4 resultados para SISTEMA DE MEDICIÓN PREPAGO
em Consorci de Serveis Universitaris de Catalunya (CSUC), Spain
Resumo:
Measuring the height of the vertical jump is an indicator of the strength and power of the lower body. The technological tools available to measure the vertical jump are black boxes and are not open to third-party verification or adaptation. We propose the creation of a measurement system called Chronojump-Boscosystem, consisting of open hardware and free software. Methods: A microcontroller was created and validated using a square wave generator and an oscilloscope. Two types of contact platforms were developed using different materials. These platforms were validated by the minimum pressure required for activation at different points by a strain gauge, together with the on/off time of our platforms in respect of the Ergojump-Boscosystem platform by a sample of 8 subjects performing submaximal jumps with one foot on each platform. Agile methodologies were used to develop and validate the software. Results: All the tools fall under the free software / open hardware guidelines and are, in that sense, free. The microcontroller margin of error is 0.1%. The validity of the fiberglass platform is 0.95 (ICC). The management software contains nearly 113.000 lines of code and is available in 7 languages.
Resumo:
Objetivo: Validar en asistencia prehospitalaria la medición de lactato capilar (Lc), por punción capilar (sistema portátil, SP), con lactato venoso (Lv) medido en laboratorio hospitalario. Valorar predicción de mortalidad 28 días (M28d). Metodología: prospectivo, observacional, 165 pacientes, asistidos en prehospitalaria. Resultados: Valores de Lc son mayores que Lv. Ambas variables se correlacionan significativamente, aunque débil. Otras variables hemodinámicas, oximétrica y temperatura, no estas asociadas con Lc ni Lv. Mortalidad: 8,1%. Lc tiene menor valor predictor (M28d) que Lv. Conclusiones: en prehospitalaria, Lc medido con SP, se correlaciona débilmente con Lv y pierde valor predictivo con éste en M28d.
Resumo:
Evaluar la utilidad de 75SeHCAT como prueba de primera línea en el diagnóstica en el síndrome diarreico crónico (SDC). Se estudiaron prospectivamente 47 pacientes. En todos se midió la retención abdominal a los 7 días post-administración 75SeHCAT (RA7). Los pacientes con prueba alterada se evaluo la respuesta a la resincolestiramina y se realizó un nuevo test a los 3 meses. çEn nuestro estudio se objetivo que la medición de la RA7 de 75SeHCAT permite un diagnóstico precoz de la malabsorción de sales biliares en el 42.5 % de pacientes con SDC.
Resumo:
Strategic management is based upon a performance measurement system that allows gearing decision making towards accomplishing the established objectives.In a changing economic situation, the measurement of the effects of tourism is fundamental in order to know the efficiency and sustainability of that industry and of the territory in which takes place its activity. We propose a performance measurement system for the sustainable management of a tourism destination, so it will support the adoption of public policies and their follow-up, and as an instrument that will promote the responsible participation of the stakeholders with stakes in the destination. In accordance with the guidelines of the Agenda for a sustainable and competitive European tourism, we design a system based on the identification of the axes over which hinges the success of the management of tourism destinations, taking into account the long-term sustainability of this activity. We position the performance measurement system, and especially the balanced scorecard, as a support tool for the strategic planning of destinations. To the extent that this is possible, the performance measures are selected and structured according to the patterns of the balanced scorecard. Finally, we apply the conceptual model to the central Costa Brava