29 resultados para Repeated measures

em Consorci de Serveis Universitaris de Catalunya (CSUC), Spain


Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper we describe the results of a simulation study performed to elucidate the robustness of the Lindstrom and Bates (1990) approximation method under non-normality of the residuals, under different situations. Concerning the fixed effects, the observed coverage probabilities and the true bias and mean square error values, show that some aspects of this inferential approach are not completely reliable. When the true distribution of the residuals is asymmetrical, the true coverage is markedly lower than the nominal one. The best results are obtained for the skew normal distribution, and not for the normal distribution. On the other hand, the results are partially reversed concerning the random effects. Soybean genotypes data are used to illustrate the methods and to motivate the simulation scenarios

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In this paper we analyse, using Monte Carlo simulation, the possible consequences of incorrect assumptions on the true structure of the random effects covariance matrix and the true correlation pattern of residuals, over the performance of an estimation method for nonlinear mixed models. The procedure under study is the well known linearization method due to Lindstrom and Bates (1990), implemented in the nlme library of S-Plus and R. Its performance is studied in terms of bias, mean square error (MSE), and true coverage of the associated asymptotic confidence intervals. Ignoring other criteria like the convenience of avoiding over parameterised models, it seems worst to erroneously assume some structure than do not assume any structure when this would be adequate.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Using data from the Spanish household budget survey, we investigate life- cycle effects on several product expenditures. A latent-variable model approach is adopted to evaluate the impact of income on expenditures, controlling for the number of members in the family. Two latent factors underlying repeated measures of monetary and non-monetary income are used as explanatory variables in the expenditure regression equations, thus avoiding possible bias associated to the measurement error in income. The proposed methodology also takes care of the case in which product expenditures exhibit a pattern of infrequent purchases. Multiple-group analysis is used to assess the variation of key parameters of the model across various household life-cycle typologies. The analysis discloses significant life-cycle effects on the mean levels of expenditures; it also detects significant life-cycle effects on the way expenditures are affected by income and family size. Asymptotic robust methods are used to account for possible non-normality of the data.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Using data from the Spanish household budget survey, we investigate life-cycle effects on several product expenditures. A latent-variable model approach is adopted to evaluate the impact of income on expenditures, controlling for the number of members in the family. Two latent factors underlying repeated measures of monetary and non-monetary income are used as explanatory variables in the expenditure regression equations, thus avoiding possible bias associated to the measurement error in income. The proposed methodology also takes care of the case in which product expenditures exhibit a pattern of infrequent purchases. Multiple-group analysis is used to assess the variation of key parameters of the model across various household life-cycle typologies. The analysis discloses significant life-cycle effects on the mean levels of expenditures; it also detects significant life-cycle effects on the way expenditures are affected by income and family size. Asymptotic robust methods are used to account for possible non-normality of the data.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objectiu general: desenvolupament del Programa Pacient Expert en obesitat. Objectius específics: es basaran amb el compliment de la dieta i l’activitat física, les mesures fisiològiques, la capacitat d’autogestió i el grau de satisfacció. Metodologia: - Àmbit d’estudi: Atenció Primària en Salut. - Disseny: estudi quantitatiu de tipus assaig clínic aleatoritzat. - Participants: adults amb obesitat. - Obtenció de dades: per l’anàlisi de variància per mesures repetides, l’anàlisi del discurs i l’observació estructurada. Limitacions de l’estudi: possible buit de dades per la pèrdua de participants o per la falta de continuïtat d’aquests.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: As the long-term efficacy of stereotactic body radiation therapy (SBRT) becomes established and other prostate cancer treatment approaches are refined and improved, examination of quality of life (QOL) following prostate cancer treatment is critical in driving both patient and clinical treatment decisions. We present the first study to compare QOL after SBRT and radical prostatectomy, with QOL assessed at approximately the same times pre- and post-treatment and using the same validated QOL instrument. Methods: Patients with clinically localized prostate cancer were treated with either radical prostatectomy (n = 123 Spanish patients) or SBRT (n = 216 American patients). QOL was assessed using the Expanded Prostate Cancer Index Composite (EPIC) grouped into urinary, sexual, and bowel domains. For comparison purposes, SBRT EPIC data at baseline, 3 weeks, 5, 11, 24, and 36 months were compared to surgery data at baseline, 1, 6, 12, 24,and 36 months. Differences in patient characteristics between the two groups were assessed using Chi-squared tests for categorical variables and t-tests for continuous variables. Generalized estimating equation (GEE) models were constructed for each EPIC scale to account for correlation among repeated measures and used to assess the effect of treatment on QOL. Results: The largest differences in QOL occurred in the first 16 months after treatment, with larger declines following surgery in urinary and sexual QOL as compared to SBRT, and a larger decline in bowel QOL following SBRT as compared to surgery. Long-term urinary and sexual QOL declines remained clinically significantly lower for surgery patients but not for SBRT patients. Conclusions: Overall, these results may have implications for patient and physician clinical decision making which are often influenced by QOL. These differences in sexual, urinary and bowel QOL should be closely considered in selecting the right treatment, especially in evaluating the value of non-invasive treatments, such as SBRT.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

