11 resultados para CT FINDINGS

em Consorci de Serveis Universitaris de Catalunya (CSUC), Spain


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Es va realitzar el II Workshop en Tomografia Computeritzada (TC) a Monells. El primer dia es va dedicar íntegrament a la utilització del TC en temes de classificació de canals porcines, i el segon dia es va obrir a altres aplicacions del TC, ja sigui en animals vius o en diferents aspectes de qualitat de la carn o els productes carnis. Al workshop hi van assistir 45 persones de 12 països de la UE. The II workshop on the use of Computed Tomography (CT) in pig carcass classification. Other CT applications: live animals and meat technology was held in Monells. The first day it was dedicated to the use of CT in pig carcass classification. The segond day it was open to otehr CT applications, in live animals or in meat and meat products quality. There were 45 assistants of 12 EU countries.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Es presenta un estudi retrospectiu descrivint les característiques radiològiques en una sèrie de nou casos de tumor fibrós solitari que affecta partes toves. Aquests resultats es comparen amb els resultats d’anatomia patològica i amb l’evolució clínica dels pacients

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introducció. Material y mètodes. El nostre objectiu és valorar la utilitat del PET/CT 11C-Colina a la recidiva bioquímica oculta del carcinoma de pròstata. Es van estudiar retrospectivament 58 pacients amb aument de PSA posttractament. La interpretació de les imatges fou visual. Resultats: El PET/CT fou positiu en 39 pacients (67%) (PSA mitjà: 11.7). Es van dividir els malats en 4 grups segons el valor del PSA (sensibilitat%): &1ng/ml:50% 1ng/ml -3ng/ml:60% 3ng/ml-5ng/ml:86% & a 5ng/ml:91% . Conclusió: La PET/CT 11C-Colina mostra una alta capacitat de detecció per valors de PSA superiors a 5ng/ml i pot ser útil en valors superiors a 1ng/ml.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Patient-specific simulations of the hemodynamics in intracranial aneurysms can be constructed by using image-based vascular models and CFD techniques. This work evaluates the impact of the choice of imaging technique on these simulations

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper, differences in return autocorrelation across weekdays havebeen investigated. Our research provides strong evidence of the importanceon non-trading periods, not only weekends and holidays but also overnightclosings, to explain return autocorrelation anomalies. While stock returnsare highly autocorrelated, specially on Mondays, when daily returns arecomputed on a open-to-close basis, they do not exhibit any significantlevel of autocorrelation. Our results are compatible with theinformation processing hypotheses as an explanation of the weekendeffect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A pure sensory neuropathy caused by lymphocytic infiltration of the dorsal root ganglia has been reported in a few patients with Sjögren's syndrome. The clinical, immunological, and electromyographic findings of five patients with this type of neuropathy and primary Sjögren's syndrome were reviewed. Typical clinical indications were the presence of a chronic asymmetrical sensory deficit, initial disease in the hands with a predominant loss of the vibratory and joint position senses, and an association with Adie's pupil syndrome or trigeminal sensory neuropathy. The simultaneous impairment of the central and peripheral evoked cortical potentials suggested that there was a lesion of the neuronal cell body. The neuropathy preceded the diagnosis of Sjögren's syndrome in four patients. Four patients were positive for Ro antibodies, but systemic vasculitis or malignancy was not found after a mean follow up of six years. These findings indicate that in patients with a sensory neuropathy the diagnosis of Sjögren's syndrome has to be considered, even if the patient denies the presence of sicca symptoms, and that appropriate tests must be carried out.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The optical-absorption spectrum of a cationic Ag0 atom in a KCl crystal has been studied theoretically by means of a series of cluster models of increasing size. Excitation energies have been determined by means of a multiconfigurational self-consistent field procedure followed by a second-order perturbation correlation treatment. Moreover results obtained within the density-functional framework are also reported. The calculations confirm the assignment of bands I and IV to transitions of the Ag-5s electron into delocalized states with mainly K-4s,4p character. Bands II and III have been assigned to internal transitions on the Ag atom, which correspond to the atomic Ag-4d to Ag-5s transition. We also determine the lowest charge transfer (CT) excitation energy and confirm the assignment of band VI to such a transition. The study of the variation of the CT excitation energy with the Ag-Cl distance R gives additional support to a large displacement of the Cl ions due to the presence of the Ag0 impurity. Moreover, from the present results, it is predicted that on passing to NaCl:Ag0 the CT onset would be out of the optical range while the 5s-5p transition would undergo a redshift of 0.3 eV. These conclusions, which underline the different character of involved orbitals, are consistent with experimental findings. The existence of a CT transition in the optical range for an atom inside an ionic host is explained by a simple model, which also accounts for the differences with the more common 3d systems. The present study sheds also some light on the R dependence of the s2-sp transitions due to s2 ions like Tl+.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the agreement between multislice CT (MSCT) and intravascular ultrasound (IVUS) to assess the in-stent lumen diameters and lumen areas of left main coronary artery (LMCA) stents. Design: Prospective, observational single centre study. Setting: A single tertiary referral centre. Patients: Consecutive patients with LMCA stenting excluding patients with atrial fibrillation and chronic renal failure. Interventions: MSCT and IVUS imaging at 912 months follow-up were performed for all patients. Main outcome measures: Agreement between MSCT and IVUS minimum luminal area (MLA) and minimum luminal diameter (MLD). A receiver operating characteristic (ROC) curve was plotted to find the MSCT cut-off point to diagnose binary restenosis equivalent to 6 mm2 by IVUS. Results: 52 patients were analysed. PassingBablok regression analysis obtained a β coefficient of 0.786 (0.586 to 1.071) for MLA and 1.250 (0.936 to 1.667) for MLD, ruling out proportional bias. The α coefficient was −3.588 (−8.686 to −0.178) for MLA and −1.713 (−3.583 to −0.257) for MLD, indicating an underestimation trend of MSCT. The ROC curve identified an MLA ≤4.7 mm2 as the best threshold to assess in-stent restenosis by MSCT. Conclusions: Agreement between MSCT and IVUS to assess in-stent MLA and MLD for LMCA stenting is good. An MLA of 4.7 mm2 by MSCT is the best threshold to assess binary restenosis. MSCT imaging can be considered in selected patients to assess LMCA in-stent restenosis

