64 resultados para Cubic stiffness
em Consorci de Serveis Universitaris de Catalunya (CSUC), Spain
Resumo:
The presence of subcentres cannot be captured by an exponential function. Cubic spline functions seem more appropriate to depict the polycentricity pattern of modern urban systems. Using data from Barcelona Metropolitan Region, two possible population subcentre delimitation procedures are discussed. One, taking an estimated derivative equal to zero, the other, a density gradient equal to zero. It is argued that, in using a cubic spline function, a delimitation strategy based on derivatives is more appropriate than one based on gradients because the estimated density can be negative in sections with very low densities and few observations, leading to sudden changes in estimated gradients. It is also argued that using as a criteria for subcentre delimitation a second derivative with value zero allow us to capture a more restricted subcentre area than using as a criteria a first derivative zero. This methodology can also be used for intermediate ring delimitation.
Resumo:
"Vegeu el resum a l'inici del document del fitxer adjunt."
Resumo:
The occurrence of heterostructures of cubic silicon/hexagonal silicon as disks defined along the nanowire (111) growth direction is reviewed in detail for Si nanowires obtained using Cu as catalyst. Detailed measurements on the structural properties of both semiconductor phases and their interface are presented. We observe that during growth, lamellar twinning on the cubic phase along the (111) direction is generated. Consecutive presence of twins along the (111) growth direction was found to be correlated with the origin of the local formation of the hexagonal Si segments along the nanowires, which define quantum wells of hexagonal Si diamond. Finally, we evaluate and comment on the consequences of the twins and wurtzite in the final electronic properties of the wires with the help of the predicted energy band diagram.
Resumo:
To quantify the vibrational anharmonicity of the long-wavelength acoustic modes of bcc Cu74.1Al23.1Be2.8 near its martensitic transition temperature Ms (261 K), the hydrostatic pressure derivatives (¿CIJ/¿P)P=0 of the elastic stiffness moduli have been measured. The Grüneisen parameters at 268 K (just above Ms), especially of longitudinal modes, which become smaller than those of the shear modes, are quite different from those at 295 K: the anharmonicity changes markedly in the vicinity of the transition. Similar trends are noted for Cu66.5Al12.7Zn20.8. Experimental data near Ms are used to estimate cubic invariants in the strain order parameters in a Landau formalism.
Resumo:
In a recent paper A. S. Johal and D. J. Dunstan [Phys. Rev. B 73, 024106 (2006)] have applied multivariate linear regression analysis to the published data of the change in ultrasonic velocity with applied stress. The aim is to obtain the best estimates for the third-order elastic constants in cubic materials. From such an analysis they conclude that uniaxial stress data on metals turns out to be nearly useless by itself. The purpose of this comment is to point out that by a proper analysis of uniaxial stress data it is possible to obtain reliable values of third-order elastic constants in cubic metals and alloys. Cu-based shape memory alloys are used as an illustrative example.
Resumo:
BACKGROUND AND AIMS: Liver stiffness is increasingly used in the non-invasive evaluation of chronic liver diseases. Liver stiffness correlates with hepatic venous pressure gradient (HVPG) in patients with cirrhosis and holds prognostic value in this population. Hence, accuracy in its measurement is needed. Several factors independent of fibrosis influence liver stiffness, but there is insufficient information on whether meal ingestion modifies liver stiffness in cirrhosis. We investigated the changes in liver stiffness occurring after the ingestion of a liquid standard test meal in this population. METHODS: In 19 patients with cirrhosis and esophageal varices (9 alcoholic, 9 HCV-related, 1 NASH; Child score 6.9±1.8), liver stiffness (transient elastography), portal blood flow (PBF) and hepatic artery blood flow (HABF) (Doppler-Ultrasound) were measured before and 30 minutes after receiving a standard mixed liquid meal. In 10 the HVPG changes were also measured. RESULTS: Post-prandial hyperemia was accompanied by a marked increase in liver stiffness (+27±33%; p<0.0001). Changes in liver stiffness did not correlate with PBF changes, but directly correlated with HABF changes (r = 0.658; p = 0.002). After the meal, those patients showing a decrease in HABF (n = 13) had a less marked increase of liver stiffness as compared to patients in whom HABF increased (n = 6; +12±21% vs. +62±29%,p<0.0001). As expected, post-prandial hyperemia was associated with an increase in HVPG (n = 10; +26±13%, p = 0.003), but changes in liver stiffness did not correlate with HVPG changes. CONCLUSIONS: Liver stiffness increases markedly after a liquid test meal in patients with cirrhosis, suggesting that its measurement should be performed in standardized fasting conditions. The hepatic artery buffer response appears an important factor modulating postprandial changes of liver stiffness. The post-prandial increase in HVPG cannot be predicted by changes in liver stiffness.
