52 resultados para EPC CAPTURING R STENT (TM)

em Consorci de Serveis Universitaris de Catalunya (CSUC), Spain


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To evaluate the agreement between multislice CT (MSCT) and intravascular ultrasound (IVUS) to assess the in-stent lumen diameters and lumen areas of left main coronary artery (LMCA) stents. Design: Prospective, observational single centre study. Setting: A single tertiary referral centre. Patients: Consecutive patients with LMCA stenting excluding patients with atrial fibrillation and chronic renal failure. Interventions: MSCT and IVUS imaging at 912 months follow-up were performed for all patients. Main outcome measures: Agreement between MSCT and IVUS minimum luminal area (MLA) and minimum luminal diameter (MLD). A receiver operating characteristic (ROC) curve was plotted to find the MSCT cut-off point to diagnose binary restenosis equivalent to 6 mm2 by IVUS. Results: 52 patients were analysed. PassingBablok regression analysis obtained a β coefficient of 0.786 (0.586 to 1.071) for MLA and 1.250 (0.936 to 1.667) for MLD, ruling out proportional bias. The α coefficient was −3.588 (−8.686 to −0.178) for MLA and −1.713 (−3.583 to −0.257) for MLD, indicating an underestimation trend of MSCT. The ROC curve identified an MLA ≤4.7 mm2 as the best threshold to assess in-stent restenosis by MSCT. Conclusions: Agreement between MSCT and IVUS to assess in-stent MLA and MLD for LMCA stenting is good. An MLA of 4.7 mm2 by MSCT is the best threshold to assess binary restenosis. MSCT imaging can be considered in selected patients to assess LMCA in-stent restenosis

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To evaluate the agreement between multislice CT (MSCT) and intravascular ultrasound (IVUS) to assess the in-stent lumen diameters and lumen areas of left main coronary artery (LMCA) stents. Design: Prospective, observational single centre study. Setting: A single tertiary referral centre. Patients: Consecutive patients with LMCA stenting excluding patients with atrial fibrillation and chronic renal failure. Interventions: MSCT and IVUS imaging at 9-12 months follow-up were performed for all patients. Main outcome measures: Agreement between MSCT and IVUS minimum luminal area (MLA) and minimum luminal diameter (MLD). A receiver operating characteristic (ROC) curve was plotted to find the MSCT cut-off point to diagnose binary restenosis equivalent to 6 mm2 by IVUS. Results: 52 patients were analysed. Passing-Bablok regression analysis obtained a β coefficient of 0.786 (0.586 to 1.071) for MLA and 1.250 (0.936 to 1.667) for MLD, ruling out proportional bias. The α coefficient was −3.588 (−8.686 to −0.178) for MLA and −1.713 (−3.583 to −0.257) for MLD, indicating an underestimation trend of MSCT. The ROC curve identified an MLA ≤4.7 mm2 as the best threshold to assess in-stent restenosis by MSCT. Conclusions: Agreement between MSCT and IVUS to assess in-stent MLA and MLD for LMCA stenting is good. An MLA of 4.7 mm2 by MSCT is the best threshold to assess binary restenosis. MSCT imaging can be considered in selected patients to assess LMCA in-stent restenosis

