13 resultados para HR diagram
em Consorci de Serveis Universitaris de Catalunya (CSUC), Spain
Resumo:
Johnson CCD photometry was performed in the two subgroups of the association Cepheus OB3, for selected fields each containing at least one star with previous UBV photoelectric photometry. Photometry for about 1000 stars down to visual magnitude 21 is provided, although the completeness tests show that the sample is complete down to V=19mag. Individual errors were assigned to the magnitude and colours for each star. Colour-colour and colour-magnitude diagrams are shown. Astrometric positions of the stars are also given. Description of the reduction procedure is fully detailed.
Resumo:
In recent years, several authors have revised the calibrations used to compute physical parameters (tex2html_wrap_inline498, tex2html_wrap_inline500, log g, [Fe/H]) from intrinsic colours in the tex2html_wrap_inline504 photometric system. For reddened stars, these intrinsic colours can be computed through the standard relations among colour indices for each of the regions defined by Strömgren (1966) on the HR diagram. We present a discussion of the coherence of these calibrations for main-sequence stars. Stars from open clusters are used to carry out this analysis. Assuming that individual reddening values and distances should be similar for all the members of a given open cluster, systematic differences among the calibrations used in each of the photometric regions might arise when comparing mean reddening values and distances for the members of each region. To classify the stars into Strömgren's regions we extended the algorithm presented by Figueras et al. (1991) to a wider range of spectral types and luminosity classes. The observational ZAMS are compared with the theoretical ZAMS from stellar evolutionary models, in the range tex2html_wrap_inline506 K. The discrepancies are also discussed.
Resumo:
"Vegeu el resum a l'inici del document del fitxer adjunt".
Resumo:
Through the history of Electrical Engineering education, vectorial and phasorial diagrams have been used as a fundamental learning tool. At present, computational power has replaced them by long data lists, the result of solving equation systems by means of numerical methods. In this sense, diagrams have been shifted to an academic background and although theoretically explained, they are not used in a practical way within specific examples. This fact may be against the understanding of the complex behavior of the electrical power systems by students. This article proposes a modification of the classical Perrine-Baum diagram construction to allowing both a more practical representation and a better understanding of the behavior of a high-voltage electric line under different levels of load. This modification allows, at the same time, the forecast of the obsolescence of this behavior and line’s loading capacity. Complementary, we evaluate the impact of this tool in the learning process showing comparative undergraduate results during three academic years
Resumo:
Destruction of historical urban fabric in many Chinese cities and towns, without the possibility of its recovery as an urban asset, leads us to consider alternative strategies and criteria for formulating new urban projects, using creative urban planning instruments and strategies to provide a sense of place and identity to the urban landscape. The challenge is to set up an urban structure that constitutes a spatial reference system, a structure consisting of a set of urban landmarks that construct a system of related public spaces, endowed with collective significance and identity. Such a network could include a wide variety of urban typologies and natural elements. An important result of this strategy would be the recovery of the social and cultural values attached to the natural landscape in Chinese civilization. Hangzhou city will be analyzed as a case study
Resumo:
X-ray diffraction analyses of the pure components n-tricosane and n-pentacosane and of their binary mixed samples have enabled us to characterize the crystalline phases observed at low temperature. On the contrary to what was announced in literature on the structural behavior of mixed samples in odd-odd binary systems with D n = 2, the three domains are not all orthorhombic. This work has enabled us to show that two of the domains are, in fact, monoclinic, (Aa, Z = 4) and the other one is orthorhombic (Pca21, Z = 4). The conclusions drawn in this work can be easily transposed to other binary systems of n-alkanes.
Resumo:
A general formulation of boundary conditions for semiconductor-metal contacts follows from a phenomenological procedure sketched here. The resulting boundary conditions, which incorporate only physically well-defined parameters, are used to study the classical unipolar drift-diffusion model for the Gunn effect. The analysis of its stationary solutions reveals the presence of bistability and hysteresis for a certain range of contact parameters. Several types of Gunn effect are predicted to occur in the model, when no stable stationary solution exists, depending on the value of the parameters of the injecting contact appearing in the boundary condition. In this way, the critical role played by contacts in the Gunn effect is clearly established.
Resumo:
We have used an axially symmetric deformed Thomas-Fermi model to evaluate the fission barrier of 240Pu as a function of the quadrupole moment Q2 for different values of the angular momentum L and temperature T. The fission stability diagram of this nucleus is investigated.
Resumo:
A general formulation of boundary conditions for semiconductor-metal contacts follows from a phenomenological procedure sketched here. The resulting boundary conditions, which incorporate only physically well-defined parameters, are used to study the classical unipolar drift-diffusion model for the Gunn effect. The analysis of its stationary solutions reveals the presence of bistability and hysteresis for a certain range of contact parameters. Several types of Gunn effect are predicted to occur in the model, when no stable stationary solution exists, depending on the value of the parameters of the injecting contact appearing in the boundary condition. In this way, the critical role played by contacts in the Gunn effect is clearly established.
Resumo:
The SeDeM Diagram Expert System has been used to study excipients, Captopril and designed formulations for their galenic characterization and to ascertain the critical points of the formula affecting product quality to obtain suitable formulations of Captopril Direct Compression SR Matrix Tablets. The application of the Sedem Diagram Expert System enables selecting excipients with in order to optimize the formula in the preformulation and formulation studies. The methodology is based on the implementation of ICH Q8, establishing the design space of the formula with the use of experiment design, using the parameters of the SeDeM Diagram Expert System as system responses.