21 resultados para retinal contour

em Consorci de Serveis Universitaris de Catalunya (CSUC), Spain


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a method to achieve the most relevant contours of an image. The presented method proposes to integrate the information of the local contours from chromatic components such as H, S and I, taking into account the criteria of coherence of the local contour orientation values obtained from each of these components. The process is based on parametrizing pixel by pixel the local contours (magnitude and orientation values) from the H, S and I images. This process is carried out individually for each chromatic component. If the criterion of dispersion of the obtained orientation values is high, this chromatic component will lose relevance. A final processing integrates the extracted contours of the three chromatic components, generating the so-called integrated contours image

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In image segmentation, clustering algorithms are very popular because they are intuitive and, some of them, easy to implement. For instance, the k-means is one of the most used in the literature, and many authors successfully compare their new proposal with the results achieved by the k-means. However, it is well known that clustering image segmentation has many problems. For instance, the number of regions of the image has to be known a priori, as well as different initial seed placement (initial clusters) could produce different segmentation results. Most of these algorithms could be slightly improved by considering the coordinates of the image as features in the clustering process (to take spatial region information into account). In this paper we propose a significant improvement of clustering algorithms for image segmentation. The method is qualitatively and quantitative evaluated over a set of synthetic and real images, and compared with classical clustering approaches. Results demonstrate the validity of this new approach

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The human CERKL gene is responsible for common and severe forms of retinal dystrophies. Despite intense in vitro studies at the molecular and cellular level and in vivo analyses of the retina of murine knockout models, CERKL function remains unknown. In this study, we aimed to approach the developmental and functional features of cerkl in Danio rerio within an Evo-Devo framework. We show that gene expression increases from early developmental stages until the formation of the retina in the optic cup. Unlike the high mRNA-CERKL isoform multiplicity shown in mammals, the moderate transcriptional complexity in fish facilitates phenotypic studies derived from gene silencing. Moreover, of relevance to pathogenicity, teleost CERKL shares the two main human protein isoforms. Morpholino injection has been used to generate a cerkl knockdown zebrafish model. The morphant phenotype results in abnormal eye development with lamination defects, failure to develop photoreceptor outer segments, increased apoptosis of retinal cells and small eyes. Our data support that zebrafish Cerkl does not interfere with proliferation and neural differentiation during early developmental stages but is relevant for survival and protection of the retinal tissue. Overall, we propose that this zebrafish model is a powerful tool to unveil CERKL contribution to human retinal degeneration

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper the authors propose a new closed contour descriptor that could be seen as a Feature Extractor of closed contours based on the Discrete Hartley Transform (DHT), its main characteristic is that uses only half of the coefficients required by Elliptical Fourier Descriptors (EFD) to obtain a contour approximation with similar error measure. The proposed closed contour descriptor provides an excellent capability of information compression useful for a great number of AI applications. Moreover it can provide scale, position and rotation invariance, and last but not least it has the advantage that both the parameterization and the reconstructed shape from the compressed set can be computed very efficiently by the fast Discrete Hartley Transform (DHT) algorithm. This Feature Extractor could be useful when the application claims for reversible features and when the user needs and easy measure of the quality for a given level of compression, scalable from low to very high quality.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Estudio elaborado a partir de una estancia en la Universidad de Rochester, Estados Unidos, de octubre del 2006 a enero del 2007. La estancia realizada en la Universidad de Rochester estuvo orientada al aprendizaje en profundidad del oftalmoscopio láser de barrido. El oftalmoscopio láser de barrido emplea una técnica confocal con la finalidad de visualizar diferentes estructuras retinianas en seres vivos. El instrumento diseñado y desarrollado en el Centro de Ciencias de la Visión incorpora un sistema de óptica adaptativa y fluorescencia. La óptica adaptativa aplicada en este oftalmoscopio tiene como objetivo corregir las aberraciones existentes en el ojo y así permitir observar detalles de la retina que de otra forma se verían emborronados. De esta forma se consigue alcanzar valores de resolución muy cercanos a los impuestos por difracción. Por otro lado el uso de fluorescencia tiene por objetivo el permitir la visualización de células y estructuras que, de no ser teñidas, son transparentes a la luz y visible. Esta técnica se ha estado utilizando principalmente en primates y ratas, aunque actualmente también se están llevando a cabo medidas de células de epitelio pigmentario en seres humanos ya que el pigmento contenido en estas células permite la aplicación de la fluorescencia sin necesidad de utilizar tinción.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