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To examine the safety and effectiveness of cobalt-chromium everolimus eluting stents compared with bare metal stents. Design: Individual patient data meta-analysis of randomised controlled trials. Cox proportional regression models stratified by trial, containing random effects, were used to assess the impact of stent type on outcomes. Hazard ratios with 95% confidence interval for outcomes were reported. Data sources and study selection: Medline, Embase, the Cochrane Central Register of Controlled Trials. Randomised controlled trials that compared cobalt-chromium everolimus eluting stents with bare metal stents were selected. The principal investigators whose trials met the inclusion criteria provided data for individual patients. Primary outcomes: The primary outcome was cardiac mortality. Secondary endpoints were myocardial infarction, definite stent thrombosis, definite or probable stent thrombosis, target vessel revascularisation, and all cause death. Results: The search yielded five randomised controlled trials, comprising 4896 participants. Compared with patients receiving bare metal stents, participants receiving cobalt-chromium everolimus eluting stents had a significant reduction of cardiac mortality (hazard ratio 0.67, 95% confidence interval 0.49 to 0.91; P=0.01), myocardial infarction (0.71, 0.55 to 0.92; P=0.01), definite stent thrombosis (0.41, 0.22 to 0.76; P=0.005), definite or probable stent thrombosis (0.48, 0.31 to 0.73; P<0.001), and target vessel revascularisation (0.29, 0.20 to 0.41; P<0.001) at a median follow-up of 720 days. There was no significant difference in all cause death between groups (0.83, 0.65 to 1.06; P=0.14). Findings remained unchanged at multivariable regression after adjustment for the acuity of clinical syndrome (for instance, acute coronary syndrome v stable coronary artery disease), diabetes mellitus, female sex, use of glycoprotein IIb/IIIa inhibitors, and up to one year v longer duration treatment with dual antiplatelets. Conclusions: This meta-analysis offers evidence that compared with bare metal stents the use of cobalt-chromium everolimus eluting stents improves global cardiovascular outcomes including cardiac survival, myocardial infarction, and overall stent thrombosis.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objectives: To examine the safety and effectiveness of cobalt-chromium everolimus eluting stents compared with bare metal stents. Design: Individual patient data meta-analysis of randomised controlled trials. Cox proportional regression models stratified by trial, containing random effects, were used to assess the impact of stent type on outcomes. Hazard ratios with 95% confidence interval for outcomes were reported. Data sources and study selection: Medline, Embase, the Cochrane Central Register of Controlled Trials. Randomised controlled trials that compared cobalt-chromium everolimus eluting stents with bare metal stents were selected. The principal investigators whose trials met the inclusion criteria provided data for individual patients. Primary outcomes: The primary outcome was cardiac mortality. Secondary endpoints were myocardial infarction, definite stent thrombosis, definite or probable stent thrombosis, target vessel revascularisation, and all cause death. Results: The search yielded five randomised controlled trials, comprising 4896 participants. Compared with patients receiving bare metal stents, participants receiving cobalt-chromium everolimus eluting stents had a significant reduction of cardiac mortality (hazard ratio 0.67, 95% confidence interval 0.49 to 0.91; P=0.01), myocardial infarction (0.71, 0.55 to 0.92; P=0.01), definite stent thrombosis (0.41, 0.22 to 0.76; P=0.005), definite or probable stent thrombosis (0.48, 0.31 to 0.73; P<0.001), and target vessel revascularisation (0.29, 0.20 to 0.41; P<0.001) at a median follow-up of 720 days. There was no significant difference in all cause death between groups (0.83, 0.65 to 1.06; P=0.14). Findings remained unchanged at multivariable regression after adjustment for the acuity of clinical syndrome (for instance, acute coronary syndrome v stable coronary artery disease), diabetes mellitus, female sex, use of glycoprotein IIb/IIIa inhibitors, and up to one year v longer duration treatment with dual antiplatelets. Conclusions: This meta-analysis offers evidence that compared with bare metal stents the use of cobalt-chromium everolimus eluting stents improves global cardiovascular outcomes including cardiac survival, myocardial infarction, and overall stent thrombosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we carefully link knowledge flows to and from a firms innovation process with this firms investment decisions. Three types of investments are considered: investments in applied research, investments in basic research, and investments in intellectual property protection. Only when basic research is performed, can the firm effectively access incoming knowledge flows and these incoming spillovers serve to increase the efficiency of own applied research.. The firm can at the same time influence outgoing knowledge flows, improving appropriability of its innovations, by investing in protection. Our results indicate that firms with small budgets for innovation will not invest in basic research. This occurs in the short run, when the budget for know-how creation is restricted, or in the long-run, when market opportunities are low, when legal protection is not very important, or, when the pool of accessible and relevant external know-how is limited. The ratio! of basic to applied research is non-decreasing in the size of the pool of accessible external know-how, the size and opportunity of the market, and, the effectiveness of intellectual property rights protection. This indicates the existence of economies of scale in basic research due to external market related factors. Empirical evidence from a sample of innovative manufacturing firms in Belgium confirms the economies of scale in basic research as a consequence of the firms capacity to access external knowledge flows and to protect intellectual property, as well as the complementarity between legal and strategic investments.