Resumo:
We perform Hartree calculations of symmetric and asymmetric semi-infinite nuclear matter in the framework of relativistic models based on effective hadronic field theories as recently proposed in the literature. In addition to the conventional cubic and quartic scalar self-interactions, the extended models incorporate a quartic vector self-interaction, scalar-vector non-linearities and tensor couplings of the vector mesons. We investigate the implications of these terms on nuclear surface properties such as the surface energy coefficient, surface thickness, surface stiffness coefficient, neutron skin thickness and the spin-orbit force.
Resumo:
ABSTRACT Dual-trap optical tweezers are often used in high-resolution measurements in single-molecule biophysics. Such measurements can be hindered by the presence of extraneous noise sources, the most prominent of which is the coupling of fluctuations along different spatial directions, which may affect any optical tweezers setup. In this article, we analyze, both from the theoretical and the experimental points of view, the most common source for these couplings in dual-trap optical-tweezers setups: the misalignment of traps and tether. We give criteria to distinguish different kinds of misalignment, to estimate their quantitative relevance and to include them in the data analysis. The experimental data is obtained in a, to our knowledge, novel dual-trap optical-tweezers setup that directly measures forces. In the case in which misalignment is negligible, we provide a method to measure the stiffness of traps and tether based on variance analysis. This method can be seen as a calibration technique valid beyond the linear trap region. Our analysis is then employed to measure the persistence length of dsDNA tethers of three different lengths spanning two orders of magnitude. The effective persistence length of such tethers is shown to decrease with the contour length, in accordance with previous studies.
Resumo:
This paper presents an experimental study of the effects of tow-drop gaps in Variable Stiffness Panels under drop-weight impact events. Two different configurations, with and without ply-staggering, have been manufactured by Automated Fibre Placement and compared with their baseline counterpart without defects. For the study of damage resistance, three levels of low velocity impact energy are generated with a drop-weight tower. The damage area is analysed by means of ultrasonic inspection. Results of the analysed defect configurations indicate that the influence of gap defects is only relevant under small impact energy values. However, in the case of damage tolerance, the residual compressive strength after impact does not present significant differences to that of conventional straight fibre laminates. This indicates that the strength reduction is driven mainly by the damage caused by the impact event rather than by the influence of manufacturing-induced defects
Resumo:
Automated Fiber Placement is being extensively used in the production of major composite components for the aircraft industry. This technology enables the production of tow-steered panels, which have been proven to greatly improve the structural efficiency of composites by means of in-plane stiffness variation and load redistribution. However, traditional straight-fiber architectures are still preferred. One of the reasons behind this is related to the uncertainties, as a result of process-induced defects, in the mechanical performance of the laminates. This experimental work investigates the effect of the fiber angle discontinuities between different tow courses in a ply on the un-notched and open-hole tensile strength of the laminate. The influence of several manufacturing parameters are studied in detail. The results reveal that 'ply staggering' and '0% gap coverage' is an effective combination in reducing the influence of defects in these laminates
Resumo:
BACKGROUND AND AIMS: Liver stiffness is increasingly used in the non-invasive evaluation of chronic liver diseases. Liver stiffness correlates with hepatic venous pressure gradient (HVPG) in patients with cirrhosis and holds prognostic value in this population. Hence, accuracy in its measurement is needed. Several factors independent of fibrosis influence liver stiffness, but there is insufficient information on whether meal ingestion modifies liver stiffness in cirrhosis. We investigated the changes in liver stiffness occurring after the ingestion of a liquid standard test meal in this population. METHODS: In 19 patients with cirrhosis and esophageal varices (9 alcoholic, 9 HCV-related, 1 NASH; Child score 6.9±1.8), liver stiffness (transient elastography), portal blood flow (PBF) and hepatic artery blood flow (HABF) (Doppler-Ultrasound) were measured before and 30 minutes after receiving a standard mixed liquid meal. In 10 the HVPG changes were also measured. RESULTS: Post-prandial hyperemia was accompanied by a marked increase in liver stiffness (+27±33%; p<0.0001). Changes in liver stiffness did not correlate with PBF changes, but directly correlated with HABF changes (r = 0.658; p = 0.002). After the meal, those patients showing a decrease in HABF (n = 13) had a less marked increase of liver stiffness as compared to patients in whom HABF increased (n = 6; +12±21% vs. +62±29%,p<0.0001). As expected, post-prandial hyperemia was associated with an increase in HVPG (n = 10; +26±13%, p = 0.003), but changes in liver stiffness did not correlate with HVPG changes. CONCLUSIONS: Liver stiffness increases markedly after a liquid test meal in patients with cirrhosis, suggesting that its measurement should be performed in standardized fasting conditions. The hepatic artery buffer response appears an important factor modulating postprandial changes of liver stiffness. The post-prandial increase in HVPG cannot be predicted by changes in liver stiffness.
