5 resultados para DETECTION CELL

em Consorci de Serveis Universitaris de Catalunya (CSUC), Spain


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Avalanche photodiodes operated in the Geiger mode offer a high intrinsic gain as well as an excellent timing accuracy. These qualities make the sensor specially suitable for those applications where detectors with high sensitivity and low timing uncertainty are required. Moreover, they are compatible with standard CMOS technologies, allowing sensor and front-end electronics integration within the pixel cell. However, the sensor suffers from high levels of intrinsic noise, which may lead to erroneous results and limit the range of detectable signals. They also increase the amount of data that has to be stored. In this work, we present a pixel based on a Geiger-mode avalanche photodiode operated in the gated mode to reduce the probability to detect noise counts interfering with photon arrival events. The readout circuit is based on a two grounds scheme to enable low reverse bias overvoltages and consequently lessen the dark count rate. Experimental characterization of the fabricated pixel with the HV-AMS 0.35µm standard technology is also presented in this article.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: The candidate malaria vaccine RTS,S/AS02A is a recombinant protein containing part of the circumsporozoite protein (CSP) sequence of Plasmodium falciparum, linked to the hepatitis B surface antigen and formulated in the proprietary adjuvant system AS02A. In a recent trial conducted in children younger than age five in southern Mozambique, the vaccinedemonstrated significant and sustained efficacy against both infection and clinical disease. In a follow-up study to the main trial, breakthrough infections identified in the trial were examined to determine whether the distribution of csp sequences was affected by the vaccine and to measure the multiplicity of infecting parasite genotypes. Design: P. falciparum DNA from isolates collected during the trial was used for genotype studies. Setting: The main trial was carried out in the Manhiça district, Maputo province, Mozambique, between April 2003 and May 2004. Participants: Children from the two cohorts of the main trial provided parasite isolates as follows: children from Cohort 1 who were admitted to hospital with clinical malaria; children from Cohort 1 who were parasite-positive in a cross-sectional survey at study month 8.5; children from Cohort 2 identified as parasite-positive during follow-up by active detection of infection. Outcome: Divergence of DNA sequence encoding the CSP T cell-epitope region sequence from that of the vaccine sequence was measured in 521 isolates. The number of distinct P. falciparum genotypes was also determined. Results: We found no evidence that parasite genotypes from children in the RTS,S/AS02A arm were more divergent than those receiving control vaccines. For Cohort 1 (survey at studymonth 8.5) and Cohort 2, infections in the vaccine group contained significantly fewer genotypes than those in the control group, (p 1/4 0.035, p 1/4 0.006), respectively, for the two cohorts. This was not the case for children in Cohort 1 who were admitted to hospital (p 1/4 0.478). Conclusions: RTS,S/AS02A did not select for genotypes encoding divergent T cell epitopes in the C-terminal region of CSP in this trial. In both cohorts, there was a modest reduction in the mean number of parasite genotypes harboured by vaccinated children compared with controls, but only among those with asymptomatic infections.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this review we highlight recent work that has increased our understanding of the distribution of Shiga toxin-converting phages that can be detected as free phage particles, independently of Shiga toxin-producing bacteria (STEC). Stx phages are a quite diverse group of temperate phages that can be found in their prophage state inserted within the STEC chromosome, but can also be found as phages released from the cell after activation of their lytic cycle. They have been detected in extraintestinal environments such as water polluted with feces from humans or animals, food samples or even in stool samples of healthy individuals. The high persistence of phages to several inactivation conditions makes them suitable candidates for the successful mobilization of stx genes, possibly resulting in the genes reaching a new bacterial genomic background by means of transduction, where ultimately they may be expressed, leading to Stx production. Besides the obvious fact that Stx phages circulating between bacteria can be, and probably are, involved in the emergence of new STEC strains, we review here other possible ways in which free Stx phages could interfere with the detection of STEC in a given sample by current laboratory methods and how to avoid such interference.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recently, three new polyomaviruses (KI, WU and Merkel cell polyomavirus) have been reported to infect humans. It has also been suggested that lymphotropic polyomavirus, a virus of simian origin, infects humans. KI and WU polyomaviruses have been detected mainly in specimens from the respiratory tract while Merkel cell polyomavirus has been described in a very high percentage of Merkel cell carcinomas. The distribution, excretion level and transmission routes of these viruses remain unknown. Here we analyzed the presence and characteristics of newly described human polyomaviruses in urban sewage and river water in order to assess the excretion level and the potential role of water as a route of transmission of these viruses. Nested-PCR assays were designed for the sensitive detection of the viruses studied and the amplicons obtained were confirmed by sequencing analysis. The viruses were concentrated following a methodology previously developed for the detection of JC and BK human polyomaviruses in environmental samples. JC polyomavirus and human adenoviruses were used as markers of human contamination in the samples. Merkel cell polyomavirus was detected in 7/8 urban sewage samples collected and in 2/7 river water samples. Also one urine sample from a pregnant woman, out of 4 samples analyzed, was positive for this virus. KI and WU polyomaviruses were identified in 1/8 and 2/8 sewage samples respectively. The viral strains detected were highly homologous with other strains reported from several other geographical areas. Lymphotropic polyomavirus was not detected in any of the 13 sewage neither in 9 biosolid/sludge samples analyzed. This is the first description of a virus isolated from sewage and river water with a strong association with cancer. Our data indicate that the Merkel cell polyomavirus is prevalent in the population and that it may be disseminated through the fecal/urine contamination of water. The procedure developed may constitute a useful tool for studying the excreted strains, prevalence and transmission of these recently described polyomaviruses.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The mechanical properties of biological cells have long been considered as inherent markers of biological function and disease. However, the screening and active sorting of heterogeneous populations based on serial single-cell mechanical measurements has not been demonstrated. Here we present a novel monolithic glass chip for combined fluorescence detection and mechanical phenotyping using an optical stretcher. A new design and manufacturing process, involving the bonding of two asymmetrically etched glass plates, combines exact optical fiber alignment, low laser damage threshold and high imaging quality with the possibility of several microfluidic inlet and outlet channels. We show the utility of such a custombuilt optical stretcher glass chip by measuring and sorting single cells in a heterogeneous population based on their different mechanical properties and verify sorting accuracy by simultaneous fluorescence detection. This offers new possibilities of exact characterization and sorting of small populations based on rheological properties for biological and biomedical applications.