12 resultados para Needle biopsy
em Consorci de Serveis Universitaris de Catalunya (CSUC), Spain
Resumo:
The clinical picture of 15 patients (10 male, five female) with amyloid arthropathy secondary to chronic renal failure treated with haemodialysis has been studied. The average period of haemodialysis was 10.8 years. Joint symptoms appeared between three and 13 years after starting haemodialysis. No patient had renal amyloidosis. Early symptoms were varied and often overlapped: knee swelling (seven patients), painful and stiff shoulders (seven), and carpal tunnel syndrome (six) were the most prominent. Follow up showed extension to other joints. Joint effusions were generally of the non-inflammatory type. Radiologically, geodes and erosions of variable sizes were seen in the affected joints, which can develop into a destructive arthropathy. Amyloid was found in abdominal fat in three of the 12 patients on whom a needle aspiration was performed. Four of 12 patients showed changes compatible with amyloid infiltration in the echocardiogram. One patient had amyloid in the gastric muscular layer, another in the colon mucus, and two of four in rectal biopsy specimens. Amyloid deposits showed the presence of beta 2 microglobulin in 10 patients. The clinical and radiological picture was similar to the amyloid arthropathy associated with multiple myeloma. These patients can develop systemic amyloidosis.
Resumo:
The clinical picture of 15 patients (10 male, five female) with amyloid arthropathy secondary to chronic renal failure treated with haemodialysis has been studied. The average period of haemodialysis was 10.8 years. Joint symptoms appeared between three and 13 years after starting haemodialysis. No patient had renal amyloidosis. Early symptoms were varied and often overlapped: knee swelling (seven patients), painful and stiff shoulders (seven), and carpal tunnel syndrome (six) were the most prominent. Follow up showed extension to other joints. Joint effusions were generally of the non-inflammatory type. Radiologically, geodes and erosions of variable sizes were seen in the affected joints, which can develop into a destructive arthropathy. Amyloid was found in abdominal fat in three of the 12 patients on whom a needle aspiration was performed. Four of 12 patients showed changes compatible with amyloid infiltration in the echocardiogram. One patient had amyloid in the gastric muscular layer, another in the colon mucus, and two of four in rectal biopsy specimens. Amyloid deposits showed the presence of beta 2 microglobulin in 10 patients. The clinical and radiological picture was similar to the amyloid arthropathy associated with multiple myeloma. These patients can develop systemic amyloidosis.
Resumo:
The accuracy of peritoneoscopy and liver biopsy in the diagnosis of hepatic cirrhosis was compared in 473 consecutive patients submitted to both procedures. One hundred and fifty-two of them had cirrhosis diagnosed by one or both methods. There was 73% agreement between the two procedures. `Apparent' false-negative results were 17·7% for peritoneoscopy and 9·3% for liver biopsy. The incidence of false-negative results in the diagnosis of cirrhosis can be reduced by combining both procedures.
Resumo:
The characterisation of lymphocytes from liver biopsies indicates that 'activated' T lymphocytes are present in the liver in alcohol induced hepatitis, chronic active hepatitis (HBS+ve and -ve), and in primary biliary cirrhosis but not in inactive cirrhosis, chronic persistent hepatitis, extrahepatic and drug induced cholestasis. A greater percentage of lymphocytes bear Fc-receptors in chronic active hepatitis than in alcohol induced hepatitis or cholestatic liver disease. The concentration of 'activated' T cells in the peripheral blood in all groups studied was within the normal range, suggesting that the 'activated' T cells found in the liver were reacting to either native or foreign antigens within the liver. The data on Fc-receptor bearing cells are consistent with the involvement of antibody assisted K cell mediated cytotoxicity in chronic active hepatitis.
Resumo:
To assess the diagnostic usefulness of temporal artery biopsy in temporal arteritis (TA) and establish clinical features capable of predicting its positivity we have retrospectively studied the biopsy specimens and the clinical features of 103 patients who had undergone temporal artery biopsy. Temporal artery biopsy reached a positive predictive value of 90.2% with respect to the final diagnosis based on the criteria proposed by Ellis and Ralston and the clinical course. The simultaneous presence of recent onset headache, jaw claudication, and abnormalities of the temporal arteries on physical examination had a specificity of 94.8% with respect to the histological diagnosis and of 100% with respect to final diagnosis. The presence of any of these clinical features, though of little specificity (34.4%), had a sensitivity of 100% with respect to histological diagnosis, selecting a group of patients in whom temporal artery biopsy has more discriminative value.
