31 resultados para Apparecchiature biomediche, Tomografia Computerizzata, Cone Beam CT, Odontoiatria

em Consorci de Serveis Universitaris de Catalunya (CSUC), Spain


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Es va realitzar el II Workshop en Tomografia Computeritzada (TC) a Monells. El primer dia es va dedicar íntegrament a la utilització del TC en temes de classificació de canals porcines, i el segon dia es va obrir a altres aplicacions del TC, ja sigui en animals vius o en diferents aspectes de qualitat de la carn o els productes carnis. Al workshop hi van assistir 45 persones de 12 països de la UE. The II workshop on the use of Computed Tomography (CT) in pig carcass classification. Other CT applications: live animals and meat technology was held in Monells. The first day it was dedicated to the use of CT in pig carcass classification. The segond day it was open to otehr CT applications, in live animals or in meat and meat products quality. There were 45 assistants of 12 EU countries.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To evaluate the agreement between multislice CT (MSCT) and intravascular ultrasound (IVUS) to assess the in-stent lumen diameters and lumen areas of left main coronary artery (LMCA) stents. Design: Prospective, observational single centre study. Setting: A single tertiary referral centre. Patients: Consecutive patients with LMCA stenting excluding patients with atrial fibrillation and chronic renal failure. Interventions: MSCT and IVUS imaging at 912 months follow-up were performed for all patients. Main outcome measures: Agreement between MSCT and IVUS minimum luminal area (MLA) and minimum luminal diameter (MLD). A receiver operating characteristic (ROC) curve was plotted to find the MSCT cut-off point to diagnose binary restenosis equivalent to 6 mm2 by IVUS. Results: 52 patients were analysed. PassingBablok regression analysis obtained a β coefficient of 0.786 (0.586 to 1.071) for MLA and 1.250 (0.936 to 1.667) for MLD, ruling out proportional bias. The α coefficient was −3.588 (−8.686 to −0.178) for MLA and −1.713 (−3.583 to −0.257) for MLD, indicating an underestimation trend of MSCT. The ROC curve identified an MLA ≤4.7 mm2 as the best threshold to assess in-stent restenosis by MSCT. Conclusions: Agreement between MSCT and IVUS to assess in-stent MLA and MLD for LMCA stenting is good. An MLA of 4.7 mm2 by MSCT is the best threshold to assess binary restenosis. MSCT imaging can be considered in selected patients to assess LMCA in-stent restenosis

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective: To evaluate the agreement between multislice CT (MSCT) and intravascular ultrasound (IVUS) to assess the in-stent lumen diameters and lumen areas of left main coronary artery (LMCA) stents. Design: Prospective, observational single centre study. Setting: A single tertiary referral centre. Patients: Consecutive patients with LMCA stenting excluding patients with atrial fibrillation and chronic renal failure. Interventions: MSCT and IVUS imaging at 9-12 months follow-up were performed for all patients. Main outcome measures: Agreement between MSCT and IVUS minimum luminal area (MLA) and minimum luminal diameter (MLD). A receiver operating characteristic (ROC) curve was plotted to find the MSCT cut-off point to diagnose binary restenosis equivalent to 6 mm2 by IVUS. Results: 52 patients were analysed. Passing-Bablok regression analysis obtained a β coefficient of 0.786 (0.586 to 1.071) for MLA and 1.250 (0.936 to 1.667) for MLD, ruling out proportional bias. The α coefficient was −3.588 (−8.686 to −0.178) for MLA and −1.713 (−3.583 to −0.257) for MLD, indicating an underestimation trend of MSCT. The ROC curve identified an MLA ≤4.7 mm2 as the best threshold to assess in-stent restenosis by MSCT. Conclusions: Agreement between MSCT and IVUS to assess in-stent MLA and MLD for LMCA stenting is good. An MLA of 4.7 mm2 by MSCT is the best threshold to assess binary restenosis. MSCT imaging can be considered in selected patients to assess LMCA in-stent restenosis

