92 resultados para Pulse techniques (Electronics)
Resumo:
Transmission electron microscopy is a proven technique in the field of cell biology and a very useful tool in biomedical research. Innovation and improvements in equipment together with the introduction of new technology have allowed us to improve our knowledge of biological tissues, to visualizestructures better and both to identify and to locate molecules. Of all the types ofmicroscopy exploited to date, electron microscopy is the one with the mostadvantageous resolution limit and therefore it is a very efficient technique fordeciphering the cell architecture and relating it to function. This chapter aims toprovide an overview of the most important techniques that we can apply to abiological sample, tissue or cells, to observe it with an electron microscope, fromthe most conventional to the latest generation. Processes and concepts aredefined, and the advantages and disadvantages of each technique are assessedalong with the image and information that we can obtain by using each one ofthem.
Resumo:
This Handbook contains a collection of articles describing instrumental techniques used for Materials, Chemical and Biosciences research that are available at the Scientific and Technological Centers of theUniversity of Barcelona (CCiTUB). The CCiTUB are a group of facilities of the UB that provide both the research community and industry with ready access to a wide range of major instrumentation.Together with the latest equipment and technology, the CCiTUB provide expertise in addressing the methodological research needs of the user community and they also collaborate in R+D+i Projectswith industry. CCiTUB specialists include technical and Ph.D.-level professional staff members who are actively engaged in methodological research. Detailed information on the centers’ resources andactivities can be found at the CCiTUB website www.ccit.ub.edu ...
Resumo:
This article summarizes the basic principles of light microscopy, with examples of applications in biomedicine that illustrate the capabilities of thetechnique.
Resumo:
Excitation-continuous music instrument control patterns are often not explicitly represented in current sound synthesis techniques when applied to automatic performance. Both physical model-based and sample-based synthesis paradigmswould benefit from a flexible and accurate instrument control model, enabling the improvement of naturalness and realism. Wepresent a framework for modeling bowing control parameters inviolin performance. Nearly non-intrusive sensing techniques allow for accurate acquisition of relevant timbre-related bowing control parameter signals.We model the temporal contour of bow velocity, bow pressing force, and bow-bridge distance as sequences of short Bézier cubic curve segments. Considering different articulations, dynamics, and performance contexts, a number of note classes are defined. Contours of bowing parameters in a performance database are analyzed at note-level by following a predefined grammar that dictates characteristics of curve segment sequences for each of the classes in consideration. As a result, contour analysis of bowing parameters of each note yields an optimal representation vector that is sufficient for reconstructing original contours with significant fidelity. From the resulting representation vectors, we construct a statistical model based on Gaussian mixtures suitable for both the analysis and synthesis of bowing parameter contours. By using the estimated models, synthetic contours can be generated through a bow planning algorithm able to reproduce possible constraints caused by the finite length of the bow. Rendered contours are successfully used in two preliminary synthesis frameworks: digital waveguide-based bowed stringphysical modeling and sample-based spectral-domain synthesis.
Resumo:
We analyse the use of the ordered weighted average (OWA) in decision-making giving special attention to business and economic decision-making problems. We present several aggregation techniques that are very useful for decision-making such as the Hamming distance, the adequacy coefficient and the index of maximum and minimum level. We suggest a new approach by using immediate weights, that is, by using the weighted average and the OWA operator in the same formulation. We further generalize them by using generalized and quasi-arithmetic means. We also analyse the applicability of the OWA operator in business and economics and we see that we can use it instead of the weighted average. We end the paper with an application in a business multi-person decision-making problem regarding production management
Resumo:
This special issue aims to cover some problems related to non-linear and nonconventional speech processing. The origin of this volume is in the ISCA Tutorial and Research Workshop on Non-Linear Speech Processing, NOLISP’09, held at the Universitat de Vic (Catalonia, Spain) on June 25–27, 2009. The series of NOLISP workshops started in 2003 has become a biannual event whose aim is to discuss alternative techniques for speech processing that, in a sense, do not fit into mainstream approaches. A selected choice of papers based on the presentations delivered at NOLISP’09 has given rise to this issue of Cognitive Computation.
Resumo:
In this paper we present a method for blind deconvolution of linear channels based on source separation techniques, for real word signals. This technique applied to blind deconvolution problems is based in exploiting not the spatial independence between signals but the temporal independence between samples of the signal. Our objective is to minimize the mutual information between samples of the output in order to retrieve the original signal. In order to make use of use this idea the input signal must be a non-Gaussian i.i.d. signal. Because most real world signals do not have this i.i.d. nature, we will need to preprocess the original signal before the transmission into the channel. Likewise we should assure that the transmitted signal has non-Gaussian statistics in order to achieve the correct function of the algorithm. The strategy used for this preprocessing will be presented in this paper. If the receiver has the inverse of the preprocess, the original signal can be reconstructed without the convolutive distortion.