Resumo:
To evaluate the efficacy of endorectal Magnetic Resonance Imaging (MRI) and Magnetic Resonance Spetroscopic Imaging (MRSI) combined with total prostate-specific antigen (tPSA) and free prostate-specific antigen (fPSA) in selecting candidates for biopsy. Subjects and Methods: 246 patients with elevated tPSA (median: 7.81 ng/ml) underwent endorectal MRI and MRSI before Transrectal Ultrasound (TRUS) biopsy (10 peripheral + 2 central cores); patients with positive biopsies were treated with radical intention; those with negative biopsies were followed up and underwent MRSI before each additional biopsy if tPSA rose persistently. Mean follow-up: 27.6 months. We compared MRI, MRSI, tPSA, and fPSA with histopathology by sextant and determined the association between the Gleason score and MRI and MRSI. We determined the most accurate combination to detect prostate cancer (PCa) using receiver operating curves; we estimated the odds ratios (OR) and calculated sensitivity, specificity, and positive and negative predictive values. Results: No difference in tPSA was found between patients with and without PCa (p = 0.551). In the peripheral zone, the risk of PCa increased with MRSI grade; patients with high-grade MRSI had the greatest risk of PCa over time (OR = 328.6); the model including MRI, MRSI, tPSA, and fPSA was more accurate (Area under Curve: AUC = 95.7%) than MRI alone (AUC = 85.1%) or fPSA alone (AUC = 78.1%), but not than MRSI alone (94.5%). In the transitional zone, the model was less accurate (AUC = 84.4%). The association (p = 0.005) between MRSI and Gleason score was significant in both zones. Conclusions: MRSI is useful in patients with elevated tPSA. High-grade MRSI lesions call for repeated biopsies. Men with negative MRSI may forgo further biopsies because a significantly high Gleason lesion is very unlikely
Resumo:
Objectives: The purpose of this study is to determine the possible differences in deflection between two needles of same length and external gauge but with different internal gauges during truncal block of the inferior alveolar nerve. The initial working hypothesis was that greater deflection may be expected with larger internal gauge needles. Study design: Four clinicians subjected 346 patients to inferior alveolar nerve block and infiltrating anesthesia of the buccal nerve trajectory for the surgical or conventional extraction of the lower third molar. A nonautoaspirating syringe system with 2 types of needle was used: a standard 27-gauge x 35-mm needle with an internal gauge of 0.215 mm or an XL Monoprotect® 27-gauge x 35-mm needle with an internal gauge of 0.265 mm. The following information was systematically recorded for each patient: needle type, gender, anesthetic technique (direct or indirect truncal block) and the number of bone contacts during the procedure, the patient-extraction side, the practitioner performing the technique, and blood aspiration (either positive or negative). Results: 346 needles were used in total. 190 were standard needles (27-gauge x 35-mm needle with an internal gauge of 0.215 mm) and 156 were XL Monoprotect®. Incidence of deflection was observed in 49.1% of cases (170 needles) where 94 were standard needles and 76 XL Monoprotect®. Needle torsion ranged from 0º and 6º. Conclusions: No significant differences were recorded in terms of deflection and internal gauge, operator, patient-extraction side, the anesthetic technique involved and the number of bone contacts during the procedure
Resumo:
Combining headspace (HS) sampling with a needle-trap device (NTD) to determine priority volatile organic compounds (VOCs) in water samples results in improved sensitivity and efficiency when compared to conventional static HS sampling. A 22 gauge stainless steel, 51-mm needle packed with Tenax TA and Carboxen 1000 particles is used as the NTD. Three different HS-NTD sampling methodologies are evaluated and all give limits of detection for the target VOCs in the ng L−1 range. Active (purge-and-trap) HS-NTD sampling is found to give the best sensitivity but requires exhaustive control of the sampling conditions. The use of the NTD to collect the headspace gas sample results in a combined adsorption/desorption mechanism. The testing of different temperatures for the HS thermostating reveals a greater desorption effect when the sample is allowed to diffuse, whether passively or actively, through the sorbent particles. The limits of detection obtained in the simplest sampling methodology, static HS-NTD (5 mL aqueous sample in 20 mL HS vials, thermostating at 50 °C for 30 min with agitation), are sufficiently low as to permit its application to the analysis of 18 priority VOCs in natural and waste waters. In all cases compounds were detected below regulated levels
Resumo:
Needle trap devices (NTDs) are a relatively new and promising tool for headspace (HS) analysis. In this study, a dynamic HS sampling procedure is evaluated for the determination of volatile organic compounds (VOCs) in whole blood samples. A full factorial design was used to evaluate the influence of the number of cycles and incubation time and it is demonstrated that the controlling factor in the process is the number of cycles. A mathematical model can be used to determine the most appropriate number of cycles required to adsorb a prefixed amount of VOCs present in the HS phase whenever quantitative adsorption is reached in each cycle. Matrix effect is of great importance when complex biological samples, such as blood, are analyzed. The evaluation of the salting out effect showed a significant improvement in the volatilization of VOCs to the HS in this type of matrices. Moreover, a 1:4 (blood:water) dilution is required to obtain quantitative recoveries of the target analytes when external calibration is used. The method developed gives detection limits in the 0.020–0.080 μg L−1 range (0.1–0.4 μg L−1 range for undiluted blood samples) with appropriate repeatability values (RSD < 15% at high level and <23% at LOQ level). Figure of merits of the method can be improved by using a smaller phase ratio (i.e., an increase in the blood volume and a decrease in the HS volume), which lead to lower detection limits, better repeatability values and greater sensibility. Twenty-eight blood samples have been evaluated with the proposed method and the results agree with those indicated in other studies. Benzene was the only target compound that gave significant differences between blood levels detected in volunteer non-smokers and smokers
Resumo:
Aquest project es situa dins del marc del CNM-IMB (CSIC). Consisteix en el disseny d'un sistema de biòpsia mamaria en temps real. Per realitzar aquest sistema s’ha dissenyat una plataforma de lectura, test y caracterització pel ROIC Medipix2 que es basa en el microprocessador LEON3 i és programat sobre una FPGA.
Mejora diagnóstica de hepatopatías de afectación difusa mediante técnicas de inteligencia artificial
Resumo:
The automatic diagnostic discrimination is an application of artificial intelligence techniques that can solve clinical cases based on imaging. Diffuse liver diseases are diseases of wide prominence in the population and insidious course, yet early in its progression. Early and effective diagnosis is necessary because many of these diseases progress to cirrhosis and liver cancer. The usual technique of choice for accurate diagnosis is liver biopsy, an invasive and not without incompatibilities one. It is proposed in this project an alternative non-invasive and free of contraindications method based on liver ultrasonography. The images are digitized and then analyzed using statistical techniques and analysis of texture. The results are validated from the pathology report. Finally, we apply artificial intelligence techniques as Fuzzy k-Means or Support Vector Machines and compare its significance to the analysis Statistics and the report of the clinician. The results show that this technique is significantly valid and a promising alternative as a noninvasive diagnostic chronic liver disease from diffuse involvement. Artificial Intelligence classifying techniques significantly improve the diagnosing discrimination compared to other statistics.
Resumo:
Emergent molecular measurement methods, such as DNA microarray, qRTPCR, andmany others, offer tremendous promise for the personalized treatment of cancer. Thesetechnologies measure the amount of specific proteins, RNA, DNA or other moleculartargets from tumor specimens with the goal of “fingerprinting” individual cancers. Tumorspecimens are heterogeneous; an individual specimen typically contains unknownamounts of multiple tissues types. Thus, the measured molecular concentrations resultfrom an unknown mixture of tissue types, and must be normalized to account for thecomposition of the mixture.For example, a breast tumor biopsy may contain normal, dysplastic and cancerousepithelial cells, as well as stromal components (fatty and connective tissue) and bloodand lymphatic vessels. Our diagnostic interest focuses solely on the dysplastic andcancerous epithelial cells. The remaining tissue components serve to “contaminate”the signal of interest. The proportion of each of the tissue components changes asa function of patient characteristics (e.g., age), and varies spatially across the tumorregion. Because each of the tissue components produces a different molecular signature,and the amount of each tissue type is specimen dependent, we must estimate the tissuecomposition of the specimen, and adjust the molecular signal for this composition.Using the idea of a chemical mass balance, we consider the total measured concentrationsto be a weighted sum of the individual tissue signatures, where weightsare determined by the relative amounts of the different tissue types. We develop acompositional source apportionment model to estimate the relative amounts of tissuecomponents in a tumor specimen. We then use these estimates to infer the tissuespecificconcentrations of key molecular targets for sub-typing individual tumors. Weanticipate these specific measurements will greatly improve our ability to discriminatebetween different classes of tumors, and allow more precise matching of each patient tothe appropriate treatment