BACKGROUND: Previous cross-sectional studies report that cognitive impairment is associated with poor psychosocial functioning in euthymic bipolar patients. There is a lack of long-term studies to determine the course of cognitive impairment and its impact on functional outcome. Method A total of 54 subjects were assessed at baseline and 6 years later; 28 had DSM-IV TR bipolar I or II disorder (recruited, at baseline, from a Lithium Clinic Program) and 26 were healthy matched controls. They were all assessed with a cognitive battery tapping into the main cognitive domains (executive function, attention, processing speed, verbal memory and visual memory) twice over a 6-year follow-up period. All patients were euthymic (Hamilton Rating Scale for Depression score lower than 8 and Young mania rating scale score lower than 6) for at least 3 months before both evaluations. At the end of follow-up, psychosocial functioning was also evaluated by means of the Functioning Assessment Short Test. RESULTS: Repeated-measures multivariate analysis of covariance showed that there were main effects of group in the executive domain, in the inhibition domain, in the processing speed domain, and in the verbal memory domain (p<0.04). Among the clinical factors, only longer illness duration was significantly related to slow processing (p=0.01), whereas strong relationships were observed between impoverished cognition along time and poorer psychosocial functioning (p<0.05). CONCLUSIONS: Executive functioning, inhibition, processing speed and verbal memory were impaired in euthymic bipolar out-patients. Although cognitive deficits remained stable on average throughout the follow-up, they had enduring negative effects on psychosocial adaptation of patients.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: As the long-term efficacy of stereotactic body radiation therapy (SBRT) becomes established and other prostate cancer treatment approaches are refined and improved, examination of quality of life (QOL) following prostate cancer treatment is critical in driving both patient and clinical treatment decisions. We present the first study to compare QOL after SBRT and radical prostatectomy, with QOL assessed at approximately the same times pre- and post-treatment and using the same validated QOL instrument. Methods: Patients with clinically localized prostate cancer were treated with either radical prostatectomy (n = 123 Spanish patients) or SBRT (n = 216 American patients). QOL was assessed using the Expanded Prostate Cancer Index Composite (EPIC) grouped into urinary, sexual, and bowel domains. For comparison purposes, SBRT EPIC data at baseline, 3 weeks, 5, 11, 24, and 36 months were compared to surgery data at baseline, 1, 6, 12, 24,and 36 months. Differences in patient characteristics between the two groups were assessed using Chi-squared tests for categorical variables and t-tests for continuous variables. Generalized estimating equation (GEE) models were constructed for each EPIC scale to account for correlation among repeated measures and used to assess the effect of treatment on QOL. Results: The largest differences in QOL occurred in the first 1-6 months after treatment, with larger declines following surgery in urinary and sexual QOL as compared to SBRT, and a larger decline in bowel QOL following SBRT as compared to surgery. Long-term urinary and sexual QOL declines remained clinically significantly lower for surgery patients but not for SBRT patients. Conclusions: Overall, these results may have implications for patient and physician clinical decision making which are often influenced by QOL. These differences in sexual, urinary and bowel QOL should be closely considered in selecting the right treatment, especially in evaluating the value of non-invasive treatments, such as SBRT.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This paper analyses the effects of manipulating the cognitive complexity of L2 oral tasks on language production. It specifically focuses on self-repairs, which are taken as a measure of accuracy since they denote both attention to form and an attempt at being accurate. By means of a repeated measures de- sign, 42 lower-intermediate students were asked to perform three different tasks types (a narrative, and instruction-giving task, and a decision-making task) for which two degrees of cognitive complexity were established. The narrative task was manipulated along +/− Here-and-Now, an instruction-giving task ma- nipulated along +/− elements, and the decision-making task which is manipu- lated along +/− reasoning demands. Repeated measures ANOVAs are used for the calculation of differences between degrees of complexity and among task types. One-way ANOVA are used to detect potential differences between low- proficiency and high-proficiency participants. Results show an overall effect of Task Complexity on self-repairs behavior across task types, with different be- haviors existing among the three task types. No differences are found between the self-repair behavior between low and high proficiency groups. Results are discussed in the light of theories of cognition and L2 performance (Robin- son 2001a, 2001b, 2003, 2005, 2007), L1 and L2 language production models (Levelt 1989, 1993; Kormos 2000, 2006), and attention during L2 performance (Skehan 1998; Robinson, 2002).

