50 resultados para Dental Impression Technique
em Consorci de Serveis Universitaris de Catalunya (CSUC), Spain
Resumo:
A beautiful smile is directly related with white teeth. Nowadays oral care has increased and developed processes for beautiful smiles. Dental bleaching is frequently used in odontology, not just for health care also for aesthetic treatment. With the possibility of teeth bleaching, now the importance is in, how white the tooth is? Because color is relate to an individual perception. In order to assets teeth correct color identification has been developed many color guides, models, spaces and analytical methods. Spite all of these useful tools the color interpretation depends on environmental factors, position of the sample in the data acquisition and most importantly the instrument sensitivity. The commons methods have proved to be useful. They are easy to handle, some are portable but they do not have a high sensitivity. The present work is based on the integration of a new analytical technique for color acquisition. High spectral Image (HSI) is able to performed image analysis with high quality and efficiency. HSI is used in many fields and we used it for color image analysis within the bleaching process. The main comparison was done with the HSI and the colorimeter through the processes of two different bleaching protocols. The results showed that HSI has higher sensitivity than the colorimeter. During the analysis the dental surface with the HSI we were able to notice surface changes. These changes were analyzed by roughness studies.
Resumo:
Objectives: This study evaluates the periodontal health status and the esthetic results of teeth subjected to orthodontic traction, after their exposure by an apically positioned flap. Study design: Fifteen patients were included in the study, ages between 11 and 28 years old. The fenestrated teeth and their homologous contralateral normally erupted teeth, used as control, were evaluated. Results: Statistically significant differences were found in the position of the gingival margin (p = 0.005), with an average distance between cemento-enamel junction (CEJ) and gingival margin of 2.47 mm (SD 1.19) in control teeth and of 1 mm (SD 1.31) in the operated teeth, and in the depth of palatal probing (p = 0.031), with 2.1 mm (SD 0.9) for the experimental teeth and 1.7 mm (SD 0.8) for the control teeth. The gingival index, the bleeding during probing and the probing depth did not show statistically significant differences. The patient"s subjective esthetic evaluation was more favorable for the control teeth in most of the cases. Conclusions: The surgical approach for the impacted teeth by means of the apically positioned flap resulted to be a predictable technique allowing the maintenance of the periodontal health on a long-term basis.
Resumo:
Los dientes son una importante fuente de información en el estudio de poblaciones del pasado. El estudio de las enfermedades dentales en restos esqueléticos antiguos busca reconstruir la forma de vida de las poblaciones antiguas relacionadas con su estado de salud y enfermedad.
Resumo:
Graph pebbling is a network model for studying whether or not a given supply of discrete pebbles can satisfy a given demand via pebbling moves. A pebbling move across an edge of a graph takes two pebbles from one endpoint and places one pebble at the other endpoint; the other pebble is lost in transit as a toll. It has been shown that deciding whether a supply can meet a demand on a graph is NP-complete. The pebbling number of a graph is the smallest t such that every supply of t pebbles can satisfy every demand of one pebble. Deciding if the pebbling number is at most k is NP 2 -complete. In this paper we develop a tool, called theWeight Function Lemma, for computing upper bounds and sometimes exact values for pebbling numbers with the assistance of linear optimization. With this tool we are able to calculate the pebbling numbers of much larger graphs than in previous algorithms, and much more quickly as well. We also obtain results for many families of graphs, in many cases by hand, with much simpler and remarkably shorter proofs than given in previously existing arguments (certificates typically of size at most the number of vertices times the maximum degree), especially for highly symmetric graphs. Here we apply theWeight Function Lemma to several specific graphs, including the Petersen, Lemke, 4th weak Bruhat, Lemke squared, and two random graphs, as well as to a number of infinite families of graphs, such as trees, cycles, graph powers of cycles, cubes, and some generalized Petersen and Coxeter graphs. This partly answers a question of Pachter, et al., by computing the pebbling exponent of cycles to within an asymptotically small range. It is conceivable that this method yields an approximation algorithm for graph pebbling.
