11 resultados para Stress wave method
em Consorci de Serveis Universitaris de Catalunya (CSUC), Spain
Resumo:
Aortic stiffness is an independent predictor factor for cardiovascular risk. Different methods for determining pulse wave velocity (PWV) are used, among which the most common are mechanical methods such as SphygmoCor or Complior, which require specific devices and are limited by technical difficulty in obtaining measurements. Doppler guided by 2D ultrasound is a good alternative to these methods. We studied 40 patients (29 male, aged 21 to 82 years) comparing the Complior method with Doppler. Agreement of both devices was high (R = 0.91, 0.84-0.95, 95% CI). The reproducibility analysis revealed no intra-nor interobserver differences. Based on these results, we conclude that Doppler ultrasound is a reliable and reproducible alternative to other established methods for themeasurement of aortic PWV
Resumo:
A simple extended finite field nuclear relaxation procedure for calculating vibrational contributions to degenerate four-wave mixing (also known as the intensity-dependent refractive index) is presented. As a by-product one also obtains the static vibrationally averaged linear polarizability, as well as the first and second hyperpolarizability. The methodology is validated by illustrative calculations on the water molecule. Further possible extensions are suggested
Resumo:
A modified Bargmann-Wigner method is used to derive (6s + 1)-component wave equations. The relation between different forms of these equations is shown.
Resumo:
Projecte de recerca elaborat a partir d’una estada al Department of Biological Science a la University of Lincoln, a la Gran Bretanya, entre octubre i desembre del 2006. L'objectiu del present assaig va ser desciure les respostes antioxidants d'estrès en gossos sotmesos a cirurgia electiva, en condicions de pràctica clínica normals, durant les fases de preoperatori i postoperatori.Setze gossos van ser sotmesos a orquiectomia o ovariohisterectomia electives, utilitzant un protocol quirúrgic estàndard. Durant les fases preoperatoria i postoperatoria, cada animal va ser confinat a la Unitat de Cures Intensives, temps durant el qual es va estudiar la seva resposta antioxidant. Els valors obtinguts a diferents temps van ser comparats amb el valor basal, que s'havia obtingut del mateix animal estant aquest en el seu ambient habitual. No es van detectar variacions significants causades per l'estrès perioperatori. Els valors màxims es van observar durant la fase preoperatoria, just després que l'animal fós confinat a la Unitat de Cures Intensives, moment en el que l'estrès percebut era degut a les amenaces psicològiques de una àrea restringida i de la manipulació per persones desonegudes. L'abscència de variacions significants podrien ser degudes al sistema i el temps d'emmagatzement de les mostres. En humana s'han descrit les alteracions en l'activitat dels antioxidants sèrics després d'un mes d'emmagatzematent. Per definir l'estabilitat, després de la recollida de mostres, de l'activitat dels antioxidants en sèrum de gos és necessari realitzar més estudis.
Resumo:
A new approach to the local measurement of residual stress in microstructures is described in this paper. The presented technique takes advantage of the combined milling-imaging features of a focused ion beam (FIB) equipment to scale down the widely known hole drilling method. This method consists of drilling a small hole in a solid with inherent residual stresses and measuring the strains/displacements caused by the local stress release, that takes place around the hole. In the presented case, the displacements caused by the milling are determined by applying digital image correlation (DIC) techniques to high resolution micrographs taken before and after the milling process. The residual stress value is then obtained by fitting the measured displacements to the analytical solution of the displacement fields. The feasibility of this approach has been demonstrated on a micromachined silicon nitride membrane showing that this method has high potential for applications in the field of mechanical characterization of micro/nanoelectromechanical systems.
Resumo:
We study the sensitivity limits of a broadband gravitational-wave detector based on dual resonators such as nested spheres. We determine both the thermal and back-action noises when the resonators displacements are read out with an optomechanical sensor. We analyze the contributions of all mechanical modes, using a new method to deal with the force-displacement transfer functions in the intermediate frequency domain between the two gravitational-wave sensitive modes associated with each resonator. This method gives an accurate estimate of the mechanical response, together with an evaluation of the estimate error. We show that very high sensitivities can be reached on a wide frequency band for realistic parameters in the case of a dual-sphere detector.
