48 resultados para Radiometric calibration
Resumo:
We have developed a differential scanning calorimeter capable of working under applied magnetic fields of up to 5 T. The calorimeter is highly sensitive and operates over the temperature range 10¿300 K. It is shown that, after a proper calibration, the system enables determination of the latent heat and entropy changes in first-order solid¿solid phase transitions. The system is particularly useful for investigating materials that exhibit the giant magnetocaloric effect arising from a magnetostructural phase transition. Data for Gd5(Si0.1Ge0.9)4 are presented.
Resumo:
Application of semi-distributed hydrological models to large, heterogeneous watersheds deals with several problems. On one hand, the spatial and temporal variability in catchment features should be adequately represented in the model parameterization, while maintaining the model complexity in an acceptable level to take advantage of state-of-the-art calibration techniques. On the other hand, model complexity enhances uncertainty in adjusted model parameter values, therefore increasing uncertainty in the water routing across the watershed. This is critical for water quality applications, where not only streamflow, but also a reliable estimation of the surface versus subsurface contributions to the runoff is needed. In this study, we show how a regularized inversion procedure combined with a multiobjective function calibration strategy successfully solves the parameterization of a complex application of a water quality-oriented hydrological model. The final value of several optimized parameters showed significant and consistentdifferences across geological and landscape features. Although the number of optimized parameters was significantly increased by the spatial and temporal discretization of adjustable parameters, the uncertainty in water routing results remained at reasonable values. In addition, a stepwise numerical analysis showed that the effects on calibration performance due to inclusion of different data types in the objective function could be inextricably linked. Thus caution should be taken when adding or removing data from an aggregated objective function.
Resumo:
En la actualidad, las cooperativas recolectan, seleccionan, tratan y separan la fruta según su calibre (peso, diámetro máximo, medio y/o mínimo) para que esta llegue al consumidor final según la categoría (calibre). Para poder competir en un mercado cada vez más exigente en calidad y precios, se requieren sistemas de clasificación automáticos que nos permitan obtener óptimos resultados con altos niveles de producción y productividad. Para realizar estas tareas existen calibradoras industriales que pesan la fruta mediante células de carga y con el peso obtenido las clasifican asignando las piezas a su salida correspondiente (mesa de confección) a través de un sistema de electroimanes. Desafortunadamente el proceso de calibración de la fruta por peso no es en absoluto fiable ya que en este proceso no se considera el grosor de la piel, contenido de agua, de azúcar u otros factores altamente relevantes que influyen considerablemente en los resultados finales. El objeto de este proyecto es el de evolucionar las existentes calibradoras de fruta instalando un sistema industrial de visión artificial (rápido y robusto) que trabaje en un rango de espectro Infrarrojo (mayor fiabilidad) proporcionando óptimos resultados finales en la clasificación de las frutas, verduras y hortalizas. De este modo, el presente proyecto ofrece la oportunidad de mejorar el rendimiento de la línea de clasificación de frutas, aumentando la velocidad, disminuyendo pérdidas en tiempo y error humano y mejorando indiscutiblemente la calidad del producto final deseada por los consumidores.