57 resultados para Resonant Converter
Resumo:
We study the response of Turing stripe patterns to a simple spatiotemporal forcing. This forcing has the form of a traveling wave and is spatially resonant with the characteristic Turing wavelength. Experiments conducted with the photosensitive chlorine dioxide-iodine-malonic acid reaction reveal a striking symmetry-breaking phenomenon of the intrinsic striped patterns giving rise to hexagonal lattices for intermediate values of the forcing velocity. The phenomenon is understood in the framework of the corresponding amplitude equations, which unveils a complex scenario of dynamical behaviors.
Resumo:
The development of shear instabilities of a wave-driven alongshore current is investigated. In particular, we use weakly nonlinear theory to investigate the possibility that such instabilities, which have been observed at various sites on the U.S. coast and in the laboratory, can grow in linearly stable flows as a subcritical bifurcation by resonant triad interaction, as first suggested by Shrira eta/. [1997]. We examine a realistic longshore current profile and include the effects of eddy viscosity and bottom friction. We show that according to the weakly nonlinear theory, resonance is possible and that these linearly stable flows may exhibit explosive instabilities. We show that this phenomenon may occur also when there is only approximate resonance, which is more likely in nature. Furthermore, the size of the perturbation that is required to trigger the instability is shown in some circumstances to be consistent with the size of naturally occurring perturbations. Finally, we consider the differences between the present case examined and the more idealized case of Shrira et a/. [ 1997]. It is shown that there is a possibility of coupling between triads, due to the richer modal structure in more realistic flows, which may act to stabilize the flow and act against the development of subcritical bifurcations. Extensive numerical tests are called for.
Resumo:
Purpose: To assess the feasibility of a method based on microwave spectrometry to detect structural distortions of metallic stents in open air conditions and envisage the prospects of this approach toward possible medical applicability for the evaluation of implanted stents. Methods: Microwave absorbance spectra between 2.0 and 18.0 GHz were acquired in open air for the characterization of a set of commercial stents using a specifically design setup. Rotating each sample over 360º, 2D absorbance diagrams were generated as a function of frequency and rotation angle. To check our approach for detecting changes in stent length (fracture) and diameter (recoil), two specific tests were performed in open air. Finally, with a few adjustments, this same system provides 2D absorbance diagrams of stents immersed in a water-based phantom, this time over a bandwidth ranging from 0.2 to 1.8 GHz. Results: The authors show that metallic stents exhibit characteristic resonant frequencies in their microwave absorbance spectra in open air which depend on their length and, as a result, may reflect the occurrence of structural distortions. These resonances can be understood considering that such devices behave like dipole antennas in terms of microwave scattering. From fracture tests, the authors infer that microwave spectrometry provides signs of presence of Type I to Type IV stent fractures and allows in particular a quantitative evaluation of Type III and Type IV fractures. Recoil tests show that microwave spectrometry seems able to provide some quantitative assessment of diametrical shrinkage, but only if it involves longitudinal shortening. Finally, the authors observe that the resonant frequencies of stents placed inside the phantom shift down with respect to the corresponding open air frequencies, as it should be expected considering the increase of dielectric permittivity from air to water. Conclusions: The evaluation of stent resonant frequencies provided by microwave spectrometry allows detection and some quantitative assessment of stent fracture and recoil in open air conditions. Resonances of stents immersed in water can be also detected and their characteristic frequencies are in good agreement with theoretical estimates. Although these are promising results, further verifica tion in a more relevant phantom is required in order to foresee the real potential of this approach.
Resumo:
In this paper we design and develop several filtering strategies for the analysis of data generated by a resonant bar gravitational wave (GW) antenna, with the goal of assessing the presence (or absence) therein of long-duration monochromatic GW signals, as well as the eventual amplitude and frequency of the signals, within the sensitivity band of the detector. Such signals are most likely generated in the fast rotation of slightly asymmetric spinning stars. We develop practical procedures, together with a study of their statistical properties, which will provide us with useful information on the performance of each technique. The selection of candidate events will then be established according to threshold-crossing probabilities, based on the Neyman-Pearson criterion. In particular, it will be shown that our approach, based on phase estimation, presents a better signal-to-noise ratio than does pure spectral analysis, the most common approach.