Resumo:
Egesta of a cave-dwelling mysid (Hemimysis speluncola Ledoyer, 1963) was studied in a submarine cave of Medes Islands, NW Mediterranean by in situ fecal pellet collecting. Fecal pellet production and gut fullness of mysids during incubation experiments are used to estimate mysid egestion rates. Intrinsic factors related with the natural history of this species such as population structure, density of mysids, daily rhythms and pellet decomposition rates are tested for their influence on the egestion rate. The effects of methodological artifacts, such as the stress induced by both incubation and preservation procedures, are also studied. An average mysid egests about 2.5 pellets per day into the cave. The time of day is the main factor affecting egestion. The highest deposition rate is between 2 to 4 hours after sunrise when about 38 % of the total daily pellet production becomes egested. Fecal pellet morphology changes with mysid demographic classes: immature mysids produce slender and thick pellets, whereas mature mysids produce only thick pellets. Immature classes show higher percentages of full guts than mature ones. Mysid density in the incubators does not affect the results on gut fullness, but it causes a decrease in the number of pellets collected after incubation. Coprorhexia seems to be the only plausible process to explain this paradox. The incubation procedure does not increase deposition rate significantly. Time of incubation is critical because the half-life of fecal pellets is about 2.5 hours. Fixation with liquid nitrogen decreases gut fullness and also deposition rates. Higher values are obtained with 70 % ethanol and 5 % formalin solutions which show very similar results for both gut fullness and pellet deposition rates. Nevertheless, ethanol is not suitable as fixative because it enhances the opacity of the body. Several suggestions are given in order to optimize the reliability of further in situ experiments for evaluation of egesta of Hemimysis speluncola in submarine caves.
Resumo:
Hydrogenated amorphous silicon (a‐Si:H) thin films have been obtained from pure SiH4 rf discharges by using the square wave modulation (SQWM) method. Film properties have been studied by means of spectroellipsometry, thermal desorption spectrometry, photothermal deflection spectroscopy and electrical conductivity measurements, as a function of the modulation frequency of the rf power amplitude (0.2-4000 Hz). The films deposited at frequencies about 1 kHz show the best structural and optoelectronic characteristics. Based upon the experimental results, a qualitative model is presented, which points up the importance of plasma negative ions in the deposition of a‐Si:H from SQWM rf discharges through their influence on powder particle formation.
Resumo:
n this work we analyze the behavior of complex information in Fresnel domain taking into account the limited capability to display complex transmittance values of current liquid crystal devices, when used as holographic displays. In order to do this analysis we compute the reconstruction of Fresnel holograms at several distances using the different parts of the complex distribution (real and imaginary parts, amplitude and phase) as well as using the full complex information adjusted with a method that combines two configurations of the devices in an adding architecture. The RMS error between the amplitude of these reconstructions and the original amplitude is used to evaluate the quality of the information displayed. The results of the error analysis show different behavior for the reconstructions using the different parts of the complex distribution and using the combined method of two devices. Better reconstructions are obtained when using two devices whose configurations densely cover the complex plane when they are added. Simulated and experimental results are also presented.
Resumo:
Body percussion using to the BAPNE method is a means of cognitive stimulation with multiple applications. The aim of this research is to assess their full potential as a source of therapy. The methodology used is theoretical in nature and makes use of a wide bibliography to find evidence for its therapeutic effect. In essence, body percussion can be seen to lead to improvements in three areas. the Physical, as it stimulates awareness of the body, control of movement and muscular strength, coordination and balance; the Mental, as it improves concentration, memory and perception; and finally Socio-affective, as it helps to build egalitarian relationships and leads to a decrease in anxiety in social interactions. This means of therapy has several different uses and it is targeted at different groups. In the present investigation we categorise them into five main groups: individuals with neurodegenerative diseases like Alzheimer's or Parkinson's disease; individuals with learning disorders such as dyslexia or ADHD; patients affected by diseases of the spinal cord, cranial neuropathies and trauma (Neurorehabilitation); and for the treatment of addictive behavior (addiction); and depressive disorders or anxiety disorders.After thorough analysis, we have found scientific evidence that the therapeutic body percussion using the BAPNE method improves the quality of life of patients and it is an important factor in stabilizing the development of different diseases.In addition, evidence involving certain biological indicators (in control and experimental groups, and through a pre-test and post-test) show its effect on levels of stress and anxiety (reduction of cortisol), as well as improvement of social relations as a result of working as a group (increased levels of oxytocin), and improvements seen in self-esteem and in a variety of personal aspects through the Aspects of Identity questionnaire.
Resumo:
Background: Being physically assaulted is known to increase the risk of the occurrence of post-traumatic stress disorder (PTSD) symptoms but it may also skew judgements about the intentions of other people. The objectives of the study were to assess paranoia and PTSD after an assault and to test whether theory-derived cognitive factors predicted the persistence of these problems. Method: At 4 weeks after hospital attendance due to an assault, 106 people were assessed on multiple symptom measures (including virtual reality) and cognitive factors from models of paranoia and PTSD. The symptom measures were repeated 3 and 6 months later. Results: Factor analysis indicated that paranoia and PTSD were distinct experiences, though positively correlated. At 4 weeks, 33% of participants met diagnostic criteria for PTSD, falling to 16% at follow-up. Of the group at the first assessment, 80% reported that since the assault they were excessively fearful of other people, which over time fell to 66%. Almost all the cognitive factors (including information-processing style during the trauma, mental defeat, qualities of unwanted memories, self-blame, negative thoughts about self, worry, safety behaviours, anomalous internal experiences and cognitive inflexibility) predicted later paranoia and PTSD, but there was little evidence of differential prediction. Conclusions: Paranoia after an assault may be common and distinguishable from PTSD but predicted by a strikingly similar range of factors.