17 resultados para HYDROXYAPATITE IMPLANTS
em Consorci de Serveis Universitaris de Catalunya (CSUC), Spain
Resumo:
The improvement of the reliability of the contact between the osseous tissues and the implant materials has been tested by recovering the metallic implants with ceramic materials, usually calcium phosphates. In our study, the calcium phosphate recovering layers were deposited by means of a pulsed-laser deposition technique. Our aim was to to evaluate the tissue interactions established between cortical bone and titanium implants covered by five different layers, ranging from amorphous calcium phosphate to crystalline hydroxyapatite, obtained by altering the parameters of the laser ablation process. The surgical protocol of the study consisted in the simultaneous implantation of the five types of implants in both the tibial dyaphisis of three Beagle dogs, sacrificed respectively one, two and three months after the last surgical procedures. After the sacrifice, the samples were submitted to a scheduled procedure of embedding in plastic polymers without prior decalcification, in order to perform the ultrastructural studies: scanning microscopy with secondary and backscattered electrons (BS-SEM). Our observations show that both in terms of the calcified tissues appearing as a response to the presence of the different coatings and of time of recovering, the implants coated with crystalline calcium phosphate layers by laser ablation present a better result than the amorphous-calcium-phosphate-coated implants. Moreover, the constant presence of chondroid tissue, related with the mechanical induction by forces applied on the recovering area, strongly suggests that the mechanisms implied in osteointegration are related to endomembranous, rather than endochondral ossification processes
Resumo:
The improvement of the reliability of the contact between the osseous tissues and the implant materials has been tested by recovering the metallic implants with ceramic materials, usually calcium phosphates. In our study, the calcium phosphate recovering layers were deposited by means of a pulsed-laser deposition technique. Our aim was to to evaluate the tissue interactions established between cortical bone and titanium implants covered by five different layers, ranging from amorphous calcium phosphate to crystalline hydroxyapatite, obtained by altering the parameters of the laser ablation process. The surgical protocol of the study consisted in the simultaneous implantation of the five types of implants in both the tibial dyaphisis of three Beagle dogs, sacrificed respectively one, two and three months after the last surgical procedures. After the sacrifice, the samples were submitted to a scheduled procedure of embedding in plastic polymers without prior decalcification, in order to perform the ultrastructural studies: scanning microscopy with secondary and backscattered electrons (BS-SEM). Our observations show that both in terms of the calcified tissues appearing as a response to the presence of the different coatings and of time of recovering, the implants coated with crystalline calcium phosphate layers by laser ablation present a better result than the amorphous-calcium-phosphate-coated implants. Moreover, the constant presence of chondroid tissue, related with the mechanical induction by forces applied on the recovering area, strongly suggests that the mechanisms implied in osteointegration are related to endomembranous, rather than endochondral ossification processes
Resumo:
The improvement of the reliability of the contact between the osseous tissues and the implant materials has been tested by recovering the metallic implants with ceramic materials, usually calcium phosphates. In our study, the calcium phosphate recovering layers were deposited by means of a pulsed-laser deposition technique. Our aim was to to evaluate the tissue interactions established between cortical bone and titanium implants covered by five different layers, ranging from amorphous calcium phosphate to crystalline hydroxyapatite, obtained by altering the parameters of the laser ablation process. The surgical protocol of the study consisted in the simultaneous implantation of the five types of implants in both the tibial dyaphisis of three Beagle dogs, sacrificed respectively one, two and three months after the last surgical procedures. After the sacrifice, the samples were submitted to a scheduled procedure of embedding in plastic polymers without prior decalcification, in order to perform the ultrastructural studies: scanning microscopy with secondary and backscattered electrons (BS-SEM). Our observations show that both in terms of the calcified tissues appearing as a response to the presence of the different coatings and of time of recovering, the implants coated with crystalline calcium phosphate layers by laser ablation present a better result than the amorphous-calcium-phosphate-coated implants. Moreover, the constant presence of chondroid tissue, related with the mechanical induction by forces applied on the recovering area, strongly suggests that the mechanisms implied in osteointegration are related to endomembranous, rather than endochondral ossification processes
Resumo:
An analysis of silicon on insulator structures obtained by single and multiple implants by means of Raman scattering and photoluminescence spectroscopy is reported. The Raman spectra obtained with different excitation powers and wavelengths indicate the presence of a tensile strain in the top silicon layer of the structures. The comparison between the spectra measured in both kinds of samples points out the existence in the multiple implant material of a lower strain for a penetration depth about 300 nm and a higher strain for higher penetration depths. These results have been correlated with transmission electron microscopy observations, which have allowed to associate the higher strain to the presence of SiO2 precipitates in the top silicon layer, close to the buried oxide. The found lower strain is in agreement with the better quality expected for this material, which is corroborated by the photoluminescence data.
