43 resultados para solid fuel
em Consorci de Serveis Universitaris de Catalunya (CSUC), Spain
Resumo:
GdBaCo2O5+x (GBCO) was evaluated as a cathode for intermediate-temperature solid oxide fuel cells. A porous layer of GBCO was deposited on an anode-supported fuel cell consisting of a 15m thick electrolyte of yttria-stabilized zirconia (YSZ) prepared by dense screen-printing anda Ni–YSZ cermet as an anode (Ni–YSZ/YSZ/GBCO). Values of power density of 150 mW cm−2 at 700◦C and ca. 250 mW cm−2 at 800◦C are reported for this standard configuration using 5% of H2 in nitrogen as fuel. An intermediate porous layer of YSZ was introduced between the electrolyte and the cathode improving the performance of the cell. Values for power density of 300 mW cm−2 at 700◦C and ca. 500 mW cm−2 at 800◦C in this configuration were achieved.
Resumo:
We derive analytical expressions for the propagation speed of downward combustion fronts of thin solid fuels with a background flow initially at rest. The classical combustion model for thin solid fuels that consists of five coupled reaction-convection-diffusion equations is here reduced into a single equation with the gas temperature as the single variable. For doing so we apply a two-zone combustion model that divides the system into a preheating region and a pyrolyzing region. The speed of the combustion front is obtained after matching the temperature and its derivative at the location that separates both regions.We also derive a simplified version of this analytical expression expected to be valid for a wide range of cases. Flame front velocities predicted by our analyticalexpressions agree well with experimental data found in the literature for a large variety of cases and substantially improve the results obtained from a previous well-known analytical expression
Resumo:
The main goal of this special issue was to gather contributions dealing with the latest breakthrough methods for providing value compounds and energy/fuel from waste valorization. Valorization is a relatively new approach in the area of industrial wastes management, a key issue to promote sustainable development. In this field, the recovery of value-added substances, such as antioxidants, proteins, vitamins, and so forth, from the processing of agroindustrial byproducts, is worth mentioning. Another important valorization approach is the use of biogas from waste treatment plants for the production of energy. Several approaches involving physical and chemical processes, thermal and biological processes that ensure reduced emissions and energy consumptions were taken into account. The papers selected for this topical issue represent some of the mostly researched methods that currently promote the valorization of wastes to energy and useful materials ...
Resumo:
Report for the scientific sojourn carried out at the Institut de Biologia Molecular de Barcelona of the CSIC –state agency – from april until september 2007. Topoisomerase I is an essential nuclear enzyme that modulates the topological status of DNA, facilitating DNA helix unwinding during replication and transcription. We have prepared the oligonucleotide-peptide conjugate Ac-NLeu-Asn-Tyr(p-3’TTCAGAAGC5’)-LeuC-CONH-(CH2)6-OH as model compound for NMR studies of the Topoisomerase I- DNA complex. Special attention was made on the synthetic aspects for the preparation of this challenging compound especially solid supports and protecting groups. The desired peptide was obtained although we did not achieve the amount of the conjugate needed for NMR studies. Most probably the low yield is due to the intrinsic sensitive to hydrolysis of the phosphate bond between oligonucleotide and tyrosine. We have started the synthesis and the structural characterization of oligonucleotides carrying intercalating compounds. At the present state we have obtained model duplex and quadruplex sequences modified with acridine and NMR studies are underway. In addition to this project we have successfully resolved the structure of a fusion peptide derived from hepatitis C virus envelope synthesized by the group of Dr. Haro and we have synthesized and started the characterization of a modified G-quadruplex.
