17 resultados para volumetric shrinkage
em Consorci de Serveis Universitaris de Catalunya (CSUC), Spain
Resumo:
Background Accurate automatic segmentation of the caudate nucleus in magnetic resonance images (MRI) of the brain is of great interest in the analysis of developmental disorders. Segmentation methods based on a single atlas or on multiple atlases have been shown to suitably localize caudate structure. However, the atlas prior information may not represent the structure of interest correctly. It may therefore be useful to introduce a more flexible technique for accurate segmentations. Method We present Cau-dateCut: a new fully-automatic method of segmenting the caudate nucleus in MRI. CaudateCut combines an atlas-based segmentation strategy with the Graph Cut energy-minimization framework. We adapt the Graph Cut model to make it suitable for segmenting small, low-contrast structures, such as the caudate nucleus, by defining new energy function data and boundary potentials. In particular, we exploit information concerning the intensity and geometry, and we add supervised energies based on contextual brain structures. Furthermore, we reinforce boundary detection using a new multi-scale edgeness measure. Results We apply the novel CaudateCut method to the segmentation of the caudate nucleus to a new set of 39 pediatric attention-deficit/hyperactivity disorder (ADHD) patients and 40 control children, as well as to a public database of 18 subjects. We evaluate the quality of the segmentation using several volumetric and voxel by voxel measures. Our results show improved performance in terms of segmentation compared to state-of-the-art approaches, obtaining a mean overlap of 80.75%. Moreover, we present a quantitative volumetric analysis of caudate abnormalities in pediatric ADHD, the results of which show strong correlation with expert manual analysis. Conclusion CaudateCut generates segmentation results that are comparable to gold-standard segmentations and which are reliable in the analysis of differentiating neuroanatomical abnormalities between healthy controls and pediatric ADHD.
Resumo:
Estudi elaborat a partir d’una estada a la Universitat Nacional de Yokohama des de maig fins a mitjans de juny del 2006. S'ha estudiat el comportament fàssic i la preparació de sílica mesoporosa pels nous tensioactius fluorats d'estructura C8F17SO2(C3H7)N(C2H4O)nH (abreujat C8F17(EO)n. El tensioactiu C8F17(EO)n forma micel•les allargades i cristalls líquids en aigua, i per tant pot ser adequat per a la preparació de materials mesoporosos. Sílica mesoestructurada es va preparar pel mètode de precipitació per autoagregació cooperativa. Un estudi sistemàtic es va realitzar, investigant la influència de les concentracions de tensioactiu i precursor (TEOS), l’efecte del pH i de la longitud de cadena de poliòxid d’etilè. Els materials es van caracteritzar per raigs X a angle petit (SAXS), sorció de nitrògen i TEM. Els materials obtinguts presenten diàmetres de por petits i parets de por gruixudes. A més, aquests materials posseeixen altes superfícies específiques, que s’han obtingut emprant concentracions de tensioactiu petites, produint parets de por robustes sense microporositat significativa. La superfície específica es manté durant el procés de calcinació, malgrat un petit encongiment degut a l’entrecreuament de la sílica. Els materials de sílica obtinguts han mostrat ser significativament més robustos que altres materials similars descrits a la bibliografia, com la sílica MCM-41.
Resumo:
The central message of this paper is that nobody should be using the samplecovariance matrix for the purpose of portfolio optimization. It containsestimation error of the kind most likely to perturb a mean-varianceoptimizer. In its place, we suggest using the matrix obtained from thesample covariance matrix through a transformation called shrinkage. Thistends to pull the most extreme coefficients towards more central values,thereby systematically reducing estimation error where it matters most.Statistically, the challenge is to know the optimal shrinkage intensity,and we give the formula for that. Without changing any other step in theportfolio optimization process, we show on actual stock market data thatshrinkage reduces tracking error relative to a benchmark index, andsubstantially increases the realized information ratio of the activeportfolio manager.
Resumo:
This paper proposes to estimate the covariance matrix of stock returnsby an optimally weighted average of two existing estimators: the samplecovariance matrix and single-index covariance matrix. This method isgenerally known as shrinkage, and it is standard in decision theory andin empirical Bayesian statistics. Our shrinkage estimator can be seenas a way to account for extra-market covariance without having to specifyan arbitrary multi-factor structure. For NYSE and AMEX stock returns from1972 to 1995, it can be used to select portfolios with significantly lowerout-of-sample variance than a set of existing estimators, includingmulti-factor models.
