73 resultados para quality characteristic
Resumo:
It is shown that Hirzebruch's result on the Chern classes of a complete intersection of nonsingular hypersurfaces in general position in PN(C), is also valid for any nonsingular complete intersection. Then rela- tions between Euler characteristic, class and Milnor number are pointed out.
Resumo:
[eng] ISO standard 9001 is one of a set of management tools that libraries have adopted in recent years. This article focuses on libraries in higher education institutions that have received ISO certification of their quality management systems (ISO standard 9001:2000). We examine their reasons for seeking certification and the advantages and difficulties they have encountered in applying this ISO standard. Finally, we consider the future prospects of ISO standard 9001 in university libraries.
Resumo:
Background: Quality control procedures vary considerably among the providers of equipment for home mechanical ventilation (HMV). Methods: A multicentre quality control survey of HMV was performed at the home of 300 patients included in the HMV programmes of four hospitals in Barcelona. It consisted of three steps: (1) the prescribed ventilation settings, the actual settings in the ventilator control panel, and the actual performance of the ventilator measured at home were compared; (2) the different ventilator alarms were tested; and (3) the effect of differences between the prescribed settings and the actual performance of the ventilator on non-programmed readmissions of the patient was determined. Results: Considerable differences were found between actual, set, and prescribed values of ventilator variables; these differences were similar in volume and pressure preset ventilators. The percentage of patients with a discrepancy between the prescribed and actual measured main ventilator variable (minute ventilation or inspiratory pressure) of more than 20% and 30% was 13% and 4%, respectively. The number of ventilators with built in alarms for power off, disconnection, or obstruction was 225, 280 and 157, respectively. These alarms did not work in two (0.9%), 52 (18.6%) and eight (5.1%) ventilators, respectively. The number of non-programmed hospital readmissions in the year before the study did not correlate with the index of ventilator error. Conclusions: This study illustrates the current limitations of the quality control of HMV and suggests that improvements should be made to ensure adequate ventilator settings and correct ventilator performance and ventilator alarm operation.
Resumo:
In this article, we analyze the ability of the early olfactory system to detect and discriminate different odors by means of information theory measurements applied to olfactory bulb activity images. We have studied the role that the diversity and number of receptor neuron types play in encoding chemical information. Our results show that the olfactory receptors of the biological system are low correlated and present good coverage of the input space. The coding capacity of ensembles of olfactory receptors with the same receptive range is maximized when the receptors cover half of the odor input space - a configuration that corresponds to receptors that are not particularly selective. However, the ensemble's performance slightly increases when mixing uncorrelated receptors of different receptive ranges. Our results confirm that the low correlation between sensors could be more significant than the sensor selectivity for general purpose chemo-sensory systems, whether these are biological or biomimetic.
Resumo:
We present our recent achievements in the growing and optical characterization of KYb(WO4)2 (hereafter KYbW) crystals and demonstrate laser operation in this stoichiometric material. Single crystals of KYbW with optimal crystalline quality have been grown by the top-seeded-solution growth slow-cooling method. The optical anisotropy of this monoclinic crystal has been characterized, locating the tensor of the optical indicatrix and measuring the dispersion of the principal values of the refractive indices as well as the thermo-optic coefficients. Sellmeier equations have been constructed valid in the visible and near-IR spectral range. Raman scattering has been used to determine the phonon energies of KYbW and a simple physical model is applied for classification of the lattice vibration modes. Spectroscopic studies (absorption and emission measurements at room and low temperature) have been carried out in the spectral region near 1 µm characteristic for the ytterbium transition. Energy positions of the Stark sublevels of the ground and the excited state manifolds have been determined and the vibronic substructure has been identified. The intrinsic lifetime of the upper laser level has been measured taking care to suppress the effect of reabsorption and the intrinsic quantum efficiency has been estimated. Lasing has been demonstrated near 1074 nm with 41% slope efficiency at room temperature using a 0.5 mm thin plate of KYbW. This laser material holds great promise for diode pumped high-power lasers, thin disk and waveguide designs as well as for ultrashort (ps/fs) pulse laser systems.
Resumo:
A systematic method to improve the quality (Q) factor of RF integrated inductors is presented in this paper. The proposed method is based on the layout optimization to minimize the series resistance of the inductor coil, taking into account both ohmic losses, due to conduction currents, and magnetically induced losses, due to eddy currents. The technique is particularly useful when applied to inductors in which the fabrication process includes integration substrate removal. However, it is also applicable to inductors on low-loss substrates. The method optimizes the width of the metal strip for each turn of the inductor coil, leading to a variable strip-width layout. The optimization procedure has been successfully applied to the design of square spiral inductors in a silicon-based multichip-module technology, complemented with silicon micromachining postprocessing. The obtained experimental results corroborate the validity of the proposed method. A Q factor of about 17 have been obtained for a 35-nH inductor at 1.5 GHz, with Q values higher than 40 predicted for a 20-nH inductor working at 3.5 GHz. The latter is up to a 60% better than the best results for a single strip-width inductor working at the same frequency.