Resumo:
Objectives: Benign Oral Vascular Lesions (BOVLs) are a group of vascular diseases characterized by congenital, inflammatory or neoplastic vascular dilations clinically evidenced as more or less wide masses of commonly dark bluish color. If traumatized BOVLs are characterized by a great risk of hemorrhage and their treatment usually requires great caution to prevent massive bleeding. In the last decades lasers have dramatically changed the way of treatment of BOVLs permitting the application of even peculiar techniques that gave interesting advantages in their management reducing hemorrhage risks. The aim of this study was to evaluate the capabilities and disadvantages of three laser assisted techniques in the management of BOVLs. Study design: In this study 13 BOVLs were treated by three different laser techniques: the traditional excisional biopsy (EB), and two less invasive techniques, the transmucosal thermocoagulation (TMT) and the intralesional photocoagulation (ILP). Two different laser devices were adopted in the study: a KTP laser (DEKA, Florence, Italy, 532nm) and a GaAlAs laser (Laser Innovation, Castelgandolfo, Italy, 808nm) selected since their great effectiveness on hemoglobin. Results: In each case, lasers permitted safe treatments of BOVLs without hemorrhages, both during the intervention and in the post-operative period. The minimally invasive techniques (TMT and ILP) permitted even the safe resolution of big lesions without tissue loss. Conclusions: Laser devices confirm to be the gold standard in BOVLs treatment, permitting even the introduction of minimal invasive surgery principles and reducing the risks of hemorrhage typical of these neoplasms. As usual in laser surgery, it is necessary a clear knowledge of the devices and of the laser-tissue interaction to optimize the results reducing risks and disadvantages
Resumo:
We analyse the use of the ordered weighted average (OWA) in decision-making giving special attention to business and economic decision-making problems. We present several aggregation techniques that are very useful for decision-making such as the Hamming distance, the adequacy coefficient and the index of maximum and minimum level. We suggest a new approach by using immediate weights, that is, by using the weighted average and the OWA operator in the same formulation. We further generalize them by using generalized and quasi-arithmetic means. We also analyse the applicability of the OWA operator in business and economics and we see that we can use it instead of the weighted average. We end the paper with an application in a business multi-person decision-making problem regarding production management
Resumo:
Background:There is no actual evidence that the ART are directly related to the occurrence of weight discordance. In some studies, ART-‐conceived twin pregnancies are at greater risk than non-‐ART-‐conceived ones for pregnancy complications and adverse perinatal outcome: the incidences of pregnancy-‐induced hypertension, uterine bleeding, premature contractions, IUGR, fetal death, discordance, and cesarean section were significantly higher. Discordance rate was elevated (25.3% vs.17.0%) among ART twins, which can increase perinatal risk (increased incidence of SGA and NICU admission). Other studies say that perinatal and neonatal morbidity, gestational age at delivery, and birth weight are not affected by ART. Regarding the first trimester ultrasound, some studies didn’t notice significant differences in CRL disparity or birth weight discordance between spontaneous and ART-‐ conceived dichorionic twin pregnancies. In ART-‐conceived dichorionic twin pregnancies, CRL disparity may be associated with birth weight discordance. In some studies, CRL discordance in twin pregnancies in the first trimester was a frequent finding. Objectives: To analyze the association of the ART in the occurrence of weight discordance in the pregnancies between 2010 and 2013 in the Hospital Universitari de Girona Doctor Josep Trueta, and to describe the proportion of diagnosis of growth discordance in the first trimester by the ultrasonography technology. Methods: A retrospective cohort study will be performed in those patients with twin pregnancies between 2010 and 2013, within the Hospital Universitari de Girona Doctor Josep Trueta (HUJT). A retrospective and descriptive study will be done in those cases with discordance weight in the moment of the birth, in which the CRL will be studied in the first trimester ultrasound, describing the percentage of discordance detected in that moment. The general characteristics of the sample are going to be analyzed by Logistic RegressionInfluenceof
Resumo:
Background:There is no actual evidence that the ART are directly related to the occurrence of weight discordance. In some studies, ART-‐conceived twin pregnancies are at greater risk than non-‐ART-‐conceived ones for pregnancy complications and adverse perinatal outcome: the incidences of pregnancy-‐induced hypertension, uterine bleeding, premature contractions, IUGR, fetal death, discordance, and cesarean section were significantly higher. Discordance rate was elevated (25.3% vs.17.0%) among ART twins, which can increase perinatal risk (increased incidence of SGA and NICU admission). Other studies say that perinatal and neonatal morbidity, gestational age at delivery, and birth weight are not affected by ART. Regarding the first trimester ultrasound, some studies didn’t notice significant differences in CRL disparity or birth weight discordance between