9 resultados para measurement and metrology
em Consorci de Serveis Universitaris de Catalunya (CSUC), Spain
Resumo:
In this paper well-known summary inequality indexes are used to explore interregional income inequalities in Europe. In particular, we mainly employ Theilspopulation-weighted index because of its appealing properties. Two decomposition analysis are applied. First, regional inequalities are decomposed by regional subgroups (countries). Second, intertemporal inequality changes are separated into income and population changes. The main results can be summarized as follows. First, data confirm a reduction in crossregional inequality during 1982-97. Second, this reduction is basically due to real convergence among countries. Third, currently the greater part of European interregional disparities is within-country by nature, which introduce an important challenge for the European policy. Fourth, inequality changes are due mainly to income variations, population changes playing a minor role.
Resumo:
This paper presents a method for the measurement of changes in health inequality and income-related health inequality over time in a population.For pure health inequality (as measured by the Gini coefficient) andincome-related health inequality (as measured by the concentration index),we show how measures derived from longitudinal data can be related tocross section Gini and concentration indices that have been typicallyreported in the literature to date, along with measures of health mobilityinspired by the literature on income mobility. We also show how thesemeasures of mobility can be usefully decomposed into the contributions ofdifferent covariates. We apply these methods to investigate the degree ofincome-related mobility in the GHQ measure of psychological well-being inthe first nine waves of the British Household Panel Survey (BHPS). Thisreveals that dynamics increase the absolute value of the concentrationindex of GHQ on income by 10%.
Resumo:
In this paper we show that the orthorhombic phase of FeSi2 (stable at room temperature) displays a sizable anisotropy in the infrared spectra, with minor effects in the Raman data too. This fact is not trivial at all, since the crystal structure corresponds to a moderate distortion of the fluorite symmetry. Our analysis is carried out on small single crystals grown by flux transport, through polarization-resolved far-infrared reflectivity and Raman measurements. Their interpretation has been obtained by means of the simulated spectra with tight-binding molecular dynamics.
Resumo:
This paper studies two important reasons why people violate procedure invariance, loss aversion and scale compatibility. The paper extends previous research on loss aversion and scale compatibility by studying loss aversion and scale compatibility simultaneously, by looking at a new decision domain, medical decision analysis, and by examining the effect of loss aversion and scale compatibility on "well-contemplated preferences." We find significant evidence both of loss aversion and scale compatibility. However, the sizes of the biases due to loss aversion and scale compatibility vary over trade-offs and most participants do not behave consistently according to loss aversion or scale compatibility. In particular, the effect of loss aversion in medical trade-offs decreases with duration. These findings are encouraging for utility measurement and prescriptive decision analysis. There appear to exist decision contexts in which the effects of loss aversion and scale compatibility can be minimized and utilities can be measured that do not suffer from these distorting factors.
Resumo:
Purpose: Atheromatic plaque progression is affected, among others phenomena, by biomechanical, biochemical, and physiological factors. In this paper, the authors introduce a novel framework able to provide both morphological (vessel radius, plaque thickness, and type) and biomechanical (wall shear stress and Von Mises stress) indices of coronary arteries. Methods: First, the approach reconstructs the three-dimensional morphology of the vessel from intravascular ultrasound(IVUS) and Angiographic sequences, requiring minimal user interaction. Then, a computational pipeline allows to automatically assess fluid-dynamic and mechanical indices. Ten coronary arteries are analyzed illustrating the capabilities of the tool and confirming previous technical and clinical observations. Results: The relations between the arterial indices obtained by IVUS measurement and simulations have been quantitatively analyzed along the whole surface of the artery, extending the analysis of the coronary arteries shown in previous state of the art studies. Additionally, for the first time in the literature, the framework allows the computation of the membrane stresses using a simplified mechanical model of the arterial wall. Conclusions: Circumferentially (within a given frame), statistical analysis shows an inverse relation between the wall shear stress and the plaque thickness. At the global level (comparing a frame within the entire vessel), it is observed that heavy plaque accumulations are in general calcified and are located in the areas of the vessel having high wall shear stress. Finally, in their experiments the inverse proportionality between fluid and structural stresses is observed.
