20 resultados para Air traffic control.

em Consorci de Serveis Universitaris de Catalunya (CSUC), Spain


Relevância:

90.00% 90.00%

Publicador:

Resumo:

Real-time predictions are an indispensable requirement for traffic management in order to be able to evaluate the effects of different available strategies or policies. The combination of predicting the state of the network and the evaluation of different traffic management strategies in the short term future allows system managers to anticipate the effects of traffic control strategies ahead of time in order to mitigate the effect of congestion. This paper presents the current framework of decision support systems for traffic management based on short and medium-term predictions and includes some reflections on their likely evolution, based on current scientific research and the evolution of the availability of new types of data and their associated methodologies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A continuación, mediante una metología clara y coherente, basada principalmente en la metodología propuesta en el libro “Biofiltration for Air Pollution Control de Devinny Joseph S. del año 1999, relacionaremos unos parámetros de entrada o diseño del biofiltro con sus costes de construcción y operación. Aplicaremos a un caso real de un biofiltro estándar e implementaremos dicha metodología para determinar sus costes aproximados.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

La iniciativa ATLANTIDA engloba numerosos estudios de ingeniería con el objetivo de reformar el actual sistema de gestión del tráfico aéreo. Dentro de estos estudios se encuentran diversas investigaciones en el campo de las comunicaciones móviles. La gran variabilidad del entorno aeronáutico promueve el estudio de sistemas de comunicaciones móviles capaces de funcionar en este tipo de entorno. Este proyecto propone un sistema de comunicaciones WiMAX en un entorno aeronáutico con aviones no tripulados utilizando la modulación OFDM.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aquest projecte intenta donar solució al problema amb el qual s’ha trobat la empresa Hitachi Air Conditioning Products SA a la hora de fer probes durant el desenvolupament del seu principal producte, el CSNet Web. El simulador que s’ha realitzat en aquest projecte pretén reproduir la topologia d’una xarxa d’unitats d’aire condicionat per a que el CSNet Web les interpreti com si aquestes màquines fossin reals. Per a aconseguir-ho, el simulador reproduirà les comunicacions entre aquestes màquines i el CSNet Web.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The main goal of this paper is to obtain a granular material formulated with Municipal Solid Waste Incinerarion (MSWI) bottom ash (BA) and air pollution control (APC) ash to be used as secondary building material. Previously, an optimum concrete mixture using both MSWI residues as aggregates was formulated. A compromise between the environmental behaviour and the economy of the process was considered. Unconfined compressive strength and abrasion resistance values were measured in order to evaluate the mechanical properties. From these results, the granular mixture was not suited for certain applications owing to the high BA/APC content and low cement percentages used to reduce the costs of the final product. Nevertheless, the leaching test performed showed that the concentrations of all heavy metals were below the limits established by the current Catalan legislation for their reutilization. Therefore, the material studied might be mainly used in embankments, where high mechanical properties are not needed and environmental safety is assured.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The main goal of this paper is to obtain a granular material formulated with Municipal Solid Waste Incinerarion (MSWI) bottom ash (BA) and air pollution control (APC) ash to be used as secondary building material. Previously, an optimum concrete mixture using both MSWI residues as aggregates was formulated. A compromise between the environmental behaviour and the economy of the process was considered. Unconfined compressive strength and abrasion resistance values were measured in order to evaluate the mechanical properties. From these results, the granular mixture was not suited for certain applications owing to the high BA/APC content and low cement percentages used to reduce the costs of the final product. Nevertheless, the leaching test performed showed that the concentrations of all heavy metals were below the limits established by the current Catalan legislation for their reutilization. Therefore, the material studied might be mainly used in embankments, where high mechanical properties are not needed and environmental safety is assured.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Several airline consolidation events have recently been completed both in Europe and in the United States. The model we develop considers two airlines operating hub-and-spoke networks, using different hubs to connect the same spoke airports. We assume the airlines to be vertically differentiated, which allows us to distinguish between primary and secondary hubs. We conclude that this differentiation in air services becomes more accentuated after consolidation, with an increased number of flights being channeled through the primary hub. However, congestion can act as a brake on the concentration of flight frequency in the primary hub following consolidation. Our empirical application involves an analysis of Delta s network following its merger with Northwest. We find evidence consistent with an increase in the importance of Delta s primary hubs at the expense of its secondary airports. We also find some evidence suggesting that the carrier chooses to divert traffic away from those hub airports that were more prone to delays prior to the merger, in particular New York s JFK airport. Keywords: primary hub; secondary hub; airport congestion; airline consolidation; airline networks JEL Classi fication Numbers: D43; L13; L40; L93; R4