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: To compare the anesthetic action of 0.5% bupivacaine in relation to 4% articaine, both with 1:200,000 epinephrine, in the surgical removal of lower third molars. As a secondary objective hemodynamic changes using both anesthetics were analyzed. Study Design: Triple-blind crossover randomized clinical trial. Eighteen patients underwent bilateral removal of impacted lower third molars using 0.5% bupivacaine or 4% articaine in two different appointments. Preoperative, intraoperative and postoperative variables were recorded. Differences were assessed with McNemar tests and repeated measures ANOVA tests. Results: Both solutions exhibited similar latency times and intraoperative efficacy. Statistical significant lower pain levels were observed with bupivacaine between the fifth (p=0.011) and the ninth (p=0.007) postoperative hours. Bupivacaine provided significantly longer lasting soft tissue anesthesia (p<0.05). Systolic blood pressure and heart rate values were significantly higher with articaine. Conclusions: Bupivacaine could be a valid alternative to articaine especially due to its early postoperative pain prevention ability.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

The aim of this article was to study the effect of virtual-reality exposure to situations that are emotionally significant for patients with eating disorders (ED) on the stability of body-image distortion and body-image dissatisfaction. A total of 85 ED patients and 108 non-ED students were randomly exposed to four experimental virtual environments: a kitchen with low-calorie food, a kitchen with high-calorie food, a restaurant with low-calorie food, and a restaurant with high-calorie food. In the interval between the presentation of each situation, body-image distortion and body-image dissatisfaction were assessed. Several 2 x 2 x 2 repeated measures analyses of variance (high-calorie vs. low-calorie food x presence vs. absence of people x ED group vs. control group) showed that ED participants had significantly higher levels of body-image distortion and body dissatisfaction after eating high-calorie food than after eating low-calorie food, while control participants reported a similar body image in all situations. The results suggest that body-image distortion and body-image dissatisfaction show both trait and state features. On the one hand, ED patients show a general predisposition to overestimate their body size and to feel more dissatisfied with their body image than controls. On the other hand, these body-image disturbances fluctuate when participants are exposed to virtual situations that are emotionally relevant for them.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