Resumo:
Purpose: To assess the feasibility of a method based on microwave spectrometry to detect structural distortions of metallic stents in open air conditions and envisage the prospects of this approach toward possible medical applicability for the evaluation of implanted stents. Methods: Microwave absorbance spectra between 2.0 and 18.0 GHz were acquired in open air for the characterization of a set of commercial stents using a specifically design setup. Rotating each sample over 360º, 2D absorbance diagrams were generated as a function of frequency and rotation angle. To check our approach for detecting changes in stent length (fracture) and diameter (recoil), two specific tests were performed in open air. Finally, with a few adjustments, this same system provides 2D absorbance diagrams of stents immersed in a water-based phantom, this time over a bandwidth ranging from 0.2 to 1.8 GHz. Results: The authors show that metallic stents exhibit characteristic resonant frequencies in their microwave absorbance spectra in open air which depend on their length and, as a result, may reflect the occurrence of structural distortions. These resonances can be understood considering that such devices behave like dipole antennas in terms of microwave scattering. From fracture tests, the authors infer that microwave spectrometry provides signs of presence of Type I to Type IV stent fractures and allows in particular a quantitative evaluation of Type III and Type IV fractures. Recoil tests show that microwave spectrometry seems able to provide some quantitative assessment of diametrical shrinkage, but only if it involves longitudinal shortening. Finally, the authors observe that the resonant frequencies of stents placed inside the phantom shift down with respect to the corresponding open air frequencies, as it should be expected considering the increase of dielectric permittivity from air to water. Conclusions: The evaluation of stent resonant frequencies provided by microwave spectrometry allows detection and some quantitative assessment of stent fracture and recoil in open air conditions. Resonances of stents immersed in water can be also detected and their characteristic frequencies are in good agreement with theoretical estimates. Although these are promising results, further verifica tion in a more relevant phantom is required in order to foresee the real potential of this approach.
Resumo:
The analysis of paraxial Gaussian beams features in most undergraduate courses in laser physics, advanced optics and photonics. These beams provide a simple model of the field generated in the resonant cavities of lasers, thus constituting a basic element for understanding laser theory. Usually, uniformly polarized beams are considered in the analytical calculations, with the electric field vibrating at normal planes to the propagation direction. However, such paraxial fields do not verify the Maxwell equations. In this paper we discuss how to overcome this apparent contradiction and evaluate the longitudinal component that any paraxial Gaussian beam should exhibit. Despite the fact that the assumption of a purely transverse paraxial field is useful and accurate, the inclusion of the above issue in the program helps students to clarify the importance of the electromagnetic nature of light, thus providing a more complete understanding of the paraxial approach.
Resumo:
Nanoantennae show potential for photosynthesis research for two reasons; first by spatially confining light for experiments which require high spatial resolution, and second by enhancing the photon emission of single light-harvesting complexes. For effective use of nanoantennae a detailed understanding of the interaction between the nanoantenna and the light-harvesting complex is required. Here we report how the excitation and emission of multiple purple bacterial LH2s (light-harvesting complex 2) are controlled by single gold nanorod antennae. LH2 complexes were chemically attached to such antennae, and the antenna length was systematically varied to tune the resonance with respect to the LH2 absorption and emission. There are three main findings. (i) The polarization of the LH2 emission is fully controlled by the resonant nanoantenna. (ii) The largest fluorescence enhancement, of 23 times, is reached for excitation with light at λ = 850 nm, polarized along the long antenna-axis of the resonant antenna. The excitation enhancement is found to be 6 times, while the emission efficiency is increased 3.6 times. (iii) The fluorescence lifetime of LH2 depends strongly on the antenna length, with shortest lifetimes of [similar]40 ps for the resonant antenna. The lifetime shortening arises from an 11 times resonant enhancement of the radiative rate, together with a 2–3 times increase of the non-radiative rate, compared to the off-resonant antenna. The observed length dependence of radiative and non-radiative rate enhancement is in good agreement with simulations. Overall this work gives a complete picture of how the excitation and emission of multi-pigment light-harvesting complexes are influenced by a dipole nanoantenna.