RESUM En aquest document es presenta un detector de contorns d’imatges basat en el domini transformat. A partir de la interpretació de la transformada de Fourier de la imatge i la seva formulació matricial en termes dels diferents modes, es realitza una selecció de les components passa baixes a partir de les quals es reconstrueix la component de baixa freqüència que es resta de la imatge original per tal d’obtenir el detector. Aquest detector de contorns no és esbiaixat. L’algorisme pot ser aplicat utilitzant diferents mides del bloc de processament, que pot anar de la imatge sencera a blocs de reduïdes dimensions: 36X36, 16x16 o 8x8, per fer un seguiment de les propietats locals de la imatge quan aquesta és presenta característiques espacials poc uniformes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Este trabajo presenta un sistema para detectar y clasificar objetos binarios según la forma de éstos. En el primer paso del procedimiento, se aplica un filtrado para extraer el contorno del objeto. Con la información de los puntos de forma se obtiene un descriptor BSM con características altamente descriptivas, universales e invariantes. En la segunda fase del sistema se aprende y se clasifica la información del descriptor mediante Adaboost y Códigos Correctores de Errores. Se han usado bases de datos públicas, tanto en escala de grises como en color, para validar la implementación del sistema diseñado. Además, el sistema emplea una interfaz interactiva en la que diferentes métodos de procesamiento de imágenes pueden ser aplicados.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectiu:Avaluar l’eficàcia i seguretat de pegaptanib de sodi en el tractament de l’edema macular secundari a obstrucció venosa de la retina (OVR). Mètode: Estudi prospectiu de 16 pacients amb edema macular secundari a OVR tractats mitjançant injeccions intravítrees de pegaptanib de sodi 1mg (0’05ml) a demanda amb un període de seguiment mínim de 6 mesos. Resultat: Millora significativa de l’agudesa visual i del perfil foveal en els nostres pacients. No alarmes de seguretat noves. Conclusions: Pegaptanib de sodi sembla proporcionar beneficis anatòmics i funcionals en el tractament de l’edema macular secundari a trombosis venosa de la retina.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Propósito: Determinar, en los pacientes afectados de desprendimiento de retina rhegmatógeno primario que acudieron a nuestro centro, el tiempo de demora entre la aparición de los primeros síntomas y la visita con el cirujano. Los objetivos secundarios son describir los factores que han influido en este tiempo de demora, determinar la relación existente entre el tiempo de evolución del desprendimiento rhegmatógeno de retina primario, el estado de la mácula y el resultado funcional tras la cirugía, y describir la sintomatología referida por los pacientes. Material y Método: Estudio descriptivo prospectivo de 59 ojos de 59 pacientes con desprendimiento de retina rhegmatógeno primario que acudieron al servicio de oftalmología del hospital Vall d’Hebron entre marzo y junio del 2008. Se realizó una anamnesis y exploración oftalmológica detallada a su llegada, fueron sometidos a cirugía mediante vitrectomía vía pars plana y se les realizó un seguimiento mínimo de 6 meses determinando los resultados funcionales de la cirugía. Resultados: El tiempo de demora medio desde la aparición de los síntomas hasta la primera consulta con el facultativo fue de 4,10 días. La media del tiempo de evolución del desprendimiento rhegmatógeno de retina fue de 17,03 días. Un 84,1% de los pacientes con la mácula desprendida tenían un tiempo de evolución menor o igual a 15 días y un 15,9% un tiempo de evolución mayor a 15 días. La agudeza visual media postoperatoria de los pacientes con la mácula aplicada fue de 0,55 en escala decimal, en los pacientes con la mácula afectada de menos de 15 días de evolución fue de 0,41, y en los pacientes con la mácula afectada de más de 15 días de evolución fue de 0,33. El síntoma más frecuente fue la visión borrosa (98,3%), seguido de miodesopsias (28,8%). Conclusiones: El tiempo de demora entre la aparición de los primeros síntomas del DRR y la visita con el cirujano es superior desde la remisión al cirujano por parte del facultativo que desde la aparición de síntomas y consulta con el facultativo por el paciente. La subestimación de la gravedad por parte del paciente es la causa de demora referida más frecuente. Los pacientes con un mayor tiempo de evolución tienen un mayor porcentaje de afectación macular. Los pacientes con la mácula aplicada han tenido un mejor resultado funcional tras la cirugía del DRR que los pacientes con la mácula desprendida.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The effect of basis set superposition error (BSSE) on molecular complexes is analyzed. The BSSE causes artificial delocalizations which modify the first order electron density. The mechanism of this effect is assessed for the hydrogen fluoride dimer with several basis sets. The BSSE-corrected first-order electron density is obtained using the chemical Hamiltonian approach versions of the Roothaan and Kohn-Sham equations. The corrected densities are compared to uncorrected densities based on the charge density critical points. Contour difference maps between BSSE-corrected and uncorrected densities on the molecular plane are also plotted to gain insight into the effects of BSSE correction on the electron density