Resumo:
A class of composite estimators of small area quantities that exploit spatial (distancerelated)similarity is derived. It is based on a distribution-free model for the areas, but theestimators are aimed to have optimal design-based properties. Composition is applied alsoto estimate some of the global parameters on which the small area estimators depend.It is shown that the commonly adopted assumption of random effects is not necessaryfor exploiting the similarity of the districts (borrowing strength across the districts). Themethods are applied in the estimation of the mean household sizes and the proportions ofsingle-member households in the counties (comarcas) of Catalonia. The simplest version ofthe estimators is more efficient than the established alternatives, even though the extentof spatial similarity is quite modest.
Resumo:
New location models are presented here for exploring the reduction of facilities in aregion. The first of these models considers firms ceding market share to competitorsunder situations of financial exigency. The goal of this model is to cede the leastmarket share, i.e., retain as much of the customer base as possible while sheddingcostly outlets. The second model considers a firm essentially without competition thatmust shrink it services for economic reasons. This firm is assumed to close outlets sothat the degradation of service is limited. An example is offered within a competitiveenvironment to demonstrate the usefulness of this modeling approach.
Resumo:
Monitoring thunderstorms activity is an essential part of operational weather surveillance given their potential hazards, including lightning, hail, heavy rainfall, strong winds or even tornadoes. This study has two main objectives: firstly, the description of a methodology, based on radar and total lightning data to characterise thunderstorms in real-time; secondly, the application of this methodology to 66 thunderstorms that affected Catalonia (NE Spain) in the summer of 2006. An object-oriented tracking procedure is employed, where different observation data types generate four different types of objects (radar 1-km CAPPI reflectivity composites, radar reflectivity volumetric data, cloud-to-ground lightning data and intra-cloud lightning data). In the framework proposed, these objects are the building blocks of a higher level object, the thunderstorm. The methodology is demonstrated with a dataset of thunderstorms whose main characteristics, along the complete life cycle of the convective structures (development, maturity and dissipation), are described statistically. The development and dissipation stages present similar durations in most cases examined. On the contrary, the duration of the maturity phase is much more variable and related to the thunderstorm intensity, defined here in terms of lightning flash rate. Most of the activity of IC and CG flashes is registered in the maturity stage. In the development stage little CG flashes are observed (2% to 5%), while for the dissipation phase is possible to observe a few more CG flashes (10% to 15%). Additionally, a selection of thunderstorms is used to examine general life cycle patterns, obtained from the analysis of normalized (with respect to thunderstorm total duration and maximum value of variables considered) thunderstorm parameters. Among other findings, the study indicates that the normalized duration of the three stages of thunderstorm life cycle is similar in most thunderstorms, with the longest duration corresponding to the maturity stage (approximately 80% of the total time).
Resumo:
In this paper, we present a computer simulation study of the ion binding process at an ionizable surface using a semi-grand canonical Monte Carlo method that models the surface as a discrete distribution of charged and neutral functional groups in equilibrium with explicit ions modelled in the context of the primitive model. The parameters of the simulation model were tuned and checked by comparison with experimental titrations of carboxylated latex particles in the presence of different ionic strengths of monovalent ions. The titration of these particles was analysed by calculating the degree of dissociation of the latex functional groups vs. pH curves at different background salt concentrations. As the charge of the titrated surface changes during the simulation, a procedure to keep the electroneutrality of the system is required. Here, two approaches are used with the choice depending on the ion selected to maintain electroneutrality: counterion or coion procedures. We compare and discuss the difference between the procedures. The simulations also provided a microscopic description of the electrostatic double layer (EDL) structure as a function of p H and ionic strength. The results allow us to quantify the effect of the size of the background salt ions and of the surface functional groups on the degree of dissociation. The non-homogeneous structure of the EDL was revealed by plotting the counterion density profiles around charged and neutral surface functional groups.
Resumo:
Purpose: To assess the feasibility of a method based on microwave spectrometry to detect structural distortions of metallic stents in open air conditions and envisage the prospects of this approach toward possible medical applicability for the evaluation of implanted stents. Methods: Microwave absorbance spectra between 2.0 and 18.0 GHz were acquired in open air for the characterization of a set of commercial stents using a specifically design setup. Rotating each sample over 360º, 2D absorbance diagrams were generated as a function of frequency and rotation angle. To check our approach for detecting changes in stent length (fracture) and diameter (recoil), two specific tests were performed in open air. Finally, with a few adjustments, this same system provides 2D absorbance diagrams of stents immersed in a water-based phantom, this time over a bandwidth ranging from 0.2 to 1.8 GHz. Results: The authors show that metallic stents exhibit characteristic resonant frequencies in their microwave absorbance spectra in open air which depend on their length and, as a result, may reflect the occurrence of structural distortions. These resonances can be understood considering that such devices behave like dipole antennas in terms of microwave scattering. From fracture tests, the authors infer that microwave spectrometry provides signs of presence of Type I to Type IV stent fractures and allows in particular a quantitative evaluation of Type III and Type IV fractures. Recoil tests show that microwave spectrometry seems able to provide some quantitative assessment of diametrical shrinkage, but only if it involves longitudinal shortening. Finally, the authors observe that the resonant frequencies of stents placed inside the phantom shift down with respect to the corresponding open air frequencies, as it should be expected considering the increase of dielectric permittivity from air to water. Conclusions: The evaluation of stent resonant frequencies provided by microwave spectrometry allows detection and some quantitative assessment of stent fracture and recoil in open air conditions. Resonances of stents immersed in water can be also detected and their characteristic frequencies are in good agreement with theoretical estimates. Although these are promising results, further verifica tion in a more relevant phantom is required in order to foresee the real potential of this approach.
