10 resultados para Increased Oxygen-demand
em Consorci de Serveis Universitaris de Catalunya (CSUC), Spain
Resumo:
We determined the capacity of transplanted beta cells to modify their replication and mass when stimulated by changes in metabolic demand. Five groups of Lewis rats were studied: group 1 (Tx-Px) had a 95% pancreatectomy 14 d after transplantation of 500 islets; group 2 (Px-Tx) had a 95% pancreatectomy 14 d before transplantation of 500 islets; group 3 (Tx) was transplanted with 500 islets; group 4 (Px) had a 95% pancreatectomy; and group 5 (normal) was neither transplanted nor pancreatectomized. Blood glucose was normal in Tx-Px and Tx groups at all times. Px-Tx and Px groups developed severe hyperglycemia after pancreatectomy that was corrected in Px-Tx group in 83% of rats 28 d after transplantation. Replication of transplanted beta cells increased in Tx-Px (1.15 +/- 0.12%) and Px-Tx (0.85 +/- 0.12%) groups, but not in Tx group (0.64 +/- 0.07%) compared with normal pancreatic beta cells (0.38 +/- 0.05%) (P < 0.001). Mean beta cell size increased in Tx-Px (311 +/- 14 microns2) and Px-Tx (328 +/- 13 microns2) groups compared with Tx (252 +/- 12 microns2) and normal (239 +/- 9 microns2) groups (P < 0.001). Transplanted beta cell mass increased in Tx-Px (1.87 +/- 0.51 mg) and Px-Tx (1.55 +/- 0.21 mg) groups compared with Tx group (0.78 +/- 0.17 mg) (P < 0.05). In summary, changes in transplanted beta cells prevented the development of hyperglycemia in Tx-Px rats. Transplanted beta cells responded to increased metabolic demand increasing their beta cell mass.
Resumo:
Currently, acoustic isolation is one of the problems raised with building construction in Spain. The publication of the Basic Document for the protection against noise of the Technical Building Code has increased the demand of comfort for citizens. This has created the need to seek new composite materials that meet the new required acoustical building codes. In this paper we report the results of the newly developed composites that are able to improve the acoustic isolation of airborne noise. These composites were prepared from polypropylene (PP) reinforced with mechanical pulp fibers from softwood (Pinus radiata). Mechanical and acoustical properties of the composites from mechanical pulp (MP) and polypropylene (PP) have been investigated and compared to fiberglass (FG) composites. MP composites had lower tensile properties compared with FG composites, although these properties can be improved by incorporation of a coupling agent. The results of acoustical properties of MP composites were reported and compared with the conventional composites based on fiberglass and gypsum plasterboards. Finally, we suggest the application of MP composites as a light-weight building material to reduce acoustic transmitions
Resumo:
Activity decreases, or deactivations, of midline and parietal cortical brain regions are routinely observed in human functional neuroimaging studies that compare periods of task-based cognitive performance with passive states, such as rest. It is now widely held that such task-induced deactivations index a highly organized"default-mode network" (DMN): a large-scale brain system whose discovery has had broad implications in the study of human brain function and behavior. In this work, we show that common task-induced deactivations from rest also occur outside of the DMN as a function of increased task demand. Fifty healthy adult subjects performed two distinct functional magnetic resonance imaging tasks that were designed to reliably map deactivations from a resting baseline. As primary findings, increases in task demand consistently modulated the regional anatomy of DMN deactivation. At high levels of task demand, robust deactivation was observed in non-DMN regions, most notably, the posterior insular cortex. Deactivation of this region was directly implicated in a performance-based analysis of experienced task difficulty. Together, these findings suggest that task-induced deactivations from rest are not limited to the DMN and extend to brain regions typically associated with integrative sensory and interoceptive processes.
Resumo:
Biofilters degrade only a small fraction of the natural organic matter (NOM) contained in seawater which is the leading cause of biofouling in downstream processes. This work studies the effects of chemical additions on NOM biodegradation by biofilters. In this work, biofiltration of seawater with an empty bed contact time (EBCT) of 6 min and a hydraulic loading rate of 10 m h-1 reduces the biological oxygen demand (BOD7) by 8%, the dissolved organic carbon (DOC) by 6% and the UV absorbance at 254 nm (A254) by 7%. Different amounts of ammonium chloride are added to the seawater (up to twice the total dissolved nitrogen in untreated seawater) to study its possible effect on the removal of NOM by a pilot-scale biofilter. Seawater is amended with different amounts of easily biodegradable dissolved organic carbon (BDOC) supplied as sodium acetate (up to twice the DOC) for the same purpose. The results of this work reveal that the ammonium chloride additions do not significantly affect NOM removal and the sodium acetate is completely consumed by the biofiltration process. For both types of chemical additions, the BOD7, DOC and A254 in the outlet stream of the biofilter are similar to the values for the untreated control. These results indicate that this biofilter easily removes the BDOC from the seawater when the EBCT is not above 6 min. Furthermore, nitrogen does not limit the NOM biodegradation in seawater under these experimental conditions.
