7 resultados para PRESSURE-VOLUME-TEMPERATURE

em Consorci de Serveis Universitaris de Catalunya (CSUC), Spain


Relevância:

100.00% 100.00%

Publicador:

Resumo:

Objective: To compare pressure–volume (P–V) curves obtained with the Galileo ventilator with those obtained with the CPAP method in patients with ALI or ARDS receiving mechanical ventilation. P–V curves were fitted to a sigmoidal equation with a mean R2 of 0.994 ± 0.003. Lower (LIP) and upper inflection (UIP), and deflation maximum curvature (PMC) points calculated from the fitted variables showed a good correlation between methods with high intraclass correlation coefficients. Bias and limits of agreement for LIP, UIP and PMC obtained with the two methods in the same patient were clinically acceptable.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The influence of the pressure of a chemically inert carrier gas on the nucleation rate is one of the biggest puzzles in the research of gas-liquid nucleation. Experiments can show a positive effect, a negative effect, or no effect at all. The same experiment may show both trends for the same substance depending on temperature, or for different substances at the same temperature. We show how this ambiguous effect naturally arises from the competition of two contributions: nonisothermal effects and pressure-volume work. Our model clarifies seemingly contradictory experimental results and quantifies the variation of the nucleation ability of a substance in the presence of an ambient gas. Our findings are corroborated by molecular dynamics simulations and might have important implications since nucleation in experiments, technical applications, and nature practically always occurs in the presence of an ambient gas.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Poder mesurar i enregistrar diferents tipus de magnituds com pressió, força, temperatura etc. s’ha convertit en una necessitat per moltes aplicacions actuals. Aquestes magnituds poden tenir procedències molt diverses, tals com l’entorn, o poden ser generades per sistemes mecànics, elèctrics, etc. Per tal de poder adquirir aquestes magnituds, s’utilitzen els sistemes d’adquisició de dades. Aquests sistemes, prenen mostres analògiques del món real, i les transformen en dades digitals que poden ser manipulades per un sistema electrònic. Pràcticament qualsevol magnitud es pot mesurar utilitzant el sensor adient. Una magnitud molt utilitzada en sistemes d’adquisició de dades, és la temperatura. Els sistemes d’adquisició de temperatures estan molt generalitzats, i podem trobar-los com a sistemes, on l’objectiu és mostrar les dades adquirides, o podem trobar-los formant part de sistemes de control, aportant uns inputs necessaris per el seu correcte funcionament, garantir-ne l’estabilitat, seguretat etc. Aquest projecte, promogut per l’empresa Elausa, s’encarregarà d’adquirir, el senyal d’entrada de 2 Termoparells. Aquests mesuraran temperatures de circuits electrònics, que es trobaran dintre la càmera climàtica de Elausa, sotmesos a diferents condicions de temperatura, per tal de rebre l’homologació del circuit. El sistema haurà de poder mostrar les dades adquirides en temps real, i emmagatzemar-les en un PC que estarà ubicat en una oficina, situada a uns 30 m de distància de la sala on es farà el test. El sistema constarà d’un circuit electrònic que adquirirà, i condicionarà el senyal de sortida dels termoparells, per adaptar-lo a la tensió d’entrada d’un convertidor analògic digital, del microcontrolador integrat en aquesta placa. Seguidament aquesta informació, s’enviarà a través d’un mòdul transmissor de radiofreqüència, cap al PC on es visualitzaran les dades adquirides. Els objectius plantejats són els següents: - Dissenyar el circuit electrònic d’adquisició i condicionament del senyal. - Dissenyar, fabricar i muntar el circuit imprès de la placa d’adquisició. - Realitzar el programa de control del microcontrolador. - Realitzar el programa per presentar i desar les dades en un PC. - El sistema ha d’adquirir 2 temperatures, a través de Termoparells amb un rang d’entrada de -40ºC a +240ºC - S’ha de transmetre les dades via R.F. Els resultats del projecte han estat satisfactoris i s’han complert els objectius plantejats.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The liquid-liquid critical point scenario of water hypothesizes the existence of two metastable liq- uid phases low-density liquid (LDL) and high-density liquid (HDL) deep within the supercooled region. The hypothesis originates from computer simulations of the ST2 water model, but the stabil- ity of the LDL phase with respect to the crystal is still being debated. We simulate supercooled ST2 water at constant pressure, constant temperature, and constant number of molecules N for N ≤ 729 and times up to 1 μs. We observe clear differences between the two liquids, both structural and dynamical. Using several methods, including finite-size scaling, we confirm the presence of a liquid-liquid phase transition ending in a critical point. We find that the LDL is stable with respect to the crystal in 98% of our runs (we perform 372 runs for LDL or LDL-like states), and in 100% of our runs for the two largest system sizes (N = 512 and 729, for which we perform 136 runs for LDL or LDL-like states). In all these runs, tiny crystallites grow and then melt within 1 μs. Only for N ≤ 343 we observe six events (over 236 runs for LDL or LDL-like states) of spontaneous crystal- lization after crystallites reach an estimated critical size of about 70 ± 10 molecules.