4 resultados para count-min sketch

em Consorci de Serveis Universitaris de Catalunya (CSUC), Spain


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Renal disorders are an emerging problem in HIV-infected patients. We performed a cross-sectional study of the first 1000 HIV-infected patients attended at our HIV unit who agreed to participate. We determined the frequency of renal alterations and its related risk factors. Summary statistics and logistic regression were applied. The study sample comprised 970 patients with complete data. Most were white (94%) and men (76%). Median (IQR) age was 48 (42–53) years. Hypertension was diagnosed in 19%, dyslipidemia in 27%, and diabetes mellitus in 3%. According to the Chronic Kidney Disease Epidemiology Collaboration (CKD EPI) equation, 29 patients (3%) had an eGFR < 60 ml/min/1.73m2; 18 of them (62%) presented altered albumin/creatinine and protein/creatinine (UPC or UAC) ratios. Of the patients with eGFR> 60mL/min, it was present in 293 (30%), 38 of whom (7.1%) had UPC> 300mg/g. Increased risk of renal abnormalities was correlated with hypertension (OR, 1.821 [95%CI, 1.292;2.564]; p = 0.001), age (OR, 1.015 [95%CI, 1.001;1.030], per one year; p = 0.040), and use of tenofovir disoproxil fumarate (TDF) plus protease inhibitor (PI), (OR, 1.401 [95%CI, 1.078;1.821]; p = 0.012). Current CD4 cell count was a protective factor (OR, 0.9995 [95%CI, 0.9991;0.9999], per one cell; p = 0.035). A considerable proportion of patients presented altered UPC or UAC ratios, despite having an eGFR > 60mL/min. CD4 cell count was a protective factor; age, hypertension, and use of TDF plus PIs were risk factors for renal abnormalities. Based on our results, screen of renal abnormalities should be considered in all HIV-infected patients to detect these alterations early.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The high sensitivity and excellent timing accuracy of Geiger mode avalanche photodiodes makes them ideal sensors as pixel detectors for particle tracking in high energy physics experiments to be performed in future linear colliders. Nevertheless, it is well known that these sensors suffer from dark counts and afterpulsing noise, which induce false hits (indistinguishable from event detection) as well as an increase of the necessary area of the readout system. In this work, we present a comparison between APDs fabricated in a high voltage 0.35 µm and a high integration 0.13 µm commercially available CMOS technologies that has been performed to determine which of them best fits the particle collider requirements. In addition, a readout circuit that allows low noise operation is introduced. Experimental characterization of the proposed pixel is also presented in this work.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Avalanche photodiodes operated in the Geiger mode present very high intrinsic gain and fast time response, which make the sensor an ideal option for those applications in which detectors with high sensitivity and velocity are required. Moreover, they are compatible with conventional CMOS technologies, allowing sensor and front-end electronics integration within the pixel cell. Despite these excellent qualities, the photodiode suffers from high intrinsic noise, which degrades the performance of the detector and increases the memory area to store the total amount of information generated. In this work, a new front-end circuit that allows low reverse bias overvoltage sensor operation to reduce the noise in Geiger mode avalanche photodiode pixel detectors is presented. The proposed front-end circuit also enables to operate the sensor in the gated acquisition mode to further reduce the noise. Experimental characterization of the fabricated pixel with the conventional HV-AMS 0.35µm technology is also presented in this article.