Resumo:
Clogging, measured through head loss across filters, and the filtration quality of different filters using different effluents were studied. The filters used were: 115, 130, and 200 m disc filters; 98, 115, 130, and 178 m screen filters; and a sand filter filled with a single layer of sand with an effective diameter of 0.65 mm. The filters were used with a meat industry effluent and secondary and tertiary effluents of two wastewater treatment plants. It was observed that clogging depended on the type of effluent. With the meat industry effluent, the poorest quality effluent, disc filters clogged more than the other filter types. When the wastewater treatment plant effluents were used, the disc filters showed less frequent clogging. Several physical and chemical parameters, such as total suspended solids, chemical oxygen demand, turbidity, electrical conductivity, pH, and number of particles, were analyzed in the effluents at the entry and exit points of the filters. In general, filters did not reduce the values of the main clogging parameters to a great degree. It was found that the parameter that explained the clogging, expressed as Boucher’s filterability index, was different depending on the type of effluent and filter. The best quality of filtration was achieved with a sand filter when the meat industry effluent was used. No significant differences were observed between the quality of filtration of disc and screen filters when operating with the secondary and tertiary effluents
Resumo:
The expansion of broadband speed and coverage over IP technology, which extend over transport and terminal access networks, has increased the demand for applications and content which by being provided over it, uniformly give rise to convergence. These shifts in technologies and enterprise business models are giving rise to the necessity for changing the perspective and scope of the Universal Service and of the regulation frameworks, with this last one based in the same principles as always but varying its application. Several aspects require special and renewed attention, such as the definition of relevant markets and dominant operators, the role of packages, interconnection of IP networks, network neutrality, the use of the spectrum with a vision of value for the citizenship, the application of the competition framework, new forms of licensing, treatment of the risk in the networks, changes in the regulatory authorities, amongst others. These matters are treated from the perspective of the actual trends in the world and its conceptual justification.
Resumo:
One of the most popular options for promoting public transport use is the provision of an integrated and high quality public transport system. This was the strategy adopted by the regional government in Madrid in 1986 and since then public transport patronage has increased by more than 50%. This paper has two objectives. The first is to identify the factors underlying the significant increase in the demand for public transport in Madrid. To do this we estimate an aggregate demand function for bus and underground trips, which allows us to obtain the demand elasticities with respect to the main attributes of public transport services and also to calculate the long-term impact of changes in those explanatory variables on patronage. The second objective is to evaluate the impact on revenue derived from the introduction of the travel card scheme, and to discuss the consequences on revenue of changes in the relative fare levels of different types of ticket without substantially affecting patronage. This latter issue is addressed by estimating a matrix of own and cross-price elasticities for different ticket types.
Resumo:
Increased production of reactive oxygen species (ROS) in mitochondria underlies major systemic diseases, and this clinical problem stimulates a great scientific interest in the mechanism of ROS generation. However, the mechanism of hypoxia-induced change in ROS production is not fully understood. To mathematically analyze this mechanism in details, taking into consideration all the possible redox states formed in the process of electron transport, even for respiratory complex III, a system of hundreds of differential equations must be constructed. Aimed to facilitate such tasks, we developed a new methodology of modeling, which resides in the automated construction of large sets of differential equations. The detailed modeling of electron transport in mitochondria allowed for the identification of two steady state modes of operation (bistability) of respiratory complex III at the same microenvironmental conditions. Various perturbations could induce the transition of respiratory chain from one steady state to another. While normally complex III is in a low ROS producing mode, temporal anoxia could switch it to a high ROS producing state, which persists after the return to normal oxygen supply. This prediction, which we qualitatively validated experimentally, explains the mechanism of anoxia-induced cell damage. Recognition of bistability of complex III operation may enable novel therapeutic strategies for oxidative stress and our method of modeling could be widely used in systems biology studies.
Resumo:
Improving educational quality is an important public policy goal. However, its success requires identifying factors associated with student achievement. At the core of these proposals lies the principle that increased public school quality can make school system more efficient, resulting in correspondingly stronger performance by students. Nevertheless, the public educational system is not devoid of competition which arises, among other factors, through the efficiency of management and the geographical location of schools. Moreover, families in Spain appear to choose a school on the grounds of location. In this environment, the objective of this paper is to analyze whether geographical space has an impact on the relationship between the level of technical quality of public schools (measured by the efficiency score) and the school demand index. To do this, an empirical application is performed on a sample of 1,695 public schools in the region of Catalonia (Spain). This application shows the effects of spatial autocorrelation on the estimation of the parameters and how these problems are addressed through spatial econometrics models. The results confirm that space has a moderating effect on the relationship between efficiency and school demand, although only in urban municipalities.
Resumo:
Two experimental studies evaluated the effect of aerobic and membrane aeration changes on sludge properties, biological nutrient removal and filtration processes in a pilot plant membrane bioreactor. The optimal operating conditions were found at an aerobic dissolved oxygen set-point (DO) of 0.5mgO2L-1 and a membrane specific aeration demand (SADm) of 1mh-1, where membrane aeration can be used for nitrification. Under these conditions, a total flow reduction of 42% was achieved (75% energy reduction) without compromising nutrient removal efficiencies, maintaining sludge characteristics and controlled filtration. Below these optimal operating conditions, the nutrient removal efficiency was reduced, increasing 20% for soluble microbial products, 14% for capillarity suction time and reducing a 15% for filterability. Below this DO set-point, fouling increased with a transmembrane pressure 75% higher. SADm below 1mh-1 doubled the values of transmembrane pressure, without recovery after achieving the initial conditions