108 resultados para SMOKE DETECTORS
Resumo:
We present here new observations conducted with the EVN and MERLIN of the persistent microquasar LS 5039 discovered by Paredes et al. (2000) with the VLBA. The new observations confirm the presence of an asymmetric two-sided jet reaching up to 1000 AU on the longest jet arm. The results suggest a bending of the jets with increasing distance from the core and/or precession. The origin and location of the high-energy gamma-ray emission associated with the system is discussed and an estimate of the magnetic field at the base of the jet given. Our results suggest a well collimated radio jet. We also comment on new observing strategies to be used with satellites and forthcoming detectors, since this persistent source appears to be a rather good laboratory to explore the accretion/ejection processes taking place near compact objects.
Resumo:
Background: Diverse projects and guidelines to assist hospitals towards the attainment of comprehensive smoke-free policies have been developed. In 2006, Spain government passed a new smoking ban that reinforce tobacco control policies and banned completely smoking in hospitals. This study assesses the progression of tobacco control policies in the Catalan Network of Smokefree Hospitals before and after a comprehensive national smoking ban. Methods: We used the Self-Audit Questionnaire of the European Network for Smoke-free Hospitals to score the compliance of 9 policy standards (global score = 102). We used two crosssectional surveys to evaluate tobacco control policies before (2005) and after the implementation of a national smoking ban (2007) in 32 hospitals of Catalonia, Spain. We compared the means of the overall score in 2005 and 2007 according to the type of hospital, the number of beds, the prevalence of tobacco consumption, and the number of years as a smoke-free hospital. Results: The mean of the implementation score of tobacco control policies was 52.4 (95% CI:45.4-59.5) in 2005 and 71.6 (95% CI: 67.0-76.2) in 2007 with an increase of 36.7% (p < 0.01). The hospitals with greater improvement were general hospitals (48% increase; p < 0.01), hospitals with > 300 beds (41.1% increase; p < 0.01), hospitals with employees' tobacco consumption prevalence 35-39% (72.2% increase; p < 0.05) and hospitals that had recently implemented smoke-free policies (74.2% increase; p < 0.01). Conclusion: The national smoking ban appears to increase tobacco control activities in hospitals combined with other non-bylaw initiatives such as the Smoke-free Hospital Network.
Resumo:
Background: Diverse projects and guidelines to assist hospitals towards the attainment of comprehensive smoke-free policies have been developed. In 2006, Spain government passed a new smoking ban that reinforce tobacco control policies and banned completely smoking in hospitals. This study assesses the progression of tobacco control policies in the Catalan Network of Smokefree Hospitals before and after a comprehensive national smoking ban. Methods: We used the Self-Audit Questionnaire of the European Network for Smoke-free Hospitals to score the compliance of 9 policy standards (global score = 102). We used two crosssectional surveys to evaluate tobacco control policies before (2005) and after the implementation of a national smoking ban (2007) in 32 hospitals of Catalonia, Spain. We compared the means of the overall score in 2005 and 2007 according to the type of hospital, the number of beds, the prevalence of tobacco consumption, and the number of years as a smoke-free hospital. Results: The mean of the implementation score of tobacco control policies was 52.4 (95% CI:45.4-59.5) in 2005 and 71.6 (95% CI: 67.0-76.2) in 2007 with an increase of 36.7% (p < 0.01). The hospitals with greater improvement were general hospitals (48% increase; p < 0.01), hospitals with > 300 beds (41.1% increase; p < 0.01), hospitals with employees' tobacco consumption prevalence 35-39% (72.2% increase; p < 0.05) and hospitals that had recently implemented smoke-free policies (74.2% increase; p < 0.01). Conclusion: The national smoking ban appears to increase tobacco control activities in hospitals combined with other non-bylaw initiatives such as the Smoke-free Hospital Network.
Resumo:
In this paper we design and develop several filtering strategies for the analysis of data generated by a resonant bar gravitational wave (GW) antenna, with the goal of assessing the presence (or absence) therein of long-duration monochromatic GW signals, as well as the eventual amplitude and frequency of the signals, within the sensitivity band of the detector. Such signals are most likely generated in the fast rotation of slightly asymmetric spinning stars. We develop practical procedures, together with a study of their statistical properties, which will provide us with useful information on the performance of each technique. The selection of candidate events will then be established according to threshold-crossing probabilities, based on the Neyman-Pearson criterion. In particular, it will be shown that our approach, based on phase estimation, presents a better signal-to-noise ratio than does pure spectral analysis, the most common approach.
