9 resultados para coiled-coil
em Consorci de Serveis Universitaris de Catalunya (CSUC), Spain
Resumo:
Estudi elaborat a partir dâuna estada a la School of Life Sciences de la University of Dundee, Gran Bretanya, entre gener i març del 2007.L'estrès osmòtic causa rà pidament l'activació de la quinasa WNK1, que fosforila i activa a continuació les quinases SPAK i OSR1, que alhora regulen canals i transportadors dâions preexistents a la membrana celâ¢lular. El factor de transcripció NFAT5 és el principal regulador de la resposta celâ¢lular transcripcional secundà ria a hipertonicitat i sâha descrit que les quinases p38, Fyn, PKA, ERK/MEK i ATM estan involucrades en la seva regulació post-traduccional. No obstant, com que la funció dâaquestes quinases no explica totalment els mecanismes d'activació de NFAT5, sâha estudiat si lâactivitat transcripcional de NFAT5 pot estar regulada per WNK1, SPAK o OSR1. Aixà doncs, es va observar que lâactivitat dâun reporter dependent de NFAT5 no es veu afectada per la presència de cap de les quinases anteriors, en la seva forma wild-type o dominant negatiu. Dâaltra banda, es va estudiar quin domini de WNK1 és necessari per a que pugui respondre a hipertonicitat i quines quinases poden estar involucrades en la fosforilació de la serina 382 de WNK1. En conclusió, les dades obtingudes apunten que lâactivació de WNK1 en resposta a estrès osmòtic requereix la seva fosforilació en la serina 382 per quinases upstream com PAK2 o RSK i que també és necessari un dels seus dominis coiled-coil, almenys els aminoà cids 558 i 561. Aquests processos, però, semblen ser independents de lâactivació de NFAT5 en resposta a hipertonicitat. ââ
Resumo:
Endovascular coiling is a well-established therapy for treating intracranial aneurysms. Nonetheless, postoperative hemodynamic changes induced by this therapy remain not fully understood. The purpose of this work is to assess the influence of coil configuration and packing density on intra-aneurysmal hemodynamics
Resumo:
Aquesta tesi explora la possibilitat de fer servir enllaços inductius per a una aplicació de l’automòbil on el cablejat entre la centraleta (ECU) i els sensors o detectors és difícil o impossible. S’han proposat dos mètodes: 1) el monitoratge de sensors commutats (dos possibles estats) via acoblament inductiu i 2) la transmissió mitjançant el mateix principi físic de la potència necessària per alimentar els sensors autònoms remots. La detecció d'ocupació i del cinturó de seguretat per a seients desmuntables pot ser implementada amb sistemes sense fils passius basats en circuits ressonants de tipus LC on l'estat dels sensors determina el valor del condensador i, per tant, la freqüència de ressonància. Els canvis en la freqüència són detectats per una bobina situada en el terra del vehicle. S’ha conseguit provar el sistema en un marge entre 0.5 cm i 3 cm. Els experiments s’han dut a terme fent servir un analitzador d’impedàncies connectat a una bobina primària i sensors comercials connectats a un circuit remot. La segona proposta consisteix en transmetre remotament la potència des d’una bobina situada en el terra del vehicle cap a un dispositiu autònom situat en el seient. Aquest dispositiu monitorarà l'estat dels detectors (d'ocupació i de cinturó) i transmetrà les dades mitjançant un transceptor comercial de radiofreqüència o pel mateix enllaç inductiu. S’han avaluat les bobines necessàries per a una freqüència de treball inferior a 150 kHz i s’ha estudiat quin és el regulador de tensió més apropiat per tal d’aconseguir una eficiència global màxima. Quatre tipus de reguladors de tensió s’han analitzat i comparat des del punt de vista de l’eficiència de potència. Els reguladors de tensió de tipus lineal shunt proporcionen una eficiència de potència millor que les altres alternatives, els lineals sèrie i els commutats buck o boost. Les eficiències aconseguides han estat al voltant del 40%, 25% i 10% per les bobines a distàncies 1cm, 1.5cm, i 2cm. Les proves experimentals han mostrat que els sensors autònoms han estat correctament alimentats fins a distàncies de 2.5cm.
Resumo:
Inductive-based devices integrated with Si technology for biodetection applications are characterized, using simple resonant differential filter configurations. This has allowed the corroboration of the viability of the proposed circuits, which are characterized by their very high simplicity, for microinductive signal conditioning in high-sensitivity sensor devices. The simulation of these simple circuits predicts sensitivities of the differential output voltage which can achieve values in the range of 0.1-1 V/nH, depending on the coil parameters. These very high-sensitivity values open the possibility for the experimental detection of extremely small inductance changes in the devices. For real microinductive devices, both series resistance and parasitic capacitive components contribute to the decrease of the differential circuit sensitivity. Nevertheless, measurements performed using micro-coils fabricated with relatively high series resistance and coupling parasitic effects have allowed detection of changes in the range of 2 nH. which are compatible with biodetection applications with estimated detection limits below the picomolarity range.
