27 resultados para Rib bone

em Consorci de Serveis Universitaris de Catalunya (CSUC), Spain


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Ewing sarcoma or primitive neuroectodermal tumor (PNET) of bone is the second most common pediatric malignant bone tumor. The median age at diagnosis is 15 years and there is a male predilection of 1.5/1. The authors present the case of a 14-year-old boy with Ewing sarcoma situated on the left ninth rib which was being investigated for respiratory tract infection. Pleurisy is the most common misdiagnosis. Our case illustrates the importance of recognizing exceptional features when interpreting FDG PET or scintigraphy to prevent the misinterpretation of metastases as other etiologies, such as infection.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To analyse whether bone mineral density (BMD) assessment is required in postmenopausal women presenting with low trauma vertebral fracture. Methods: Women with vertebral fracture diagnosed over a 10 year period were recruited from our database. The following were excluded: (a) patients with high energy trauma; (b) patients with malignancies; (c) patients with a metabolic bone disease other than osteoporosis. All postmenopausal women were included in whom BMD had been evaluated at both the lumbar spine and femoral neck by dual energy x ray absorptiometry during the six months after the diagnosis. Patients with a potential cause of osteoporosis other than age and menopause were not considered. A total of 215 patients were identified. Results: The mean (SD) age of the patients was 65.9 (6.9) years. BMD at the lumbar spine was 0.725 (0.128) g/cm2 and the T score was ¿2.94 (1.22); BMD at the femoral neck was 0.598 (0.095) g/cm2 and the T score was ¿2.22 (0.89). The BMD of the patients was significantly lower than that of the general population at both the lumbar spine and femoral neck. When the lowest value of the two analysed zones was considered, six patients (3%) showed a normal BMD, 51 (23.5%) osteopenia, and 158 (73.5%) osteoporosis. The prevalence of osteoporosis at the femoral neck increased with age; it was 25% in patients under 60, 35% in patients aged 60¿70, and 60% in patients over 70. Conclusion: These results indicate that bone densitometry is not required in postmenopausal women with clinically diagnosed vertebral fractures if it is performed only to confirm the existence of a low BMD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Criteria to decide which patients with rheumatoid arthritis (RA) should be examined by dual energy x ray absorptiometry (DXA) are currently not available. The rheumatologists from Amsterdam have proposed preliminary criteria based on clinical risk factors (age, disease activity, and functional status). These criteria are preliminary and not widely accepted but might be helpful in practice. The value of the proposal in a group of Spanish postmenopausal women with RA is analysed. METHODS DXA (lumbar spine and femoral neck) was performed in 128 patients recruited from a clinical setting, and the proposed criteria were applied. T and Z scores were established for a Spanish reference population. RESULTS The mean (SD) age of the patients was 61.3 (10.7) and mean duration of the postmenopausal period 14.5 (10.1) years. Mean duration of RA was 13.7 (7.7) years. Mean C reactive protein was 22 (21) mg/l; mean erythrocyte sedimentation rate 26 (18) mm/1st h; and mean Health Assessment Questionnaire score 1.25 (0.79). Ninety (70%) patients fulfilled the proposed criteria. Their sensitivity for the diagnosis of osteoporosis (T score ¿¿2.5 SD) was 86% and their specificity, 43%. Positive predictive value was 54% and negative predictive value, 79%. CONCLUSIONS The proposed criteria seem a good screening method for the selection of those patients with RA whose bone mineral density should be assessed as the sensitivity and negative predictive value are acceptable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A comparative study of the parts played by technetium-99m diphosphonate and gallium-67 citrate bone scanning in the early diagnosis of infectious spondylodiscitis is presented. Nineteen patients were included in the study. All patients (11 men aged 19-70 years and eight women aged 18-72 years) had a history of back pain varying in duration from one to 15 weeks. A 99mTc diphosphonate bone scan was positive in 17 patients. The two patients with negative results had less than two weeks of back pain. The 67Ga citrate bone scan showed uptake in all patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report on the study and modeling of the structural and optical properties of rib-loaded waveguides working in the 600-900-nm spectral range. A Si nanocrystal (Si-nc) rich SiO2 layer with nominal Si excess ranging from 10% to 20% was produced by quadrupole ion implantation of Si into thermal SiO2 formed on a silicon substrate. Si-ncs were precipitated by annealing at 1100°C, forming a 0.4-um-thick core layer in the waveguide. The Si content, the Si-nc density and size, the Si-nc emission, and the active layer effective refractive index were determined by dedicated experiments using x-ray photoelectron spectroscopy, Raman spectroscopy, energy-filtered transmission electron microscopy, photoluminescence and m-lines spectroscopy. Rib-loaded waveguides were fabricated by photolithographic and reactive ion etching processes, with patterned rib widths ranging from 1¿to¿8¿¿m. Light propagation in the waveguide was observed and losses of 11dB/cm at 633 and 780 nm were measured, modeled and interpreted.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Power leakage properties and guiding conditions of rib antiresonant reflecting optical waveguides (rib-ARROW) have been theoretically and experimentally studied as a function of wavelength and polarization of the light for different geometrical and optical parameters that characterize the rib-ARROW structure. Obtained results show that rib-ARROWs can only be fabricated with low losses in a wavelength range when determined rib configurations are adopted. Furthermore, these waveguides exhibit a polarization sensitivity that largely depends on the core-substrate refractive index difference. Together with the experimental results, theoretical calculations from different modeling methods are also presented and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A comparative study of the parts played by technetium-99m diphosphonate and gallium-67 citrate bone scanning in the early diagnosis of infectious spondylodiscitis is presented. Nineteen patients were included in the study. All patients (11 men aged 19-70 years and eight women aged 18-72 years) had a history of back pain varying in duration from one to 15 weeks. A 99mTc diphosphonate bone scan was positive in 17 patients. The two patients with negative results had less than two weeks of back pain. The 67Ga citrate bone scan showed uptake in all patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bone metastases are the result of a primary cancer invasion which spreads into the bone marrow through the lymphogenous or hematogenous pathways. Bone metastases are a common complication of cancer.The primary cancers that most frequently metastasize to bone are breast and prostate cancer (65 - 75 %) amongst many others (thyroid 42 %, lung 36 % or kidney 35 %) (Suva et al., 2011). Although the exact incidence of bone metastases is unknown given its dependence on the type of primary cancer, it is estimated that 350,000 people die of bone metastases annually in the United States.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present study describes some of the applications of ultrasound in bone surgery, based on the presentation of two clinical cases. The Piezosurgery® ultrasound device was used (Tecnología Mectron Medical, Carasco, Italy). In one case the instrument was used to harvest a chin bone graft for placement in a bone defect at level 1.2, while in the other case a bony window osteotomy was made in the external wall of the maxillary sinus, in the context of a sinus membrane lift procedure. The Piezosurgery® device produces specific ultrasound frequency modulation (25-29 kHz), and has been designed to secure increased precision in application to bone surgery. This instrument produces selective sectioning of the mineralized bone structures, and causes less intra- and postoperative bleeding. One of the advantages of the Piezosurgery® device is that it can be used for maxillary sinus lift procedures in dental implant placement. In this context it considerably lessens the risk of sinus mucosa laceration by preparing the bony window in the external wall of the upper maxilla, and can be used to complete the lifting maneuver. The use of ultrasound in application to hard tissues can be regarded as a slow technique compared with the conventional rotary instruments, since it requires special surgical skill and involves a certain learning curve.