9 resultados para Analytes
em Consorci de Serveis Universitaris de Catalunya (CSUC), Spain
Resumo:
Occurrence of polychlorinated dibenzo-p-dioxins (PCDDs) and polychlorinated dibenzofurans (PCDFs) was evaluated in sepiolite as a widely employed binder and anti-caking agent for animal feed. Also, naturally contaminated kaolinitic clay was used for comparative purposes. Since sepiolite shows remarkable adsorption properties, particular interest was paid to the extraction steps as they become critical for the final determination of these pollutants in such matrixes. Furthermore, classical Soxhlet extraction using different extracting strategies as well as acid treatment were carried out with simultaneous liquid-liquid extraction. Results obtained depended on the extraction procedure applied. Acid treatment or Soxhlet extraction using a mixture of toluene:ethanol as solvent allowed to reach the minimum requirements of recovery rates. However, Soxhlet extraction using a mixture cyclohexane:toluene as extracting solvent did not allow to comply with minimum specifications for recovery. Significant differences were obtained in TEQ units when acid treatment was applied in comparison to Soxhlet extraction. This fact can be explained because the use of drastic acid conditions allows removing strongly adsorbed analytes which can be uniquely extracted after a total destruction of the crystalline structure of sepiolite. On the contrary, Soxhlet extraction was not able to destroy the structure of sepiolite and as a consequence the PCDDs/Fs were strongly adsorbed in the internal structure of the mineral. From biological point of view the availability of these toxicants constitutes a critical aspect playing an important role in the final decision choosing particular analytical procedures. Then, acid conditions in the digestive tract should be taken into account. In this scenario, a bioaccumulation study was conducted to evaluate the transference of PCDDs/PCDFs from the sepiolite into the animal tissues when fed with feed containing sepiolite. To this end, chickens were used as a model to examine the bioavailability of PCDDs/PCDFs. Four groups of chickens were exposed through their diet to a control feed, feed with 3% w/w sepiolite as additive, feed contaminated with PCDDs/PCDFs at concentration around 2.8 pg WHO-TEQ/g and feed with 2% of a contaminated kaolinitic clay (460 pg TEQ/g mineral). Livers of the four studied groups were analyzed throughout the exposure period. Results of this trial showed that the performance of broilers was not affected by the presence of dioxins at levels tested, and chickens did not show any abnormal behaviour. Dioxins intentionally added to the diet were absorbed and accumulated in the liver in a significant manner, whereas the PCDDs/Fs from sepiolite were not available for chickens since livers from broilers fed 3% sepiolite presented similar WHO-TEQ values than those from broilers fed control diet.
Resumo:
En este proyecto se desarrolla una unidad de medida para investigar la cuantificación de la concentración de analitos iónicos en análisis clínico mediante sensores ISFET. Para su desarrollo se precisa de un elemento que simule el comportamiento de un ISFET por lo que también se desarrolla un simulador de ISFET. Para realizar la unidad de medida se diseñan unos circuitos SMU que permiten polarizar en tensión y medir la corriente de cada terminal de un ISFET y del electrodo de referencia que actúa de puerta. El simulador se realiza con un MOSFET de la misma geometría que el ISFET y dos generadores de tensión programables. Desarrollados y validados los circuitos correspondientes, obtenemos unos excelentes resultados en el simulador que se revela de gran utilidad para la puesta en marcha de la unidad de medida, la cual ofrece unos resultados bastante buenos, si bien se aprecian ciertas corrientes de fuga que no permiten alcanzar toda la exactitud que se pretendía. Ello es debido a los circuitos impresos que deberán ser mejorados hasta conseguir la exactitud deseada. Sin embargo pueden darse por válidos los circuitos de medida diseñados.