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Report for the scientific sojourn carried out at the University Medical Center, Swiss, from 2010 to 2012. Abundant evidence suggests that negative emotional stimuli are prioritized in the perceptual systems, eliciting enhanced neural responses in early sensory regions as compared with neutral information. This facilitated detection is generally paralleled by larger neural responses in early sensory areas, relative to the processing of neutral information. In this sense, the amygdala and other limbic regions, such as the orbitofrontal cortex, may play a critical role by sending modulatory projections onto the sensory cortices via direct or indirect feedback.The present project aimed at investigating two important issues regarding these mechanisms of emotional attention, by means of functional magnetic resonance imaging. In Study I, we examined the modulatory effects of visual emotion signals on the processing of task-irrelevant visual, auditory, and somatosensory input, that is, the intramodal and crossmodal effects of emotional attention. We observed that brain responses to auditory and tactile stimulation were enhanced during the processing of visual emotional stimuli, as compared to neutral, in bilateral primary auditory and somatosensory cortices, respectively. However, brain responses to visual task-irrelevant stimulation were diminished in left primary and secondary visual cortices in the same conditions. The results also suggested the existence of a multimodal network associated with emotional attention, presumably involving mediofrontal, temporal and orbitofrontal regions Finally, Study II examined the different brain responses along the low-level visual pathways and limbic regions, as a function of the number of retinal spikes during visual emotional processing. The experiment used stimuli resulting from an algorithm that simulates how the visual system perceives a visual input after a given number of retinal spikes. The results validated the visual model in human subjects and suggested differential emotional responses in the amygdala and visual regions as a function of spike-levels. A list of publications resulting from work in the host laboratory is included in the report.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Report for the scientific sojourn carried out at the University Medical Center, Swiss, from 2010 to 2012. Abundant evidence suggests that negative emotional stimuli are prioritized in the perceptual systems, eliciting enhanced neural responses in early sensory regions as compared with neutral information. This facilitated detection is generally paralleled by larger neural responses in early sensory areas, relative to the processing of neutral information. In this sense, the amygdala and other limbic regions, such as the orbitofrontal cortex, may play a critical role by sending modulatory projections onto the sensory cortices via direct or indirect feedback.The present project aimed at investigating two important issues regarding these mechanisms of emotional attention, by means of functional magnetic resonance imaging. In Study I, we examined the modulatory effects of visual emotion signals on the processing of task-irrelevant visual, auditory, and somatosensory input, that is, the intramodal and crossmodal effects of emotional attention. We observed that brain responses to auditory and tactile stimulation were enhanced during the processing of visual emotional stimuli, as compared to neutral, in bilateral primary auditory and somatosensory cortices, respectively. However, brain responses to visual task-irrelevant stimulation were diminished in left primary and secondary visual cortices in the same conditions. The results also suggested the existence of a multimodal network associated with emotional attention, presumably involving mediofrontal, temporal and orbitofrontal regions Finally, Study II examined the different brain responses along the low-level visual pathways and limbic regions, as a function of the number of retinal spikes during visual emotional processing. The experiment used stimuli resulting from an algorithm that simulates how the visual system perceives a visual input after a given number of retinal spikes. The results validated the visual model in human subjects and suggested differential emotional responses in the amygdala and visual regions as a function of spike-levels. A list of publications resulting from work in the host laboratory is included in the report.