11 resultados para Test–retest repeatability

em Consorci de Serveis Universitaris de Catalunya (CSUC), Spain


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: To evaluate the suitability of an improved version of an automatic segmentation method based on geodesic active regions (GAR) for segmenting cerebral vasculature with aneurysms from 3D X-ray reconstruc-tion angiography (3DRA) and time of °ight magnetic resonance angiography (TOF-MRA) images available in the clinical routine.Methods: Three aspects of the GAR method have been improved: execution time, robustness to variability in imaging protocols and robustness to variability in image spatial resolutions. The improved GAR was retrospectively evaluated on images from patients containing intracranial aneurysms in the area of the Circle of Willis and imaged with two modalities: 3DRA and TOF-MRA. Images were obtained from two clinical centers, each using di®erent imaging equipment. Evaluation included qualitative and quantitative analyses ofthe segmentation results on 20 images from 10 patients. The gold standard was built from 660 cross-sections (33 per image) of vessels and aneurysms, manually measured by interventional neuroradiologists. GAR has also been compared to an interactive segmentation method: iso-intensity surface extraction (ISE). In addition, since patients had been imaged with the two modalities, we performed an inter-modality agreement analysis with respect to both the manual measurements and each of the two segmentation methods. Results: Both GAR and ISE di®ered from the gold standard within acceptable limits compared to the imaging resolution. GAR (ISE, respectively) had an average accuracy of 0.20 (0.24) mm for 3DRA and 0.27 (0.30) mm for TOF-MRA, and had a repeatability of 0.05 (0.20) mm. Compared to ISE, GAR had a lower qualitative error in the vessel region and a lower quantitative error in the aneurysm region. The repeatabilityof GAR was superior to manual measurements and ISE. The inter-modality agreement was similar between GAR and the manual measurements. Conclusions: The improved GAR method outperformed ISE qualitatively as well as quantitatively and is suitable for segmenting 3DRA and TOF-MRA images from clinical routine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ningú no dubte ja del canvi de mentalitat que s’ha produït en els darrers anys en els compradors pel què fa al mercat de l’automòbil. La seguretat i el respecte per el medi ambient, són actualment dos dels factors claus que el consumidor té en compte a l’hora de comprar un vehicle. D’altra banda en els darrers anys la Unió Europea, ha fixat tota una sèrie normatives per tal de reduir les emissions nocives a l’atmosfera. Així doncs, més seguretat i menys emissions, signifiquen vehicles que incorporin components i sistemas cada cop més sofisticats, els quals, a la vegada, necessiten de bancs d’assaig i equips de test per tal de ser validats. Aquest fet ha provocat una revolució dins dels sistemes de test per a vehicles, per als quals han augmentat enormement les exigències en quan a precisions i repetibilitat per tal d’intentar reproduir, amb la màxima fiabilitat possible, les condicions de treball que hauran de suportar els components durant el seu ús real. Les característiques dels motors elèctrics, resulten ideals per a accionar aquest tipus d’aplicacions, ja que permeten un control del parell molt acurat i una repetibilitat quasi perfecte enfront d’altres sistemas utilitzats fins no fa massa temps. Aquesta demanda creixent d’aquest tipus de màquines elèctriques, obra una nova oportunitat de negoci per a les empreses fabricants de motors elèctrics. L’objectiu principal d’aquest treball és identificar i satisfer les necessitats dels clients, dins d’un mercat industrial concret: el mercat dels motors elèctrics per a bancs de proves de components per a la indústria de l’automoció. La fita és doncs la de proporcionar les eines necessàries per tal de que una empresa, fabricant de motors elèctrics de velocitat variable, pugui realitzar el disseny, desenvolupament i llançament comercial d’un nou tipus de motor, específicament pensat per aquest mercat, amb les màximes garanties d’èxit. Com a principal conclusió, el treball argumenta que el nou producte representa una oportunitat de negoci força atractiva i rendible per a l’empresa, i permetrà diversificar la oferta de la companyia cap a un nou sector fins ara no explotat.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Liquid pyrolysis is presented as a new production method of SnO2 nanocrystalline powders suitable for gas sensor devices. The method is based on a pyrolytic reaction of high tensioned stressed drops of an organic solution of SnCl4·5(H2O). The main advantages of the method are its capability to produce SnO2 nanopowders with high stability, its accurate control over the grain size and other structural characteristics, its high level of repeatability and its low industrialization implementation cost. The characterization of samples of SnO2 nanoparticles obtained by liquid pyrolysis in the range between 200ºC and 900ºC processing temperature is carried out by X-ray diffraction, transmission electron microscopy, Raman and X-ray photoelectron spectroscopy. Results are analyzed and discussed so as to validate the advantages of the liquid pyrolysis method.