67 resultados para quality at universities
Resumo:
[eng] ISO standard 9001 is one of a set of management tools that libraries have adopted in recent years. This article focuses on libraries in higher education institutions that have received ISO certification of their quality management systems (ISO standard 9001:2000). We examine their reasons for seeking certification and the advantages and difficulties they have encountered in applying this ISO standard. Finally, we consider the future prospects of ISO standard 9001 in university libraries.
Resumo:
[cat] Aquest article descriu el procés d'implantació d'un sistema de gestió de la documentació administrativa al Departament d'Universitats, Recerca i Societat de la Informació de la Generalitat de Catalunya (actualment Departament d'Innovació, Universitats i Empresa). El projecte, anomenat DursiGED, ha inclòs l'anàlisi, el desenvolupament i la implantació dels productes i serveis necessaris per gestionar la documentació electrònica i en suport paper de manera normalitzada i d'acord amb uns paràmetres de qualitat. L'article inclou la descripció de la planificació del projecte, el procés d'implantació i seguiment, i els productes i serveis que n'han resultat.
Resumo:
Background: Quality control procedures vary considerably among the providers of equipment for home mechanical ventilation (HMV). Methods: A multicentre quality control survey of HMV was performed at the home of 300 patients included in the HMV programmes of four hospitals in Barcelona. It consisted of three steps: (1) the prescribed ventilation settings, the actual settings in the ventilator control panel, and the actual performance of the ventilator measured at home were compared; (2) the different ventilator alarms were tested; and (3) the effect of differences between the prescribed settings and the actual performance of the ventilator on non-programmed readmissions of the patient was determined. Results: Considerable differences were found between actual, set, and prescribed values of ventilator variables; these differences were similar in volume and pressure preset ventilators. The percentage of patients with a discrepancy between the prescribed and actual measured main ventilator variable (minute ventilation or inspiratory pressure) of more than 20% and 30% was 13% and 4%, respectively. The number of ventilators with built in alarms for power off, disconnection, or obstruction was 225, 280 and 157, respectively. These alarms did not work in two (0.9%), 52 (18.6%) and eight (5.1%) ventilators, respectively. The number of non-programmed hospital readmissions in the year before the study did not correlate with the index of ventilator error. Conclusions: This study illustrates the current limitations of the quality control of HMV and suggests that improvements should be made to ensure adequate ventilator settings and correct ventilator performance and ventilator alarm operation.
Resumo:
In this article, we analyze the ability of the early olfactory system to detect and discriminate different odors by means of information theory measurements applied to olfactory bulb activity images. We have studied the role that the diversity and number of receptor neuron types play in encoding chemical information. Our results show that the olfactory receptors of the biological system are low correlated and present good coverage of the input space. The coding capacity of ensembles of olfactory receptors with the same receptive range is maximized when the receptors cover half of the odor input space - a configuration that corresponds to receptors that are not particularly selective. However, the ensemble's performance slightly increases when mixing uncorrelated receptors of different receptive ranges. Our results confirm that the low correlation between sensors could be more significant than the sensor selectivity for general purpose chemo-sensory systems, whether these are biological or biomimetic.
Resumo:
A systematic method to improve the quality (Q) factor of RF integrated inductors is presented in this paper. The proposed method is based on the layout optimization to minimize the series resistance of the inductor coil, taking into account both ohmic losses, due to conduction currents, and magnetically induced losses, due to eddy currents. The technique is particularly useful when applied to inductors in which the fabrication process includes integration substrate removal. However, it is also applicable to inductors on low-loss substrates. The method optimizes the width of the metal strip for each turn of the inductor coil, leading to a variable strip-width layout. The optimization procedure has been successfully applied to the design of square spiral inductors in a silicon-based multichip-module technology, complemented with silicon micromachining postprocessing. The obtained experimental results corroborate the validity of the proposed method. A Q factor of about 17 have been obtained for a 35-nH inductor at 1.5 GHz, with Q values higher than 40 predicted for a 20-nH inductor working at 3.5 GHz. The latter is up to a 60% better than the best results for a single strip-width inductor working at the same frequency.
Resumo:
La aplicabilidad, repetibilidad y capacidad de diferentes métodos de análisis para discriminar muestras de aceites con diferentes grados de oxidación fueron evaluadas mediante aceites recogidos en procesos de fritura en continuo en varias empresas españolas. El objetivo de este trabajo fue encontrar métodos complementarios a la determinación del índice de acidez para el control de calidad rutinario de los aceites de fritura empleados en estas empresas. La optimización de la determinación de la constante dieléctrica conllevó una clara mejora de la variabilidad. No obstante, excepto en el caso del índice del ATB, el resto de métodos ensayados mostraron una menor variabilidad. La determinación del índice del ATB fue descartada ya que su sensibilidad fue insuficiente para discriminar entre aceites con diferente grado de oxidación. Los diferentes parámetros de alteración determinados en los aceites de fritura mostraron correlaciones significativas entre el índice de acidez y varios parámetros de oxidación diferentes, como la constante dieléctrica, el índice de p-anisidina, la absorción al ultravioleta y el contenido en polímeros de los triacilgliceroles. El índice de acidez solo evalúa la alteración hidrolítica, por lo que estos parámetros aportan información complementaria al evaluar la alteración termooxidativa.
Resumo:
The phenomenon of human migration is certainly not new and it has been studied from a variety of perspectives. Yet, the attention on human migration and its determinant has not been fading over time as confirmed by recent contributions (see for instance Cushing and Poot 2004 and Rebhun and Raveh 2006). In this paper we combine the recent theoretical contributions by Douglas (1997) and Wall (2001) with the methodological advancements of Guimarães et al. (2000, 2003) to model inter-municipal migration flows in the Barcelona area. In order to do that, we employ two different types of count models, i.e. the Poisson and negative binomial and compare the estimations obtained. Our results show that, even after controlling for the traditional migration factors, QoL (measured with a Composite Index which includes numerous aspects and also using a list of individual variables) is an important determinant of short distance migration movements in the Barcelona area.