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main information sources to study a particular piece of music are symbolic scores and audio recordings. These are complementary representations of the piece and it isvery useful to have a proper linking between the two of the musically meaningful events. For the case of makam music of Turkey, linking the available scores with the correspondingaudio recordings requires taking the specificities of this music into account, such as the particular tunings, the extensive usage of non-notated expressive elements, and the way in which the performer repeats fragmentsof the score. Moreover, for most of the pieces of the classical repertoire, there is no score written by the original composer. In this paper, we propose a methodology to pair sections of a score to the corresponding fragments of audio recording performances. The pitch information obtained from both sources is used as the common representationto be paired. From an audio recording, fundamental frequency estimation and tuning analysis is done to compute a pitch contour. From the corresponding score, symbolic note names and durations are converted to a syntheticpitch contour. Then, a linking operation is performed between these pitch contours in order to find the best correspondences.The method is tested on a dataset of 11 compositions spanning 44 audio recordings, which are mostly monophonic. An F3-score of 82% and 89% are obtained with automatic and semi-automatic karar detection respectively,showing that the methodology may give us a needed tool for further computational tasks such as form analysis, audio-score alignment and makam recognition.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Un dels principals problemes quan es realitza un anàlisi de contorns és la gran quantitat de dades implicades en la descripció de la figura. Per resoldre aquesta problemàtica, s’aplica la parametrització que consisteix en obtenir d’un contorn unes dades representatives amb els mínims coeficients possibles, a partir dels quals es podrà reconstruir de nou sense pèrdues molt evidents d’informació. En figures de contorns tancats, la parametrització més estudiada és l’aplicació de la transformada discreta de Fourier (DFT). Aquesta s’aplica a la seqüència de valors que descriu el comportament de les coordenades x i y al llarg de tots els punts que formen el traç. A diferència, en els contorns oberts no es pot aplicar directament la DFT ja que per fer-ho es necessita que el valor de x i de y siguin iguals tan en el primer punt del contorn com en l’últim. Això és degut al fet que la DFT representa sense error senyals periòdics. Si els senyals no acaben en el mateix punt, representa que hi ha una discontinuïtat i apareixen oscil·lacions a la reconstrucció. L’objectiu d’aquest treball és parametritzar contorns oberts amb la mateixa eficiència que s’obté en la parametrització de contorns tancats. Per dur-ho a terme, s’ha dissenyat un programa que permet aplicar la DFT en contorns oberts mitjançant la modificació de les seqüencies de x i y. A més a més, també utilitzant el programari Matlab s’han desenvolupat altres aplicacions que han permès veure diferents aspectes sobre la parametrització i com es comporten els Descriptors El·líptics de Fourier (EFD). Els resultats obtinguts han demostrat que l’aplicació dissenyada permet la parametrització de contorns oberts amb compressions òptimes, fet que facilitarà l’anàlisi quantitatiu de formes en camps com l’ecologia, medicina, geografia, entre d’altres.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coalescing compact binary systems are important sources of gravitational waves. Here we investigate the detectability of this gravitational radiation by the recently proposed laser interferometers. The spectral density of noise for various practicable configurations of the detector is also reviewed. This includes laser interferometers with delay lines and Fabry-Prot cavities in the arms, both in standard and dual recycling arrangements. The sensitivity of the detector in all those configurations is presented graphically and the signal-to-noise ratio is calculated numerically. For all configurations we find values of the detector's parameters which maximize the detectability of coalescing binaries, the discussion comprising Newtonian- as well as post-Newtonian-order effects. Contour plots of the signal-to-noise ratio are also presented in certain parameter domains which illustrate the interferometer's response to coalescing binary signals.