18 resultados para Accommodating intraocular lens
em Consorci de Serveis Universitaris de Catalunya (CSUC), Spain
Resumo:
L'implant d’una lent intraocular fàquica tipus ICL (Implantable Collamer Lens) pot produir glaucoma agut per tancament angular degut a un bloqueig pupil•lar amb el consegüent augment de la pressió intraocular, el mecanisme i epidemiologia del qual no són ben coneguts. Aquest estudi preliminar pretén avaluar la incidència d'hipertensió ocular i glaucoma agut per tancament angular degut a bloqueig pupil·lar després de l'implant d'una lent posterior fàquica tipus ICL i plantejar hipòtesis sobre el seu mecanisme fisiopatològic.
Resumo:
In this paper we analyze the persistence of aggregate real exchange rates (RERs) for a group of EU-15 countries by using sectoral data. The tight relation between aggregate and sectoral persistence recently investigated by Mayoral (2008) allows us to decompose aggregate RER persistence into the persistence of its different subcomponents. We show that the distribution of sectoral persistence is highly heterogeneous and very skewed to the right, and that a limited number of sectors are responsible for the high levels of persistence observed at the aggregate level. We use quantile regression to investigate whether the traditional theories proposed to account for the slow reversion to parity (lack of arbitrage due to nontradibilities or imperfect competition and price stickiness) are able to explain the behavior of the upper quantiles of sectoral persistence. We conclude that pricing to market in the intermediate goods sector together with price stickiness have more explanatory power than variables related to the tradability of the goods or their inputs.
Resumo:
Sèrie de casos restrospectiva observacional. Es van recollir les dades de 17 casos amb dislocació tardana del complex sac capsular – lent intraocular i que varen necessitar cirurgia per a la seva correcció a l’Hospital de l’Esperança entre Gener de l’any 2000 i Desembre de 2009. Van avaluar-se les característiques dels pacients, possibles factors de risc, condicions i patologies associades, tècnica per a l’extracció de la cataracta i el temps esdevingut entre ambdues cirurgies. Volem descriure les característiques dels casos i formular noves hipòtesi a estudi amb l’objectiu de prevenir i millorar el maneig d’aquesta complicació.
Resumo:
Objectiu: Valorar lent intraocular tòrica en astigmatisme i cataracta. Estudi observacional prospectiu; n: 21 astigmatisme igual o major a 1,5 D. Es valora Astigmatisme, agudesa visual pre operatòria, 1 setmana i 1 mes postoperatori. Eix d'implantació de la lent planificada, a les 24 hores i al mes. Es mesura astigmatisme residual refractiu al mes. N: 21 Astigmatisme preoperatori 2,42 D, astigmatisme 1 mes postoperatori 2,31 D Astigmatisme refractiu 1 mes postoperatori 1,05. Rotació al mes postoperatori 6,82 graus. Agudesa visual 1 mes postoperatori 0,7. La lent és útil en pacients sotmesos a cirurgia de cataracta amb astigmatisme preexistent.
Resumo:
INTRODUCCIÓ: Valorar els resultats funcionals i quirúrgics posteriors a l’explant de la lent intraocular H60M opacificada. MATERIAL I MÈTODES: Estudi retrospectiu de vint-i-cinc ulls sotmesos a intercanvi de H60M opacificada. Anàlisi dels resultats visuals i complicacions, abans, durant i després de l’explante. RESULTATS: Trobarem millors resultats visuals i una menor taxa de complicacions quan no associem vitrectomia anterior a la cirurgia, així como amb la col•locació de la lent secundaria a sulcus. CONCLUSIÓ: L’intercanvi de la LIO Hidroview opacificada suposa un risc quirúrgic addicional, que podem minimitzar durant el període intraoperatori intentant preservar les estructures oculars el més anatòmicament possible.