Resumo:
En este proyecto se tiene como objetivo comparar una EDAR específica con otras tres, desde el punto de vista ambiental, y establecer diferentes alternativas. En particular, se ha evaluado la mejor alternativa en la obtención de energía eléctrica para la propia utilización de la planta de tratamiento de aguas residuales, a partir del biogás generado en el digestor en la línea de lodos. En este tipo de instalaciones, entre las alternativas tanto en su uso actual como en fase de desarrollo, el motor de cogeneración de electricidad y el calor es el más utilizado para obtener simultáneamente la electricidad necesaria para las instalaciones y el calor necesario para mantener el digestor de lodos a la temperatura de trabajo (36ºC aproximadamente). Las otras alternativas evaluadas en este estudio son las pilas de biogás de membrana electrolítica polimérica (en inglés Polymeric Electrolyte Membrane, PEM) y las pilas de óxidos sólidos (en inglés Solid Oxide Fuel Cells, SOFC) con una turbina de gas (sistema híbrido SOFC-GT). Por otro lado, se estudian las características de los materiales que componen los dispositivos MEC (microbial electrolysis cell) y las pilas PEM y SOFC, así como las ventajas e inconvenientes de usar estas nuevas tecnologías en el tratamiento de aguas residuales, así como la evaluación del impacto ambiental de la EDAR objeto de estudio, que se ha llevado a cabo utilizando el análisis de ciclo de vida (ACV). El ACV es una herramienta que permite comparar diferentes procesos o productos que tengan la misma función, y así evaluar la alternativa que conlleve una mejora en el medio ambiental. La metodología de ACV pretende evaluar en detalle el ciclo de vida completo de un producto o proceso. Un ACV se suele definir de tipo "cradle to grave" o "desde la cuna hasta la tumba" o bien de tipo "gate to gate", o "de puerta a puerta". En el primer caso el estudio analiza el ciclo de vida completo del sistema, dese el origen hasta el final, mientras que en el segundo caso el ACV no tiene en cuenta su disposición final (vertedero, reciclaje, etc.). Un estudio de ACV del primer tipo conlleva hacer un estudio muy detallado, que en la práctica puede resultar muy largo y laborioso por la dificultad de encontrar todos los datos necesarios. Por ello, muchos estudios de ACV que se encuentran en la literatura suelen ser del tipo "gate to gate". Además, hay que esablecer las fronteras del sistema a estudiar, ya que hay procesos que tienen muy poca contribución a las categorías de impacto ambiental. En una EDAR los principales procesos considerados en el ACV llevado a cabo son el consumo de productos químicos, de electricidad, la producción de lodos y su utilización como composta, el biogás y su utilización para producir electricidad, los residuos sólidos y las distintas emisiones al medio producidas por el propio funcionamiento de la EDAR. Las operaciones relacionadas indirectamente como el transporte de los lodos, de productos químicos, de los residuos sólidos y la infraestructura con una vida media de 30 años no influyen significativamente en los resultados, por ejemplo el transporte de los lodos con un camión a 30km contribuyen en menos de 1% en todas las categorías de impacto. De acuerdo con las normativas ISO series 14040 que regulan las pautas de un ACV, se establece una unidad funcional apropiada, o sea habitante equivalente, ya que es la más apropiada por tener en cuenta la carga contaminante en el agua a tratar, parámetro imprescindible para comparar EDARs. Redefiniendo las fronteras, se realiza un ACV del depósito del biogás sin tener en cuenta el resto de la instalación y se toma como unidad funcional m3 de biogás, en el caso concreto de obtener biogás mediante un dispositivo MEC, que maximiza la cantidad de hidrógeno en detrimento de la cantidad de metano contenido en el biogás, observándose que la contribución de un biogás con un alto contenido en hidrógeno y, por tanto bajo en metano, produce una mejora ambiental. Las categorías de impacto ambiental que tienen contribución son el calentamiento global y la oxidación fotoquímica; el dispositivo MEC hace quela contribución a estas categorías de impacto sea de un orden de magnitud inferior con respecto al biogás generado en un digestor. Además, si se produce la combustión del biogás, la única categoría de impacto que tiene contribución es la de calentamiento global; para una dispositivo MEC la contribución sigue siendo un orden de magnitud inferior con respecto al biogás de un digestor de lodos.