Resumo:
Calcium phosphate coatings, obtained at different deposition rates by pulsed laser deposition with a Nd:YAG laser beam of 355-nm wavelength, were studied. The deposition rate was changed from 0.043 to 1.16 /shot by modification of only the ablated area, maintaining the local fluence constant to perform the ablation process in similar local conditions. Characterization of the coatings was performed by scanning electron microscopy, x-ray diffractometry, and infrared, micro-Raman, and x-ray photoelectron spectroscopy. The coatings showed a compact surface morphology formed by glassy gains with some droplets on them. Only hydroxyapatite (HA) and alpha-tricalcium phosphate (alpha-TCP) peaks were found in the x-ray diffractograms. The relative content of alpha TCP diminished with decreasing deposition rates, and only HA peaks were found for the lowest rate. The origin of alpha TCP is discussed.
Resumo:
The plume generated by ablation of hydroxyapatite targets under ArF excimer laser irradiation has been investigated by means of fast intensified CCD-imaging and optical emission spectroscopy. Results have shown that the plume splits into two plasma clouds as it expands. Time and spatial resolved spectra have revealed that under the experiment conditions emission is mostly due to calcium neutral atoms and calcium oxide molecular radicals. Imaging of the plume with the aid of bandpass filters has demonstrated that the emissive species in the larger and faster plasma cloud are calcium neutral atoms, whereas in the smaller and slower one they are calcium oxide molecular radicals
Resumo:
ArF excimer laser pulses (193 nm, 20 ns, 150 mJ) have been focused on a hydroxyapatite (HA) target in similar conditions to those normally used for thin film deposition. Fast intensified CCD images of HA laser ablation plumes have been taken in vacuum and under different water vapor pressures ranging from 0.01 mbar to 1 mbar. Images of HA ablation in vacuum have shown a plume freely expanding at a constant velocity of 2.3 106 cm/s. HA ablation under a water vapor pressure of 0.01 mbar has revealed an expansion behavior very similar to that of ablation in vacuum. Images taken under a water vapor pressure of 0.1 mbar have shown the formation of a shock structure in the plume. Finally, HA ablation under a water vapor pressure of 1 mbar has revealed the development of some irregularities in the shape of the plume.
Resumo:
The expansion dynamics of the ablation plume generated by KrF laser irradiation of hydroxyapatite targets in a 0.1 mbar water atmosphere has been studied by fast intensified charge coupled device imaging with the aid of optical bandpass filters. The aim of the filters is to isolate the emission of a single species, which allows separate analysis of its expansion. Images obtained without a filter revealed two emissive components in the plume, which expand at different velocities for delay times of up to 1.1 ¿s. The dynamics of the first component is similar to that of a spherical shock wave, whereas the second component, smaller than the first, expands at constant velocity. Images obtained through a 520 nm filter show that the luminous intensity distribution and evolution of emissive atomic calcium is almost identical to those of the first component of the total emission and that there is no contribution from this species to the emission from the second component of the plume. The analysis through a 780 nm filter reveals that atomic oxygen partially diffuses into the water atmosphere and that there is a contribution from this species to the emission from the second component. The last species studied here, calcium oxide, was analyzed by means of a 600 nm filter. The images revealed an intensity pattern more complex than those from the atomic species. Calcium oxide also contributes to the emission from the second component. Finally, all the experiments were repeated in a Ne atmosphere. Comparison of the images revealed chemical reactions between the first component of the plume and the water atmosphere.
Resumo:
Introduction: Zygomatic implants are a good rehabilitation alternative for upper maxilla with severe bone reabsorption. These implants reduce the need for onlay-type bone grafting in the posterior sectors and for maxillary sinus lift procedures - limiting the use of bone grafts to the anterior zone of the upper jaw in those cases where grafting is considered necessary. Objective: To evaluate the survival of 101 zygomatic implants placed in upper maxilla presenting important bone reabsorption, with a follow-up of 1-72 months. Patients and methods: A retrospective study was made of 101 Zygoma® implants (Nobel Biocare, Göteborg, Sweden) placed in 54 patients with totally edentulous and atrophic upper maxilla, in the period between 1998-2004. There were 35 women and 19 men, subjected to rehabilitation in the form of fixed prostheses and overdentures using 1-2 zygomatic implants and 2-7 implants in the anterior maxillary zone. The principal study variables were smoking, a history of sinusitis, the degree of bone reabsorption, and peri-implant bone loss, among others. Results: The descriptive analysis of the 101 zygomatic implants placed in 54 patients with a mean age of 56 years (range 38-75) yielded a percentage survival of 96.04%, with four failed implants that were removed (two before and two after prosthetic loading). Nine patients were smokers, and none of the 54 subjects reported a history of sinus disorders. Discussion and conclusions: Zygomatic implants are designed for use in compromised upper maxilla. They allow the clinician to shorten the treatment time, affording an interesting alternative for fixed prosthetic rehabilitation. This study confirms that zygomatic bone offers predictable anchorage and acceptable support function for prostheses in atrophic jaws. However, these implants are not without complications. Longer-term evaluations are needed of zygomatic implant survival in order to establish a correct clinical prognosis
Resumo:
The use of implants for oral rehabilitation of edentulous spaces has recently been on the increase, which has also led to an increase in complications such as peri-implant inflammation or peri-implantitis. Chronic inflammation is a risk factor for developing oral squamous cell carcinoma (OSCC). Objectives: To review the literature of cases that associate implant placement with the development of oral cancer. Study design: We present two clinical cases and a systematic review of literature published on the relationship between oral cancer and implants. Results: We found 13 articles published between the years 1996 and 2009, referencing 18 cases in which the osseointegrated implants are associated with oral squamous cell carcinoma. Of those, 6 articles were excluded because they did not meet the inclusion criteria. Of the 18 cases reported, only 7 cases did not present a previous history of oral cancer or cancer in other parts of the body. Conclusions: Based on the review of these cases, a clear cause-effect relationship cannot be established, although it can be deduced that there is a possibility that implant treatment may constitute an irritant and/or inflammatory cofactor which contributes to the formation and/or development of OSCC.