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this study was to develop and validate a scale to assess the diurnal impact of insomnia. The Insomnia Diurnal Impact Scale (IDIS) comprises six items designed to evaluate the daytime effects of insomnia. The sychometric properties of the original scale were analysed in a sample of 172 students, while its ability to differentiate insomniacs and non-insomniacs (according to the International Classification of Diseases (ICD)-10 criteria) was examined in a sample of 79 psychiatric patients and 82 individuals from the community. The psychometric properties of the English version were then analysed in a sample of 44 Englishspeaking participants. The results showed the internal consistency coefficient to be very good (0.86), with testretest reliability at 1 month being 0.79. A single factor explained almost 60% of the variance. Correlation of the IDIS with other scales varied between moderate and high values. Sensitivity was 78% and specificity 57% in the community sample, while the corresponding figures for the psychiatric population were 83% and 63%. Cronbach's ¿ coefficient for the English version reached a value of 0.93. These results indicate that the IDIS shows adequate reliability and validity with both general and psychiatric populations, and also that it can discriminate between the presence and absence of insomnia. The English version presents good preliminary results regarding item-corrected total correlation and internal consistency. In conclusion, the IDIS appears to be a useful tool in the primary care and mental health contexts for assessing insomnia-related diurnal dysfunction.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The aim of this studywas to adapt and assess the psychometric properties of the Spanish version of the sMARS in terms of evidence of validity and reliability of scores. The sMARS was administered to 342 students and, in order to assess convergent and discriminant validity, several subsamples completed a series of related tests. The factorial structure of the sMARSwas analyzed by means of a confirmatory factor analysis and results showed that the three-factor structure reported in the original test fits well with the data. Thus, three dimensions were established in the test: math test, numerical task and math course anxiety. The results of this study provide sound evidence that demonstrates the good psychometric properties of the scores of the Spanish version of the sMARS: strong internal consistency, high 7-week testretest reliability and good convergent/discriminant validity were evident. Overall, this study provides an instrument that allows us to obtain valid and reliable math anxiety measurements. This instrument may be a useful tool for educators and psychologists interested in identifying individuals that may have a low level of math mastery because of their anxiety.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: We propose and validate a computer aided system to measure three different mandibular indexes: cortical width, panoramic mandibular index and, mandibular alveolar bone resorption index. Study Design: Repeatability and reproducibility of the measurements are analyzed and compared to the manual estimation of the same indexes. Results: The proposed computerized system exhibits superior repeatability and reproducibility rates compared to standard manual methods. Moreover, the time required to perform the measurements using the proposed method is negligible compared to perform the measurements manually. Conclusions: We have proposed a very user friendly computerized method to measure three different morphometric mandibular indexes. From the results we can conclude that the system provides a practical manner to perform these measurements. It does not require an expert examiner and does not take more than 16 seconds per analysis. Thus, it may be suitable to diagnose osteoporosis using dental panoramic radiographs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The optimization of most pesticide and fertilizer applications is based on overall grove conditions. In this work we measurements. Recently, Wei [9, 10] used a terrestrial propose a measurement system based on a ground laser scanner to LIDAR to measure tree height, width and volume developing estimate the volume of the trees and then extrapolate their foliage a set of experiments to evaluate the repeatability and surface in real-time. Tests with pear trees demonstrated that the accuracy of the measurements, obtaining a coefficient of relation between the volume and the foliage can be interpreted as variation of 5.4% and a relative error of 4.4% in the linear with a coefficient of correlation (R) of 0.81 and the foliar estimation of the volume but without real-time capabilities. surface can be estimated with an average error less than 5 %.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: We propose and validate a computer aided system to measure three different mandibular indexes: cortical width, panoramic mandibular index and, mandibular alveolar bone resorption index. Study Design: Repeatability and reproducibility of the measurements are analyzed and compared to the manual estimation of the same indexes. Results: The proposed computerized system exhibits superior repeatability and reproducibility rates compared to standard manual methods. Moreover, the time required to perform the measurements using the proposed method is negligible compared to perform the measurements manually. Conclusions: We have proposed a very user friendly computerized method to measure three different morphometric mandibular indexes. From the results we can conclude that the system provides a practical manner to perform these measurements. It does not require an expert examiner and does not take more than 16 seconds per analysis. Thus, it may be suitable to diagnose osteoporosis using dental panoramic radiographs