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe a female patient with a midline syndrome. The patient presents agenesis of the corpus callosum, encephalocele, iris coloboma, hypertelorism, submucosal cleft palate and dental anomalies. Despite being very characteristic, her phenotypical traits do not coincide exactly with those reported to date in the literature. The karyotype and the molecular cytogenetic study do not show mutations. We identify the presence of dental anomalies in the mother and other family members, not being identified MSX1 and PAX9 mutations that could the related with their etiology. Despite the fact that dental agenesis has been related to a large number of other malformation syndromes and congenital conditions, dental anomalies have only rarely been mentioned when reporting midline syndromes. These dental phenotypical traits, present in the patient and her family, could be considered part of the midline syndrome in carriers as well as in the patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To evaluate the agreement between multislice CT (MSCT) and intravascular ultrasound (IVUS) to assess the in-stent lumen diameters and lumen areas of left main coronary artery (LMCA) stents. Design: Prospective, observational single centre study. Setting: A single tertiary referral centre. Patients: Consecutive patients with LMCA stenting excluding patients with atrial fibrillation and chronic renal failure. Interventions: MSCT and IVUS imaging at 9-12 months follow-up were performed for all patients. Main outcome measures: Agreement between MSCT and IVUS minimum luminal area (MLA) and minimum luminal diameter (MLD). A receiver operating characteristic (ROC) curve was plotted to find the MSCT cut-off point to diagnose binary restenosis equivalent to 6 mm2 by IVUS. Results: 52 patients were analysed. Passing-Bablok regression analysis obtained a β coefficient of 0.786 (0.586 to 1.071) for MLA and 1.250 (0.936 to 1.667) for MLD, ruling out proportional bias. The α coefficient was −3.588 (−8.686 to −0.178) for MLA and −1.713 (−3.583 to −0.257) for MLD, indicating an underestimation trend of MSCT. The ROC curve identified an MLA ≤4.7 mm2 as the best threshold to assess in-stent restenosis by MSCT. Conclusions: Agreement between MSCT and IVUS to assess in-stent MLA and MLD for LMCA stenting is good. An MLA of 4.7 mm2 by MSCT is the best threshold to assess binary restenosis. MSCT imaging can be considered in selected patients to assess LMCA in-stent restenosis