Resumo:
Objective: An evaluation and comparison is made of the thermal increment at different implant surfaces during irradiation with CO2 and ErCr:YSGG lasers. Study design: Five threaded and impacted implants with four types of surfaces were inserted in an adult pig rib: two implants with a hydroxyapatite surface (HA)(impacted and threaded, respectively), a machined titanium surface implant (TI mach), a titanium plasma spray surface implant (TPS), and a sandblasted, acid-etched surface implant (SBAE). A 0.5-mm diameter bone defect was made in the implant apical zone, and a type-K thermocouple (Termopar)® was placed in contact with the implant. The implants were irradiated in the coronal zone of each implant with a CO2 (4 W continuous mode) and an ErCr:YSGG laser (1.5 W, pulsed mode) first without and then with refrigeration. The temperature variations at the implant apical surface were recorded. Results: An apical temperature increase was recorded in all cases during CO2 and ErCr:YSGG laser irradiation without refrigeration. However, when the ErCr:YSGG was used with a water spray, a decrease in temperature was observed in all implants. The acid-etched and sandblasted surfaces were those most affected by the thermal changes. Conclusions: The ErCr:YSGG laser with a water spray applied to the sealing cap or coronal zone of the implants does not generate thermal increments in the apical surface capable of adversely affecting osseointegration and the integrity of the peri-implant bone tissue
Resumo:
Els nous implants de genoll pretenen millorar la flexió màxima aconseguida amb els implants convencionals. El nostre estudi pretén demostrar que els pacients intervinguts quirúrgicament, per a la implantació d’una artroplàstia total de genoll d’alta flexió, són capaços d’aconseguir un balanç articular i una flexió màxima superior a l’aconseguida pels pacients tractats amb el model convencional. La flexió màxima post-operatòria, a l’any de la intervenció, va ser 13º major en el grup de pacients portadors d’un implant d’alta flexió, respecte al grup de pacients portadors d’un implant convencional. (P & 0,05).
Resumo:
Presentem un estudi prospectiu, a curt termini, de 10 pacients, per avaluar el resultat funcional i simptomàtic del tractament de la condropatia rotuliana mitjançant implants de polímers sintètics biodegradables. Es valora la clínica, qüestionaris (KOOS i SF-36) i RM, abans, als sis i dotze mesos de la cirurgia. Els resultats van ser satisfactoris en 8 dels 10 pacients. Per això pensem que el TruFitTM BGS Plug és una tècnica simple i eficaç per tractar les lesions del cartílag rotulià en pacients joves i amb lesions focals. Tanmateix, la seva eficàcia en comparació amb altres tractaments està encara per determinar.
Resumo:
L'alineació rotacional a l'astroplàstia total de genoll es refereix a la posició dels implants en el pla axial. Un mínim desplaçament afectarà la distribució de la càrrega y variarà l'estabilitat, l'alineació i la cinemàtica de l'articulació. Tot i que hi ha un consens pel que fa als efectes adversos d'una alineació rotacional incorrecta, encara no està clar quines són les referències anatòmiques que cal utilitzar. Les mesures de l'alineació rotacional requereixen un estudi d'alta qualitat. La TC és la modalitat d'imatge d'elecció per a l'estudi postoperatori de l'artroplàstia total de genoll. L'objectiu d'aquest treball es avaluar la capacitat diagnòstica de la TC per a l'estudi de l'alineació rotacional postoperatòria en l'artroplàstia total de genoll i presentar les variacions en el protocol de TC que minimitzen l'artefacte metàl•lic. Aquest estudi avalua la reproductibilitat de l'angle condili posterior, format per l'eix epicondili quirúrgic i la línia bicondilia posterior, mesurant la correlació entre dos observadors. El coeficient de correlació de Pearson mostra una forta correlació positiva (R=0.84) entre els dos observadors. La mitja d'error de les mesures adquirides és de -0.14º amb una desviació estàndar de 2.06º (-0.14 ± 2.06), per la qual cosa la modificació dels paràmetres tècnics de la TC per a la minimització dels artefactes metàl•lics és eficaç per l'avaluació rotacional. No obstant, l'alta magnitud de l'error indica que el radiòleg ha de ser prudent en el diagnòstic de mínimes variacions angulars que impliquin canvis en l'actitud mèdica i terapèutica.