66 resultados para Lower flammability limits


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To determine the incidence, severity and duration of lingual tactile and gustatory function impairments after lower third molar removal. Study Design: Prospective cohort study with intra-subject measures of 16 patients undergoing lower third molar extractions. Sensibility and gustatory functions were evaluated in each subject preoperatively, one week and one month after the extraction, using Semmes-Weinstein monofilaments and 5 different concentrations of NaCl, respectively. Additionally, all patients filled a questionnaire to assess subjective perceptions. Results: Although patients did not perceive any sensibility impairments, a statistically significant decrease was detected when Semmes-Weinstein monofilaments. This alteration was present at one week after the surgical procedure and fully recovered one month after the extraction. There were no variations regarding the gustatory function. Conclusions: Lower third molar removal under local anesthesia may cause light lingual sensibility impairment. Most of these alterations remain undetected to patients. These lingual nerve injuries are present one week after the extraction and recover one month after surgery. The taste seems to remain unaffected after these procedures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: The purpose of this study was to determine the incidence and clinical symptoms associated with sharp mandibular bone irregularities (SMBI) after lower third molar extraction and to identify possible risk factors for this complication. Study Design: A mixed study design was used. A retrospective cohort study of 1432 lower third molar extractions was done to determine the incidence of SMBI and a retrospective case-control study was done to determine potential demographic and etiologic factors by comparing those patients with postoperative SMBI with controls. Results: Twelve SMBI were found (0.84%). Age was the most important risk factor for this complication. The operated side and the presence of an associated radiolucent image were also significantly related to the development of mandibular bone irregularities. The depth of impaction of the tooth might also be an important factor since erupted or nearly erupted third molars were more frequent in the SMBI group. Conclusions: SMBI are a rare postoperative complication after lower third molar removal. Older patients having left side lower third molars removed are more likely to develop this problem. The treatment should be the removal of the irregularity when the patient is symptomatic

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We analyze the timing of photons observed by the MAGIC telescope during a flare of the active galactic nucleus Mkn 501 for a possible correlation with energy, as suggested by some models of quantum gravity (QG), which predict a vacuum refractive index similar or equal to 1 + (E/M-QGn)(n), n = 1, 2. Parametrizing the delay between gamma-rays of different energies as Delta t = +/-tau E-1 or Delta t = +/-tau E-q(2), we find tau(1) = (0.030 +/- 0.012) s/GeV at the 2.5-sigma level, and tau(q) = (3.71 +/- 2.57) x 10(-6) s/GeV2, respectively. We use these results to establish lower limits M-QG1 > 0.21 X 10(18) GeV and M-QG2 > 0.26 x 10(11) GeV at the 95% C.L. Monte Carlo studies confirm the MAGIC sensitivity to propagation effects at these levels. Thermal plasma effects in the source are negligible, but we cannot exclude the importance of some other source effect.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Amber from a Lower Cretaceous outcrop at San Just, located in the Eastern Iberian Peninsula (Escucha Formation, Maestrat Basin), was investigated to evaluate its physico-chemical properties. Thermogravimetric (TG) and Differential Thermogravimetric (DTG) analyses, infra-red spectroscopy, elemental and C-isotope analyses were performed. Physico-chemical differences between the internal light nuclei and the peripheral darker portions of San Just amber can be attributed to processes of diagenetic alteration that preferentially took place in the external amber border colonized by microorganisms (fungi or bacteria) when the resin was still liquid or slightly polymerized. δ13Camber values of different pieces of the same sample, from the nucleus to the external part, are remarkably homogeneous, as are δ13Camber values of the darker peripheral portions and lighter inner parts of the same samples. Hence, neither invasive microorganisms, nor diagenetic alteration, changed the bulk isotopic composition of the amber. δ13C values of different amber samples range from -21.1 to -24 , as expected for C3 plant-derived material. C-isotope analysis, coupled to palaeobotanical, TG and DTG data and infra-red spectra, suggests that San Just amber was exuded by only one conifer species, belonging to either the Cheirolepidiaceae or Aracauriaceae, coniferous families probably living under stable palaeoenvironmental and palaeoecological conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We model the wavelength-dependent absorption of atmospheric gases by assuming constant mass absorption coefficients in finite-width spectral bands. Such a semigray atmosphere is analytically solved by a discrete ordinate method. The general solution is analyzed for a water vapor saturated atmosphere that also contains a carbon dioxide-like absorbing gas in the infrared. A multiple stable equilibrium with a relative upper limit in the outgoing long-wave radiation is found. Differing from previous radiative–convective models, we find that the amount of carbon dioxide strongly modifies the value of this relative upper limit. This result is also obtained in a gray (i.e., equal absorption of radiation at all infrared wavelengths) water vapor saturated atmosphere. The destabilizing effect of carbon dioxide implies that massive carbon dioxide atmospheres are more likely to reach a runaway greenhouse state than thin carbon dioxide ones

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Intraocular pressure (IOP) is the pressure inside the eye that helps to maintain the integrity and the suitable form of the ocular globe. Precise and accurate measures of IOP are needed for the diagnosis as well as follow-up of glaucoma. In daily clinical practice, Goldmann applanation tonometer (GAT) and Non-contact tonometer (NCT) are the most common devices for measuring IOP. A close agreement between these methods has been showed, particularly in normotensive patients and a poor agreement, especially when IOP levels are above the normal range. Ophthalmologists have noticed a poor agreement between NCT and GAT, observing that by using NCT and after comparing with GAT, there is an overestimation of IOP readings, and particularly it occurs when the eyes are tearful. Previous studies investigate the effect of tears in Non-contact tonometer readings by the instillation of artificial tears, concluding in one of the studies that the variation was less than 1mmHg and not clinically significant, in contrast with another study which the increases were sadistically significant. Tear menisci are a thin strip of tear fluid located between the bulbar conjunctiva and the eyelid margins. We think that the overestimation of IOP readings using NCT could be due to the presence of a higher volume of tear in the lower tear meniscus which might cause an optical interference in the optoelectronic applanation monitoring system of this deviceObjectives: To research the influence of a certain volume of fluid in the lower tear meniscus on IOP measurements using the NCT in healthy eyes. Moreover, to investigate the agreement between IOP readings obtained by NCT and GAT in the presence and absence of this volume of fluidMethods: The study design will be transversal for diagnostic tests of repeated measures. We will study patients with no ocular pathology and IOP<21mmHg. It will consist in the measurement of IOP using NCT before and after the instillation of COLIRCUSÍ FLUOTEST, used as a volume of fluid in the lower tear meniscus, to observe if there will be differences using the paired t-test. Moreover, we will take IOP measures by GAT in order to know the agreement between these methods after and before the application of these eyedrops, using the ICC (intraclass correlation coefficient) and the Bland-Altmann method