Resumo:
Nanomotors are nanoscale devices capable of converting energy into movement and forces. Among them, self-propelled nanomotors offer considerable promise for developing new and novel bioanalytical and biosensing strategies based on the direct isolation of target biomolecules or changes in their movement in the presence of target analytes. The mainachievements of this project consists on the development of receptor-functionalized nanomotors that offer direct and rapid target detection, isolation and transport from raw biological samples without preparatory and washing steps. For example, microtube engines functionalized with aptamer, antibody, lectin and enzymes receptors were used for the direct isolation of analytes of biomedical interest, including proteins and whole cells, among others. A target protein was also isolated from a complex sample by using an antigen-functionalized microengine navigating into the reservoirs of a lab-on-a-chip device. The new nanomotorbased target biomarkers detection strategy not only offers highly sensitive, rapid, simple and low cost alternative for the isolation and transport of target molecules, but also represents a new dimension of analytical information based on motion. The recognition events can be easily visualized by optical microscope (without any sophisticated analytical instrument) to reveal the target presence and concentration. The use of artificial nanomachines has shown not only to be useful for (bio)recognition and (bio)transport but also for detection of environmental contamination and remediation. In this context, micromotors modified with superhydrophobic layer demonstrated that effectively interacted, captured, transported and removed oil droplets from oil contaminated samples. Finally, a unique micromotor-based strategy for water-quality testing, that mimics live-fish water-quality testing, based on changes in the propulsion behavior of artificial biocatalytic microswimmers in the presence of aquatic pollutants was also developed. The attractive features of the new micromachine-based target isolation and signal transduction protocols developed in this project offer numerous potential applications in biomedical diagnostics, environmental monitoring, and forensic analysis.
Resumo:
Drift is an important issue that impairs the reliability of gas sensing systems. Sensor aging, memory effects and environmental disturbances produce shifts in sensor responses that make initial statistical models for gas or odor recognition useless after a relatively short period (typically few weeks). Frequent recalibrations are needed to preserve system accuracy. However, when recalibrations involve numerous samples they become expensive and laborious. An interesting and lower cost alternative is drift counteraction by signal processing techniques. Orthogonal Signal Correction (OSC) is proposed for drift compensation in chemical sensor arrays. The performance of OSC is also compared with Component Correction (CC). A simple classification algorithm has been employed for assessing the performance of the algorithms on a dataset composed by measurements of three analytes using an array of seventeen conductive polymer gas sensors over a ten month period.
Resumo:
Intrauterine growth restriction (IUGR) is one of the leading causes of perinatal mortality and morbidity. Nowadays, this condition is detected in the 3rt and last trimester of gestation when the pathology is already established and success of therapeutic strategies are limited. As the physiopathology of the disease suggests that the problem stems from poor placental implantation, it would be quite advantageous to identify women at increased risk in the first or second trimester of gestation because it then might be possible to offer treatment interventions or at least to establish increased surveillance for high risk pregnancies. Maternal levels of pregnancy-associated plasma protein-A (PAPP-A) and free β human chorionic gonadotropin (free βhCG) has been shown to be effective in first trimester screening for chromosomal abnormalities, primarily trisomies 21, 13 and 18. Previous studies evaluating PAPP-A and free βhCG measured in the first trimester in relation with IUGR have provided conflicting results. Moreover, it has been suggested that black ethnicity is another important predictive factor for fetal growth restriction.Objective: To analyse the association between first trimester serum analytes (PAPP-A and free βhCG) and ethnicity with Intrauterine Growth Restriction.Methods: The study consists in a retrospective cohort, including all singleton pregnancies with complete outcome data that had undergone first trimester screening (PAPP-A and free βhCG) at 11-13+6weeks of gestation between 1/1/2010 - 31/12/2012 in Hospital Universitari Dr Josep Trueta. Biochemical markers are converted to multiples of the median (MoMs) and percentiles 5 and 10 are calculated. The association between free βhCG and PAPP-A with the incidence of IUGR is evaluated in combination with maternal ethnicity. Bivariate and logistic regression analyses are performed to adjust this association for co variables
Resumo:
Intrauterine growth restriction (IUGR) is one of the leading causes of perinatal mortality and morbidity. Nowadays, this condition is detected in the 3rt and last trimester of gestation when the pathology is already established and success of therapeutic strategies are limited. As the physiopathology of the disease suggests that the problem stems from poor placental implantation, it would be quite advantageous to identify women at increased risk in the first or second trimester of gestation because it then might be possible to offer treatment interventions or at least to establish increased surveillance for high risk pregnancies. Maternal levels of pregnancy-associated plasma protein-A (PAPP-A) and free β human chorionic gonadotropin (free βhCG) has been shown to be effective in first trimester screening for chromosomal abnormalities, primarily trisomies 21, 13 and 18. Previous studies evaluating PAPP-A and free βhCG measured in the first trimester in relation with IUGR have provided conflicting results. Moreover, it has been suggested that black ethnicity is another important predictive factor for fetal growth restriction.Objective: To analyse the association between first trimester serum analytes (PAPP-A and free βhCG) and ethnicity with Intrauterine Growth Restriction.Methods: The study consists in a retrospective cohort, including all singleton pregnancies with complete outcome data that had undergone first trimester screening (PAPP-A and free βhCG) at 11-13+6weeks of gestation between 1/1/2010 - 31/12/2012 in Hospital Universitari Dr Josep Trueta. Biochemical markers are converted to multiples of the median (MoMs) and percentiles 5 and 10 are calculated. The association between free βhCG and PAPP-A with the incidence of IUGR is evaluated in combination with maternal ethnicity. Bivariate and logistic regression analyses are performed to adjust this association for co variables
Resumo:
This work presents a comparison between three analytical methods developed for the simultaneous determination of eight quinolones regulated by the European Union (marbofloxacin, ciprofloxacin, danofloxacin, enrofloxacin, difloxacin, sarafloxacin, oxolinic acid and flumequine) in pig muscle, using liquid chromatography with fluorescence detection (LC-FD), liquid chromatography-mass spectrometry (LC-MS) and liquid chromatography-tandem mass spectrometry (LC-MS/MS). The procedures involve an extraction of the quinolones from the tissues, a step for clean-up and preconcentration of the analytes by solid-phase extraction and a subsequent liquid chromatographic analysis. The limits of detection of the methods ranged from 0.1 to 2.1 ng g−1 using LC-FD, from 0.3 to 1.8 using LC-MS and from 0.2 to 0.3 using LC-MS/MS, while inter- and intra-day variability was under 15 % in all cases. Most of those data are notably lower than the maximum residue limits established by the European Union for quinolones in pig tissues. The methods have been applied for the determination of quinolones in six different commercial pig muscle samples purchased in different supermarkets located in the city of Granada (south-east Spain).
Resumo:
Intrauterine growth restriction (IUGR) is one of the leading causes of perinatal mortality and morbidity. Nowadays, this condition is detected in the 3rt and last trimester of gestation when the pathology is already established and success of therapeutic strategies are limited. As the physiopathology of the disease suggests that the problem stems from poor placental implantation, it would be quite advantageous to identify women at increased risk in the first or second trimester of gestation because it then might be possible to offer treatment interventions or at least to establish increased surveillance for high risk pregnancies. Maternal levels of pregnancy-associated plasma protein-A (PAPP-A) and free β human chorionic gonadotropin (free βhCG) has been shown to be effective in first trimester screening for chromosomal abnormalities, primarily trisomies 21, 13 and 18. Previous studies evaluating PAPP-A and free βhCG measured in the first trimester in relation with IUGR have provided conflicting results. Moreover, it has been suggested that black ethnicity is another important predictive factor for fetal growth restriction.Objective: To analyse the association between first trimester serum analytes (PAPP-A and free βhCG) and ethnicity with Intrauterine Growth Restriction.Methods: The study consists in a retrospective cohort, including all singleton pregnancies with complete outcome data that had undergone first trimester screening (PAPP-A and free βhCG) at 11-13+6weeks of gestation between 1/1/2010 - 31/12/2012 in Hospital Universitari Dr Josep Trueta. Biochemical markers are converted to multiples of the median (MoMs) and percentiles 5 and 10 are calculated. The association between free βhCG and PAPP-A with the incidence of IUGR is evaluated in combination with maternal ethnicity. Bivariate and logistic regression analyses are performed to adjust this association for co variables
Resumo:
Needle trap devices (NTDs) are a relatively new and promising tool for headspace (HS) analysis. In this study, a dynamic HS sampling procedure is evaluated for the determination of volatile organic compounds (VOCs) in whole blood samples. A full factorial design was used to evaluate the influence of the number of cycles and incubation time and it is demonstrated that the controlling factor in the process is the number of cycles. A mathematical model can be used to determine the most appropriate number of cycles required to adsorb a prefixed amount of VOCs present in the HS phase whenever quantitative adsorption is reached in each cycle. Matrix effect is of great importance when complex biological samples, such as blood, are analyzed. The evaluation of the salting out effect showed a significant improvement in the volatilization of VOCs to the HS in this type of matrices. Moreover, a 1:4 (blood:water) dilution is required to obtain quantitative recoveries of the target analytes when external calibration is used. The method developed gives detection limits in the 0.020–0.080 μg L−1 range (0.1–0.4 μg L−1 range for undiluted blood samples) with appropriate repeatability values (RSD < 15% at high level and <23% at LOQ level). Figure of merits of the method can be improved by using a smaller phase ratio (i.e., an increase in the blood volume and a decrease in the HS volume), which lead to lower detection limits, better repeatability values and greater sensibility. Twenty-eight blood samples have been evaluated with the proposed method and the results agree with those indicated in other studies. Benzene was the only target compound that gave significant differences between blood levels detected in volunteer non-smokers and smokers