest utilization rates are for the age groups 60-64. Swiss figures are relatively low when compared with other developed countries. However, patterns of utilization are very different within the country: according to the Canton of residence of the patient, the utilization rates (standardized for age and sex) vary from 8/100,000 to 160/100,000. There is a distinct gradient from south-west to north-east, which closely corresponds to the distribution of centers practicing the procedure. More intriguing is the fact that cardiovascular mortality shows an inverse geographical gradient, with the highest mortality in Cantons having the lowest rate of coronarography. Various reasons for the observed variations are discussed, in relation with differences in supply of diagnostic and therapeutic equipments, but also in relation with various patterns of demand related to differential morbidity rates and/or differential patterns of clinical decision.
Resumo:
A cardiac-triggered free-breathing three-dimensional (3D) balanced fast field-echo projection renal magnetic resonance (MR) angiographic sequence was investigated for in-stent lumen visualization of a dedicated metallic renal artery stent. Fourteen prototype stents were deployed in the renal arteries of six pigs (in two pigs, three stents were deployed). Projection renal MR angiography was compared with standard contrast material-enhanced 3D breath-hold MR angiography. Artifact-free in-stent lumen visualization was achieved with both projection MR angiography and contrast-enhanced MR angiography. These promising results warrant further studies for visualization of in-stent restenosis.
Resumo:
BACKGROUND: To test the hypothesis that intervals with superior beat-to-beat coronary artery repositioning precision exist in the cardiac cycle, to design a coronary MR angiography (MRA) methodology in response, and to ascertain its performance. METHODS: Coronary repositioning precision in consecutive heartbeats was measured on x-ray coronary angiograms of 17 patients and periods with the highest repositioning precision were identified. In response, the temporal order of coronary MRA pulse sequence elements required modification and the T2 -prep now follows (T2 -post) rather than precedes the imaging part of the sequence. The performance of T2 -post was quantitatively compared (signal-to-noise [SNR], contrast-to-noise [CNR], vessel sharpness) to that of T2 -prep in vivo. RESULTS: Coronary repositioning precision is <1 mm at peak systole and in mid diastole. When comparing systolic T2 -post to diastolic T2 -prep, CNR and vessel sharpness remained unchanged (both P = NS) but SNR for muscle and blood increased by 104% and 36% (both P < 0.05), respectively. CONCLUSION: Windows with improved coronary repositioning precision exist in the cardiac cycle: one in peak systole and one in mid diastole. Peak-systolic imaging necessitates a re-design of conventional coronary MRA pulse sequences and leads to image quality very similar to that of conventional mid-diastolic data acquisition but improved SNR. J. Magn. Reson. Imaging 2015;41:1251-1258. © 2014 Wiley Periodicals, Inc.
Resumo:
OBJECTIVES: The goal of the present study was to develop a strategy for three-dimensional (3D) volume acquisition along the major axes of the coronary arteries. BACKGROUND: For high-resolution 3D free-breathing coronary magnetic resonance angiography (MRA), coverage of the coronary artery tree may be limited due to excessive measurement times associated with large volume acquisitions. Planning the 3D volume along the major axis of the coronary vessels may help to overcome such limitations. METHODS: Fifteen healthy adult volunteers and seven patients with X-ray angiographically confirmed coronary artery disease underwent free-breathing navigator-gated and corrected 3D coronary MRA. For an accurate volume targeting of the high resolution scans, a three-point planscan software tool was applied. RESULTS: The average length of contiguously visualized left main and left anterior descending coronary artery was 81.8 +/- 13.9 mm in the healthy volunteers and 76.2 +/- 16.5 mm in the patients (p = NS). For the right coronary artery, a total length of 111.7 +/- 27.7 mm was found in the healthy volunteers and 79.3 +/- 4.6 mm in the patients (p = NS). Comparing coronary MRA and X-ray angiography, a good agreement of anatomy and pathology was found in the patients. CONCLUSIONS: Double-oblique submillimeter free-breathing coronary MRA allows depiction of extensive parts of the native coronary arteries. The results obtained in patients suggest that the method has the potential to be applied in broader prospective multicenter studies where coronary MRA is compared with X-ray angiography.
