21 resultados para power system faults

em Consorci de Serveis Universitaris de Catalunya (CSUC), Spain


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Fault location has been studied deeply for transmission lines due to its importance in power systems. Nowadays the problem of fault location on distribution systems is receiving special attention mainly because of the power quality regulations. In this context, this paper presents an application software developed in Matlabtrade that automatically calculates the location of a fault in a distribution power system, starting from voltages and currents measured at the line terminal and the model of the distribution power system data. The application is based on a N-ary tree structure, which is suitable to be used in this application due to the highly branched and the non- homogeneity nature of the distribution systems, and has been developed for single-phase, two-phase, two-phase-to-ground, and three-phase faults. The implemented application is tested by using fault data in a real electrical distribution power system

Relevância:

80.00% 80.00%

Publicador:

Resumo:

En el perímetre del parc es troben gran nombre d’edificacions amb mancances de subministrament elèctric per la gran dispersió de la població de la comarca. L’objectiu d’aquest estudi és desenvolupar un protocol per determinar la viabilitat de l’energia fotovoltaica en edificis aïllats i aplicar-la de forma pilot a dos edificis gestionats pels responsables del Parc Natural de l’Alt Pirineu: el Centre de Logística i Manteniment (CLM) i el Refugi del Fornet. Aquests han estat escollits per la seva representativitat com a edificis aïllats de la xarxa elèctrica convencional. S’ha elaborat una metodologia pròpia, el Protocol d’instal·lació d’energia fotovoltaica en edificis aïllats de la xarxa elèctrica. S’ha realitzat una anàlisi de sensibilitats del dimensionat fotovoltaic davant la modificació de diversos paràmetres rellevants. Això ha permès determinar les característiques òptimes de viabilitat per als dos edificis en estudi i el cost de la instal·lació fotovoltaica (17.183€ el CLM i 164.815 € el Refugi del Fornet). Els resultats obtinguts en els dos edificis pilot han mostrat el gran cost relatiu entre l’energia fotovoltaica i l’energia elèctrica produïda a partir de combustibles fòssils.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

RESUM Masjoan és una masia del segle XII on resideix la família Masferrer des del 1710. Actualment a Masjoan l’activitat principal és el cultiu i venta de plantes ornamentals, i l’explotació forestal per obtenir fusta. Pel que fa a l’aigua, tant per a la realització de l’activitat professional com per al subministrament de la casa, aquesta prové de mines d’aigua natural situades en la finca. L’objectiu d’aquest TFC ha estat dissenyar un sistema autònom per automatitzar el procés de derivació de l’aigua procedent d’una mina, i d’aquesta manera aprofitar millor els recursos naturals dels que és disposa. El desenvolupament d’aquest sistema, comprèn la selecció i configuració de sensors i actuadors, el disseny del circuit amb la realització de la placa, el disseny del sistema d’alimentació autònom, el software que controla el sistema, i dimensionar la resta d’elements de la instal•lació. Tot el sistema està controlat per un microcontrolador PIC16F876 i alimentat per un mòdul solar de 4W. En el disseny s’ha procurat, sobredimencionar les diferents etapes per possibles ampliacions o modificacions del sistema i que el circuit procures optimitzar el consum d’energia. Com a conclusions cal dir que s’han assolit els objectius proposats amb èxit. S’ha aconseguit un disseny funcional i estable que actualment es troba en funcionament.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

RESUM Masjoan és una masia del segle XII on resideix la família Masferrer des del 1710. Actualment a Masjoan l’activitat principal és el cultiu i venta de plantes ornamentals, i l’explotació forestal per obtenir fusta. Pel que fa a l’aigua, tant per a la realització de l’activitat professional com per al subministrament de la casa, aquesta prové de mines d’aigua natural situades en la finca. L’objectiu d’aquest TFC ha estat dissenyar un sistema autònom per automatitzar el procés de derivació de l’aigua procedent d’una mina, i d’aquesta manera aprofitar millor els recursos naturals dels que és disposa. El desenvolupament d’aquest sistema, comprèn la selecció i configuració de sensors i actuadors, el disseny del circuit amb la realització de la placa, el disseny del sistema d’alimentació autònom, el software que controla el sistema, i dimensionar la resta d’elements de la instal•lació. Tot el sistema està controlat per un microcontrolador PIC16F876 i alimentat per un mòdul solar de 4W. En el disseny s’ha procurat, sobredimencionar les diferents etapes per possibles ampliacions o modificacions del sistema i que el circuit procures optimitzar el consum d’energia. Com a conclusions cal dir que s’han assolit els objectius proposats amb èxit. S’ha aconseguit un disseny funcional i estable que actualment es troba en funcionament.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

