21 resultados para non-respiratory
em Consorci de Serveis Universitaris de Catalunya (CSUC), Spain
Resumo:
Background: Non-invasive monitoring of respiratory muscle function is an area of increasing research interest, resulting in the appearance of new monitoring devices, one of these being piezoelectric contact sensors. The present study was designed to test whether the use of piezoelectric contact (non-invasive) sensors could be useful in respiratory monitoring, in particular in measuring the timing of diaphragmatic contraction.Methods: Experiments were performed in an animal model: three pentobarbital anesthetized mongrel dogs. The motion of the thoracic cage was acquired by means of a piezoelectric contact sensor placed on the costal wall. This signal is compared with direct measurements of the diaphragmatic muscle length, made by sonomicrometry. Furthermore, to assess the diaphragmatic function other respiratory signals were acquired: respiratory airflow and transdiaphragmatic pressure. Diaphragm contraction time was estimated with these four signals. Using diaphragm length signal as reference, contraction times estimated with the other three signals were compared with the contraction time estimated with diaphragm length signal.Results: The contraction time estimated with the TM signal tends to give a reading 0.06 seconds lower than the measure made with the DL signal (-0.21 and 0.00 for FL and DP signals, respectively), with a standard deviation of 0.05 seconds (0.08 and 0.06 for FL and DP signals, respectively). Correlation coefficients indicated a close link between time contraction estimated with TM signal and contraction time estimated with DL signal (a Pearson correlation coefficient of 0.98, a reliability coefficient of 0.95, a slope of 1.01 and a Spearman's rank-order coefficient of 0.98). In general, correlation coefficients and mean and standard deviation of the difference were better in the inspiratory load respiratory test than in spontaneous ventilation tests.Conclusion: The technique presented in this work provides a non-invasive method to assess the timing of diaphragmatic contraction in canines, using a piezoelectric contact sensor placed on the costal wall.
Resumo:
The forced oscillation technique (FOT) is a method for non-invasively assessing respiratory mechanics that is applicable both in paralysed and non-paralysed patients. As the FOT requires a minimal modification of the conventional ventilation setting and does not interfere with the ventilation protocol, the technique is potentially useful to monitor patient mechanics during invasive and noninvasive ventilation. FOT allows the assessment of the respiratory system linearity by measuring resistance and reactance at different lung volumes or end-expiratory pressures. Moreover, FOT allows the physician to track the changes in patient mechanics along the ventilation cycle. Applying FOT at different frequencies may allow the physician to interpret patient mechanics in terms of models with pathophysiological interest. The current methodological and technical experience make possible the implementation of portable and compact computerised FOT systems specifically addressed to its application in the mechanical ventilation setting.
Resumo:
Vegeu el resum a l'inici del document del fitxer adjunt
Resumo:
This note describes ParallelKnoppix, a bootable CD that allows econometricians with average knowledge of computers to create and begin using a high performance computing cluster for parallel computing in very little time. The computers used may be heterogeneous machines, and clusters of up to 200 nodes are supported. When the cluster is shut down, all machines are in their original state, so their temporary use in the cluster does not interfere with their normal uses. An example shows how a Monte Carlo study of a bootstrap test procedure may be done in parallel. Using a cluster of 20 nodes, the example runs approximately 20 times faster than it does on a single computer.
Resumo:
This note describes ParallelKnoppix, a bootable CD that allows creation of a Linux cluster in very little time. An experienced user can create a cluster ready to execute MPI programs in less than 10 minutes. The computers used may be heterogeneous machines, of the IA-32 architecture. When the cluster is shut down, all machines except one are in their original state, and the last can be returned to its original state by deleting a directory. The system thus provides a means of using non-dedicated computers to create a cluster. An example session is documented.
Resumo:
We study of noncompact Euclidean cone manifolds with cone angles less than c&2π and singular locus a submanifold. More precisely, we describe its structure outside a compact set. As a corol lary we classify those with cone angles & 2π/3 and those with cone angles = 2π/3.
Resumo:
Estudi elaborat a partir d’una estada al Royal Brompton Hospital, Londres, Regne Unit, durant octubre i novembre del 2006.Els beneficis de la estimulació beta-adrenèrgica en pacients amb lesió pulmonar aguda (LPA) són coneguts, però no es disposa de dades sobre el possible efecte antiinflamatori. El condensat d'aire exhalat (CAE) és una tècnica no-invasiva de recollida de mostres del tracte respiratori inferior, podent ser útil en la monitorització de patologies respiratòries. S’ha usat marcadors biològics en el CAE de pacients ventilats mecànicament amb LPA per estudiar el possible efecte antiinflamatori que el salbutamol hi podria exercir. El CAE va ser recollit abans i després de l'administració de salbutamol inahalat. Inmediatament després es va mesurar la conductivitat i el pH abans i després de la desgasificació amb heli. Es va mesurar la concentració de nitrits i nitrats. Les mostres varen ser liofilitzades i guardades a -80ºC. La concentració de leucotriè B4 es va mesurar després de la reconstitució de la mostra. Els resultats s'expressen com a mitjana (error estàndard de la mostra). No s'han detectat diferències entre els valors de CAE basals dels pacients amb LPA i els de referència de la població sana de Barcelona. Es conclou doncs que el CAE és una tècnica no invasiva que pot ser usada en la monitorització de paceints ventilats mecànicament. El salbutamol inhalat incrementa de manera significativa el pH del CAE dels paceints amb LPA, tot i que un efecte directe de la inhalació de slabutamol no pot ser desestimat.
Resumo:
"Vegeu el resum a l'inici del document del fitxer adjunt."
Resumo:
According to the account of the European Union (EU) decision making proposed in this paper, this is a bargaining process during which actors shift their policy positions with a view to reaching agreements on controversial issues.
Resumo:
Let A be a semiprime 2 and 3-torsion free non-commutative associative algebra. We show that the Lie algebra Der(A) of(associative) derivations of A is strongly non-degenerate, which is a strong form of semiprimeness for Lie algebras, under some additional restrictions on the center of A. This result follows from a description of the quadratic annihilator of a general Lie algebra inside appropriate Lie overalgebras. Similar results are obtained for an associative algebra A with involution and the Lie algebra SDer(A) of involution preserving derivations of A