Resumo:
This paper presents the implementation details of a coded structured light system for rapid shape acquisition of unknown surfaces. Such techniques are based on the projection of patterns onto a measuring surface and grabbing images of every projection with a camera. Analyzing the pattern deformations that appear in the images, 3D information of the surface can be calculated. The implemented technique projects a unique pattern so that it can be used to measure moving surfaces. The structure of the pattern is a grid where the color of the slits are selected using a De Bruijn sequence. Moreover, since both axis of the pattern are coded, the cross points of the grid have two codewords (which permits to reconstruct them very precisely), while pixels belonging to horizontal and vertical slits have also a codeword. Different sets of colors are used for horizontal and vertical slits, so the resulting pattern is invariant to rotation. Therefore, the alignment constraint between camera and projector considered by a lot of authors is not necessary
Resumo:
In the present work, microstructure improvement using FSP (Friction Stir Processing) is studied. In the first part of the work, the microstructure improvement of as-cast A356 is demonstrated. Some tensile tests were applied to check the increase in ductility. However, the expected results couldn’t be achieved. In the second part, the microstructure improvement of a fusion weld in 1050 aluminium alloy is presented. Hardness tests were carried out to prove the mechanical propertyimprovements. In the third and last part, the microstructure improvement of 1050 aluminium alloy is achieved. A discussion of the mechanical property improvements induced by FSP is made. The influence of tool traverse speed on microstructure and mechanical properties is also discussed. Hardness tests and recrystallization theory enabled us to find out such influence
Resumo:
Weather radar observations are currently the most reliable method for remote sensing of precipitation. However, a number of factors affect the quality of radar observations and may limit seriously automated quantitative applications of radar precipitation estimates such as those required in Numerical Weather Prediction (NWP) data assimilation or in hydrological models. In this paper, a technique to correct two different problems typically present in radar data is presented and evaluated. The aspects dealt with are non-precipitating echoes - caused either by permanent ground clutter or by anomalous propagation of the radar beam (anaprop echoes) - and also topographical beam blockage. The correction technique is based in the computation of realistic beam propagation trajectories based upon recent radiosonde observations instead of assuming standard radio propagation conditions. The correction consists of three different steps: 1) calculation of a Dynamic Elevation Map which provides the minimum clutter-free antenna elevation for each pixel within the radar coverage; 2) correction for residual anaprop, checking the vertical reflectivity gradients within the radar volume; and 3) topographical beam blockage estimation and correction using a geometric optics approach. The technique is evaluated with four case studies in the region of the Po Valley (N Italy) using a C-band Doppler radar and a network of raingauges providing hourly precipitation measurements. The case studies cover different seasons, different radio propagation conditions and also stratiform and convective precipitation type events. After applying the proposed correction, a comparison of the radar precipitation estimates with raingauges indicates a general reduction in both the root mean squared error and the fractional error variance indicating the efficiency and robustness of the procedure. Moreover, the technique presented is not computationally expensive so it seems well suited to be implemented in an operational environment.
Resumo:
The scaling up of the Hot Wire Chemical Vapor Deposition (HW-CVD) technique to large deposition area can be done using a catalytic net of equal spaced parallel filaments. The large area deposition limit is defined as the limit whenever a further increment of the catalytic net area does not affect the properties of the deposited film. This is the case when a dense catalytic net is spread on a surface considerably larger than that of the film substrate. To study this limit, a system able to hold a net of twelve wires covering a surface of about 20 cm x 20 cm was used to deposit amorphous (a-Si:H) and microcrystalline (μc-Si:H) silicon over a substrate of 10 cm x 10 cm placed at a filament-substrate distance ranging from 1 to 2 cm. The uniformity of the film thickness d and optical constants, n(x, λ) and α(x,¯hω), was studied via transmission measurements. The thin film uniformity as a function of the filament-substrate distance was studied. The experimental thickness profile was compared with the theoretical result obtained solving the diffusion equations. The optimization of the filament-substrate distance allowed obtaining films with inhomogeneities lower than ±2.5% and deposition rates higher than 1 nm/s and 4.5 nm/s for (μc-Si:H) and (a-Si:H), respectively.
Resumo:
The objective of this study was to assess the applicability of posterior wall repair with a synthetic absorbable mesh. Between January and September 1996, five posterior repairs using absorbable synthetic meshes were performed. Five posterior wall repairs in patients matched for age, parity, and rectocele degree were performed according to usual procedures during the same period, and were used as controls. No febrile morbidity, cuff or posterior vaginal wall infections, thrombophlebitis, rectal injury, or hemorrhagic complications were observed in the 10 women who entered the study. In summary, posterior wall repair can be easily performed with an absorbable soft tissue patch, theoretically preserving sexual activity, and probably offers better functional results with longer experience, thus providing a safe and useful procedure in sexually active women.