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: Few studies have used longitudinal ultrasound measurements to assess the effect of traffic-related air pollution on fetal growth.Objective: We examined the relationship between exposure to nitrogen dioxide (NO2) and aromatic hydrocarbons [benzene, toluene, ethylbenzene, m/p-xylene, and o-xylene (BTEX)] on fetal growth assessed by 1,692 ultrasound measurements among 562 pregnant women from the Sabadell cohort of the Spanish INMA (Environment and Childhood) study.Methods: We used temporally adjusted land-use regression models to estimate exposures to NO2 and BTEX. We fitted mixed-effects models to estimate longitudinal growth curves for femur length (FL), head circumference (HC), abdominal circumference (AC), biparietal diameter (BPD), and estimated fetal weight (EFW). Unconditional and conditional SD scores were calculated at 12, 20, and 32 weeks of gestation. Sensitivity analyses were performed considering time–activity patterns during pregnancy.Results: Exposure to BTEX from early pregnancy was negatively associated with growth in BPD during weeks 20–32. None of the other fetal growth parameters were associated with exposure to air pollution during pregnancy. When considering only women who spent 2 hr/day in nonresidential outdoor locations, effect estimates were stronger and statistically significant for the association between NO2 and growth in HC during weeks 12–20 and growth in AC, BPD, and EFW during weeks 20–32.Conclusions: Our results lend some support to an effect of exposure to traffic-related air pollutants from early pregnancy on fetal growth during mid-pregnancy.

Relevância:

40.00% 40.00%

Publicador:

Resumo:

Background: Epidemiological evidence of the effects of long-term exposure to air pollu tion on the chronic processes of athero genesis is limited. Objective: We investigated the association of long-term exposure to traffic-related air pollu tion with subclinical atherosclerosis, measured by carotid intima media thickness (IMT) and ankle–brachial index (ABI). Methods: We performed a cross-sectional analysis using data collected during the reexamination (2007–2010) of 2,780 participants in the REGICOR (Registre Gironí del Cor: the Gerona Heart Register) study, a population-based prospective cohort in Girona, Spain. Long-term exposure across residences was calculated as the last 10 years’ time-weighted average of residential nitrogen dioxide (NO2) estimates (based on a local-scale land-use regression model), traffic intensity in the nearest street, and traffic intensity in a 100 m buffer. Associations with IMT and ABI were estimated using linear regression and multinomial logistic regression, respectively, controlling for sex, age, smoking status, education, marital status, and several other potential confounders or intermediates. Results: Exposure contrasts between the 5th and 95th percentiles for NO2 (25 μg/m), traffic intensity in the nearest street (15,000 vehicles/day), and traffic load within 100 m (7,200,000 vehicle-m/day) were associated with differences of 0.56% (95% CI: –1.5, 2.6%), 2.32% (95% CI: 0.48, 4.17%), and 1.91% (95% CI: –0.24, 4.06) percent difference in IMT, respectively. Exposures were positively associated with an ABI of > 1.3, but not an ABI of < 0.9. Stronger associations were observed among those with a high level of education and in men ≥ 60 years of age. Conclusions: Long-term traffic-related exposures were associated with subclinical markers of atherosclerosis. Prospective studies are needed to confirm associations and further examine differences among population subgroups.key words: ankle–brachial index, average daily traffic, cardiovascular disease, exposure assessment, exposure to tailpipe emissions, intima media thickness, land use regression model, Mediterranean diet, nitrogen dioxide