Resumo:
BACKGROUND: In late-diagnosed transposition of the great arteries (TGA), the left ventricle (LV) involutes as it pumps against low resistance and needs retraining by applying a pulmonary artery band (PAB) in preparation for an arterial switch operation. We report our experience with a telemetrically adaptable band compared with classic banding. METHODS: Ten patients underwent retraining of the LV, 4 patients with an adaptable band and progressive weekly tightening of the band (group 1) and 6 patients with a traditional band (group 2). RESULTS: Mean weight and age at pulmonary band placement was 5.8 ± 2.36 kg and 11.7 ± 11.1 months for group 1 and 5.0 ± 2.3 kg and 6.4 ± 7.6 months for group 2. Time between palliation and switch procedure was 4.2 months in both groups. Group 1 showed an initial mean pulmonary gradient of 25.5 ± 4.43 mm Hg with a 5% closure of the device. The mean gradient increased with progressive closure to 63.5 ± 9.8 mm Hg at the time of the arterial switch operation. There were no reinterventions or deaths in this group. In group 2, the mean pulmonary gradient increased with growth from 49 ± 21.4 mm Hg to 68.4 ± 7.86 mm Hg at the time of the switch procedure. However, 4 of these patients required reoperations during retraining: 2 needed 1 reoperation and 2 needed 2 reoperations. Two patients died-1 after banding and 1 after the switch operation. CONCLUSIONS: Retraining of the LV by the adaptable device allows precise control of the tightening, avoids repetitive operations, and diminishes morbidity.
Resumo:
Nitric oxide (NO) and monocyte chemoattractant protein-1 (MCP-1) exert partly opposing effects in vascular biology. NO plays pleiotropic vasoprotective roles including vasodilation and inhibition of platelet aggregation, smooth muscle cell proliferation, and endothelial monocyte adhesion, the last effect being mediated by MCP-1 downregulation. Early stages of arteriosclerosis are associated with reduced NO bioactivity and enhanced MCP-1 expression. We have evaluated adenovirus-mediated gene transfer of human endothelial NO synthase (eNOS) and of a N-terminal deletion (8ND) mutant of the MCP-1 gene that acts as a MCP-1 inhibitor in arteriosclerosis-prone, apolipoprotein E-deficient (ApoE(-/-)) mice. Endothelium-dependent relaxations were impaired in carotid arteries instilled with a noncoding adenoviral vector but were restored by eNOS gene transfer (p < 0.01). A perivascular collar was placed around the common carotid artery to accelerate lesion formation. eNOS gene transfer reduced lesion surface areas, intima/media ratios, and macrophage contents in the media at 5-week follow-up (p < 0.05). In contrast, 8ND-MCP-1 gene transfer did not prevent lesion formation. In conclusion, eNOS gene transfer restores endothelium-dependent vasodilation and inhibits lesion formation in ApoE(-/-) mouse carotids. Further studies are needed to assess whether vasoprotection is maintained at later disease stages and to evaluate the long-term efficacy of eNOS gene therapy for primary arteriosclerosis.
Resumo:
The present study was aimed at examining the role of nitric oxide (NO) in the hypoxic contraction of isolated small pulmonary arteries (SPA) in the rat. Animals were treated with either saline (sham experiments) or Escherichia coli lipolysaccharide [LPS, to obtain expression of the inducible NO synthase (iNOS) in the lung] and killed 4 h later. SPA (300- to 600-micrometer outer diameter) were mounted as rings in organ chambers for the recording of isometric tension, precontracted with PGF2alpha, and exposed to either severe (bath PO2 8 +/- 3 mmHg) or milder (21 +/- 3 mmHg) hypoxia. In SPA from sham-treated rats, contractions elicited by severe hypoxia were completely suppressed by either endothelium removal or preincubation with an NOS inhibitor [NG-nitro-L-arginine methyl ester (L-NAME), 10(-3) M]. In SPA from LPS-treated rats, contractions elicited by severe hypoxia occurred irrespective of the presence or absence of endothelium and were largely suppressed by L-NAME. The milder hypoxia elicited no increase in vascular tone. These results indicate an essential role of NO in the hypoxic contractions of precontracted rat SPA. The endothelium independence of HPV in arteries from LPS-treated animals appears related to the extraendothelial expression of iNOS. The severe degree of hypoxia required to elicit any contraction is consistent with a mechanism of reduced NO production caused by a limited availability of O2 as a substrate for NOS.
Resumo:
We have investigated the changes in the responses to noradrenaline of isolated tail arteries of spontaneously hypertensive (SHR) and renovascular hypertensive rats (Wistar-Kyoto: two-kidney, one-clip model, WKY:2K1C) compared with normotensive (Wistar-Kyoto, WKY) rats. Renovascular hypertension was induced by 4 weeks' unilateral renal artery clipping. Arteries were vasoconstricted with exogenous noradrenaline, electrical field stimulation or high potassium. The effects of the latter two stimuli were abolished by reserpine and so were presumably dependent on the presence of endogenous noradrenaline. In the SHR the maximal vasoconstriction produced by all three stimuli was greater than in WKY. Dose-response curves were steeper and there was no change in threshold. Vascular mass was greater. We interpret these results as showing an increase in vascular reactivity in the SHR caused by structural adaptation. The WKY:2K1C responses to noradrenaline could also be explained in terms of structural adaptation but there was no increase in vascular mass. Sensitivity to potassium and electrical stimulation was decreased, suggesting a defect in vascular neurotransmission. This was supported by the observations of a decreased arterial noradrenaline content and of decreased sensitivity to cocaine.