Resumo:
The purpose of the study was to evaluate the shear bond strength of stainless steel orthodontic brackets directly bonded to extracted human premolar teeth. Fifty teeth were randomly divided into ¿ve groups: (1) System One (chemically cured composite resin), (2) Light Bond (light-cured composite resin), (3) Vivaglass Cem (self-curing glass ionomer cement), (4) Fuji Ortho LC (light-cured glass ionomer cement) used after 37% orthophosphoric acid¿etching of enamel (5) Fuji Ortho LC without orthophosphoric acid¿etching. The brackets were placed on the buccal and lingual surfaces of each tooth, and the specimens were stored in distilled water (24 hours) at 378C and thermocycled. Teeth were mounted on acrylic block frames, and brackets were debonded using an Instron machine. Shear bond strength values at fracture (Nw)were recorded. ANOVA and Student-Newman-Keuls multiple comparison tests were performed (P , .05). Bonding failure site was recorded by stereomicroscope and analyzed by Chi-square test, selected specimens of each group were observed by scanning electron microscope. System One attained the highest bond strength. Light Bond and Fuji Ortho LC, when using an acid-etching technique, obtained bond strengths that were within the range of estimated bond strength values for successful clinical bonding. Fuji Ortho LC and Vivaglass Cem left an almost clean enamel surface after debracketing.
Resumo:
Nuestro trabajo pretende dar unas ideas básicas para el manejo de pacientes sometidos a tratamiento anticoagulante dando a conocer las posibles pautas a seguir respecto a su medicación: mantener intacta la terapia anticoagulante, modificar la terapia anticoagulante o realizar tratamiento combinado de heparina con anticoagulantes orales. La decisión deberá tomarse conjuntamente con el hematólogo responsable del paciente valorando cada caso según la morbilidad intrínseca de la intervención, el riesgo de tromboembolismo en función de la patología de base que presente el paciente y el grado de coagulación determinado mediante estudios de laboratorio (tiempo de protrombina e índice de trombotest).
Resumo:
Las obturaciones dentales de amalgama constituyen la fuente principal de exposición permanente de bajo nivel al vapor de mercurio (Hg°) y al mercurio inorgánico (Hg(II)) para la población general. La dosis de mercurio absorbido procedente de la amalgama es de 2.7 ¿g/día/persona para una cantidad promedio de 7.4 obturaciones. Si esta cantidad consistiera enteramente en mercurio inorgánico (Hg(II)), estaría muy por debajo de la cifra de 15 ¿g/día para una persona de 65 kg que la OMS considera como ingesta tolerable de mercurio inorgánico. En el caso de una exposición permanente a la misma cantidad, pero de vapor de mercurio (Hg0), se obtendría una concentración de 0.18 mg/m3 que puede compararse con la concentración de referencia de la EPA de 0.3 mg/m3 o con el nivel de riesgo mínimo de la ATSDR de 0.2 mg/m3. Varios estudios clínicos longitudinales y aleatorizados han evaluado la relación entre la concentración urinaria de mercurio y la exposición al mercurio procedente de las obturaciones dentales de amalgama en niños, particularmente vulnerables al Hg0, así como los posibles efectos neurológicos de tal exposición. La concentración promedio de mercurio en orina en los niños tratados con amalgama, con un promedio de 18,7 superficies obturadas, aumentó hasta un pico de 3.2 ¿g/L a los 2 años de iniciado el tratamiento y a los 7 años de seguimiento había descendido hasta los niveles basales y no se detectó ninguna alteración en las distintas exploraciones de monitorización neuropsicológica. De la misma manera, diversas investigaciones epidemiológicas no han aportado ninguna evidencia del papel de la amalgama en la posible causa o exacerbación de trastornos degenerativos como la esclerosis lateral amiotrófica, la enfermedad de Alzheimer, la esclerosis múltiple o el Parkinson. La extracción de las obturaciones de amalgama produce un aumento transitorio de los niveles de mercurio en sangre inmediatamente después de extraer las obturaciones de amalgama, pero de pequeña magnitud y que se normaliza a los 100 días, por lo que el efecto del dique de goma tiene una relevancia toxicológica menor. La conclusión de esta revisión es que la amalgama dental continúa siendo un excelente material de obturación.
Resumo:
Se presenta en este artículo una revisión del riesgo de transmisión de enfermedades infecciosas en la clínica dental. Las hepatitis víricas, en especial la hepatitis B y la C, la infección por el virus de la inmunodeficiencia humana, la tuberculosis, y otras enfermedades infecciosas pueden ser potencialmente transmitidas en el ejercicio de la profesión, tanto a los pacientes como a los profesionales. El conocimiento de la probabilidad de transmisión y sus características son la base sobre la que desarrollarán las medidas preventivas de control de infección que intentan evitar o por lo menos minimizar la probabilidad de adquirir estas enfermedades en el ámbito laboral.
Resumo:
We report magnetic and magneto-optical measurements of two Mn12 single-molecule magnet derivatives isolated in organic glasses. Field-dependent magnetic circular dichroism (MCD) intensity curves (hysteresis cycles) are found to be essentially identical to superconducting quantum interference device magnetization results and provide experimental evidence for the potential of the optical technique for magnetic characterization. Optical observation of magnetic tunneling has been achieved by studying the decay of the MCD signal at weak applied magnetic field