Resumo:
Three different pixels based on single-photon avalanche diodes for triggered applications, such as fluorescence lifetime measurements and high energy physics experiments, are presented. Each pixel consists of a 20µm x 100µm (width x length) single photon avalanche diode and a monolithically integrated readout circuit. The sensors are operated in the gated mode of acquisition to reduce the probability to detect noise counts interferring with real radiation events. Each pixel includes a different readout circuit that allows to use low reverse bias overvoltages. Experimental results demonstrate that the three pixels present a similar behaviour. The pixels get rid of afterpulses and present a reduced dark count probability by applying the gated operation. Noise figures are further improved by using low reverse bias overvoltages. The detectors exhibit an input dynamic range of 13.35 bits with short gated"on" periods of 10ns and a reverse bias overvoltage of 0.5V. The three pixels have been fabricated in a standard HV-CMOS process.
Resumo:
Chronic obstructive pulmonary disease (COPD) is a lethal progressive lung disease culminating in permanent airway obstruction and alveolar enlargement. Previous studies suggest CTL involvement in COPD progression; however, their precise role remains unknown. Here, we investigated whether the CTL activation receptor NK cell group 2D (NKG2D) contributes to the development of COPD. Using primary murine lung epithelium isolated from mice chronically exposed to cigarette smoke and cultured epithelial cells exposed to cigarette smoke extract in vitro, we demonstrated induced expression of the NKG2D ligand retinoic acid early tran - script 1 (RAET1)as well as NKG2D-mediated cytotoxicity. Furthermore, a genetic model of inducible RAET1 expression on mouse pulmonary epithelial cells yielded a severe emphysematous phenotype characterized by epithelial apoptosis and increased CTL activation, which was reversed by blocking NKG2D activation. We also assessed whether NKG2D ligand expression corresponded with pulmonary disease in human patients by staining airway and peripheral lung tissues from never smokers, smokers with normal lung function, and current and former smokers with COPD. NKG2D ligand expression was independent of NKG2D receptor expression in COPD patients, demonstrating that ligand expression is the limiting factor in CTL activation. These results demonstrate that aberrant, persistent NKG2D ligand expression in the pulmonary epithelium contributes to the development of COPD pathologies.
Resumo:
Different asymmetries between expansion and contraction (radial motions) have been reported in the literature. Often these patterns have been regarded as implying different channels for each type of radial direction (outward versus inwards) operating at a higher level of visual motion processing. In two experiments (detection and discrimination tasks) we report reaction time asymmetries between expansion and contraction. Power functions were fitted to the data. While an exponent of 0.5 accounted for the expansion data better, a value of unity yielded the best fit for the contraction data. Instead of interpreting these differences as corresponding to different higher order motion detectors, we regard these findings as reflecting the fact that expansion and contraction tap two distinct psychophysical input channels underlying the processing of fast and slow velocities respectively.
Resumo:
Quartz Tuning Fork (QTF)-based Scanning Probe Microscopy (SPM) is an important field of research. A suitable model for the QTF is important to obtain quantitative measurements with these devices. Analytical models have the limitation of being based on the double cantilever configuration. In this paper, we present an electromechanical finite element model of the QTF electrically excited with two free prongs. The model goes beyond the state-of-the-art of numerical simulations currently found in the literature for this QTF configuration. We present the first numerical analysis of both the electrical and mechanical behavior of QTF devices. Experimental measurements obtained with 10 units of the same model of QTF validate the finite element model with a good agreement.
Resumo:
En este trabajo se presenta un estudio químico y estructural de las capas metálicas de Pt y TaSix utilizadas como puerta catalítica en sensores de gas de alta temperatura basados en dispositivos MOS de SiC. Para ello se han depositado capas de diferentes espesores sobre substratos de Si. Los resultados muestran que con la reducción del espesor de Pt y con un recocido se consigue aumentar la rugosidad de las capas de puerta, lo que debería aumentar la sensibilidad y la velocidad de respuesta de los dispositivos que las incorporasen. Otro efecto del recocido es la transformación química del material de la puerta que, para capas delgadas de Pt con TaSix, produce la transformación total Pt en Pt2Ta, lo que podría afectar a las características catalíticas de la puerta. Los primeros resultados eléctricos indican que, a pesar de que las capas de Pt empleadas son gruesas y compactas, los diodos MOS túnel de SiC son sensibles a los gases CO y NO2, aunque presentan una velocidad de respuesta bastante lenta.