This study examined the independent effect of skewness and kurtosis on the robustness of the linear mixed model (LMM), with the Kenward-Roger (KR) procedure, when group distributions are different, sample sizes are small, and sphericity cannot be assumed. Methods: A Monte Carlo simulation study considering a split-plot design involving three groups and four repeated measures was performed. Results: The results showed that when group distributions are different, the effect of skewness on KR robustness is greater than that of kurtosis for the corresponding values. Furthermore, the pairings of skewness and kurtosis with group size were found to be relevant variables when applying this procedure. Conclusions: With sample sizes of 45 and 60, KR is a suitable option for analyzing data when the distributions are: (a) mesokurtic and not highly or extremely skewed, and (b) symmetric with different degrees of kurtosis. With total sample sizes of 30, it is adequate when group sizes are equal and the distributions are: (a) mesokurtic and slightly or moderately skewed, and sphericity is assumed; and (b) symmetric with a moderate or high/extreme violation of kurtosis. Alternative analyses should be considered when the distributions are highly or extremely skewed and samples sizes are small.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Objective: The aim of the current study was to investigate the long-term cognitive effects of electroconvulsive therapy (ECT) in a sample of adolescent patients in whom schizophrenia spectrum disorders were diagnosed. Methods: The sample was composed of nine adolescent subjects in whom schizophrenia or schizoaffective disorder was diagnosed according to DSM-IV-TR criteria on whom ECT was conducted (ECT group) and nine adolescent subjects matched by age, socioeconomic status, and diagnostic and Positive and Negative Syndrome Scale (PANSS) total score at baseline on whom ECT was not conducted (NECT group). Clinical and neuropsychological assessments were carried out at baseline before ECT treatment and at 2-year follow-up. Results: Significant differences were found between groups in the number of unsuccessful medication trials. No statistically significant differences were found between the ECT group and theNECT group in either severity as assessed by the PANSS, or in any cognitive variables at baseline.At follow-up, both groups showed significant improvement in clinical variables (subscales of positive, general, and total scores of PANSS and Clinical Global Impressions-Improvement). In the cognitive assessment at follow-up, significant improvement was found in both groups in the semantic category of verbal fluency task and digits forward. However, no significant differences were found between groups in any clinical or cognitive variable at follow-up. Repeated measures analysis found no significant interaction of time · group in any clinical or neuropsychological measures. Conclusions: The current study showed no significant differences in change over time in clinical or neuropsychological variables between the ECT group and the NECT group at 2-year follow-up. Thus, ECT did not show any negative influence on long-term neuropsychological variables in our sample.

Relevância:

60.00% 60.00%

Publicador:

Resumo:

Background: Intraocular pressure (IOP) is the pressure inside the eye that helps to maintain the integrity and the suitable form of the ocular globe. Precise and accurate measures of IOP are needed for the diagnosis as well as follow-up of glaucoma. In daily clinical practice, Goldmann applanation tonometer (GAT) and Non-contact tonometer (NCT) are the most common devices for measuring IOP. A close agreement between these methods has been showed, particularly in normotensive patients and a poor agreement, especially when IOP levels are above the normal range. Ophthalmologists have noticed a poor agreement between NCT and GAT, observing that by using NCT and after comparing with GAT, there is an overestimation of IOP readings, and particularly it occurs when the eyes are tearful. Previous studies investigate the effect of tears in Non-contact tonometer readings by the instillation of artificial tears, concluding in one of the studies that the variation was less than 1mmHg and not clinically significant, in contrast with another study which the increases were sadistically significant. Tear menisci are a thin strip of tear fluid located between the bulbar conjunctiva and the eyelid margins. We think that the overestimation of IOP readings using NCT could be due to the presence of a higher volume of tear in the lower tear meniscus which might cause an optical interference in the optoelectronic applanation monitoring system of this deviceObjectives: To research the influence of a certain volume of fluid in the lower tear meniscus on IOP measurements using the NCT in healthy eyes. Moreover, to investigate the agreement between IOP readings obtained by NCT and GAT in the presence and absence of this volume of fluidMethods: The study design will be transversal for diagnostic tests of repeated measures. We will study patients with no ocular pathology and IOP<21mmHg. It will consist in the measurement of IOP using NCT before and after the instillation of COLIRCUSÍ FLUOTEST, used as a volume of fluid in the lower tear meniscus, to observe if there will be differences using the paired t-test. Moreover, we will take IOP measures by GAT in order to know the agreement between these methods after and before the application of these eyedrops, using the ICC (intraclass correlation coefficient) and the Bland-Altmann method

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper contributes to the study of tacit collusion by analyzing infinitely repeated multiunit uniform price auctions in a symmetric oligopoly with capacity constrained firms. Under both the Market Clearing and Maximum Accepted Price rules of determining the uniform price, we show that when each firm sets a price-quantity pair specifying the firm's minimum acceptable price and the maximum quantity the firm is willing to sell at this price, there exists a range of discount factors for which the monopoly outcome with equal sharing is sustainable in the uniform price auction, but not in the corresponding discriminatory auction. Moreover, capacity withholding may be necessary to sustain this out-come. We extend these results to the case where firms may set bids that are arbitrary step functions of price-quantity pairs with any finite number of price steps. Surprisingly, under the Maximum Accepted Price rule, firms need employ no more than two price steps to minimize the value of the discount factor