Relevância:

30.00% 30.00%

Publicador:

Resumo:

An examination of the impact in the US and EU markets of two major innovations in the provision of air services on thin routes - regional jet technology and the low-cost business model - reveals significant differences. In the US, regional airlines monopolize a high proportion of thin routes, whereas low-cost carriers are dominant on these routes in Europe. Our results have different implications for business and leisure travelers, given that regional services provide a higher frequency of flights (at the expense of higher fares), while low-cost services offer lower fares (at the expense of lower flight frequencies). Keywords: air transportation; regional jet technology; low-cost business model; thin markets. JEL Classification Numbers: L13; L2; L93.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

El proyecto Web de Control de Tráfico Marítimo (WCTM) un proyecto Web que va a gestionar información útil para el Control del Tráfico Marítimo de una determinada zona del mundo. Usa el concepto de arquitectura SOA, una arquitectura que se basa en los servicios Web, proporciona en tiempo real información sobre los buques usando los mapas de Google.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

TCP flows from applications such as the web or ftp are well supported by a Guaranteed Minimum Throughput Service (GMTS), which provides a minimum network throughput to the flow and, if possible, an extra throughput. We propose a scheme for a GMTS using Admission Control (AC) that is able to provide different minimum throughput to different users and that is suitable for "standard" TCP flows. Moreover, we consider a multidomain scenario where the scheme is used in one of the domains, and we propose some mechanisms for the interconnection with neighbor domains. The whole scheme uses a small set of packet classes in a core-stateless network where each class has a different discarding priority in queues assigned to it. The AC method involves only edge nodes and uses a special probing packet flow (marked as the highest discarding priority class) that is sent continuously from ingress to egress through a path. The available throughput in the path is obtained at the egress using measurements of flow aggregates, and then it is sent back to the ingress. At the ingress each flow is detected using an implicit way and then it is admission controlled. If it is accepted, it receives the GMTS and its packets are marked as the lowest discarding priority classes; otherwise, it receives a best-effort service. The scheme is evaluated through simulation in a simple "bottleneck" topology using different traffic loads consisting of "standard" TCP flows that carry files of varying sizes

Relevância:

30.00% 30.00%

Publicador:

Resumo:

En aquest projecte s'ha dissenyat un sistema informàtic per controlar els esdeveniments produïts per vehicles en zones de trànsit restringit i zones de càrrega i descàrrega. La tecnologia utilitzada és RFID (Radio Frequency Identification Vehicles). Pel que fa al maquinari del projecte, s'ha desenvolupat un sistema a partir d'una placa amb un microcontrolador. Amb aquesta placa es simulen els esdeveniments i s'envien a una màquina amb estructura PC via port Sèrie. Finalment, aquesta màquina processa els esdeveniments rebuts, i els envia a través de la xarxa Ethernet a un servidor central. Pel que fa al programari del projecte, s'ha dissenyat una aplicació web amb llenguatge PHP que processarà les dades rebudes des de la màquina via Ethernet. Un cop l'aplicació rep les dades dels esdeveniments, aquesta s'encarrega d'introduir-les a la base de dades, de manera que aquesta es mantingui actualitzada en tot moment. A més, aquesta aplicació ha de permetre consultar totes les dades sobre els esdeveniments produïts, de manera que es guardi un historial d'aquests