Resumo:
Epitaxial Fe/MgO heterostructures have been grown on Si(001) by a combination of sputtering and laser ablation deposition techniques. The growth of MgO on Si(001) is mainly determined by the nature of the interface, with large lattice mismatch and the presence of an amorphous layer of unclear origin. Reflection high energy electron diffraction patterns of this MgO buffer layer are characteristic of an epitaxial, but disordered, structure. The structural quality of subsequent Fe and MgO layers continuously improves due to the better lattice match and the burial of defects. A weak uniaxial in-plane magnetic anisotropy is found superimposed on the expected cubic biaxial anisotropy. This additional anisotropy, of interfacial nature and often found in Fe/MgO and Fe/MgO/GaAs(001) systems, is less intense here due to the poorer MgO/Si interface quality compared with that of other systems. From the evolution of the anisotropy field with film thickness, magnetic anisotropy is also found to depend on the crystal quality. Kerr measurements of a Fe/MgO multilayered structure grown on Si show two different switching fields, suggesting magnetic coupling of two of the three Fe layers. Nevertheless, due to the little sensitivity to the bottom Fe film, independent switching of the three layers cannot be ruled out.
Resumo:
La aplicabilidad, repetibilidad y capacidad de diferentes métodos de análisis para discriminar muestras de aceites con diferentes grados de oxidación fueron evaluadas mediante aceites recogidos en procesos de fritura en continuo en varias empresas españolas. El objetivo de este trabajo fue encontrar métodos complementarios a la determinación del índice de acidez para el control de calidad rutinario de los aceites de fritura empleados en estas empresas. La optimización de la determinación de la constante dieléctrica conllevó una clara mejora de la variabilidad. No obstante, excepto en el caso del índice del ATB, el resto de métodos ensayados mostraron una menor variabilidad. La determinación del índice del ATB fue descartada ya que su sensibilidad fue insuficiente para discriminar entre aceites con diferente grado de oxidación. Los diferentes parámetros de alteración determinados en los aceites de fritura mostraron correlaciones significativas entre el índice de acidez y varios parámetros de oxidación diferentes, como la constante dieléctrica, el índice de p-anisidina, la absorción al ultravioleta y el contenido en polímeros de los triacilgliceroles. El índice de acidez solo evalúa la alteración hidrolítica, por lo que estos parámetros aportan información complementaria al evaluar la alteración termooxidativa.
Resumo:
1. The effects of "cafeteria feeding" on primiparous Wistar rats during lactation have been studied by measuring circulating levels of glucose, amino acids, lactate, urea and ammonia as well as glycogen levels in liver and muscle. 2. No significant changes in glucose levels were observed despite alterations in blood glucose compartmentation. 3. Compared with controls, the dams given the cafeteria diet had higher liver glycogen stores which were more easily mobilized at the peak of lactation. 4. Rats given the cafeteria diet showed a lower amino acid utilization than controls and adequately maintained circulating levels, as determined by the lower circulating levels of ammonia and urea. 5. No significant differences in body-weight were observed in the period studied despite increasing dam weight after weaning in the cafeteria-fed group. 6. The size of pups of cafeteria-fed dams was greater than that of controls, and the differences were marked after weaning, when the metabolic machinery of the cafeteria pup maintained high protein accretion and body build-up using fat as the main energy substrate characteristic of the preweaning stage. The controls, however, changed to greater utilization of amino acids as an energy substrate and adapted to high-protein (lowbiological-quality) diets with a significantly different pattern of circulating nitrogen distribution.
Resumo:
By means of the ab initio cluster-model approach, we present theoretical evidence for two different mechanisms of bonding of atomic Al to Si(111). On the atop site (T1) the interaction of atomic Al to Si(111) is characteristic of an ionic bond whereas interaction above the threefold eclipsed site (T4) leads to the formation of a typical covalent bond. Moreover, both sites have a similar interaction energy if electronic correlation effects are included. While the conclusions regarding the nature of the chemisorption bond in the two sites do not depend either on the cluster-model size, the kind of embedding hydrogen atoms used, or the quality of the wave function (Hartree-Fock or configuration interaction), the chemisorption energy depends strongly on the wave function used. In fact, inclusion of correlation energy is necessary to properly describe the interaction energies.
Resumo:
The phenomenon of human migration is certainly not new and it has been studied from a variety of perspectives. Yet, the attention on human migration and its determinant has not been fading over time as confirmed by recent contributions (see for instance Cushing and Poot 2004 and Rebhun and Raveh 2006). In this paper we combine the recent theoretical contributions by Douglas (1997) and Wall (2001) with the methodological advancements of Guimarães et al. (2000, 2003) to model inter-municipal migration flows in the Barcelona area. In order to do that, we employ two different types of count models, i.e. the Poisson and negative binomial and compare the estimations obtained. Our results show that, even after controlling for the traditional migration factors, QoL (measured with a Composite Index which includes numerous aspects and also using a list of individual variables) is an important determinant of short distance migration movements in the Barcelona area.
Resumo:
Background: The aim of this research was to characterize the experience of living with diabetes mellitus (DM) and identify patients" opinions of the quality of care received and the results of interventions. Methods: A descriptive, exploratory evaluation study using qualitative methodology was performed. Participants consisted of 40 adult patients diagnosed with DM and followed up in a public hospital in Barcelona, Spain. A semistructured interview and a focus group were used and a thematic content analysis was performed. Results: Patients described DM as a disease that is difficult to control and that provokes lifestyle changes requiring effort and sacrifice. Insulin treatment increased the perception of disease severity. The most frequent and dreaded complication was hypoglycemia. The main problems perceived by patients affecting the quality of care were related to a disease-centered medical approach, lack of information, limited participation in decision-making, and the administrative and bureaucratic problems of the health care system. Conclusion: The bureaucratic circuits of the health care system impair patients" quality of life and perceived quality of care. Health professionals should foster patient participation in decision-making. However, this requires not only training and appropriate attitudes, but also adequate staffing and materials.