Resumo:
Aquest document de treball mira d'establir un nou camp d'investigació a la cruïlla entre els fluxos de migració i d'informació i comunicació. Hi ha diversos factors que fan que valgui la pena adoptar aquesta perspectiva. El punt central és que la migració internacional contemporània és incrustada en la dinàmica de la societat de la informació, seguint models comuns i dinàmiques interconnectades. Per consegüent, s'està començant a identificar els fluxos d'informació com a qüestions clau en les polítiques de migració. A més, hi ha una manca de coneixement empíric en el disseny de xarxes d'informació i l'ús de les tecnologies d'informació i comunicació en contextos migratoris. Aquest document de treball també mira de ser una font d'hipòtesis per a investigacions posteriors.
Resumo:
When unmanned underwater vehicles (UUVs) perform missions near the ocean floor, optical sensors can be used to improve local navigation. Video mosaics allow to efficiently process the images acquired by the vehicle, and also to obtain position estimates. We discuss in this paper the role of lens distortions in this context, proving that degenerate mosaics have their origin not only in the selected motion model or in registration errors, but also in the cumulative effect of radial distortion residuals. Additionally, we present results on the accuracy of different feature-based approaches for self-correction of lens distortions that may guide the choice of appropriate techniques for correcting distortions
Resumo:
PROPÒSIT: Estudiar l'efecte de la cirurgia LASIK en la llum dispersa i la sensibilitat al contrast. MÈTODES: Vint-i-vuit pacients van ser tractats amb LASIK. La qualitat visual es va avaluar abans de l'operació i dos mesos després. RESULTATS: La mitjana de llum dispersa i la sensibilitat al contrast abans de l'operació no va canviar en dos mesos després. Només un ull tenia un marcat augment en la llum dispersa. Nou ulls van presentar una lleugera disminució en la sensibilitat al contrast. S'han trobat dues complicacions. CONCLUSIÓ: Després de LASIK la majoria dels pacients (80%) no van tenir complicacions i van mantenir la seva qualitat visual. Uns pocs pacients (16%) van tenir una mica de qualitat visual disminuïda. Molt pocs (4%) van tenir complicacions clíniques amb disminució en la qualitat visual.
Resumo:
The mathematical representation of Brunswik s lens model has been usedextensively to study human judgment and provides a unique opportunity to conduct ameta-analysis of studies that covers roughly five decades. Specifically, we analyzestatistics of the lens model equation (Tucker, 1964) associated with 259 different taskenvironments obtained from 78 papers. In short, we find on average fairly high levelsof judgmental achievement and note that people can achieve similar levels of cognitiveperformance in both noisy and predictable environments. Although overall performancevaries little between laboratory and field studies, both differ in terms of components ofperformance and types of environments (numbers of cues and redundancy). An analysisof learning studies reveals that the most effective form of feedback is information aboutthe task. We also analyze empirically when bootstrapping is more likely to occur. Weconclude by indicating shortcomings of the kinds of studies conducted to date, limitationsin the lens model methodology, and possibilities for future research.
Resumo:
A computer-aided method to improve the thickness uniformity attainable when coating multiple substrates inside a thermal evaporation physical vapor deposition unit is presented. The study is developed for the classical spherical (dome-shaped) calotte and also for a plane sector reversible holder setup. This second arrangement is very useful for coating both sides of the substrate, such as antireflection multilayers on lenses. The design of static correcting shutters for both kinds of configurations is also discussed. Some results of using the method are presented as an illustration.
Resumo:
Aquest document de treball mira d'establir un nou camp d'investigació a la cruïlla entre els fluxos de migració i d'informació i comunicació. Hi ha diversos factors que fan que valgui la pena adoptar aquesta perspectiva. El punt central és que la migració internacional contemporània és incrustada en la dinàmica de la societat de la informació, seguint models comuns i dinàmiques interconnectades. Per consegüent, s'està començant a identificar els fluxos d'informació com a qüestions clau en les polítiques de migració. A més, hi ha una manca de coneixement empíric en el disseny de xarxes d'informació i l'ús de les tecnologies d'informació i comunicació en contextos migratoris. Aquest document de treball també mira de ser una font d'hipòtesis per a investigacions posteriors.