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Needle trap devices (NTDs) are a relatively new and promising tool for headspace (HS) analysis. In this study, a dynamic HS sampling procedure is evaluated for the determination of volatile organic compounds (VOCs) in whole blood samples. A full factorial design was used to evaluate the influence of the number of cycles and incubation time and it is demonstrated that the controlling factor in the process is the number of cycles. A mathematical model can be used to determine the most appropriate number of cycles required to adsorb a prefixed amount of VOCs present in the HS phase whenever quantitative adsorption is reached in each cycle. Matrix effect is of great importance when complex biological samples, such as blood, are analyzed. The evaluation of the salting out effect showed a significant improvement in the volatilization of VOCs to the HS in this type of matrices. Moreover, a 1:4 (blood:water) dilution is required to obtain quantitative recoveries of the target analytes when external calibration is used. The method developed gives detection limits in the 0.020–0.080 μg L−1 range (0.1–0.4 μg L−1 range for undiluted blood samples) with appropriate repeatability values (RSD < 15% at high level and <23% at LOQ level). Figure of merits of the method can be improved by using a smaller phase ratio (i.e., an increase in the blood volume and a decrease in the HS volume), which lead to lower detection limits, better repeatability values and greater sensibility. Twenty-eight blood samples have been evaluated with the proposed method and the results agree with those indicated in other studies. Benzene was the only target compound that gave significant differences between blood levels detected in volunteer non-smokers and smokers

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objectives: The objectives of this study is to review the set of criteria of the Institute of Medicine (IOM) for priority-setting in research with addition of new criteria if necessary, and to develop and evaluate the reliability and validity of the final priority score. Methods: Based on the evaluation of 199 research topics, forty-five experts identified additional criteria for priority-setting, rated their relevance, and ranked and weighted them in a three-round modified Delphi technique. A final priority score was developed and evaluated. Internal consistency, test–retest and inter-rater reliability were assessed. Correlation with experts’ overall qualitative topic ratings were assessed as an approximation to validity. Results: All seven original IOM criteria were considered relevant and two new criteria were added (“potential for translation into practice”, and “need for knowledge”). Final ranks and relative weights differed from those of the original IOM criteria: “research impact on health outcomes” was considered the most important criterion (4.23), as opposed to “burden of disease” (3.92). Cronbach’s alpha (0.75) and test–retest stability (interclass correlation coefficient = 0.66) for the final set of criteria were acceptable. The area under the receiver operating characteristic curve for overall assessment of priority was 0.66. Conclusions: A reliable instrument for prioritizing topics in clinical and health services research has been developed. Further evaluation of its validity and impact on selecting research topics is required

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Ningú no dubte ja del canvi de mentalitat que s’ha produït en els darrers anys en els compradors pel què fa al mercat de l’automòbil. La seguretat i el respecte per el medi ambient, són actualment dos dels factors claus que el consumidor té en compte a l’hora de comprar un vehicle. D’altra banda en els darrers anys la Unió Europea, ha fixat tota una sèrie normatives per tal de reduir les emissions nocives a l’atmosfera. Així doncs, més seguretat i menys emissions, signifiquen vehicles que incorporin components i sistemas cada cop més sofisticats, els quals, a la vegada, necessiten de bancs d’assaig i equips de test per tal de ser validats. Aquest fet ha provocat una revolució dins dels sistemes de test per a vehicles, per als quals han augmentat enormement les exigències en quan a precisions i repetibilitat per tal d’intentar reproduir, amb la màxima fiabilitat possible, les condicions de treball que hauran de suportar els components durant el seu ús real. Les característiques dels motors elèctrics, resulten ideals per a accionar aquest tipus d’aplicacions, ja que permeten un control del parell molt acurat i una repetibilitat quasi perfecte enfront d’altres sistemas utilitzats fins no fa massa temps. Aquesta demanda creixent d’aquest tipus de màquines elèctriques, obra una nova oportunitat de negoci per a les empreses fabricants de motors elèctrics. L’objectiu principal d’aquest treball és identificar i satisfer les necessitats dels clients, dins d’un mercat industrial concret: el mercat dels motors elèctrics per a bancs de proves de components per a la indústria de l’automoció. La fita és doncs la de proporcionar les eines necessàries per tal de que una empresa, fabricant de motors elèctrics de velocitat variable, pugui realitzar el disseny, desenvolupament i llançament comercial d’un nou tipus de motor, específicament pensat per aquest mercat, amb les màximes garanties d’èxit. Com a principal conclusió, el treball argumenta que el nou producte representa una oportunitat de negoci força atractiva i rendible per a l’empresa, i permetrà diversificar la oferta de la companyia cap a un nou sector fins ara no explotat.