Resumo:
El objetivo de este trabajo fue el de evaluar la deposición transversal de caldo de las boquillas pulverizadoras de doble abanico TTJ60-11004 y TTJ60-11002 en distintas condiciones operacionales. Se utilizaron 5 muestras de cada boquilla pulverizadora siendo considerada cada unidad, una repetición. La distribución de caldo fue evaluada por medio de una mesa de evaluación de distribución construida de acuerdo con la norma ISO 56821. Se evaluó el perfil de distribución individual, la distribución volumétrica simulada de la superposición de los chorros por medio del coeficiente de variación (CV%) de los volúmenes colectados, el caudal y el ángulo de abertura de los chorros. Las condiciones operacionales fueron: presión de trabajo de 200, 300 y 400 Kpa, altura de 30, 40 y 50 cm en relación al blanco y espaciamiento entre boquillas simulados en Software (Microsoft Excel) entre 45 y 100 cm. Las boquillas presentaron perfil individual descontinuo con la mayor deposición de líquido en la región central y reducción del volumen gradual en dirección a las extremidades. El aumento de la presión promovió alargamiento del perfil y de la franja de aplicación. Las boquillas proporcionaron perfil uniforme que dependió del espaciamiento entre las boquillas, con valores menores con reducción en el espaciamiento y en presiones mayores. El caudal y el ángulo del chorro aumentaron con el incremento en la presión.
Resumo:
Objetivou-se neste trabalho avaliar a distribuição volumétrica e o espectro de gotas das pontas de pulverização de baixa deriva TTI110015, AI110015 e AVI11001 sob diferentes condições operacionais. A distribuição volumétrica foi determinada em bancada de ensaios padronizada analisando o coeficiente de variação (CV%) de uma barra simulada em computador, utilizando pressões de 200, 300 e 400 kPa, altura de 30, 40 e 50 cm em relação à bancada e espaçamento entre pontas de 40 a 100 cm. O espectro de gotas foi produzido utilizando-se apenas água como calda em um analisador de partículas em meio aquoso, nas pressões de 200, 300 e 400 kPa. Foram avaliados o DMV, a porcentagem de gotas com diâmetro inferior a 100 µm (%100 µm) e a amplitude relativa (AR). As pontas proporcionaram perfil descontínuo nas pressões de 300 e 400 kPa e uniforme a 200 kPa. Na pressão de 200 kPa, as pontas foram adequadas apenas para aplicação em faixa, e a 300 e 400 kPa, apenas para área total. Ocorreu menor CV (abaixo de 7%) com a maior pressão de trabalho e menor espaçamento entre pontas. À medida que se aumentou a pressão de trabalho, reduziu-se o DMV. As pontas TTI110015 e AI110015 em todas as pressões e a ponta AVI11001 na pressão de 200 kPa produziram gotas extremamente grossas e gotas grossas nas pressões de 300 e 400 kPa apenas para a ponta AVI11001. As pontas proporcionaram baixos valores de amplitude relativa (AR) e gotas de tamanho uniforme, bem como produziram baixa porcentagem de gotas menores que 100 µm, principalmente TTI110015 e AI110015, com menor risco de deriva.
