28 resultados para electricity distribution networks
em Consorci de Serveis Universitaris de Catalunya (CSUC), Spain
Resumo:
We present a new asymptotic formula for the maximum static voltage in a simplified model for on-chip power distribution networks of array bonded integrated circuits. In this model the voltage is the solution of a Poisson equation in an infinite planar domain whose boundary is an array of circular pads of radius ", and we deal with the singular limit Ɛ → 0 case. In comparison with approximations that appear in the electronic engineering literature, our formula is more complete since we have obtained terms up to order Ɛ15. A procedure will be presented to compute all the successive terms, which can be interpreted as using multipole solutions of equations involving spatial derivatives of functions. To deduce the formula we use the method of matched asymptotic expansions. Our results are completely analytical and we make an extensive use of special functions and of the Gauss constant G
Resumo:
A mathematical model of the voltage drop which arises in on-chip power distribution networks is used to compare the maximum voltage drop in the case of different geometric arrangements of the pads supplying power to the chip. These include the square or Manhattan power pad arrangement, which currently predominates, as well as equilateral triangular and hexagonal arrangements. In agreement with the findings in the literature and with physical and SPICE models, the equilateral triangular power pad arrangement is found to minimize the maximum voltage drop. This headline finding is a consequence of relatively simple formulas for the voltage drop, with explicit error bounds, which are established using complex analysis techniques, and elliptic functions in particular.
Resumo:
A mathematical model of the voltage drop which arises in on-chip power distribution networks is used to compare the maximum voltage drop in the case of different geometric arrangements of the pads supplying power to the chip. These include the square or Manhattan power pad arrangement, which currently predominates, as well as equilateral triangular and hexagonal arrangements. In agreement with the findings in the literature and with physical and SPICE models, the equilateral triangular power pad arrangement is found to minimize the maximum voltage drop. This headline finding is a consequence of relatively simple formulas for the voltage drop, with explicit error bounds, which are established using complex analysis techniques, and elliptic functions in particular.
Resumo:
The work presented in this paper belongs to the power quality knowledge area and deals with the voltage sags in power transmission and distribution systems. Propagating throughout the power network, voltage sags can cause plenty of problems for domestic and industrial loads that can financially cost a lot. To impose penalties to responsible party and to improve monitoring and mitigation strategies, sags must be located in the power network. With such a worthwhile objective, this paper comes up with a new method for associating a sag waveform with its origin in transmission and distribution networks. It solves this problem through developing hybrid methods which hire multiway principal component analysis (MPCA) as a dimension reduction tool. MPCA reexpresses sag waveforms in a new subspace just in a few scores. We train some well-known classifiers with these scores and exploit them for classification of future sags. The capabilities of the proposed method for dimension reduction and classification are examined using the real data gathered from three substations in Catalonia, Spain. The obtained classification rates certify the goodness and powerfulness of the developed hybrid methods as brand-new tools for sag classification
Resumo:
We explain the choice between franchising and vertical integration by estimating a model of relative performance in a sample of 250 Spanish car distributors, controlling for self-selection and including environmental factors. The method allows us to estimate performance counterfactuals. Organizational choice seemingly aims to contain moral hazard for both distributors and manufacturers but it is subject to start-up constraints and switching costs. While the market for franchises remained underdeveloped, information asymmetries led to the opening of integrated outlets. Their subsequent conversion into franchised outlets probably involved prohibitive transaction costs. Consequently, they performed worse than would have been expected had they been independent, as confirmed by the systematic improvement observed when they were in fact converted. The timing of such conversions suggests that switching costs were prohibitive until firms developed a substantial cushion of temporary contracts, previously forbidden by regulation.
Resumo:
We study the effect of organizational choice and institutions on the performance ofSpanish car dealerships. Using outlet-level data from 1994, we find that verticallyintegrateddealerships showed substantially lower labor productivity, higher labor costs andlower profitability than franchised ones. Despite these gaps in performance, no verticallyintegratedoutlet was separated until 1994, yet the few outlets that were eventuallyseparated systematically improved their performance. We argue that the conversion ofintegrated outlets into franchised ones involved significant transaction costs, due to aninstitutional environment favoring permanent, highly-unionized employment relations. Inline with this argument, we find that the observed separations occurred in distributionnetworks that underwent marked reductions in worker unionization rates, following thelegalization of temporary labor contracts.
Resumo:
Actualmente vuelve a ser viable la organización mediante turnos de redes de distribución de riego a presión gracias al desarrollo de sistemas de automáticos de telegestión. La organización por turnos supone una disminución de los caudales en la red y el consiguiente ahorro económico. En la comunicación se presentan diversas expresiones sencillas para calcular la disminución relativa de caudales conseguida mediante la organización por turnos respecto a la demanda. Dicha disminución depende del número de hidrantes abastecidos por un tramo y de la probabilidad de que los hidrantes estén abiertos. Se ha contrastado los resultados de las expresiones propuestas con datos de proyecto y se consiguen buenos ajustes. El ahorro económico obtenido con la organización por turnos respecto a la demanda se puede estimar entre un 26 y un 49 % el ahorro medio de caudales.