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study of noncompact Euclidean cone manifolds with cone angles less than c&2π and singular locus a submanifold. More precisely, we describe its structure outside a compact set. As a corol lary we classify those with cone angles & 2π/3 and those with cone angles = 2π/3.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Estudio elaborado a partir de una estancia en el Karolinska University Hospital, Suecia, entre marzo y junio del 2006. En la radioterapia estereotáxica extracraneal (SBRT) de tumores de pulmón existen principalmente dos problemas en el cálculo de la dosis con los sistemas de planificación disponibles: la precisión limitada de los algoritmos de cálculo en presencia de tejidos con densidades muy diferentes y los movimientos debidos a la respiración del paciente durante el tratamiento. El objetivo de este trabajo ha sido llevar a cabo la simulación con el código Monte Carlo PENELOPE de la distribución de dosis en tumores de pulmón en casos representativos de tratamientos con SBRT teniendo en cuenta los movimientos respiratorios y su comparación con los resultados de varios planificadores. Se han estudiado casos representativos de tratamientos de SBRT en el Karolinska University Hospital. Los haces de radiación se han simulado mediante el código PENELOPE y se han usado para la obtención de los resultados MC de perfiles de dosis. Los resultados obtenidos para el caso estático (sin movimiento respiratorio ) ponen de manifiesto que, en comparación con la MC, la dosis (Gy/MU) calculada por los planificadores en el tumor tiene una precisión del 2-3%. En la zona de interfase entre tumor y tejido pulmonar los planificadores basados en el algoritmo PB sobrestiman la dosis en un 10%, mientras que el algoritmo CC la subestima en un 3-4%. Los resultados de la simulación mediante MC de los movimientos respiratorios indican que los resultados de los planificadores son suficientemente precisos en el tumor, aunque en la interfase hay una mayor subestimación de la dosis en comparación con el caso estático. Estos resultados son compatibles con la experiencia clínica adquirida durante 15 años en el Karolinska University Hospital. Los resultados se han publicado en la revista Acta Oncologica.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lean meat percentage (LMP) is an important carcass quality parameter. The aim of this work is to obtain a calibration equation for the Computed Tomography (CT) scans with the Partial Least Square Regression (PLS) technique in order to predict the LMP of the carcass and the different cuts and to study and compare two different methodologies of the selection of the variables (Variable Importance for Projection — VIP- and Stepwise) to be included in the prediction equation. The error of prediction with cross-validation (RMSEPCV) of the LMP obtained with PLS and selection based on VIP value was 0.82% and for stepwise selection it was 0.83%. The prediction of the LMP scanning only the ham had a RMSEPCV of 0.97% and if the ham and the loin were scanned the RMSEPCV was 0.90%. Results indicate that for CT data both VIP and stepwise selection are good methods. Moreover the scanning of only the ham allowed us to obtain a good prediction of the LMP of the whole carcass.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Lean meat percentage (LMP) is the criterion for carcass classification and it must be measured on line objectively. The aim of this work was to compare the error of the prediction (RMSEP) of the LMP measured with the following different devices: Fat-O-Meat’er (FOM), UltraFOM (UFOM), AUTOFOM and -VCS2000. For this reason the same 99 carcasses were measured using all 4 apparatus and dissected according to the European Reference Method. Moreover a subsample of the carcasses (n=77) were fully scanned with a X-ray Computed Tomography equipment (CT). The RMSEP calculated with cross validation leave-one-out was lower for FOM and AUTOFOM (1.8% and 1.9%, respectively) and higher for UFOM and VCS2000 (2.3% for both devices). The error obtained with CT was the lowest (0.96%) in accordance with previous results, but CT cannot be used on line. It can be concluded that FOM and AUTOFOM presented better accuracy than UFOM and VCS2000.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introducció. Material y mètodes. El nostre objectiu és valorar la utilitat del PET/CT 11C-Colina a la recidiva bioquímica oculta del carcinoma de pròstata. Es van estudiar retrospectivament 58 pacients amb aument de PSA posttractament. La interpretació de les imatges fou visual. Resultats: El PET/CT fou positiu en 39 pacients (67%) (PSA mitjà: 11.7). Es van dividir els malats en 4 grups segons el valor del PSA (sensibilitat%): &1ng/ml:50% 1ng/ml -3ng/ml:60% 3ng/ml-5ng/ml:86% & a 5ng/ml:91% . Conclusió: La PET/CT 11C-Colina mostra una alta capacitat de detecció per valors de PSA superiors a 5ng/ml i pot ser útil en valors superiors a 1ng/ml.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A decentralized model reference controller is designed to reduce the magnitude of the transversal vibration of a flexible cable-stayed beam structure induced by a seismic excitation. The controller design is made based on the principle of sliding mode such that a priori knowledge

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La meningitis és una malaltia de baixa incidència i una presentació clínica variable. En la pràctica clínica habitual és molt freqüent realitzar una tomografia computeritzada (TC) cranial davant la sospita de meningitis. Les dades del nostre estudi són congruents amb les conclusions de les altres sèries de meningitis: els pacients amb sospita clínica de meningitis que no presenten cap alteració a l’exploració neurològica o factor de risc, són bons candidats per la immediata realització de punció lumbar sense necessitat de fer TC prèvia. En la majoria, la TC de crani no aportarà informació rellevant i demorarà considerablement l’inici de l’antibioteràpia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El estudio del hiperparatirodismo es una indicación cada vez más frecuente en Medicina nuclear debido a la incorporación de técnica híbrida SPECT-TC, que añade a la gammagrafía planar convencional de doble trazador (MIBI y Pertecnetato) y doble fase (10 minutos y 2 horas) información sobre localización, fundamentalmente. El sistema de procesado convencional (reconstrucción iterativa OSEM) presenta buenos resultados, no obstante, existen limitaciones como son la resolución espacial y ruido. El sistema de reconstrucción Wide Beam Reconstruction WBR™ mejora fundamentalmente estos aspectos. Con este objetivo, se ha realizado una comparación entre ambos métodos, en pacientes con sospecha de hiperparatiroidismo.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Patient-specific simulations of the hemodynamics in intracranial aneurysms can be constructed by using image-based vascular models and CFD techniques. This work evaluates the impact of the choice of imaging technique on these simulations

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper deals with the impact of "early" nineteenth-century globalization (c.1815-1860) on foreign trade in the Southern Cone (SC). Most of the evidence is drawn from bilateral trades between Britain and the SC, at a time when Britain was the main commercial partner of the new republics. The main conclusion drawn is that early globalization had a positive impact on foreign trade in the SC, and this was due to: improvements in the SC's terms of trade during this period; the SC's per capita consumption of textiles (the main manufacture traded on world markets at that time) increased substantially during this period, at a time when clothing was one of the main items of SC household budgets; British merchants brought with them capital, shipping, insurance, and also facilitated the formation of vast global networks, which further promoted the SC's exports to a wider range of outlets.