Resumo:
Thereis now growing evidencethatthe hippocampus generatestheta rhythmsthat can phase biasfast neural oscillationsinthe neocortex, allowing coordination of widespread fast oscillatory populations outside limbic areas. A recent magnetoencephalographic study showed that maintenance of configural-relational scene information in a delayed match-to-sample (DMS) task was associated with replay of that information during the delay period. The periodicity of the replay was coordinated by the phase of the ongoing theta rhythm, and the degree of theta coordination during the delay period was positively correlated with DMS performance. Here, we reanalyzed these data to investigate which brain regions were involved in generating the theta oscillations that coordinated the periodic replay of configural- relational information. We used a beamformer algorithm to produce estimates of regional theta rhythms and constructed volumetric images of the phase-locking between the local theta cycle and the instances of replay (in the 13- 80 Hz band). We found that individual differences in DMS performancefor configural-relational associations were relatedtothe degree of phase coupling of instances of cortical reactivations to theta oscillations generated in the right posterior hippocampus and the right inferior frontal gyrus. This demonstrates that the timing of memory reactivations in humans is biased toward hippocampal theta phase
Resumo:
Introduction: Germline variants in TP63 have been consistently associated with several tumors, including bladder cancer, indicating the importance of TP53 pathway in cancer genetic susceptibility. However, variants in other related genes, including TP53 rs1042522 (Arg72Pro), still present controversial results. We carried out an in depth assessment of associations between common germline variants in the TP53 pathway and bladder cancer risk. Material and Methods: We investigated 184 tagSNPs from 18 genes in 1,058 cases and 1,138 controls from the Spanish Bladder Cancer/EPICURO Study. Cases were newly-diagnosed bladder cancer patients during 1998–2001. Hospital controls were age-gender, and area matched to cases. SNPs were genotyped in blood DNA using Illumina Golden Gate and TaqMan assays. Cases were subphenotyped according to stage/grade and tumor p53 expression. We applied classical tests to assess individual SNP associations and the Least Absolute Shrinkage and Selection Operator (LASSO)-penalized logistic regression analysis to assess multiple SNPs simultaneously. Results: Based on classical analyses, SNPs in BAK1 (1), IGF1R (5), P53AIP1 (1), PMAIP1 (2), SERINPB5 (3), TP63 (3), and TP73 (1) showed significant associations at p-value#0.05. However, no evidence of association, either with overall risk or with specific disease subtypes, was observed after correction for multiple testing (p-value$0.8). LASSO selected the SNP rs6567355 in SERPINB5 with 83% of reproducibility. This SNP provided an OR = 1.21, 95%CI 1.05–1.38, p-value = 0.006, and a corrected p-value = 0.5 when controlling for over-estimation. Discussion: We found no strong evidence that common variants in the TP53 pathway are associated with bladder cancer susceptibility. Our study suggests that it is unlikely that TP53 Arg72Pro is implicated in the UCB in white Europeans. SERPINB5 and TP63 variation deserve further exploration in extended studies.
Resumo:
Purpose: To assess the feasibility of a method based on microwave spectrometry to detect structural distortions of metallic stents in open air conditions and envisage the prospects of this approach toward possible medical applicability for the evaluation of implanted stents. Methods: Microwave absorbance spectra between 2.0 and 18.0 GHz were acquired in open air for the characterization of a set of commercial stents using a specifically design setup. Rotating each sample over 360º, 2D absorbance diagrams were generated as a function of frequency and rotation angle. To check our approach for detecting changes in stent length (fracture) and diameter (recoil), two specific tests were performed in open air. Finally, with a few adjustments, this same system provides 2D absorbance diagrams of stents immersed in a water-based phantom, this time over a bandwidth ranging from 0.2 to 1.8 GHz. Results: The authors show that metallic stents exhibit characteristic resonant frequencies in their microwave absorbance spectra in open air which depend on their length and, as a result, may reflect the occurrence of structural distortions. These resonances can be understood considering that such devices behave like dipole antennas in terms of microwave scattering. From fracture tests, the authors infer that microwave spectrometry provides signs of presence of Type I to Type IV stent fractures and allows in particular a quantitative evaluation of Type III and Type IV fractures. Recoil tests show that microwave spectrometry seems able to provide some quantitative assessment of diametrical shrinkage, but only if it involves longitudinal shortening. Finally, the authors observe that the resonant frequencies of stents placed inside the phantom shift down with respect to the corresponding open air frequencies, as it should be expected considering the increase of dielectric permittivity from air to water. Conclusions: The evaluation of stent resonant frequencies provided by microwave spectrometry allows detection and some quantitative assessment of stent fracture and recoil in open air conditions. Resonances of stents immersed in water can be also detected and their characteristic frequencies are in good agreement with theoretical estimates. Although these are promising results, further verifica tion in a more relevant phantom is required in order to foresee the real potential of this approach.
Resumo:
Language diversity has become greatly endangered in the past centuries owing to processes of language shift from indigenous languages to other languages that are seen as socially and economically more advantageous, resulting in the death or doom of minority languages. In this paper, we define a new language competition model that can describe the historical decline of minority languages in competition with more advantageous languages. We then implement this non-spatial model as an interaction term in a reactiondiffusion system to model the evolution of the two competing languages. We use the results to estimate the speed at which the more advantageous language spreads geographically, resulting in the shrinkage of the area of dominance of the minority language. We compare the results from our model with the observed retreat in the area of influence of the Welsh language in the UK, obtaining a good agreement between the model and the observed data