Resumo:
BACKGROUND/AIMS: Restenosis after percutaneous transluminal angioplasty (PTA) of the internal mammary artery (IMA) grafts is much less pronounced than in other arteries and venous grafts. The aim of the study was to test whether various arteries respond differently to dilatation. METHODS: PTA of the IMA, carotid, renal and circumflex coronary (RCx) arteries was performed in 9 pigs (balloon to artery ratio of 1:1.5). After 8 weeks, angiography was repeated and vessels prepared for histological analysis. Immunohistochemical staining was done to examine proliferative activity (Ki67) and to identify the vasa vasorum of the adventitia (F VIII-RA). RESULTS: The intima-media ratio after PTA was lowest in the IMA (0.06), followed by the carotid (0.27) and renal arteries (0.49) and the RCx (0.69). Proliferation of the intima was seen at 287 degrees of the vessel circumference in the RCx, at 286 degrees in the renal and at 166 degrees in the carotid artery. No proliferative activity was seen in the IMA. The intima-adventitia ratio was lower in the IMA than in the RCx and renal arteries (p < 0.05). CONCLUSION: Intima proliferation after PTA varies between the different vessels, with best results seen in the IMA. There are differences in remodeling after PTA between muscular, muscular/elastic and elastic arteries.
Resumo:
BACKGROUND: An animal study was carried out to compare long-term patency rates of coronary anastomoses performed with the GraftConnector versus running suture technique. METHODS: 10 sheep, 45 to 55 kg, underwent off-pump coronary artery bypass grafting (right internal mammary artery to left anterior descending artery). In 5 animals, the anastomosis was performed with a GraftConnector and in 5 animals with 7-0 running suture. Intraoperative fluoroscopy and a fluoroscopic control at 6 months were performed. After 6 months, the animals were sacrificed and the anastomoses were examined histologically. RESULTS: All animals survived at 6 months with 100% anastomosis patency rates in both groups. In the GraftConnector group, the anastomosis diameter at 6 months fluoroscopy was 118% of native left anterior descending artery versus 97% of the control group. Luminal anastomotic width at histology was 1.7 +/- 0.2 mm in the device group versus 1.6 +/- 0.1 mm in the control group. Mean intimal hyperplasia thickness was 0.21 +/- 0.1 mm in the device group versus 0.01 mm in the control group. CONCLUSIONS: The GraftConnector provides a consistent and reproducible coronary artery anastomosis and reduces technical demand and manual dexterity in coronary operations. Long-term results demonstrate that off-pump coronary artery bypass grafting performed with the GraftConnector had the same patency rate and luminal width as those performed with running suture.
Resumo:
Stress radiographs have been recommended in order to obtain a better objective quantification of abnormal compartment knee motion. This tool has showed to be superior in quantifying a posterior cruciate ligament (PCL) lesion compared to clinical or arthrometer evaluation. Different radiographic techniques have been described in literature to quantify posterior pathological laxity. In this study we evaluated the total amount of posterior displacement (PTD) and side to side difference (SSD), before and after surgical reconstruction of PCL or PCL and posterolateral complex (PLC), using two different stress radiography techniques (Telos stress and kneeling view). Twenty patients were included in this study. We found a statistical significant difference about both total PTD and SSD among the two techniques preoperatively and at follow-up, with greatest values occurring using the kneeling view. Although stress radiographies has been introduced to allow an objective quantification of laxity in ligamentous injured knee, we believe that further studies on a large numbers of subjects are required to define the relationship between PTD values, measured with stress knee radiography, particularly using kneeling view, and ligamentous knee injury, in order to obtain a real useful tool in the decision making process, as well as to evaluate the outcome after ligamentous surgery.
Resumo:
Retrograde or combined retrograde and antegrade recanalization should be considered when antegrade recanalization has failed in selected patients with critical limb ischemia (CLI). Retrograde recanalization is typically attempted through a patent segment of the popliteal artery or an infrapopliteal artery. The challenge arises, however, when there are no patent popliteal or infrapopliteal arteries suitable for retrograde access.