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background: There is growing evidence that traffic-related air pollution reduces birth weight. Improving exposure assessment is a key issue to advance in this research area.Objective: We investigated the effect of prenatal exposure to traffic-related air pollution via geographic information system (GIS) models on birth weight in 570 newborns from the INMA (Environment and Childhood) Sabadell cohort.Methods: We estimated pregnancy and trimester-specific exposures to nitrogen dioxide and aromatic hydrocarbons [benzene, toluene, ethylbenzene, m/p-xylene, and o-xylene (BTEX)] by using temporally adjusted land-use regression (LUR) models. We built models for NO2 and BTEX using four and three 1-week measurement campaigns, respectively, at 57 locations. We assessed the relationship between prenatal air pollution exposure and birth weight with linear regression models. We performed sensitivity analyses considering time spent at home and time spent in nonresidential outdoor environments during pregnancy.Results: In the overall cohort, neither NO2 nor BTEX exposure was significantly associated with birth weight in any of the exposure periods. When considering only women who spent < 2 hr/day in nonresidential outdoor environments, the estimated reductions in birth weight associated with an interquartile range increase in BTEX exposure levels were 77 g [95% confidence interval (CI), 7–146 g] and 102 g (95% CI, 28–176 g) for exposures during the whole pregnancy and the second trimester, respectively. The effects of NO2 exposure were less clear in this subset.Conclusions: The association of BTEX with reduced birth weight underscores the negative role of vehicle exhaust pollutants in reproductive health. Time–activity patterns during pregnancy complement GIS-based models in exposure assessment.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Moltes vegades l’usuari d’una instal•lació de climatització o calefacció, no dóna la suficient importància al sistema que l’hi ha de proporcionar un millor confort amb el màxim rendiment. Aquest confort és un factor determinant, entre molts d’altres, de la “qualitat de vida”. Mentre que el rendiment és un factor important a nivell econòmic i ecològic. Tot i tenir prevalença els aspectes d’estalvi energètic, aquests no impliquen haver de renunciar a un confort tèrmic i a un estalvi econòmic. Un dels aspectes que es centra el projecte és promoure l’ús racional de les fonts energètiques (solar, biomassa) per a la correcta climatització dels habitatges. El projecte es desenvolupa en l’àmbit domèstic, concretament correspon a un habitatge unifamiliar. Aquest està situat a la població de Roda de Ter, província de Barcelona. L’objectiu principal del projecte és l’elecció del sistema de climatització i el seu dimensionament, per tal de donar el màxim confort als usuaris que habitin a la vivenda. Criteris ambientals i eficients han estat objecte a considerar pel disseny constructiu de l’habitatge. Una de les mesures importants presses en el projecte, ha estat l’elecció de les diferents parts que formen la instal•lació de climatització. Es fa referència als aïllaments dels tancaments, el sistema solar de recolzament, equips de producció de fred i calor, entre d’altres. En el projecte, s’ha dut a terme un estudi dels diferents tancaments de l’habitatge, tot determinat per a cada un d’ells, el seu coeficient de transmissió tèrmica. Per seleccionar l’equipament més adequat s’ha partit de les condicions climatològiques del municipi de Roda de Ter i s’ha realitzat el càlcul de les necessitats tèrmiques de l’edifici. L’habitatge incorpora una instal•lació de captació solar tèrmica. Aquesta aportarà un suport energètic a tot el sistema de producció de calor, ja sigui per la producció d’aigua calenta sanitària com per el calefactat de la vivenda. La col•locació dels panells a la façana sud tindrà una doble funció: a més de proporcionar energia solar tèrmica, serviran d’elements de protecció solar en la temporada d’estiu. La caldera usada per donar recolzament tèrmic utilitzarà com a combustible el “pellet”. El “pellet” és un tipus de biomassa llenyosa que consta d’un derivat de la fusta en format granulat. Es defineix i es detalla el consum energètic en biomassa, electricitat i cost econòmic anual que ocasionarà la instal.lació dissenyada. El sistema de terra radiant adoptat permetrà el refrescament en èpoques estivals i el calefactat en èpoques hivernals. Aquest donarà el confort tèrmic necessari a cada estança de l’habitatge. En el projecte també es marquen les pautes bàsiques pel control de la instal•lació solar així com el control dels grups de bombament i la mescla d’aigua del terra radiant.