Resumo:
This paper presents a new charging scheme for cost distribution along a point-to-multipoint connection when destination nodes are responsible for the cost. The scheme focus on QoS considerations and a complete range of choices is presented. These choices go from a safe scheme for the network operator to a fair scheme to the customer. The in-between cases are also covered. Specific and general problems, like the incidence of users disconnecting dynamically is also discussed. The aim of this scheme is to encourage the users to disperse the resource demand instead of having a large number of direct connections to the source of the data, which would result in a higher than necessary bandwidth use from the source. This would benefit the overall performance of the network. The implementation of this task must balance between the necessity to offer a competitive service and the risk of not recovering such service cost for the network operator. Throughout this paper reference to multicast charging is made without making any reference to any specific category of service. The proposed scheme is also evaluated with the criteria set proposed in the European ATM charging project CANCAN
Resumo:
We study the earnings structure and the equilibrium assignment of workers when workers exert intra-firm spillovers on each other.We allow for arbitrary spillovers provided output depends on some aggregate index of workers' skill. Despite the possibility of increasing returns to skills, equilibrium typically exists. We show that equilibrium will typically be segregated; that the skill space can be partitioned into a set of segments and any firm hires from only one segment. Next, we apply the model to analyze the effect of information technology on segmentation and the distribution of income. There are two types of human capital, productivity and creativity, i.e. the ability to produce ideas that may be duplicated over a network. Under plausible assumptions, inequality rises and then falls when network size increases, and the poorest workers cannot lose. We also analyze the impact of an improvement in worker quality and of an increased international mobility of ideas.
Resumo:
Peer-reviewed
Resumo:
Peer-reviewed
Resumo:
Current parallel applications running on clusters require the use of an interconnection network to perform communications among all computing nodes available. Imbalance of communications can produce network congestion, reducing throughput and increasing latency, degrading the overall system performance. On the other hand, parallel applications running on these networks posses representative stages which allow their characterization, as well as repetitive behavior that can be identified on the basis of this characterization. This work presents the Predictive and Distributed Routing Balancing (PR-DRB), a new method developed to gradually control network congestion, based on paths expansion, traffic distribution and effective traffic load, in order to maintain low latency values. PR-DRB monitors messages latencies on intermediate routers, makes decisions about alternative paths and record communication pattern information encountered during congestion situation. Based on the concept of applications repetitiveness, best solution recorded are reapplied when saved communication pattern re-appears. Traffic congestion experiments were conducted in order to evaluate the performance of the method, and improvements were observed.
Resumo:
Los sistemas de radio cognitivos son una solución a la deficiente distribución del espectro inalámbrico de frecuencias. Usando acceso dinámico al medio, los usuarios secundarios pueden comunicarse en canales de frecuencia disponibles, mientras los usuarios asignados no están usando dichos canales. Un buen sistema de mensajería de control es necesario para que los usuarios secundarios no interfieran con los usuarios primarios en las redes de radio cognitivas. Para redes en donde los usuarios son heterogéneos en frecuencia, es decir, no poseen los mismos canales de frecuencia para comunicarse, el grupo de canales utilizado para transmitir información de control debe elegirse cuidadosamente. Por esta razón, en esta tesis se estudian las ideas básicas de los esquemas de mensajería de control usados en las redes de radio cognitivas y se presenta un esquema adecuado para un control adecuado para usuarios heterogéneos en canales de frecuencia. Para ello, primero se presenta una nueva taxonomía para clasificar las estrategias de mensajería de control, identificando las principales características que debe cumplir un esquema de control para sistemas heterogéneos en frecuencia. Luego, se revisan diversas técnicas matemáticas para escoger el mínimo número de canales por los cuales se transmite la información de control. Después, se introduce un modelo de un esquema de mensajería de control que use el mínimo número de canales y que utilice las características de los sistemas heterogéneos en frecuencia. Por último, se comparan diversos esquemas de mensajería de control en términos de la eficiencia de transmisión.
Resumo:
This paper focus on the problem of locating single-phase faults in mixed distribution electric systems, with overhead lines and underground cables, using voltage and current measurements at the sending-end and sequence model of the network. Since calculating series impedance for underground cables is not as simple as in the case of overhead lines, the paper proposes a methodology to obtain an estimation of zero-sequence impedance of underground cables starting from previous single-faults occurred in the system, in which an electric arc occurred at the fault location. For this reason, the signal is previously pretreated to eliminate its peaks voltage and the analysis can be done working with a signal as close as a sinus wave as possible
Resumo:
Monitor a distribution network implies working with a huge amount of data coining from the different elements that interact in the network. This paper presents a visualization tool that simplifies the task of searching the database for useful information applicable to fault management or preventive maintenance of the network