Resumo:
The causal mechanism and seasonal evolution of the internal wave field in a deep, warm, monomictic reservoirare examined through the analysis of field observations and numerical techniques. The study period extends fromthe onset of thermal stratification in the spring until midsummer in 2005. During this time, wind forcing wasperiodic, with a period of 24 h (typical of land–sea breezes), and the thermal structure in the lake wascharacterized by the presence of a shallow surface layer overlying a thick metalimnion, typical of small to mediumsized reservoirs with deep outtakes. Basin-scale internal seiches of high vertical mode (ranging from mode V3 toV5) were observed in the metalimnion. The structure of the dominant modes of oscillation changed asstratification evolved on seasonal timescales, but in all cases, their periods were close to that of the local windforcing (i.e., 24 h), suggesting a resonant response. Nonresonant oscillatory modes of type V1 and V2 becamedominant after large frontal events, which disrupted the diurnal periodicity of the wind forcing
Resumo:
Self-sustained time-dependent current oscillations under dc voltage bias have been observed in recent experiments on n-doped semiconductor superlattices with sequential resonant tunneling. The current oscillations are caused by the motion and recycling of the domain wall separating low- and high-electric-field regions of the superlattice, as the analysis of a discrete drift model shows and experimental evidence supports. Numerical simulation shows that different nonlinear dynamical regimes of the domain wall appear when an external microwave signal is superimposed on the dc bias and its driving frequency and driving amplitude vary. On the frequency-amplitude parameter plane, there are regions of entrainment and quasiperiodicity forming Arnold tongues. Chaos is demonstrated to appear at the boundaries of the tongues and in the regions where they overlap. Coexistence of up to four electric-field domains randomly nucleated in space is detected under ac+dc driving.
Resumo:
We show the existence of families of hip-hop solutions in the equal-mass 2N-body problem which are close to highly eccentric planar elliptic homographic motions of 2N bodies plus small perpendicular non-harmonic oscillations. By introducing a parameter ϵ, the homographic motion and the small amplitude oscillations can be uncoupled into a purely Keplerian homographic motion of fixed period and a vertical oscillation described by a Hill type equation. Small changes in the eccentricity induce large variations in the period of the perpendicular oscillation and give rise, via a Bolzano argument, to resonant periodic solutions of the uncoupled system in a rotating frame. For small ϵ ≠ 0, the topological transversality persists and Brouwer's fixed point theorem shows the existence of this kind of solutions in the full system
Resumo:
Poder mesurar i enregistrar diferents tipus de magnituds com pressió, força, temperatura etc. s’ha convertit en una necessitat per moltes aplicacions actuals. Aquestes magnituds poden tenir procedències molt diverses, tals com l’entorn, o poden ser generades per sistemes mecànics, elèctrics, etc. Per tal de poder adquirir aquestes magnituds, s’utilitzen els sistemes d’adquisició de dades. Aquests sistemes, prenen mostres analògiques del món real, i les transformen en dades digitals que poden ser manipulades per un sistema electrònic. Pràcticament qualsevol magnitud es pot mesurar utilitzant el sensor adient. Una magnitud molt utilitzada en sistemes d’adquisició de dades, és la temperatura. Els sistemes d’adquisició de temperatures estan molt generalitzats, i podem trobar-los com a sistemes, on l’objectiu és mostrar les dades adquirides, o podem trobar-los formant part de sistemes de control, aportant uns inputs necessaris per el seu correcte funcionament, garantir-ne l’estabilitat, seguretat etc. Aquest projecte, promogut per l’empresa Elausa, s’encarregarà d’adquirir, el senyal d’entrada de 2 Termoparells. Aquests mesuraran temperatures de circuits electrònics, que es trobaran dintre la càmera climàtica de Elausa, sotmesos a diferents condicions de temperatura, per tal de rebre l’homologació del circuit. El sistema haurà de poder mostrar les dades adquirides en temps real, i emmagatzemar-les en un PC que estarà ubicat en una oficina, situada a uns 30 m de distància de la sala on es farà el test. El sistema constarà d’un circuit electrònic que adquirirà, i condicionarà el senyal de sortida dels termoparells, per adaptar-lo a la tensió d’entrada d’un convertidor analògic digital, del microcontrolador integrat en aquesta placa. Seguidament aquesta informació, s’enviarà a través d’un mòdul transmissor de radiofreqüència, cap al PC on es visualitzaran les dades adquirides. Els objectius plantejats són els següents: - Dissenyar el circuit electrònic d’adquisició i condicionament del senyal. - Dissenyar, fabricar i muntar el circuit imprès de la placa d’adquisició. - Realitzar el programa de control del microcontrolador. - Realitzar el programa per presentar i desar les dades en un PC. - El sistema ha d’adquirir 2 temperatures, a través de Termoparells amb un rang d’entrada de -40ºC a +240ºC - S’ha de transmetre les dades via R.F. Els resultats del projecte han estat satisfactoris i s’han complert els objectius plantejats.