As computer chips implementation technologies evolve to obtain more performance, those computer chips are using smaller components, with bigger density of transistors and working with lower power voltages. All these factors turn the computer chips less robust and increase the probability of a transient fault. Transient faults may occur once and never more happen the same way in a computer system lifetime. There are distinct consequences when a transient fault occurs: the operating system might abort the execution if the change produced by the fault is detected by bad behavior of the application, but the biggest risk is that the fault produces an undetected data corruption that modifies the application final result without warnings (for example a bit flip in some crucial data). With the objective of researching transient faults in computer system’s processor registers and memory we have developed an extension of HP’s and AMD joint full system simulation environment, named COTSon. This extension allows the injection of faults that change a single bit in processor registers and memory of the simulated computer. The developed fault injection system makes it possible to: evaluate the effects of single bit flip transient faults in an application, analyze an application robustness against single bit flip transient faults and validate fault detection mechanism and strategies.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper we check whether generator's bid behavior at the Spanish whosale electricity market is consistent with the hypothesis of profit maximization on their residual demands. Using OMEL data, we find the arc-elacticity of the residual demand around the system marginal price. The results suggest thet the larger firms are not actually profit-msximization. We argue how the regulatory environment may drive these results. Finally, we repeat the analysis for the first session of the intra-day market where presumably firms may not have the same incentives as in the day-ahead market.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The demand for computational power has been leading the improvement of the High Performance Computing (HPC) area, generally represented by the use of distributed systems like clusters of computers running parallel applications. In this area, fault tolerance plays an important role in order to provide high availability isolating the application from the faults effects. Performance and availability form an undissociable binomial for some kind of applications. Therefore, the fault tolerant solutions must take into consideration these two constraints when it has been designed. In this dissertation, we present a few side-effects that some fault tolerant solutions may presents when recovering a failed process. These effects may causes degradation of the system, affecting mainly the overall performance and availability. We introduce RADIC-II, a fault tolerant architecture for message passing based on RADIC (Redundant Array of Distributed Independent Fault Tolerance Controllers) architecture. RADIC-II keeps as maximum as possible the RADIC features of transparency, decentralization, flexibility and scalability, incorporating a flexible dynamic redundancy feature, allowing to mitigate or to avoid some recovery side-effects.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Report for the scientific sojourn at the Stanford University from January until June 2007. Music is well known for affecting human emotional states, yet the relationship between specific musical parameters and emotional responses is still not clear. With the advent of new human-computer interaction (HCI) technologies, it is now possible to derive emotion-related information from physiological data and use it as an input to interactive music systems. Providing such implicit musical HCI will be highly relevant for a number of applications including music therapy, diagnosis, nteractive gaming, and physiologically-based musical instruments. A key question in such physiology-based compositions is how sound synthesis parameters can be mapped to emotional states of valence and arousal. We used both verbal and heart rate responses to evaluate the affective power of five musical parameters. Our results show that a significant correlation exists between heart rate and the subjective evaluation of well-defined musical parameters. Brightness and loudness showed to be arousing parameters on subjective scale while harmonicity and even partial attenuation factor resulted in heart rate changes typically associated to valence. This demonstrates that a rational approach to designing emotion-driven music systems for our public installations and music therapy applications is possible.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This Technical Report presents a tentative protocol used to assess the viability of powersupply systems. The viability of power-supply systems can be assessed by looking at the production factors (e.g. paid labor, power capacity, fossil-fuels) – needed for the system to operate and maintain itself – in relation to the internal constraints set by the energetic metabolism of societies. In fact, by using this protocol it becomes possible to link assessments of technical coefficients performed at the level of the power-supply systems with assessments of benchmark values performed at the societal level throughout the relevant different sectors. In particular, the example provided here in the case of France for the year 2009 makes it possible to see that in fact nuclear energy is not viable in terms of labor requirements (both direct and indirect inputs) as well as in terms of requirements of power capacity, especially when including reprocessing operations.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper aims to survey the techniques and methods described in literature to analyse and characterise voltage sags and the corresponding objectives of these works. The study has been performed from a data mining point of view