Resumo:
Virtual Reality environments that reproduce typical contexts associated with tobacco use may be useful for aiding smoking cessation. The main objective of this study was to assess the capacity of eight environments to produce the craving to smoke and determine the relation of craving to nicotine dependence and level of presence. The results show that all the environments were able to generate the desire to smoke; a direct relation was found between sense of presence and craving.
Resumo:
Cue exposure treatment (CET) consists of controlled and repeated exposure to drugrelated stimuli in order to reduce cue-reactivity. Virtual reality (VR) has proved to be a promising tool for exposition. However, identifying the variables that can modulate the efficacy of this technique is essential for selecting the most appropriate exposure modality. The aim of this study was to determine the relation between several individual variables and self-reported craving in smokers exposed to VR environments. Fortysix smokers were exposed to seven complex virtual environments that reproduce typical situations in which people smoke. Self-reported craving was selected as the criterion variable and three types of variables were selected as the predictor variables: related to nicotine dependence, related to anxiety and impulsivity, and related to the sense of presence in the virtual environments. Sense of presence was the only predictor of self-reported craving in all the experimental virtual environments. Nicotine dependence variables added predictive power to the model only in the virtual breakfast at home. No relation was found between anxiety or impulsivity and self-reported craving. Virtual reality technology can be very helpful for improving CET for substance use disorders. However, the use of virtual environments would make sense only insofar as the sense of presence was high. Otherwise, the effectiveness of exposure might be affected. © 2012 by the Massachusetts Institute of Technology.
Resumo:
This work proposes a fully-digital interface circuit for the measurement of inductive sensors using a low-cost microcontroller (µC) and without any intermediate active circuit. Apart from the µC and the sensor, the circuit just requires an external resistor and a reference inductance so that two RL circuits with a high-pass filter (HPF) topology are formed. The µC appropriately excites such RL circuits in order to measure the discharging time of the voltage across each inductance (i.e. sensing and reference) and then it uses such discharging times to estimate the sensor inductance. Experimental tests using a commercial µC show a non-linearity error (NLE) lower than 0.5%FSS (Full-Scale Span) when measuring inductances from 1 mH to 10 mH, and from 10 mH to 100 mH.
Resumo:
This paper proposes the use of an autonomous assistant mobile robot in order to monitor the environmental conditions of a large indoor area and develop an ambient intelligence application. The mobile robot uses single high performance embedded sensors in order to collect and geo-reference environmental information such as ambient temperature, air velocity and orientation and gas concentration. The data collected with the assistant mobile robot is analyzed in order to detect unusual measurements or discrepancies and develop focused corrective ambient actions. This paper shows an example of the measurements performed in a research facility which have enabled the detection and location of an uncomfortable temperature profile inside an office of the research facility. The ambient intelligent application has been developed by performing some localized ambient measurements that have been analyzed in order to propose some ambient actuations to correct the uncomfortable temperature profile.
Resumo:
La presente solicitud de patente tiene por objeto un dispositivo y método para medir magnitudes eléctricas de sensores analógicos, que 10 incorpora notables innovaciones y ventajas.La presente invención se refiere, en general, a los sistemas de medida de sensores analógicos, incluidos aquellos que generan directamente una corriente o una tensión eléctrica.
Resumo:
El treball presentat ve motivat per la necessitat d’instal•lació d’un pàrquing públic i privat de nova construcció a nivell d’il•luminació i ventilació. Per poder satisfer les necessitats del nostre client d’estalvi energètic i confort en l’edifici es decideix d’implementar una instal•lació immòtica que és l’aplicació de tècniques de gestió i control automatitzat a un edifici terciari amb bus de comunicació KNX/EIB. Per a la il•luminació s’han utilitzat fluorescents amb balasts DALI, que permeten la seva regulació i control, per així poder adequar en tot moment l’encesa i intensitat de llum d’aquests. En quant a la ventilació s’han utilitzat variadors de freqüència per també poder optimitzar el funcionament dels ventiladors podent posar-los en marxa quan realment sigui necessari i a la potència que calgui. Per enllaçar tots els elements de la instal•lació, detectors i actuadors, sorgeig la necessitat d’implementar xarxes de comunicació com el KNX/EIB, DALI, Modbus i Ethernet. Per gestionar variables, comunicacions i controlar elements, s´hi han implementen dos autòmats programables a més d’un PC integrat per la visualització i el control del pàrquing. S’ha aconseguit de realitzar un pàrquing totalment automàtic on no és necessaria l’actuació dels operaris i amb les principals càrregues elèctriques totalment regulables en potència. S’ha comprovat que la instal•lació funciona per sota de la potència nominal de les càrregues amb l’estalvi energètic que això suposa.