Resumo:
En termes generals, es pot definir l’Eficiència Energètica com la reducció del consum d’energia mantenint els mateixos serveis energètics, sense disminuir el nostre confort i qualitat de vida, protegint el medi ambient, assegurant el proveïment i fomentant un comportament Sostenible al seu ús. L’objectiu principal d’aquest treball, és reduir el consum d’energia i terme de potència contractat a la Universitat de Vic, aplicant un programa d’estalvi amb mesures correctores en el funcionament de les seves instal·lacions o espais. Per tal de poder arribar a aquest objectiu marcat, prèviament s’ha realitzat un estudi acurat, obtenint tota la informació necessària per poder aplicar les mesures correctores a la bossa més important de consum. Un cop trobada, dur a terme l’estudi de la viabilitat de la inversió de les mesures correctores més eficients, optimitzant els recursos destinats. L’espai on s’ha dut a terme l’estudi, ha estat a l’edifici F del Campus Miramarges, seguint les indicacions d’Arnau Bardolet (Cap de Manteniment de la UVIC). Aquest edifici consta d’un entresol, baixos i quatre plantes. L’equip de mesura que s’ha fet servir per realitzar l’estudi, és de la marca Circutor sèrie AR5-L, aquests equips són programables que mesuren, calculen i emmagatzemen en memòria els principals paràmetres elèctrics en xarxes trifàsiques. Els projectes futurs complementaris que es podrien realitzar a part d’aquest són: instal·lar sensors, instal·lar mòduls convertidors TCP/IP, aprofitar la xarxa intranet i crear un escada amb un sinòptic de control i gestió des d’un punt de treball. Aquest aplicatiu permet visualitzar en una pantalla d’un PC tots els estats dels elements controlats mitjançant un sinòptic (encendre/parar manualment l’enllumenat i endolls de les aules, estat d’enllumenat i endolls de les aules, consums instantanis/acumulats energètics, estat dels passadissos entre altres) i explotar les dades recollides a la base de dades. Cada espai tindria la seva lògica de funcionament automàtic específic. Entre les conclusions més rellevants obtingudes en aquest treball s’observa: · Que és pot reduir la potència contractada a la factura a l’estar per sota de la realment consumida. · Que no hi ha penalitzacions a la factura per consum de reactiva, ja que el compensador funciona correctament. · Que es pot reduir l’horari de l’inici del consum d’energia, ja que no correspon a l’activitat docent. · Els valors de la tensió i freqüència estan dintre de la normalitat. · Els harmònics estan al llindar màxim. Analitzant aquestes conclusions, voldria destacar les mesures correctores més importants que es poden dur a terme: canvi tecnològic a LED, temporitzar automàticament l’encesa i apagada dels fluorescents i equips informàtics de les aules “seguint calendari docent”, instal·lar sensors de moviment amb detecció lumínica als passadissos. Totes les conclusions extretes d’aquest treball, es poden aplicar a tots els edificis de la facultat, prèviament realitzant l’estudi individual de cadascuna, seguint els mateixos criteris per tal d’optimitzar la inversió.