Resumo:
A systematic method to improve the quality (Q) factor of RF integrated inductors is presented in this paper. The proposed method is based on the layout optimization to minimize the series resistance of the inductor coil, taking into account both ohmic losses, due to conduction currents, and magnetically induced losses, due to eddy currents. The technique is particularly useful when applied to inductors in which the fabrication process includes integration substrate removal. However, it is also applicable to inductors on low-loss substrates. The method optimizes the width of the metal strip for each turn of the inductor coil, leading to a variable strip-width layout. The optimization procedure has been successfully applied to the design of square spiral inductors in a silicon-based multichip-module technology, complemented with silicon micromachining postprocessing. The obtained experimental results corroborate the validity of the proposed method. A Q factor of about 17 have been obtained for a 35-nH inductor at 1.5 GHz, with Q values higher than 40 predicted for a 20-nH inductor working at 3.5 GHz. The latter is up to a 60% better than the best results for a single strip-width inductor working at the same frequency.
Resumo:
Exchange-biased Ni/FeF2 films have been investigated using vector coil vibrating-sample magnetometry as a function of the cooling field strength HFC . In films with epitaxial FeF2 , a loop bifurcation develops with increasing HFC as it divides into two sub-loops shifted oppositely from zero field by the same amount. The positively biased sub-loop grows in size with HFC until only a single positively shifted loop is found. Throughout this process, the negative and positive (sub)loop shifts maintain the same discrete value. This is in sharp contrast to films with twinned FeF2 where the exchange field gradually changes with increasing HFC . The transverse magnetization shows clear correlations with the longitudinal subloops. Interestingly, over 85% of the Ni reverses its magnetization by rotation, either in one step or through two successive rotations. These results are due to the single-crystal nature of the antiferromagnetic FeF2 , which breaks down into two opposite regions of large domains.
Resumo:
Actualment hi ha una gran varietat de marques i models d'estabilitzadors de tensió, tot i que tots estan dissenyats i construïts amb el mateix propòsit, entregar una tensió estable a la sortida del dispositiu. La raó per la que es fabriquen estabilitzadors de tensió, es basa en el fet que, tot i amb els avenços tècnics i millores dels serveis de l'àrea energètica, no s'han pogut eliminar les freqüents caigudes o pujades de tensió en les xarxes d'alimentació d'energia elèctrica, fet que pot ocasionar errors en el funcionament dels equips electrònics. És per això que la majoria d'usuaris d'equips electrònics interposen un estabilitzador de tensió entre la línea d'alimentació dels seus aparells. L'objectiu del treball és realitzar la construcció d'un dispositiu de tres bobines amb un nucli ferromagnètic per a dur a terme la funció d'estabilitzador de tensió alterna. Mitjançant la tècnica de reluctància de nucli saturable i aplicant-la en aquest cas pràctic, es vol aconseguir desenvolupar un estabilitzador de tensió fiable i econòmic. Aquest treball ha d'aportar una solució en entorns de treball, entre altres, on s'utilitzen màquines d'alimentació alternes que siguin molt sensibles a les variacions de tensió de la xarxa i que, a més a més, no suposi una despesa molt elevada.
Resumo:
Extension of shelf life and preservation of products are both very important for the food industry. However, just as with other processes, speed and higher manufacturing performance are also beneficial. Although microwave heating is utilized in a number of industrial processes, there are many unanswered questions about its effects on foods. Here we analyze whether the effects of microwave heating with continuous flow are equivalent to those of traditional heat transfer methods. In our study, the effects of heating of liquid foods by conventional and continuous flow microwave heating were studied. Among other properties, we compared the stability of the liquid foods between the two heat treatments. Our goal was to determine whether the continuous flow microwave heating and the conventional heating methods have the same effects on the liquid foods, and, therefore, whether microwave heat treatment can effectively replace conventional heat treatments. We have compared the colour, separation phenomena of the samples treated by different methods. For milk, we also monitored the total viable cell count, for orange juice, vitamin C contents in addition to the taste of the product by sensory analysis. The majority of the results indicate that the circulating coil microwave method used here is equivalent to the conventional heating method based on thermal conduction and convection. However, some results in the analysis of the milk samples show clear differences between heat transfer methods. According to our results, the colour parameters (lightness, red-green and blue-yellow values) of the microwave treated samples differed not only from the untreated control, but also from the traditional heat treated samples. The differences are visually undetectable, however, they become evident through analytical measurement with spectrophotometer. This finding suggests that besides thermal effects, microwave-based food treatment can alter product properties in other ways as well.
Resumo:
Typical Talaromyces ascomata were observed on dry Quercus suber leaf litter amongst the characteristic synnemata of Penicillium aureocephalum, and they appear to represent the sexual state of the latter species. The species is a synonym of the older Lasioderma flavovirens, and we propose the new combination Talaromyces flavovirens. Lectotype and epitype specimens are designated for this name. The defining characters of the asexual state include yellow, short-stalked, mycetozoan-like synnemata with an unusual, almost closed terminal head of penicillate conidiophores intermixed with sinuous hyphae, and dark green conidia. Ascomata could not be induced in culture, but PCR amplifications of mating-type genes indicate the species is heterothallic. In nature, ascocarp initials appear to be antheridia coiled around clavate ascogonia, similar to those of T. flavus, and the thick-walled, spiny ascospores are also similar to those of T. flavus. ITS barcodes and β-tubulin sequences place T. flavovirens in a clade with T. apiculatus, T. flavus, T. funiculosus, T. galapagensis, T. pinophilus, T. macrosporus, and seven other species.