Resumo:
The Great Tohoku-Kanto earthquake and resulting tsunami has brought considerable attention to the issue of the construction of new power plants. We argue in this paper, nuclear power is not a sustainable solution to energy problems. First, we explore the stock of uranium-235 and the different schemes developed by the nuclear power industry to exploit this resource. Second, we show that these methods, fast breeder and MOX fuel reactors, are not feasible. Third, we show that the argument that nuclear energy can be used to reduce CO2 emissions is false: the emissions from the increased water evaporation from nuclear power generation must be accounted for. In the case of Japan, water from nuclear power plants is drained into the surrounding sea, raising the water temperature which has an adverse affect on the immediate ecosystem, as well as increasing CO2 emissions from increased water evaporation from the sea. Next, a short exercise is used to show that nuclear power is not even needed to meet consumer demand in Japan. Such an exercise should be performed for any country considering the construction of additional nuclear power plants. Lastly, the paper is concluded with a discussion of the implications of our findings.
Resumo:
L’aigua i l’energia formen un binomi indissociable. En relació al cicle de l’aigua, des de fa varies dècades s’han desenvolupat diferents formes per recuperar part de l’energia relacionada amb l’aigua, per exemple a partir de centrals hidroelèctriques. No obstant, l’ús d’aquesta aigua també porta associat un gran consum energètic, relacionat sobretot amb el transport, la distribució, la depuració, etc... La depuració d’aigües residuals porta associada una elevada demanda energètica (Obis et al.,2009). En termes energètics, tot i que la despesa elèctrica d’una EDAR varia en funció de diferents paràmetres com la configuració i la capacitat de la planta, la càrrega a tractar, etc... es podria considerar que el rati mig seria d’ aproximadament 0.5 KWh•m-3.Els principals costos d’explotació estan relacionats tant amb la gestió de fangs (28%) com amb el consum elèctric (25%) (50% tractament biològic). Tot i que moltes investigacions relacionades amb el tractament d’aigua residual estan encaminades en disminuir els costos d’operació, des de fa poques dècades s’està investigant la viabilitat de que l’aigua residual fins i tot sigui una font d’energia, canviant la perspectiva, i començant a veure l’aigua residual no com a una problemàtica sinó com a un recurs. Concretament s’estima que l’aigua domèstica conté 9.3 vegades més energia que la necessària per el seu tractament mitjançant processos aerobis (Shizas et al., 2004). Un dels processos més desenvolupats relacionats amb el tractament d’aigües residuals i la producció energètica és la digestió anaeròbia. No obstant, aquesta tecnologia permet el tractament d’altes càrregues de matèria orgànica generant un efluent ric en nitrogen que s’haurà de tractar amb altres tecnologies. Per altre banda, recentment s’està investigant una nova tecnologia relacionada amb el tractament d’aigües residuals i la producció energètica: les piles biològiques (microbial fuel cells, MFC). Aquesta tecnologia permet obtenir directament energia elèctrica a partir de la degradació de substrats biodegradables (Rabaey et al., 2005). Les piles biològiques, més conegudes com a Microbial Fuel Cells (acrònim en anglès, MFC), són una emergent tecnologia que està centrant moltes mirades en el camp de l’ investigació, i que es basa en la producció d’energia elèctrica a partir de substrats biodegradables presents en l’aigua residual (Logan., 2008). Els fonaments de les piles biològiques és molt semblant al funcionament d’una pila Daniell, en la qual es separa en dos compartiments la reacció d’oxidació (compartiment anòdic) i la de reducció (compartiment catòdic) amb l’objectiu de generar un determinat corrent elèctric. En aquest estudi, bàsicament es mostra la posada en marxa d'una pila biològica per a l'eliminació de matèria orgànica i nitrogen de les aigües residuals.
Resumo:
The aim of this study was to describe the clinical characteristics of pandemic influenza A H1N1 infection. A retrospective study was performed in pediatric patients with solid organ transplantation and confirmed influenza A H1N1/2009 infection from June to December 2009, diagnosed in two Spanish teaching. Forty-nine patients were included. Pneumonia was diagnosed in 4 patients (8.2%), and 3 of them required respiratory support. There were no related deaths. Antiviral treatment within 48 hours was associated with a lower likelihood of pneumonia (0/38, 0%) than treatment started after 48 hours (4/11, 36.3%) (p&0.01).