Resumo:
La RMB es una ciudad de tipo policéntrico en la que resaltan unas ciudades de tamaño medio con elevada presencia de actividad económica y que, en muchos casos, destacan por sus dinámicas de crecimiento endógeno. El objetivo de esta investigación era hallar evidencia empírica en la RMB acerca de los determinantes de la localización de la actividad económica. Un objetivo que, a la par, requería la inclusión del estudio de la estructura urbana de la región para poder evaluar el efecto que en ella ejercen los determinantes de la localización. Si bien los resultados obtenidos con la Exponencial son buenos, la inclusión de formas funcionales de tipo polinómico para capturar los grumos de densidad han demostrado su eficiencia. Aunque la Cubic-Spline obtiene buenos resultados, tiene el inconveniente de no poder interpretar sus coeficientes. No obstante, nuestra propuesta, la Spline-Lineal, nos permite detectar la presencia de los subcentros que constituyen la región en base a la existencia de gradientes de densidad positivos.
Resumo:
The metropolitan spatial structure displays various patterns, sometimes monocentricity and sometimes multicentricity, which seems much more complicated than the exponential density function used in classic works such as Clark (1961), Muth (1969) or Mills (1973) among others, can effectively represent. It seems that a more flexible density function,such as cubic spline function (Anderson (1982), Zheng (1991), etc.) to describe the density-accessibility relationship is needed. Also, accessibility, the fundamental determinant of density variations, is only partly captured by the inclusion of distance to the city centre as an explanatory variable. Steen (1986) has proposed to correct that miss-especification by including an additional gradient for distance to the nearest transportation axis. In identifying the determinants of urban spatial structure in the context of inter-urban systems, some of the variables proposed by Muth (1969), Mills (1973) and Alperovich (1983) such as city age or population, make no sense in the case of a single urban system. All three criticism to the exponential density function and its determinants apply for the Barcelona Metropolitan Region, a polycentric conurbation structured on well defined transportation axes.
Resumo:
Projecte de recerca elaborat a partir d’una estada al Departament d’Enginyeria Química del Massachusetts Institute of Technology entre abril i octubre del 2006. S’ha dissenyat i sintetitzat uns nous films polimèrics, amb aplicacions en l’àmbit de l’enginyeria de teixits, utilitzant la tècnica anomenada iCVD (initiated Chemical Vapor Deposition), prèviament desenvolupada pel grup receptor. Es tracta d’uns hidrogels superficials de gruix controlable, que incorporen un monòmer fluorat, el qual s’havia estudiat extensament en el grup d’origen. Aquest monòmer es caracteritza per reaccionar molt fàcilment amb pèptids, de manera que aquests queden units covalentment a la superfície. Diferents estratègies pel desenvolupament d’aquests copolímers han estat avaluades, tant des del punt de vista purament sintètic com de la pròpia aplicació. Les condicions de polimerització han estat optimitzades i els hidrogels s’han caracteritzat químicament per tècniques espectroscòpiques (FTIR, XPS), i físicament per angle de contacte i el·lipsometria. D’aquesta manera, s’ha estudiat la capacitat dels hidrogels d’absorbir aigua i alhora augmentar el seu gruix, depenent de la quantitat d’agent reticulant introduït i de la incorporació del nou monòmer. A continuació, s’han optimitzat les condicions de reacció d’aquestes superfícies amb pèptids que incorporen una molècula fluorescent, la qual permet detectar fàcilment per microscòpia de fluorescència si la reacció ha tingut lloc. Una vegada la plataforma ha estat posada a punt, s’han iniciat assajos cel·lulars tant amb fibroblasts embriònics de ratolí com amb cèl·lules humanes umbilicals. Els resultats preliminars suggereixen una morfologia diferent de les cèl·lules segons si es cultiven sobre films modificats amb pèptids que promouen l’adhesió cel·lular o sobre les seves seqüències permutades no actives. Però, el més interessant és que també s’han observat certes diferències depenent si els films contenen el component hidrogel o no, fet que suggeriria un paper actiu d’aquests noves superfícies en el comportament cel·lular.
Application of standard and refined heat balance integral methods to one-dimensional Stefan problems
Resumo:
The work in this paper concerns the study of conventional and refined heat balance integral methods for a number of phase change problems. These include standard test problems, both with one and two phase changes, which have exact solutions to enable us to test the accuracy of the approximate solutions. We also consider situations where no analytical solution is available and compare these to numerical solutions. It is popular to use a quadratic profile as an approximation of the temperature, but we show that a cubic profile, seldom considered in the literature, is far more accurate in most circumstances. In addition, the refined integral method can give greater improvement still and we develop a variation on this method which turns out to be optimal in some cases. We assess which integral method is better for various problems, showing that it is largely dependent on the specified boundary conditions.