Resumo:
Purpose: Atheromatic plaque progression is affected, among others phenomena, by biomechanical, biochemical, and physiological factors. In this paper, the authors introduce a novel framework able to provide both morphological (vessel radius, plaque thickness, and type) and biomechanical (wall shear stress and Von Mises stress) indices of coronary arteries. Methods: First, the approach reconstructs the three-dimensional morphology of the vessel from intravascular ultrasound(IVUS) and Angiographic sequences, requiring minimal user interaction. Then, a computational pipeline allows to automatically assess fluid-dynamic and mechanical indices. Ten coronary arteries are analyzed illustrating the capabilities of the tool and confirming previous technical and clinical observations. Results: The relations between the arterial indices obtained by IVUS measurement and simulations have been quantitatively analyzed along the whole surface of the artery, extending the analysis of the coronary arteries shown in previous state of the art studies. Additionally, for the first time in the literature, the framework allows the computation of the membrane stresses using a simplified mechanical model of the arterial wall. Conclusions: Circumferentially (within a given frame), statistical analysis shows an inverse relation between the wall shear stress and the plaque thickness. At the global level (comparing a frame within the entire vessel), it is observed that heavy plaque accumulations are in general calcified and are located in the areas of the vessel having high wall shear stress. Finally, in their experiments the inverse proportionality between fluid and structural stresses is observed.
Resumo:
Pensado en un ámbito de tecnología médica, el propósito principal es el de realizar un seguido de medidas en diferentes partes del cuerpo para establecer unos valores máximos que nos permitan detectar cuando un paciente empieza a padecer estrés. Para ello se necesita un proceso de medición y otro de transmisión de los datos. Es aquí donde aparece el trabajo realizado en el proyecto. “ZigBee aplicado a la transmisión de datos de sensores biomédicos” está pensado para realizar la tarea de transmisión de los datos desde que el sensor realiza la medida hasta que los datos son monitorizados y almacenados. En la memoria del proyecto podremos encontrar el estudio realizado al medio de transmisión inalámbrico utilizado (ZigBee), el análisis del kit eZ430-RF2500 compatible con el medio, y finalmente la implementación del proyecto. Todo este trabajo finalizará con la recepción satisfactoria de los datos medidos por nuestro sensor biomédico (oxímetro) en el aplicativo personal programado con Visual Basic.
Resumo:
Generally, medicine books are concentrated almost exclusively in explaining methodology that analyzes fixed measures, measures done in a certain moment, nevertheless the evolution of the measurement and correct interpretation of the missed values are very important and sometimes can give the key information of the results obtained. Thus, the analysis of the temporary series and spectral analysis or analysis of the time series in the dominion of frequencies can be regarded as an appropriate tool for this kind of studies.In this work the frequency of the pulsating secretion of luteinizing hormone LH (thatregulates the fertile life of women) were analyzed in order to determine the existence of the significant frequencies obtained by analysis of Fourier. Detection of the frequencies, with which the pulsating secretion of the LH takes place, is a quite difficult question due topresence of the random errors in measures and samplings, i.e. that pulsating secretions of small amplitude are not detected and disregarded. In physiology it is accepted that cyclical patterns in the secretion of the LH exist and in the results of this research confirm this pattern and determine its frequency presented in the corresponded periodograms to each of studied cycle. The obtained results can be used as key pattern for future sampling frequencies in order to ¿catch¿ the significant picks of the luteinizing hormone and reflect on time forproductivity treatment of women.
Resumo:
The geometric characterisation of tree orchards is a high-precision activity comprising the accurate measurement and knowledge of the geometry and structure of the trees. Different types of sensors can be used to perform this characterisation. In this work a terrestrial LIDAR sensor (SICK LMS200) whose emission source was a 905-nm pulsed laser diode was used. Given the known dimensions of the laser beam cross-section (with diameters ranging from 12 mm at the point of emission to 47.2 mm at a distance of 8 m), and the known dimensions of the elements that make up the crops under study (flowers, leaves, fruits, branches, trunks), it was anticipated that, for much of the time, the laser beam would only partially hit a foreground target/object, with the consequent problem of mixed pixels or edge effects. Understanding what happens in such situations was the principal objective of this work. With this in mind, a series of tests were set up to determine the geometry of the emitted beam and to determine the response of the sensor to different beam blockage scenarios. The main conclusions that were drawn from the results obtained were: (i) in a partial beam blockage scenario, the distance value given by the sensor depends more on the blocked radiant power than on the blocked surface area; (ii) there is an area that influences the measurements obtained that is dependent on the percentage of blockage and which ranges from 1.5 to 2.5 m with respect to the foreground target/object. If the laser beam impacts on a second target/object located within this range, this will affect the measurement given by the sensor. To interpret the information obtained from the point clouds provided by the LIDAR sensors, such as the volume occupied and the enclosing area, it is necessary to know the resolution and the process for obtaining this mesh of points and also to be aware of the problem associated with mixed pixels.