Resumo:
Background: Intraocular pressure (IOP) is the pressure inside the eye that helps to maintain the integrity and the suitable form of the ocular globe. Precise and accurate measures of IOP are needed for the diagnosis as well as follow-up of glaucoma. In daily clinical practice, Goldmann applanation tonometer (GAT) and Non-contact tonometer (NCT) are the most common devices for measuring IOP. A close agreement between these methods has been showed, particularly in normotensive patients and a poor agreement, especially when IOP levels are above the normal range. Ophthalmologists have noticed a poor agreement between NCT and GAT, observing that by using NCT and after comparing with GAT, there is an overestimation of IOP readings, and particularly it occurs when the eyes are tearful. Previous studies investigate the effect of tears in Non-contact tonometer readings by the instillation of artificial tears, concluding in one of the studies that the variation was less than 1mmHg and not clinically significant, in contrast with another study which the increases were sadistically significant. Tear menisci are a thin strip of tear fluid located between the bulbar conjunctiva and the eyelid margins. We think that the overestimation of IOP readings using NCT could be due to the presence of a higher volume of tear in the lower tear meniscus which might cause an optical interference in the optoelectronic applanation monitoring system of this deviceObjectives: To research the influence of a certain volume of fluid in the lower tear meniscus on IOP measurements using the NCT in healthy eyes. Moreover, to investigate the agreement between IOP readings obtained by NCT and GAT in the presence and absence of this volume of fluidMethods: The study design will be transversal for diagnostic tests of repeated measures. We will study patients with no ocular pathology and IOP<21mmHg. It will consist in the measurement of IOP using NCT before and after the instillation of COLIRCUSÍ FLUOTEST, used as a volume of fluid in the lower tear meniscus, to observe if there will be differences using the paired t-test. Moreover, we will take IOP measures by GAT in order to know the agreement between these methods after and before the application of these eyedrops, using the ICC (intraclass correlation coefficient) and the Bland-Altmann method
Resumo:
We present an invariant of a three dimensional manifold with a framed knot in it based on the Reidemeister torsion of an acyclic complex of Euclidean geometric origin. To show its nontriviality, we calculate the invariant for some framed (un)knots in lens spaces. An important feature of our work is that we are not using any nontrivial representation of the manifold fundamental group or knot group.
Resumo:
Aquest treball descriu i s’analitza el procés d’aprovació de la Llei de la Corporació Catalana de Mitjans Audiovisuals, així com la seva impulsació i la posada en funcionament de tal legislació. Després de fer un repàs al context pel qual sorgeix la llei, es fa un anàlisi de les controvèrsies que ha generat, al voltant de l’independència política que busca, amb menys o més èxit l’ens que engloba els mitjans de comunicació públics de Catalunya.
Resumo:
Objectiu: Analitzar les diferents formes clíniques d’uveïtis en pacients amb esclerosi múltiple (EM), el seu tractament i resultats. Mètode: Estudi retrospectiu de 18 pacients diagnosticats d’EM que van presentar episodis d’inflamació intraocular clínicament rellevants. Resultats: La forma clínica predominant va ser la uveïtis intermèdia (14 casos), seguida de la forma vasculítica (2 casos). El tractament mèdic va aconseguir una milloria global de 1’68 ± 1,47 línies de visió; mentre que la cirurgia va mostrar una milloria de 3,36 ± 2,46 línies de visió rere la facoemulsificació, i de 2,25 ± 0,56 línies de visió rere la vitrectomia. Conclusions: El tractament amb corticoides locals o sistèmics assoleix un adequat control de la majoria dels episodis d’inflamació intraocular. Els resultats de la cirurgia son molt satisfactoris en aquest grup de pacients, un cop controlats mèdicament els brots d’activitat inflamatòria intraocular.