Resumo:
The subject of this project is about “Energy Dispersive X-Ray Fluorescence ” (EDXRF).This technique can be used for a tremendous variety of elemental analysis applications.It provides one of the simplest, most accurate and most economic analytical methods for thedetermination of the chemical composition of many types of materials.The purposes of this project are:- To give some basic information about Energy Dispersive X-ray Fluorescence.- To perform qualitative and quantitative analysis of different samples (water-dissolutions,powders, oils,..) in order to define the sensitivity and detection limits of the equipment.- To make a comprehensive and easy-to-use manual of the ‘ARL QUANT’X EnergyDispersive X-Ray Fluorescence’ apparatus
Resumo:
Accomplish high quality of final products in pharmaceutical industry is a challenge that requires the control and supervision of all the manufacturing steps. This request created the necessity of developing fast and accurate analytical methods. Near infrared spectroscopy together with chemometrics, fulfill this growing demand. The high speed providing relevant information and the versatility of its application to different types of samples lead these combined techniques as one of the most appropriated. This study is focused on the development of a calibration model able to determine amounts of API from industrial granulates using NIR, chemometrics and process spectra methodology.
Resumo:
Two concentration methods for fast and routine determination of caffeine (using HPLC-UV detection) in surface, and wastewater are evaluated. Both methods are based on solid-phase extraction (SPE) concentration with octadecyl silica sorbents. A common “offline” SPE procedure shows that quantitative recovery of caffeine is obtained with 2 mL of an elution mixture solvent methanol-water containing at least 60% methanol. The method detection limit is 0.1 μg L−1 when percolating 1 L samples through the cartridge. The development of an “online” SPE method based on a mini-SPE column, containing 100 mg of the same sorbent, directly connected to the HPLC system allows the method detection limit to be decreased to 10 ng L−1 with a sample volume of 100 mL. The “offline” SPE method is applied to the analysis of caffeine in wastewater samples, whereas the “on-line” method is used for analysis in natural waters from streams receiving significant water intakes from local wastewater treatment plants
Resumo:
The results of a crystal structure refinement of an anisotropic grandite garnet specimen with composition Gro36-4 And63-6 are given. The structure obtained has orthorrombic symmetry (space group Fddd) and is compared with similar results obtained by other authors. In all cases the reduction of symmetry is due to the ordering of Fe3+ and Al in octahedral sites. Non cubic structures of grandites are discussed in connection with optical, morphological an grou-th features of these minerals.
Resumo:
X-ray diffraction analyses of the pure components n-tricosane and n-pentacosane and of their binary mixed samples have enabled us to characterize the crystalline phases observed at low temperature. On the contrary to what was announced in literature on the structural behavior of mixed samples in odd-odd binary systems with D n = 2, the three domains are not all orthorhombic. This work has enabled us to show that two of the domains are, in fact, monoclinic, (Aa, Z = 4) and the other one is orthorhombic (Pca21, Z = 4). The conclusions drawn in this work can be easily transposed to other binary systems of n-alkanes.
Resumo:
In this paper we analyse some of the organisational aspects of the urban solid waste collection and, in particular, the privatization modality of contracting out. We start by discussing some of the theoretical aspects of contracting out. We then specify and estimate an explanatory model on a sample of municipalities that we surveyed. Our purpose is twofold: on the one hand, we identify the economic factors at work when deciding to contract out the service and, on the other hand, we analyse the role of ideological factors in choosing between the public production of the service or contracting it out. The results show a significant effect of the demand for waste collection on contracting out. There also appears to be a neighbouring effect as the municipalities close to other cities that contract out are also more prone to do so. Finally, the decisions to contract seem to have been motivated by pragmatic rather than ideological reasons.
Resumo:
A surface dielectric function of a semi-infinite plane-bounded metal is defined in the spirit of the plasmon-pole dielectric function of the bulk. It is modeled in such a way that the surface-plasmon dispersion relation is recovered for small momentum transfer. This function is employed to compute the image potential at all distances outside the surface. Interaction with bulk modes is neglected for simplicity and clarity. The interaction of a massive point charge with a metal surface is also considered in the context of a boson model for surface-plasmon excitation. We present a new definition of the image potential for this case.