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We present a complete Raman spectroscopic study in two structurally well-defined diradical species of different lengths incorporating oligo p-phenylene vinylene bridges between two polychlorinated triphenylmethyl radical units, a disposition that allows sizeable conjugation between the two radicals through and with the bridge. The spectroscopic data are interpreted and supported by quantum chemical calculations. We focus the attention on the Raman frequency changes, interpretable in terms of: (i) bridge length (conjugation length); (ii) bridge conformational structure; and (iii) electronic coupling between the terminal radical units with the bridge and through the bridge, which could delineate through-bond spin polarization, or spin delocalization. These items are addressed by using the"oligomer approach" in conjunction with pressure and temperature dependent Raman spectroscopic data. In summary, we have attempted to translate the well-known strategy to study the electron (charge) structure of π−conjugated molecules by Raman spectroscopy to the case of electron (spin) interactions via the spin delocalization mechanism.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We analyze the stability of small bubbles in a closed system with fixed volume, temperature, and number of molecules. We show that there exists a minimum stable size of a bubble. Thus there exists a range of densities where no stable bubbles are allowed and the system has a homogeneous density which is lower than the coexistence density of the liquid. This becomes possible due to the finite liquid compressibility. Capillary analysis within the developed"modified bubble" model illustrates that the existence of the minimum bubble size is associated to the compressibility and it is not possible when the liquid is strictly incompressible. This finding is expected to have very important implications in cavitation and boiling.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Poder mesurar i enregistrar diferents tipus de magnituds com pressió, força, temperatura etc. s’ha convertit en una necessitat per moltes aplicacions actuals. Aquestes magnituds poden tenir procedències molt diverses, tals com l’entorn, o poden ser generades per sistemes mecànics, elèctrics, etc. Per tal de poder adquirir aquestes magnituds, s’utilitzen els sistemes d’adquisició de dades. Aquests sistemes, prenen mostres analògiques del món real, i les transformen en dades digitals que poden ser manipulades per un sistema electrònic. Pràcticament qualsevol magnitud es pot mesurar utilitzant el sensor adient. Una magnitud molt utilitzada en sistemes d’adquisició de dades, és la temperatura. Els sistemes d’adquisició de temperatures estan molt generalitzats, i podem trobar-los com a sistemes, on l’objectiu és mostrar les dades adquirides, o podem trobar-los formant part de sistemes de control, aportant uns inputs necessaris per el seu correcte funcionament, garantir-ne l’estabilitat, seguretat etc. Aquest projecte, promogut per l’empresa Elausa, s’encarregarà d’adquirir, el senyal d’entrada de 2 Termoparells. Aquests mesuraran temperatures de circuits electrònics, que es trobaran dintre la càmera climàtica de Elausa, sotmesos a diferents condicions de temperatura, per tal de rebre l’homologació del circuit. El sistema haurà de poder mostrar les dades adquirides en temps real, i emmagatzemar-les en un PC que estarà ubicat en una oficina, situada a uns 30 m de distància de la sala on es farà el test. El sistema constarà d’un circuit electrònic que adquirirà, i condicionarà el senyal de sortida dels termoparells, per adaptar-lo a la tensió d’entrada d’un convertidor analògic digital, del microcontrolador integrat en aquesta placa. Seguidament aquesta informació, s’enviarà a través d’un mòdul transmissor de radiofreqüència, cap al PC on es visualitzaran les dades adquirides. Els objectius plantejats són els següents: - Dissenyar el circuit electrònic d’adquisició i condicionament del senyal. - Dissenyar, fabricar i muntar el circuit imprès de la placa d’adquisició. - Realitzar el programa de control del microcontrolador. - Realitzar el programa per presentar i desar les dades en un PC. - El sistema ha d’adquirir 2 temperatures, a través de Termoparells amb un rang d’entrada de -40ºC a +240ºC - S’ha de transmetre les dades via R.F. Els resultats del projecte han estat satisfactoris i s’han complert els objectius plantejats.