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There is a relation between the generalized Property R Conjecture and the Schoenflies Conjecture that suggests a new line of attack on the latter. The new approach gives a quick proof of the genus 2 Schoenflies Conjecture and suffices to prove the genus 3 case, even in the absence of new progress on the generalized Property R Conjecture.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents empirical evidence on firms’ decisions to cooperate in R&D and the extent to which government sponsored R&D programs increase cooperation. Using a sample of firms from the Spanish innovation survey we jointly estimate the determinants of firm participation in R&D programs and of choice of cooperation partners. We find that (i) firms participating in national and European programs have different profiles, suggesting program complementarity; (ii) private-private and publicprivate cooperation are associated on average with firms with different characteristics, and (iii) national R&D programs seem to have a positive effect on all types of cooperation, but especially on public-private partnerships.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Empirical evidence on the effectiveness of R&D subsidies to firms has produced mixed results so far. One possible explanation is that firms and project selection rules may be quite heterogeneous both across agencies and across industries, leading to different outcomes in terms of the induced additional private effort. Here we focus on the participation stage. Using a sample of Spanish firms, we test for differences across agencies and industries. Our results suggest that firms in the same industry face different hurdles to participate in different agencies’ programs, that participation patterns may reflect a combination of agency goals, and that patterns differ across high-tech and low-tech industries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The implementation of public programs to support business R&D projects requires the establishment of a selection process. This selection process faces various difficulties, which include the measurement of the impact of the R&D projects as well as selection process optimization among projects with multiple, and sometimes incomparable, performance indicators. To this end, public agencies generally use the peer review method, which, while presenting some advantages, also demonstrates significant drawbacks. Private firms, on the other hand, tend toward more quantitative methods, such as Data Envelopment Analysis (DEA), in their pursuit of R&D investment optimization. In this paper, the performance of a public agency peer review method of project selection is compared with an alternative DEA method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper analyses the performance of companies’ R&D and innovation and the effects of intra- and inter-industry R&D spillover on firms’ productivity in Catalonia. The paper deals simultaneously with the performance of manufacturing and service firms, with the aim of highlighting the growing role of knowledge-intensive services in promoting innovation and productivity gains. We find that intra-industry R&D spillovers have an important effect on the productivity level of manufacturing firms, and the inter-industrial R&D spillovers related to computer and software services also play an important role, especially in high-tech manufacturing industries. The main conclusion is that the traditional classification of manufactured goods and services no longer makes sense in the ‘knowledge economy’ and in Catalonia the regional policy makers will have to design policies that favour inter-industrial R&D flows, especially from high-tech services.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

R&D investment is an important driver of productivity gains. However, firms differ in their ability to appropiate the returns to their R&D efforts. This paper analyses to what extent firm's internationalization influences the endogenous relation between R&D and productivity. In particular, we assess the contribution of R&D to productivity for a panel of UK firms that differ in their degree of internationalization. We find that, on average, multinationals obtain higher gains from their investment in R&D. However, the influence of internationalization on the contribution of R&D to productivity varies along the distribution of the returns to R&D. Keywords: R&D, Multinationals, Productivity. JEL Codes: C14, D24, F23.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

"Vegeu el resum a l'inici del document del fitxer adjunt"