spontaneous and ART-‐ conceived dichorionic twin pregnancies. In ART-‐conceived dichorionic twin pregnancies, CRL disparity may be associated with birth weight discordance. In some studies, CRL discordance in twin pregnancies in the first trimester was a frequent finding. Objectives: To analyze the association of the ART in the occurrence of weight discordance in the pregnancies between 2010 and 2013 in the Hospital Universitari de Girona Doctor Josep Trueta, and to describe the proportion of diagnosis of growth discordance in the first trimester by the ultrasonography technology. Methods: A retrospective cohort study will be performed in those patients with twin pregnancies between 2010 and 2013, within the Hospital Universitari de Girona Doctor Josep Trueta (HUJT). A retrospective and descriptive study will be done in those cases with discordance weight in the moment of the birth, in which the CRL will be studied in the first trimester ultrasound, describing the percentage of discordance detected in that moment. The general characteristics of the sample are going to be analyzed by Logistic RegressionInfluenceof
Resumo:
Background:There is no actual evidence that the ART are directly related to the occurrence of weight discordance. In some studies, ART-‐conceived twin pregnancies are at greater risk than non-‐ART-‐conceived ones for pregnancy complications and adverse perinatal outcome: the incidences of pregnancy-‐induced hypertension, uterine bleeding, premature contractions, IUGR, fetal death, discordance, and cesarean section were significantly higher. Discordance rate was elevated (25.3% vs.17.0%) among ART twins, which can increase perinatal risk (increased incidence of SGA and NICU admission). Other studies say that perinatal and neonatal morbidity, gestational age at delivery, and birth weight are not affected by ART. Regarding the first trimester ultrasound, some studies didn’t notice significant differences in CRL disparity or birth weight discordance between spontaneous and ART-‐ conceived dichorionic twin pregnancies. In ART-‐conceived dichorionic twin pregnancies, CRL disparity may be associated with birth weight discordance. In some studies, CRL discordance in twin pregnancies in the first trimester was a frequent finding. Objectives: To analyze the association of the ART in the occurrence of weight discordance in the pregnancies between 2010 and 2013 in the Hospital Universitari de Girona Doctor Josep Trueta, and to describe the proportion of diagnosis of growth discordance in the first trimester by the ultrasonography technology. Methods: A retrospective cohort study will be performed in those patients with twin pregnancies between 2010 and 2013, within the Hospital Universitari de Girona Doctor Josep Trueta (HUJT). A retrospective and descriptive study will be done in those cases with discordance weight in the moment of the birth, in which the CRL will be studied in the first trimester ultrasound, describing the percentage of discordance detected in that moment. The general characteristics of the sample are going to be analyzed by Logistic RegressionInfluenceof
A Survey on Detection Techniques to Prevent Cross-Site Scripting Attacks on Current Web Applications
Resumo:
In this paper, an advanced technique for the generation of deformation maps using synthetic aperture radar (SAR) data is presented. The algorithm estimates the linear and nonlinear components of the displacement, the error of the digital elevation model (DEM) used to cancel the topographic terms, and the atmospheric artifacts from a reduced set of low spatial resolution interferograms. The pixel candidates are selected from those presenting a good coherence level in the whole set of interferograms and the resulting nonuniform mesh tessellated with the Delauney triangulation to establish connections among them. The linear component of movement and DEM error are estimated adjusting a linear model to the data only on the connections. Later on, this information, once unwrapped to retrieve the absolute values, is used to calculate the nonlinear component of movement and atmospheric artifacts with alternate filtering techniques in both the temporal and spatial domains. The method presents high flexibility with respect to the required number of images and the baselines length. However, better results are obtained with large datasets of short baseline interferograms. The technique has been tested with European Remote Sensing SAR data from an area of Catalonia (Spain) and validated with on-field precise leveling measurements.
Resumo:
Compared to synthetic aperture radars (SARs), the angular resolution of microwave radiometers is quite poor. Traditionally, it has been limited by the physical size of the antenna. However, the angular resolution can be improved by means of aperture synthesis interferometric techniques. A narrow beam is synthesized during the image formation processing of the cross-correlations measured at zero-lag between pairs of signals collected by an array of antennas. The angular resolution is then determined by the maximum antenna spacing normalized to the wavelength (baseline). The next step in improving the angular resolution is the Doppler-Radiometer, somehow related to the super-synthesis radiometers and the Radiometer-SAR. This paper presents the concept of a three-antenna Doppler-Radiometer for 2D imaging. The performance of this instrument is evaluated in terms of angular/spatial resolution and radiometric sensitivity, and an L-band illustrative example is presented.