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper focus on the problem of locating single-phase faults in mixed distribution electric systems, with overhead lines and underground cables, using voltage and current measurements at the sending-end and sequence model of the network. Since calculating series impedance for underground cables is not as simple as in the case of overhead lines, the paper proposes a methodology to obtain an estimation of zero-sequence impedance of underground cables starting from previous single-faults occurred in the system, in which an electric arc occurred at the fault location. For this reason, the signal is previously pretreated to eliminate its peaks voltage and the analysis can be done working with a signal as close as a sinus wave as possible

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The work presented in this paper belongs to the power quality knowledge area and deals with the voltage sags in power transmission and distribution systems. Propagating throughout the power network, voltage sags can cause plenty of problems for domestic and industrial loads that can financially cost a lot. To impose penalties to responsible party and to improve monitoring and mitigation strategies, sags must be located in the power network. With such a worthwhile objective, this paper comes up with a new method for associating a sag waveform with its origin in transmission and distribution networks. It solves this problem through developing hybrid methods which hire multiway principal component analysis (MPCA) as a dimension reduction tool. MPCA reexpresses sag waveforms in a new subspace just in a few scores. We train some well-known classifiers with these scores and exploit them for classification of future sags. The capabilities of the proposed method for dimension reduction and classification are examined using the real data gathered from three substations in Catalonia, Spain. The obtained classification rates certify the goodness and powerfulness of the developed hybrid methods as brand-new tools for sag classification

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper offers empirical evidence from Spain of a connection between the tax administration and the political power. Firstly, the regional tax administration is not immune to the budgetary situation of regional government, and tends to exert a greater (or lesser) effort in tax collection the greater (or lower) the (expected) public deficit. At the same time, the system of unconditional grants from the central layer of government provokes an ¿income effect¿ which disincentivises the efforts of the tax administration. Secondly, these efforts also decrease when the margin to lose a parliamentary seat in an electoral district is cut, although the importance of this disincentive decreases according to the parliamentary strength of the incumbent

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper offers empirical evidence from Spain of a connection between the tax administration and the political power. Firstly, the regional tax administration is not immune to the budgetary situation of regional government, and tends to exert a greater (or lesser) effort in tax collection the greater (or lower) the (expected) public deficit. At the same time, the system of unconditional grants from the central layer of government provokes an ¿income effect¿ which disincentivises the efforts of the tax administration. Secondly, these efforts also decrease when the margin to lose a parliamentary seat in an electoral district is cut, although the importance of this disincentive decreases according to the parliamentary strength of the incumbent

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The As Pontes basin (12 km2), NW Iberian Peninsula, is bounded by a double restraining bend of a dextral strike-slip fault, which is related to the western onshore end of the Pyrenean belt. Surface and subsurface data obtained from intensive coal exploration and mining in the basin since the 1960s together with additional structural and stratigraphic sequence analysis allowed us to determine the geometric relationships between tectonic structures and stratigraphic markers. The small size of the basin and the large amount of quality data make the As Pontes basin a unique natural laboratory for improving our understanding of the origin and evolution of restraining bends. The double restraining bend is the end stage of the structural evolution of a compressive underlapping stepover, where the basin was formed. During the first stage (stepover stage), which began ca. 30 Ma ago (latest Rupelian) and lasted 3.4 My, two small isolated basins bounded by thrusts and normal faults were formed. For 1.3 My, the strike-slip faults, which defined the stepover, grew towards each other until joining and forming the double restraining bend, which bounds one large As Pontes basin (transition stage). The history of the basin was controlled by the activity of the double restraining bend for a further 3.4 My (restraining bend stage) and ended in mid-Aquitanian times (ca. 22 Ma).