8 resultados para Hydrothermal electric power systems
em Consorci de Serveis Universitaris de Catalunya (CSUC), Spain
Resumo:
This paper aims to survey the techniques and methods described in literature to analyse and characterise voltage sags and the corresponding objectives of these works. The study has been performed from a data mining point of view
Resumo:
Three multivariate statistical tools (principal component analysis, factor analysis, analysis discriminant) have been tested to characterize and model the sags registered in distribution substations. Those models use several features to represent the magnitude, duration and unbalanced grade of sags. They have been obtained from voltage and current waveforms. The techniques are tested and compared using 69 registers of sags. The advantages and drawbacks of each technique are listed
Resumo:
Fault location has been studied deeply for transmission lines due to its importance in power systems. Nowadays the problem of fault location on distribution systems is receiving special attention mainly because of the power quality regulations. In this context, this paper presents an application software developed in Matlabtrade that automatically calculates the location of a fault in a distribution power system, starting from voltages and currents measured at the line terminal and the model of the distribution power system data. The application is based on a N-ary tree structure, which is suitable to be used in this application due to the highly branched and the non- homogeneity nature of the distribution systems, and has been developed for single-phase, two-phase, two-phase-to-ground, and three-phase faults. The implemented application is tested by using fault data in a real electrical distribution power system
Resumo:
This paper focus on the problem of locating single-phase faults in mixed distribution electric systems, with overhead lines and underground cables, using voltage and current measurements at the sending-end and sequence model of the network. Since calculating series impedance for underground cables is not as simple as in the case of overhead lines, the paper proposes a methodology to obtain an estimation of zero-sequence impedance of underground cables starting from previous single-faults occurred in the system, in which an electric arc occurred at the fault location. For this reason, the signal is previously pretreated to eliminate its peaks voltage and the analysis can be done working with a signal as close as a sinus wave as possible
Resumo:
The work presented in this paper belongs to the power quality knowledge area and deals with the voltage sags in power transmission and distribution systems. Propagating throughout the power network, voltage sags can cause plenty of problems for domestic and industrial loads that can financially cost a lot. To impose penalties to responsible party and to improve monitoring and mitigation strategies, sags must be located in the power network. With such a worthwhile objective, this paper comes up with a new method for associating a sag waveform with its origin in transmission and distribution networks. It solves this problem through developing hybrid methods which hire multiway principal component analysis (MPCA) as a dimension reduction tool. MPCA reexpresses sag waveforms in a new subspace just in a few scores. We train some well-known classifiers with these scores and exploit them for classification of future sags. The capabilities of the proposed method for dimension reduction and classification are examined using the real data gathered from three substations in Catalonia, Spain. The obtained classification rates certify the goodness and powerfulness of the developed hybrid methods as brand-new tools for sag classification
Resumo:
Through the history of Electrical Engineering education, vectorial and phasorial diagrams have been used as a fundamental learning tool. At present, computational power has replaced them by long data lists, the result of solving equation systems by means of numerical methods. In this sense, diagrams have been shifted to an academic background and although theoretically explained, they are not used in a practical way within specific examples. This fact may be against the understanding of the complex behavior of the electrical power systems by students. This article proposes a modification of the classical Perrine-Baum diagram construction to allowing both a more practical representation and a better understanding of the behavior of a high-voltage electric line under different levels of load. This modification allows, at the same time, the forecast of the obsolescence of this behavior and line’s loading capacity. Complementary, we evaluate the impact of this tool in the learning process showing comparative undergraduate results during three academic years
Resumo:
L’objecte del present informe és la descripció dels treballs duts a terme en l’Activitat 2 del projecte E-MAN-RES: models de simulació i càlcul per optimització i anàlisi de sensibilitat de la gestió de la demanda, per part de la Universitat Politècnica de Catalunya.
Resumo:
Contexto Una central nuclear, al igual que cualquier otro tipo de central generadora de energía eléctrica, mediante turbinas de vapor, está basada en un proceso termodinámico. El rendimiento de las mismas es función del salto entálpico del vapor, para mejorarlo las centrales están constituidas por un ciclo compound formado por turbina de alta presión y turbinas de baja presión, y un ciclo regenerativo consistente en calentar el agua de alimentación antes de su introducción a los generadores de vapor. Un ciclo regenerativo está basado en etapas de calentadores o cambiadores de calor para aprovechar al máximo la energía térmica del vapor, este proyecto está basado en la mejora y optimización del proceso de control de estos para contribuir a mejorar el rendimiento de la central. Objetivo Implementar un sistema de control que nos permita modernizar los clásicos sistemas basados en controles locales y comunicaciones analógicas. Mejorar el rendimiento del ciclo regenerativo de la central, aprovechando las mejoras tecnológicas que ofrece el mercado, tanto en el hardware como en el software de los sistemas de instrumentación y control. Optimizar el rendimiento de los lazos de control de cada uno de los elementos del ciclo regenerativo mediante estrategias de control. Procedimiento Desarrollo de un sistema de control actualizado considerando, como premisa principal, la fiabilidad del sistema, el análisis de fallos y la jerarquización del riesgo. Análisis y cálculo de los lazos de control considerando las premisas establecidas. Configuración de los lazos mediante estrategias de control que nos permitan optimizar y minimizar los efectos del fallo. Para ello se han utilizado parámetros y datos extraídos de la Central Nuclear de Ascó. Conclusiones Se ha modernizado y optimizado el sistema de control mejorando el rendimiento del ciclo regenerativo. Se ha conseguido un sistema más fiable, reduciendo el riesgo del fallo y disminuyendo los efectos de los mismos. El coste de un proyecto de estas características es inferior al de un sistema convencional y ofrece más posibilidades. Es un sistema abierto que permite utilizar e interconectar equipos de diferentes fabricantes, lo que favorece tanto el mantenimiento como las posibles ampliaciones futuras del sistema.